• Title/Summary/Keyword: High separation efficiency

Search Result 403, Processing Time 0.032 seconds

Fabrication and Simulation of Fluid Wing Structure for Microfluidic Blood Plasma Separation

  • Choe, Jeongun;Park, Jiyun;Lee, Jihye;Yeo, Jong-Souk
    • Applied Science and Convergence Technology
    • /
    • v.24 no.5
    • /
    • pp.196-202
    • /
    • 2015
  • Human blood consists of 55% of plasma and 45% of blood cells such as white blood cell (WBC) and red blood cell (RBC). In plasma, there are many kinds of promising biomarkers, which can be used for the diagnosis of various diseases and biological analysis. For diagnostic tools such as a lab-on-a-chip (LOC), blood plasma separation is a fundamental step for accomplishing a high performance in the detection of a disease. Highly efficient separators can increase the sensitivity and selectivity of biosensors and reduce diagnostic time. In order to achieve a higher yield in blood plasma separation, we propose a novel fluid wing structure that is optimized by COMSOL simulations by varying the fluidic channel width and the angle of the bifurcation. The fluid wing structure is inspired by the inertial particle separator system in helicopters where sand particles are prevented from following the air flow to an engine. The structure is ameliorated in order to satisfy biological and fluidic requirements at the micro scale to achieve high plasma yield and separation efficiency. In this study, we fabricated the fluid wing structure for the efficient microfluidic blood plasma separation. The high plasma yield of 67% is achieved with a channel width of $20{\mu}m$ in the fabricated fluidic chip and the result was not affected by the angle of the bifurcation.

Effect of separation walls on reduction of suspended solids loading in a combined sewer system (합류식 하수관거내 우오수분리벽 설치에 따른 부유물질 제어효과)

  • Kwon, Chungjin;Lim, Bongsu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.787-796
    • /
    • 2012
  • The purpose of this study is to investigate CSOs(combined sewer overflows) control in the combined sewer with/without separation wall. There is the high correlation between sewage velocity and suspended solid(SS) loading in the sewer without it. The SS/BOD ratio was about 3 times in the area with it, while it was about 5 times in the area without it. Therefore, the accumulated deposit within the sewer has influenced high SS loading in the sewer without it. This study showed that the separation wall installed acquired an acceptable efficiency in controlling the accumulated deposit in the combined sewer. According to this study, the BOD control effect was about 38 % in the sewer with the separation wall, whereas it showed about 24 % in the sewer without it. In this case, it was anticipated that the high pollutant control effect would be expected if the separation wall was installed in the combined sewer.

Treatment of rolling cooling waste water by superconductor HGMS method (초전도 자기분리에 의한 냉연공정 폐수처리)

  • Kim, Tae-Hyung;Ha, Dong-Woo;Oh, Sang-Soo;Kim, Young-Hun;Ha, Tae-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.295-295
    • /
    • 2008
  • This study introduced waste water treatment method applied superconductor HGMS(High Gradient Magnetic Separation). HGMS method treat high efficient method for various waste water. we have surveyed superconducting magnetic separation technology and reviewed the status of related industries using applied superconductivity. We fabricated the prototypes of magnetic matrix filter consisting of stainless steel mesh, which is a core component in the magnetic separation system. In our basic preliminary experiment using HGMS, it was made clear that the fine para-magnetic particles in the rolling colling wasted water obtained from rolling process of POSCO can be separated with high efficiency.

  • PDF

Simulated Moving Bed [SMB] (모사 이동층 크로마토그래피)

  • Lee Chong-Ho;Koo Yoon-Mo
    • KSBB Journal
    • /
    • v.20 no.3
    • /
    • pp.192-196
    • /
    • 2005
  • Chromatography has been a method of choice in the separation of complex biological mixtures for the analytical purpose in particular for the last half of century. In current years, chromatographic method extends its use to the preparative separation where the productivity per resin amount and solvent use become a matter of concern. Recently, simulated moving bed (SMB) method which claims high separation efficiency of the ideal counter-current moving bed chromatography has become a workhorse of preparative separation. SMB technology was developed in the early 1960s for large-scale hydrocarbon separation by UOP and approximately 120 Sorbex units have been licensed to date. Recently, SMB separation technology has been successfully extended from hydrocarbons and sugars to fine chemicals, particularly biochemicals, from laboratory to pilot to production plant. In this paper, the current status of SMB and its modifications were reviewed.

Application Status and Prospect of Magnetic Separation Technology for Wastewater Treatment (폐수처리 분야에서 자기 분리기술의 응용 현황 및 전망)

  • Chu, Shaoxiong;Lim, Bongsu;Choi, Chansoo
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.2
    • /
    • pp.153-163
    • /
    • 2020
  • Magnetic separation technology is an efficient and environmentally friendly technology. Compared with the traditional wastewater treatment technology, the magnetic separation technology has its unique advantages and characteristics, and has been widely applied in the field of wastewater treatment. In particular, the emergence of superconducting magnetic separation technology makes possible for high application potential and value. In this paper, which through consulting with the literatures of Korea, Chinese, United States and other countries, the magnetic separation technology applied to wastewater treatment was mainly divided into direct application of magnetic field, flocculation, adsorption, catalysis and separation coupling technology. Advantages and limitations of the magnetic separation technology in sewage treatment and its future development were also studied. Currently, magnetic separation technology needs to be studied for additional improvement in processing mechanism, design optimization of magnetic carrier and magnetic separator, and overcoming engineering application lag. The selection, optimization and manufacturing of cheap magnetic beads, highly adsorbed and easily desorbed magnetic beads, specific magnetic beads, nanocomposite magnetic beads and the research of magnetic beads recovery technology will be hot application of the magnetic separation technology based on the magnetic carriers in wastewater treatment. In order to further reduce the investment and operation costs and to promote the application of engineering, it is necessary to strengthen the research and development of high field strength using inexpensive and energy-saving magnet materials, specifically through design and development of new high efficiency magnetic separators/filters, magnetic separators and superconducting magnetic separators.

Coagulation-membrane separation hybrid treatment of secondary treated effluent for high efficiency phosphorus removal (하수 2차처리 방류수의 총인 고효율 처리를 위한 응집·막분리 혼성처리)

  • Choi, Wookjin;Lee, Byungha;Park, Joonhong;Cha, Hoyoung;Lee, Byungchan;Song, Kyungguen
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.1
    • /
    • pp.47-53
    • /
    • 2018
  • This study investigated phosphorus removal from secondary treated effluent using coagulation-membrane separation hybrid treatment to satisfy strict regulation in wastewater treatment. The membrane separation process was used to remove suspended phosphorus particles after coagulation/settlement. Membrane separation with $0.2{\mu}m$ pore size of micro filtration membrane could reduce phosphorus concentration to 0.02 mg P/L after coagulation with 1 mg Al/L dose of polyaluminum chloride (PACl). Regardless of coagulant, the residual concentration of phosphorus decreased as the dose increased from 1.5 to 3.5 mg Al/L, while the target concentration of 0.05 mg P/L or less was achieved at 2.5 mg Al/L for the aluminum sulfate (Alum) and 3.5 mg Al/L for PACl. Moreover, alum showed better membrane flux as make bigger particles than PACl. Alum showed a 40% of flux decrease at 2.5 mg Al/L dose, while PACl indicated a 50% decrease of membrane flux even with a higher dose of 3.5 mg Al/L. Thus, alum was more effective coagulant than PACl considering phosphorus removal and membrane flux as well as its dose. Consequently, the coagulation-membrane separation hybrid treatment could be mitigate regulation on phosphorus removal as unsettleable phosphorus particles were effectively removed by membrane after coagulation.

Integrated Hybrid Device for High-Efficiency Size-Tunable Particle Separation (고효율 크기 가변적 입자 분리를 위한 통합 하이브리드 소자)

  • Choo, Seung Hee;Park, Jion;Kim, Tae Eun;Gang, Tae Gyeoung;An, Jun Seok;Oh, Gayeong;Kim, Yeojin;Park, Kyu Been;Park, Chaewon;Lee, Minjeong;Lim, Hyunjung;Nam, Jeonghun
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.170-176
    • /
    • 2022
  • Cell separation from a heterogenous mixture sample is an essential process for downstream analysis in biological, chemical, and clinical applications. This study demonstrates an integrated hybrid device of the viscoelastic focusing in a straight rectangular channel and subsequent size-based separation using acoustophoresis to attain high efficiency and separation tunability. For particle pre-alignment in a viscoelastic fluid, the flow rate higher than 10 μl/min was required. Surface acoustic wave-based lateral migration of particles with different sizes (13 and 27 ㎛) was examined at various applied voltages and flow rate conditions. Therefore, the flow rate of 100 μl/min and the applied voltage of 20 Vpp can be used for size-based particle separation.

A Hydraulic and Feasibility Study of New Tower Internal in Gas Processing Plants

  • Choo Chang-upp
    • International Journal of Safety
    • /
    • v.3 no.1
    • /
    • pp.15-19
    • /
    • 2004
  • A new tower internal, which is called CSE, is presented. The CSE is composed of a nozzle perforated in its bottom along the entire periphery and equipped with a multi vane axial swirler at the inlet and hollow cylindrical separator at the outlet of the nozzle. According to the experimental work for obtaining the necessary hydraulic information of the CSE, which is used for preliminary design of a separation column, the CSE showed a stable operation over the wide rage of gas/liquid ratio. However, it caused large pressure drop due to the high gas velocity which should carry liquid droplets through the element. The high pressure drop may cause problems in energy recovery and the application of the CSE can be limited to the high pressure columns. Assuming that the tray efficiency of the CSE is the same with the existing separation columns, the results of the column design showed the size reduction of the column diameters by 30 to $40\%$ and investment cost saving, depending on operating conditions. The application of the CSE to separation column may also contribute to the de-bottlenecking the existing column.

Treatment of steelmaking process waste water by superconductor HGMS method (초전도 HGMS법에 의한 제철공정 폐수처리)

  • Kim Tae-Hyung;Ha Dong-Woo;Oh Sang-Soo;Ha Hong-Soo;Park Sung-Kook;Lee Sang-Gil;Noh Yu-Mi
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.3
    • /
    • pp.41-44
    • /
    • 2006
  • This study introduced waste water treatment method by superconducting HGMS(High Gradient Magnetic Separation). HGMS treatment method is high efficient method for various waste water, we have surveyed superconducting magnetic separation technology. We fabricated the prototypes of magnetic matrix filter consisting of stainless steel mesh, which is a core component in the magnetic separation system. In our basic preliminary experiment using HGMS, it was made clear that the fine para-magnetic particles in the wasted water obtained from steelmaking process of POSCO can be separated with high efficiency.

Evaluation of Initial Collision-Attachment Coefficient and Flotation Characteristics Using Population Balance in Microbubble Flotation Process for Microplastics Separation (미세플라스틱 분리를 위한 미세기포 부상공정에서 개체군수지를 이용한 초기 부착 계수 및 부상특성의 평가)

  • Jung, Heung Joe;Lee, Jae Wook;Kwak, Dong Heui
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.1
    • /
    • pp.10-19
    • /
    • 2021
  • In the flotation process to remove microplastic (MP) particles, the attachment and separation efficiency is determined by the basic physicochemical characteristics of MP particles as well as bubbles. To evaluate the flotation characteristics of MP particles, we carried out a series of simulations using the population balance (PB) model. The initial attachment coefficient (αo) of MP particles was in the range of 0.2-0.275, and it was slightly lower than that of typical particles, such as clay, debris and algae particles, which exist in water bodies, αo, 0.3-0.4. The relative bubble number (RBN) attached to the surface of the typical number of bubbles was 0.30 and 0.32 for MP 30 ㎛ and MP 58 ㎛, respectively. In comparison, the RBN of larger MP particles (138 ㎛) was as high as 0.53. Furthermore, smaller microbubbles were required to separate properly or additional treatment needed to be applied to enhance collision and attachment efficiency since the flotation of MP particles was found to be difficult to treat as high-rate. As a result of comparing the removal rate (experimental value) of MP particles obtained from the batch-type flotation apparatus and the flotation removal rate (predicted value) of MP obtained through the PB model, the final particles by the particle size of MP overall except for the initial separation time area. With respect to the removal efficiency, the observed and predicted values were similar, and it was confirmed that the floating separation characteristics and evaluation of the MP particles through the PB model could be possible.