• 제목/요약/키워드: High temperature belt

검색결과 46건 처리시간 0.03초

산업용 Polyester Belt의 서머졸 염색 (Thermosol Dyeing of Industrial Polyester Belt)

  • 김호정;이문철
    • 한국염색가공학회지
    • /
    • 제11권3호
    • /
    • pp.9-14
    • /
    • 1999
  • To investigate the effect of dyeing conditions, such as pick-up rate, dye concentration, time and temperature in thermosol dyeing on the dyeability of industrial polyester belt, dye uptake and rubbing fastness were measured. The dye uptake was increased with the increase of pick-up rate, dye concentration, dyeing time and temperature. The high rubbing fastness(class 5) for polyester belt dyed with Cibacet Blue F3R at the various conditions was obtained.

  • PDF

벨트의 피복압이 인체 생리에 미치는 영향에 관한 연구 (A Study of Physiological Influence on Human-body According to Clothing Pressure of Belt)

  • 장지혜
    • 대한가정학회지
    • /
    • 제36권6호
    • /
    • pp.85-94
    • /
    • 1998
  • In this study we tested the physiological influence on human-body according to clothing pressure with reduction rate and varied posture using three kinds of belt with different width. The width of belts were 2.5cm, 3.5cm and 4.5cm, and reduction rates of belts were 0%, 2.5% and 5% of the subject/s waist size respectively. the measured postures were standing state and sitting stste in the chair. The reasults are as follows; 1. Clothing pressure was high in the order of Side part>Front part>Back part and the rate fo change in the side part was highest, according to the reductio rate of belts. The more the width of belt was wide, the less the clothing pressure was small, and this kind of phenomenon could be explained by "The Principle of the power". 2. Both the rate of reduction of belt and the change of average skin temperature in accordance with the width of belt is small, however, the more the width of belts is wider and the reduction rate is bigger, the more the skin temperature at the waist part is increased. 3. The blood pressure and pulse was influenced when the width of belt was narrow and the reduction rate was high. 4. A sense restraining was much influenced by the width of belt, especially when the width of belts was wide, the significant difference was permitted.permitted.

  • PDF

Pressure and Temperature Control and HPHT Diamond Synthesis Using FB25 Type Belt Apparatus

  • Fukunaga, O.;Ko, Y.S.;Ohashi, N.
    • The Korean Journal of Ceramics
    • /
    • 제4권1호
    • /
    • pp.5-8
    • /
    • 1998
  • Flat belt(FB) type high pressure apparatus has been succesfully utilized in various high pressure experimental stations in Korea and Japan to conduct HPHT (high pressure and high temperature) diamond synthesis. Present paper discusses pressure calibration of FB apparatus at high temperature to establish P-T condition of diamond synthesis. We also present some examples of controling P-T condition through careful experimental set-up of the high pressure sample cells. Finally we discuss reproducibility of pressure and temperature condition of the HPHT diamond synthesis.

  • PDF

목분 충진 고분자 용융체의 압출다이 내 유동 및 열전달에 관한 수치해석 (Numerical Analysis on the Flow and Heat Transfer Characteristic of Wood-flour-filled Polypropylene Melt in an Extrusion Die)

  • 고승환;박형규;송명호;김찬중
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.311-318
    • /
    • 2001
  • A three-dimensional numerical analysis of the flow and heat transfer characteristic of wood-flour-filled polypropylene melt in an extrusion die was carried out Used for this analysis were Finite Concept Method based on FVM, unstructured grid and non-Newtonian fluid viscosity model. Temperature and flow fields are closely coupled through temperature dependent viscosity and viscous dissipation. With large Peclet, Nahme, Brinkman numbers, viscous heating caused high temperature belt near die housing, Changing taper plate thickness and examining some predefined parameters at die exit investigated the effect of taper plate on velocity and temperature uniformities. In the presence of taper plate, uniformity at die exit could be improved and there existed an optimum thickness to maximize it.

  • PDF

적외선 영상 복사계를 이용한 산간집수역의 찬공기 배수와 온난대 형성 관측 (Observation of the Cold-air Drainage and Thermal Belt Formation in a Small Mountainous Watershed by Using an Infrared Imaging Radiometer)

  • 윤진일
    • 한국농림기상학회지
    • /
    • 제13권2호
    • /
    • pp.79-86
    • /
    • 2011
  • 산간계곡에는 특히 야간에 찬 공기가 흘러 고이는 일이 흔한데, 이런 곳의 식생은 생장과 발육이 그렇지 않은 주변지역에 비해 달라질 수 있어 관심의 대상이 다. 이 연구는 작은 규모의 집수역에서 적외선 영상을 이용하여 냉기호와 온난대의 형상을 가시화 할 수 있는지 알기 위해 수행하였다. 경남 하동군 악양면 형제봉(해발 1,117m)에 적외선 영상 복사계를 설치하여 관측여건이 양호했던 2011년 5월 17일 새벽부터 일출시까지 악양계곡의 열영상을 $640{\times}480$ 해상도로 획득하였다. 열영상 분석결과 계곡의 바닥에 나타난 낮은 온도 분포에 의해 찬공기의 배수를 인지할 수 있었고, 계곡 양쪽 사면에서 바닥보다 $5^{\circ}C$ 높은 온난대의 실체를 확인할 수 있었다. 적외선 영상을 이용하면 기존 고해상도 디지털 기온분포도 '전자기후도'의 신뢰성 검증이 한층 수월해져서 전자기후도 실용성 확보에 도움이 될 것이다.

무창산란계사의 환경분석에 관한 연구 (Environmental Analysis in the Windowless Laying Hen Houses)

  • 이성현
    • Journal of Biosystems Engineering
    • /
    • 제28권3호
    • /
    • pp.225-230
    • /
    • 2003
  • This study was carried out to analyze the environmental variation of layer house at Iowa State in the USA. The analyzed seasons for this study were summer and winter. Analyzing factors are inside temperature and relative humidity, carbon dioxide concentration, ammonia concentration and emission. All factors were collected every 30 second from each house with portable monitoring units. In this study, two types of laying hen houses were monitored at the same season. One was a manure belt house, the other was a high-rise house. In order to estimate the ventilation rates of the laying hen houses, carbon dioxide concentration balance was used in this study. Ammonia concentrations and emission rates of the manure belt house are much lower than those of the high rise house. Daily mean ammonia concentrations in the manure belt house and high-rise house ranged from 3 to 7 ppm and 5 to 34 ppm, respectively. The daily ammonia emission rates averaged 0.68g/h$\cdot$500kg and 0.73g/h$\cdot$500kg for the manure belt house and 0.93g/h$\cdot$500kg and 2.89g/h$\cdot$500kg for the high-rise house in summertime and wintertime, respectively. Summertime is associated with much higher ammonia emission rates than wintertime because of much higher ventilation rates and ambient air temperature, even though the concentrations may be lower.

목분 충진 고분자 용융체의 압출다이 내 유동 및 열전달에 관한 수치해석 (Numerical Analysis on the Flow and Heat Transfer Characteristic of Wood-flour-filled Polypropylene Melt in an Extrusion Die)

  • 고승환;박형규;송명호;김찬중
    • 대한기계학회논문집B
    • /
    • 제27권2호
    • /
    • pp.147-154
    • /
    • 2003
  • A three-dimensional numerical analysis of the flow and heat transfer characteristic of wood-flour-filled polypropylene melt in an extrusion die was carried out. Used for this analysis were Finite Concept Method based on FVM, unstructured grid and non-Newtonian fluid viscosity model. Temperature and flow fields are closely coupled through temperature dependent viscosity and viscous dissipation. With large Peclet, Nahme, Brinkman numbers, viscous heating caused high temperature belt near die housing. Changing taper plate thickness and examining some predefined parameters at die exit investigated the effect of taper plate on velocity and temperature uniformities. In the presence of taper plate, uniformity at die exit could be improved and there existed an optimum thickness to maximize it.

극지 운항 선박 Ice Belt Zone의 도장 사양 설계 연구 (A Study on Coating Performance Design for Ice Belt Zone of the Arctic Vessels)

  • 백윤호;박충서;소용신
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2013년도 특별논문집
    • /
    • pp.66-72
    • /
    • 2013
  • The demand for an ice class ship is rising expected to rise according to the increase of energy consumption and the opening of arctic sea routes. Ice class ship should be designed to cope with the severe environmental conditions of arctic sea such as a high mechanical impact and abrasion damage, caused by pack ice, ice bergs and low temperature. The ice class ship hulls are coated with an anti-abrasion and low friction coating such as a solvent free epoxy or high solid-volume epoxy. These coatings require two-component heating pump and a high grade surface preparation. In this study, the coating performances for the arctic vessels, such as puncture absorbed energy, abrasive wear loss, friction coefficients and impact absorbed energy were evaluated. Based on this study, a proper coating performance specification for the arctic vessels was proposed and coating selection guideline in terms of coating performance and workability was also established.

  • PDF

Experimental Test on the Effect of Onsite Welding of Steel Plates for a Joint Between Concrete Columns and a Steel Belt Truss

  • Shim, Hak Bo;Yun, Da Yo;Park, Hyo Seon
    • 국제초고층학회논문집
    • /
    • 제9권2호
    • /
    • pp.155-166
    • /
    • 2020
  • To connect exterior reinforced concrete (RC) columns with the steel belt truss, the gusset plates are welded to the steel plates embedded in the RC column. Then, the concrete around an embedded plate is very likely to be damaged by the heat input from a long-time (6 to 48 hours) welding of the embedded and gusset plates at a joint between RC columns and steel belt truss. However, very few studies have assessed the concrete damage caused by the welding heat between embedded and gusset plates, and no clear onsite solution has been found. In this paper, experimental tests have been carried out on 4 full-scale specimen to analyze the effect of long-time (about 6 hours) onsite welding (1-side welding and 3-side welding) between a gusset plate and an embedded plate in high strength concrete with compressive strength of 55 MPa and 80 MPa on RC columns. The effect of the long-time welding heat of embedded and gusset plates, which are used in real high-rise building construction sites, on concrete is analyzed in terms of the following three items: 1) temperature distribution, 2) pattern and characteristics of cracks, and 3) effect of the cracks on the compressive strength of RC column. Based on the experimental results, even though the heat input up to about 150? from the long-time onsite welding on the high-strength concrete column for the joint could result in concrete cracks in a radial form, it is found that the welding cracks have no effect on the axial stiffness and strength of the concrete column.

도시의 기온 분석을 통한 지역별 열 환경 특성 해석과 동·하절기 계절 간 비교연구 (Comparison Study on Thermal Environment Characteristics in Each Region and the Seasons of Summer and Winter Through Air Temperature Analysis in Urban Areas)

  • 최동호;이부용
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.83-93
    • /
    • 2012
  • This study is to perform the effect of urbanization in urban and suburban districts, and to identify regional characters of climate according to the analysis of slope at rise, and descent of temperature and globe temperature, correlation between seasonal temperature analysis, and calculation of degree hour. According to this study, the result is summarized as follows. (1) The average temperature, rated from high to low, consists of residential area, Daegu weather station, intracity, green belt, water-front green belt, and suburban. (2) At the rise and descent of temperature, the result of the slope change of in each point may be one of the useful indexes to be able to perform the regional unique thermal characteristic, including the seasonal urbanization. (3) Although there is a difference between the surface of the earth and ambient environment. The result of the correlation of temperature between summer and winter is that temperature slope in urban districts was higher than in suburban districts, and the difference of slope was unvaried among the four observations in the same city region. (4) To show objectively, regional thermal characteristics in urban and suburban districts, the exponentiation of winter degree hour and summer degree hours were checked. The result of the exponentiation is that the more artificial a region, the lower index.