Browse > Article
http://dx.doi.org/10.5293/KFMA.2004.7.4.007

Performance of a Cross-Flow Fan with Various Stabilizer Positions and Rearguider Shapes  

Kim, D.W. (성균관대학교 대학원)
Kim, H.S. (성균관대학교 대학원)
Yoon, T.S. (삼성전자 DA연구소)
Park, S.K. (삼성전자 DA연구소)
Kim, Yon J. (성균관대학교)
Publication Information
Abstract
The design point of the cross-flow fan is generally based on the region within low static pressure and high flow rate. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice. However, it has low static pressure efficiency between $30\%$ and $40\%$ because of relative high impact loss. The purpose of this study is to research the reciprocal relation among each parameter. Experiments and numerical analyses are conducted on effects of a stabilizer and a rearguider on performance analysis of a cross-flow fan. Two-dimensional, unsteady governing equations are solved using FVM, PISO algorithm, sliding grid system and standard $k-{\epsilon}$ turbulence model. Experiments are also carried out to estimate the performance of the modeled cross-flow fan. It is clarified that the rearguider of Archimedes type has excellent results for the most part.
Keywords
Cross-Flow Fan; Stabilizer; Archimedes Spiral; Rear-guider; Gap; Setting Angle;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Tsurusaki, H., Tsujimoto, Y., Yoshida, Y. and Kitagawa, K., 1997, 'Visualization Measurement and Numerical Analysis of Internal Flow in Cross-Flow Fan' , Journal of Fluids Engineering, Vol. 119, pp.33-638
2 Gabi, M. and Klemm, T., 2003 , 'Numerical and Experimental Investigations of Cross Flow Fan' , the 12th International Conference on Modeling Fluid Flow, pp. 1214-1219
3 Murata, S. and Nishihara , K., 1976 , 'An Experimental Study of Cross Flow Fan (1st Report , Effects of Housing Geometry on the Fan Performance)' , JSME, Vol. 19, No. 129
4 Tanaka, S. and Murata, S., 1995, 'Scale Effects in Cross-Flow Fans' , JSME International Journal series B, Vol. 38, No.3, pp. 388-397
5 구형모, 최원석, 오병재, 이진교, 1998, '공조기기용 횡단류팬에 대한 실험적 연구: 기본적 설계변수의 영향에 관한 연구', 대한기계학회 춘계학술대회 논문집 B, pp. 438-443
6 Japikse, D., 1984, Turbomachinery Diffuser Design Technology: The Design Technology Series (DTS-1), Concepts ETI, Inc
7 허남건, 김욱, 강신형, 1999, '직교류 홴의 유동 해석: 깃 형상 변화가 성능에 미치는 영향', 유채 기계저널: 제2권 , 제1호, pp. 96-102
8 진심원, 이진하, 서상호, 이내영, 임금식, 1995, '에어콘용 횡류팬의 고풍량화에 대한 실험적 연구', 공기조화냉동공학회, 동계학술발표논문집, pp. 234-241
9 Gabi, M. and Klemm, T., 2003 , 'Numerical and Experimental Investigations of Cross Flow Fan' , the 12th International Conference on Modeling Fluid Flow, pp. 1214-1219
10 Eck, B., 1973, Fans: Design and Operation of Centrifugal, Axial-Flow and Cross- Flow Fan, Pergamon Press, New York
11 Yamafuji, S. and Nishihara , K., 1976 , 'An Experimental Study of Cross Flow Fan' , Bulletin of JSME, Vol. 19, No. 129, pp. 314-321
12 Tsurusaki, H., Shimizu, H., Tsujimoto, Y. and Yoshida, Y. 1996, 'Study of Cross-Flow Fan Internal Flow by Flow', JSME International Journal , series B, Vol. 39, pp. 540- 545
13 CD-adapco, 1999 , STAR-CD Methodology v3.100 , Computational Dynamics LTD