ANALYSES ON FLOW FIELDS AND PERFORMANCE OF A CROSS-FLOW FAN WITH VARIOUS SETTING ANGLES OF A STABILIZER

  • Kim D. W.;Kim H. S.;Park S. K.;Kim Youn J
    • Journal of computational fluids engineering
    • /
    • v.10 no.1
    • /
    • pp.107-112
    • /
    • 2005
  • A cross-flow fan is generally used on the region within the low static pressure difference and the high flow rate. It relatively makes high dynamic pressure at low rotating speed because a working fluid passes through an impeller blade twice and blades have a forward curved shape. At off-design points, there are a rapid pressure head reduction, a noise increase and an unsteady flow. Those phenomena are remarkably influenced by the setting angle of a stabilizer. Therefore, it should be considered how the setting angle of a stabilizer affects on the performance and the flow fields of a cross-flow fan. It is also required to investigate the effect of the volumetric flow rate before occurring stall. Two-dimensional, unsteady governing equations are solved using a commercial code, STAR-CD, which uses FVM. PISO algorithm, sliding grid system and standard k - ε turbulence model are also adopted. Pressure and velocity profiles with various setting angles are graphically depicted. Furthermore, the meridional velocity profiles around the impeller are plotted with different flow rates for a given rotating speed.

Performance Estimation of Cross-Flow Fan by Numerical Method (수치해석적 기법을 이용한 횡류홴 성능 평가)

  • Kim, D.-W.;Lee, J.-H.;Park, S.-K.;Kim, Youn-J.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.152-157
    • /
    • 2002
  • A cross-flow fan is widely used on many industrial fields: a blower for the general industry, mining industry, automobile and home appliances. The design point of the cross-flow fan is generally chosen by based on the region within low static pressure and high flow rate. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice. However, it has low static pressure efficiency between $30\%$ and $40\%$ because of relative high impact loss. Recently, in the air-conditioning systems, the operating behaviors at the off-design points are highly regarded to broaden the application area for various air-cooling loads. Especially, at the low flow rate, there exists a rapid pressure head reduction, a noise increase and an irregular flow against a rearguider as a scroll of centrifugal fan. Numerical analyses are carried out for cross-flow fan including the impeller, the rearguider and the stabilizer. Numerical domains are discretized by hexahedral cells. Three-dimensional, unsteady governing equations are solved using FVM, SIMPLE algorithm, sliding grid system and standard k-$\epsilon$ turbulence model.

  • PDF

The design concept of the cubicle to improve freezing performance for high speed train (고속열차 배전반의 냉각성능 신뢰성 향상 방법에 대한 연구)

  • Choi, Kwon-Hee;Jeong, Byung-Ho;Lee, Byung-Seok;Park, Jong-Hun;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.905-910
    • /
    • 2007
  • The cubicle of high speed train is the equipment where the important train- operating equipments are concentrated, so it requires the higher safety and reliability than any other equipment. Recently, the power car cubicle of KTX-II is, basically similar to that of KTX-I and HSR350x in its size, but consequently, as more sophisticated ATP/ATC and other parts are added, the order company points out the problem of rising temperature in summer. Especially, the interpretation about the possibility of guaranteeing the minimum freezing performance becomes necessary, when Fan Tray is out of order. This paper presents the method of improving the freezing performance while minimizing the effect of dust, and the method of guaranteeing the present freezing performance by the best arrangement of Fan Tray, when Fan Tray is out of order. And as a method of verifying this, we would like to predict the pressure, speed of a running fluid and temperature distribution of cubicle through the flow analysis.

  • PDF

An Analysis of the Unsteady Flow-Field and Aerodynamic Sound of a Turbo Fan used in a Vacuum Cleaner (청소기용 터보홴의 비정상 유동장 및 공력소음 해석)

  • Jeon, Wan-Ho;Kim, Chang-Joon;Rew, Ho-Seon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.5 no.2 s.15
    • /
    • pp.36-42
    • /
    • 2002
  • A new method to calculate the aeroacoustic pressure of a centrifugal fan that is used in a vacuum cleaner has been developed. The centrifugal fan consists of the impeller, the diffuser, and the circular casing. Due to the high rotating speed of the impeller and the small gap distance between the impeller and diffuser, the centrifugal fan makes very high noise levels at BPF and its harmonic frequencies. In order to calculate the sound pressure of a centrifugal fan, the unsteady flow field data is needed. This unsteady flow field is calculated by the vortex method. The sound pressure is then calculated by acoustic analogy. In this paper, only dipole term is considered in the equation. The noise generated by moving impeller and stationary diffuser is calculated separately. The predicted acoustic pressures agree very well with the measured data. The difference between the two is less than 4dB

Design and Drive Characteristics of Low Voltage 8/6 SRM for Fan Application (팬구동용 저압 8/6 SRM의 설계 및 구동 특성)

  • Ahn, Jin-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1371-1376
    • /
    • 2014
  • In this paper, 4-phase switched reluctance motor(SRM) with 8-stator and 6-rotor pole structure is proposed for a high speed fan with a low voltage. The air blower has unidirectional rotation characteristics and requires a low torque ripple and noise as well as high efficiency. To achieve the requirements, voltage and current according to loading condition of limited specification is considered. Design process is to select the bore diameter, pole arc, york of stator and rotor to get a high torque and efficiency. To verify the validity of the proposed structure, finite element method(FEM) is employed to get the performances. And the converter for the proposed SRM is employed a 1.5q power converter for cost effectiveness. Prototype SRM is manufactured and tested, and the test results show this design is within the specification and good for the air blower applications.

The Cooling System for Head up Display (Head up Display용 냉각시스템)

  • Ji, Youg-Seok;Kim, Young-Seop;An, Byeong-Man;Lim, Sang-Min
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.1
    • /
    • pp.67-71
    • /
    • 2010
  • Head up display’s cooling system is auto-diagnosed resulting from the external environment. The quantity of heat depending on this Head up display’s cooling system layout determines the speed of FAN for system cooling. In other words, a system’s heat quantity is planned through the air density depending on altitude, the amount of wind in air depending on FAN control condition, and the algorithm that is proportional to delta temperature. To detect the altitude, we use the criteria of delta T, which is determined by the subtracted value of LED junction temperature, and atmospheric temperature that is recorded on the Head up display system. Depending on the classification of delta T value, the altitude section is determined. While we can use GPS as the tool to detect the altitude, we should predict the change of the air density as the altitude alters, and should not just measure the altitude. And the value of delta T is used as the criterion of detecting the altitude for increasing the cooling efficiency of the car’s inner Head up display system with reflecting the speed of the FAN dependent upon the air density. In our theory, altitude is depending on the value of delta T and stabilizing or maintaining the system’s temperature by changing FAN’s rpm depending on determined value of altitude.

Size Distribution of Droplets Sprayed by an Orchard Sprayer (과수방제기 살포입자의 직경 분포특성)

  • 구영모;신범수;김상헌
    • Journal of Biosystems Engineering
    • /
    • v.26 no.5
    • /
    • pp.431-440
    • /
    • 2001
  • Generated agri-chemical droplets by orchard sprayers are evaporated regenerated and transported along wind streams. The droplets are deposited to targets after changing their sizes, affecting the retention of droplets. An orchard sprayer, designed for spraying grapevines was studied on the spatial distribution of droplet size. The experimental variables were spray direction (0, 22.5, 45, 67.5 and 90˚), distance(2.5, 3.0 and 3.5 m) and fan speed (2,075 and 3,031 rpm). Droplet sizes were converted and analyzed from spray stains, sampled using water sensitive papers. The number median diameter (NMD) increased with an increase of the distance due to disappeared fine droplets (<50 ㎛): however, the volume median diameter (VMD) decreased due to shrunken large droplets (>100 ㎛). Fast fan speed delivered large droplets to 3.5 m, but the spatial distributions of NMD and VMD were not uniform. Slower fan speed decreased the possibility of evaporation and drift; therefore, plenty of droplets were maintained up to 3.0 m. The upward blasting distance was limited within 3 m, but the limit to the ground level was extended to 3.5 m. Concentrated wind and droplets to the ground level should be redistributed to upper canopy direction, leading more uniform deposits. High speed wind and system pressure should be avoided because of generating fine droplets, which would be disappeared and drifted away.

  • PDF

AN INVESTIGATION ON HVLS FAN PERFORMANCE WITH DIFFERENT BLADE CONFIGURATIONS (날개 형상에 따른 HVLS의 성능에 관한 연구)

  • Moshfeghi, Mohammad;Hur, Nahmkeon;Kim, Young Joo;Kang, Hyun Wook
    • Journal of computational fluids engineering
    • /
    • v.19 no.4
    • /
    • pp.80-85
    • /
    • 2014
  • High-volume low-speed (HVLS) fans are one category of ceiling fan installed in large enclosings such as warehouses, large barns and health clubs in order to generate comfortable air circulation. As a rotary blade, aerodynamic performance of a HVLS fan is predominantly related to its airfoil(s), and the pitch and twist angles. This paper first, investigates the effects of airfoil on the performances of three different HVLS fans with NACA 5414, 6413 and 7415 airfoils. The fans have six untwisted blades with the diameter of 6 m and rotate at 60 RPM. The blades pitch angels are $12^{\circ}$, $12^{\circ}$ and $13^{\circ}$, respectively. The results are presented in the form of the aerodynamic forces and moments, volumetric flow rate and streamlines. Regarding the volumetric flow of air, the results show that the model with NACA 7415 has the best performance. Hence, two other HVLS fans with the same airfoil but, with four and five blades are studied in order to investigate the effects of number of blades. From the point of view of air circulation still the six-bladed fan is the best one; however, the five-bladed fan is more efficient in power consumption.

Aerodynamic Design of Slim and High-efficient Turbo-Fan (박판형 고효율 터보홴의 공력학적 설계)

  • Lee, Myeong-Jae;Kim, Nam-Uk;Park, Duck-Jun;Cho, In-Soo;Lee, Seung-Bae
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2600-2605
    • /
    • 2008
  • Turbo-fans for a FFU unit should be aerodynamically designed to provide the FFU system with the given flow-rate at the lowest rotational-speed by considering the interaction effect with the FFU casing. In this study, slim and highly efficient turbo-fans are designed to satisfy the given performance at the specific speed by using the hybrid-stacking method of an inducer and a 2D-bladed turbo fan. The mean-line analysis, cascade theory, and CFD technique are all together applied to control the passage areas on the meridional plane from the inlet to the exit of the blade. Furthermore, the torque control algorithm is adopted to improve the performances within the constraints by the motor rpm-torque characteristics, and the resulting measured performances of mock-up fans are discussed.

  • PDF

Performance of a Cross-Flow Fan with Various Stabilizer Positions and Rearguider Shapes (스태빌라이져 위치 및 리어가이더 형상변화에 따른 횡류홴의 성능특성 연구)

  • Kim, D.W.;Kim, H.S.;Yoon, T.S.;Park, S.K.;Kim, Yon J.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.4 s.25
    • /
    • pp.7-15
    • /
    • 2004
  • The design point of the cross-flow fan is generally based on the region within low static pressure and high flow rate. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice. However, it has low static pressure efficiency between $30\%$ and $40\%$ because of relative high impact loss. The purpose of this study is to research the reciprocal relation among each parameter. Experiments and numerical analyses are conducted on effects of a stabilizer and a rearguider on performance analysis of a cross-flow fan. Two-dimensional, unsteady governing equations are solved using FVM, PISO algorithm, sliding grid system and standard $k-{\epsilon}$ turbulence model. Experiments are also carried out to estimate the performance of the modeled cross-flow fan. It is clarified that the rearguider of Archimedes type has excellent results for the most part.