• Title/Summary/Keyword: High temperature gas chromatography

Search Result 78, Processing Time 0.024 seconds

Effects of Operation Conditions on Hydrocarbon Components Emitted from SI Engine with Gaseous Fuels (기체 연료를 사용한 전기점화기관에서 운전조건이 HC 배출물 성분에 미치는 영향)

  • 박종범;최희명;이형승;김응서
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.1
    • /
    • pp.108-121
    • /
    • 1998
  • Using gas chromatography, the light hydrocarbon emissions were analyzed from SI engine fueled with methane and liquified petroleum gas(LPG), and the effects of fuel and engine operating condition were discussed. For this purpose, 14 species of light hydrocarbon including 1, 3-butadiene were separated, calibrated with standard gas, and measured from undiluted emissions. The brake specific hydrocarbon emission(BSHC) and ozone forming potential(BSO)3 were calculated and discussed with the changes of fuel, engine speed, load, fuel/air equivalence ratio, coolant temperature, and spark timing. As a result, exhaust emission was composed of mainly fuel composed of mainly fuel comp- onent and other olefin components of similar carbon number. The olefin components such as ethylene and propylene determine most of the ozone forming potential. The fraction of fuel component in total hydrocarbon emission was bigger with methane fuel than with LPG fuel. Also fuel fraction increased at high speed or high speed or high temperature of exhaust gas, and to lesser extent with high coolant temperature and retarded spark. However, the effect of equivalence ratio had different tendency according to fuels.

  • PDF

Effect of High Temperature and Growth Light Intensity on Fatty Acid Composition of Panax ginseng leaf (고온(高溫)과 재배광도(栽培光度)가 인삼(人蔘) 잎의 지방산(脂肪酸) 조성(組成)에 미치는 영향(影響))

  • Park, Hoon;Park, Hyeon-Suk;Hong, Jong-Uck
    • Applied Biological Chemistry
    • /
    • v.29 no.4
    • /
    • pp.366-371
    • /
    • 1986
  • Fatty acid compositions of Panax ginseng leaves (6 year) grown under different light intensity in field and of the detached leaves exposed to high temperature (20 hours) were investigated by gas chromatography. Linoleic, linolenic, palmitic and palmitoleic acid were the major components(80%) of leaf lipid. The higher the growth light intensity, the lower the percentage of unsaturated acids or bonds, indicating metabolic adaptation to high temperature. Pattern similarity of fatty acid composition was little changed until 20% light but significantly different at 30%, suggesting 20% as limitation light intensity. The close similarity of fatty acid composition between the loaves grown under 30% light and the one at harvest rises uncertainty between adaptation to high temperature and senescence. Total fatty acid content decreased with the increase of light intensity. Short term high temperature $(25^{\circ}C\;or\;35^{\circ}C)$ increased total fatty acid content, unsaturated acid percentage and insignificant difference in pattern similarity of composition.

  • PDF

Multichannel Liquid Phase Microextraction System (다채널 액상 미세 추출 시스템 설계 및 제작)

  • Zhang, XinJie;Cheng, Shuo;Piao, Xiang Fan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.10
    • /
    • pp.1-7
    • /
    • 2020
  • In this study, a multichannel gas-liquid microextraction system is designed by integrating the automatic elution of extraction line and multichannel gas-purging liquid phase microextraction. The system uses an injection pump and inert gas to push the extraction solvent to a sample bottle of a gas-phase color autosampler and then implements multichannel gas-liquid microextraction and gas chromatography-mass spectrometry. The system also employs a three-way integrated micro-high-temperature heater, syringe pump, and microflow controller to realize the simultaneous processing of multiple groups of samples, thus improving the sample pretreatment speed and reproducibility and reducing human error. Autoinjection experiments were implemented with polycyclic aromatic hydrocarbon standard samples. The experiments show that the average recovery rate of the system exceeds 70%, and the relative standard among the channels is less than 15%.

A High-speed Miniature Screening Gaschromatograph with Flame Ionization Detector

  • Banik Rahul;Lee Dong-Yeon;Gweon Dae-Gab
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.12
    • /
    • pp.2197-2204
    • /
    • 2005
  • The combination of Gas chromatography (GC) for separation and Flame Ionization Detection (FID) for detection and identification of the components of a mixture of compounds is a fast and strongly proved method of analytic chemistry. The objective of this research was to design a combined High-speed miniature screening Gas chromatograph along with a Flame Ionization Detector for quick, quantitative and qualitative analysis of gas components. This combined GC-FID system is suitable to detect the volatile and semi-volatile hydrocarbons present in a gas mixture. The construction made it less expensive, easy to use and movable. The complete gas path was developed. On/off valves, temperature and flow sensors and their interface electronics were used for controlling purpose. A Microcontroller was programmed to measure the temperature and gas flow using the sensors and to control and regulate them using the electronics and valves. A pocket PC with its touch screen served as a user interface for the system. Software was developed for the pocket PC, which makes the communication possible with the Microcontroller. The system parameters can be indicated in the Pocket PC as simple text and also the analysis result can be displayed.

On the Pyrolysis of Polymers IV. Pyrolysis of Polythylene and Polypropylene (高分子物質의 熱分解에 關한 硏究 (第4報) Polyethylene 및 Polypropylene의 熱分解에 關하여)

  • Chwa-Kyung Sung;Icksam Noh;Jung Yup Kim;Sung Bong Chang
    • Journal of the Korean Chemical Society
    • /
    • v.7 no.2
    • /
    • pp.122-127
    • /
    • 1963
  • Pyrolysis fo polyethylene and polypropylene has been studied in order to clarify the mechanism of chain scission and effect of oxygen on degradation. Rate of weight decrease was measured under nitrogen and air atmosphere at constant temperature for the samples of high density polyethylene, low density polyethylene and isotactic polypropylene, and then gaseous hydrocarbons produced from pyrolysis were analysed by gas chromatography. Although there is little substantial difference between composition of hydrocarbon gases from pyrolysis of high density polyethylene and low density polyethylene except some difference in quantity of total gas produced, gas composition from polypropylene pyrolysis differs from that of polyethylene pyrolysis. Gases from pyrolysis under air contain much more unsaturated hydrocarbons than those from pyrolysis under inert gas.

  • PDF

Simultaneous detection for synthetic antimicrobials in muscle by high performance liquid chromatography-mass selective detector (HPLC-MSD) (HPLC-MSD 를 이용한 식육 중 합성항균제의 동시분석)

  • Hong In-Suk;Choi Yoon-Hwa;Kwon Taek-Boo;Lee Jung-Hark
    • Korean Journal of Veterinary Service
    • /
    • v.29 no.3
    • /
    • pp.317-330
    • /
    • 2006
  • This study was conducted to develop the analytical method about simultaneous determination for synthetic antimicrobials in muscle by high performance liquid chromatography - mass selective detector (HPLC- MSD). Solid phase extraction (SPE), matrix solid phase dispersion (MSPD) and liquid-liquid extraction (LLE) have been adapted as pretreatment procedures for HPLC- MSD. Among various solvent tested, methanol was chosen for extraction of synthetic antimicrobials in muscles. For the optimized response, the values of various MS parameters including fragment voltage, drying gas flow, nebulizer pressure, drying gas temperature were verified. The average recovery rates using MSPD and SPE for muscles of bovine and pork were 78.9-127.1% and 78.3-121.7%, respectively. This method was verified the satisfactory performance for fourteen synthetic antimicrobials excepting carbadox in muscle of pork as detection limit of $0.05{\mu}g/g$ on API/ES SIM mode.

Study on Oil Production from Pyrolysis of Mixed Plastic Waste Using Multidimensional Chromatography (Multidimensional Chromatography/Mass Spectrometry를 이용한 혼합 폐플라스틱의 열분해 오일 특성 평가에 관한 연구)

  • 김석완
    • Journal of Environmental Science International
    • /
    • v.11 no.4
    • /
    • pp.375-382
    • /
    • 2002
  • The total hydrocarbon distribution of oil products obtained from the pyrolysis of four kinds of mixtures of polyethylene-polystyrene waste has been studied by multidimensional chromatography(high performance liquid chromatography followed by capillary gas chromatography)/mass spectrometry. Saturated, unsaturated and aromatic hydrocarbons in oil products were selectively pre-separated according to structural groups by HPLC and the weight fraction of each group was estimated by analysis of each component using GC-FID response factors. The hydrocarbon distribution of aliphatic fraction consists of $C_{5}$ to $C_{25}$ saturated and unsaturated hydrocarbons. And that of aromatics fraction consists of benzene, toluene, xylene, styrene, propenyl benzene, naphthalene, and some of derivatives. Pyrolysis temperature did not affect the ratio of total weight fraction of aliphatic over aromatic hydrocarbon distribution in case of PS only and PE-PS mixtures (1:1 and 1:4 wt. ratio) as a feed while affected the ratio of total wt. fraction in case of PE only. The optimal temperature for the maximum oil production was $600^{\circ}C$ for pyrolysis of PS and 1:1 and 1:4 mixtures of PE and PS. The optimal condition for aromatic recovery was $600^{\circ}C$ with 1:1 mixture of PE and PS. In this condition, aromatic was produced up to 90% of total oil product. The maximum yield of toluene, xylene, styrene, and propenyl benzene were 8.6, 8.9, 51.0 and 7.4% of feed for pyrolysis PS at $700^{\circ}C$, respectively. However, only 1.3% naphthalene was recovered at $700^{\circ}C$ with 1:1 PE:PS(by wt.).

INFLUENCE of SHS-CATALYSTS PHASE STRUCTURE on FORMING PRODUCTS of PARTIAL METHANE OXIDATION

  • Mironenko, A.V.;Rahmetkaliev, K.N.;Mansurov, Z.A.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.278-283
    • /
    • 2000
  • The activity of catalysts obtained by self-propagating high temperature synthesis in reaction of partial methane oxidation at atmospheric pressure was investigated. Basing on the compared results of X-ray analysis and gas chromatography analysis of reaction products, the dependence of compounds formation on the phase concentrations in the studied catalyst samples was found.

  • PDF

Characterization of Volatile Compounds in Low-Temperature and Long-Term Fermented Baechu Kimchi (묵은 배추김치의 휘발성 성분 특성)

  • Kim, Ji-Yun;Park, Eun-Young;Kim, Young-Suk
    • Journal of the Korean Society of Food Culture
    • /
    • v.21 no.3
    • /
    • pp.319-324
    • /
    • 2006
  • Volatile compounds in low-temperature and long-term fermented Baechu kimchi were extracted by high vacuum sublimation(HVS), and then analyzed by gas chromatography/mass spectrometry(GC-MS). A total of 62 compounds, including 7 sulfur-containing compounds, 8 terpenes, 5 esters, 8 acids, 15 alcohols, 2 nitrites, 2 ketones, 11 aliphatic hydrocarbons and 4 miscellaneous compounds, were found in low-temperature and long-term fermented Baechu kimchi. Among them, acetic acid and butanoic acid were quantitatively dominant. Aroma-active compounds were also determined by gas chromatography/olfactometry(GC-O) using aroma extract dilution analysis(AEDA). A total of 16 aroma-active compounds were detected by GC-O. Butanoic acid was the most potent aroma-active compound with the highest FD factor($Log_3FD$) followed by linalool, acetic acid, 2-vinyl-4H-1,3-dithin and 3-methyl-1-butanol. The major aroma-active compounds, such as acetic acid and butanoic acid, were related to sour and rancid or notes.