• Title/Summary/Keyword: High separation efficiency

Search Result 406, Processing Time 0.031 seconds

Enhanced Photocatalytic Properties of Visible Light Responsive La/TiO2-Graphene Composites for the Removal of Rhodamin B in Water

  • Areerob, Yonrapach;Oh, Won-Chun
    • Journal of the Korean Chemical Society
    • /
    • v.61 no.4
    • /
    • pp.168-178
    • /
    • 2017
  • $La/TiO_2$ - graphene composites were synthesized in this study, and applied to the photocatalytic degradation of Rhodamine B (RhB) under UV-visible light irradiation. X-ray diffraction (XRD), surface analysis, X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM), and Transmission electron microscopy (TEM) analysis demonstrated that $La/TiO_2$ nanoparticles were well distributed on the surface of graphene, and formed the heterostructure of $La/TiO_2$-graphene. Compared to the pure $TiO_2$, $La/TiO_2$-graphene composites displayed much higher photocatalytic activities in RhB degradation under UV-visible light irradiation. The photocatalytic data of $La/TiO_2$-graphene composites exhibit extended light absorption in the visible light region, and possess better charge separation capability than that of pure $TiO_2$. The high photocatalytic activity was attributed to the composite's high adsorptivity, extended light absorption, and increased charge separation efficiency, due to the excellent electrical properties of graphene, and the large surface contact between graphene and $La/TiO_2$ nanoparticles.

The Separation and Recovery of Nickel and Lithium from the Sulfate Leach Liquor of Spent Lithium Ion Batteries using PC-88A

  • Nguyen, Viet Tu;Lee, Jae-Chun;Jeong, Jinki;Kim, Byung-Su;Pandey, B.D.
    • Korean Chemical Engineering Research
    • /
    • v.53 no.2
    • /
    • pp.137-144
    • /
    • 2015
  • The present paper deals with the extractive separation and selective recovery of nickel and lithium from the sulfate leachate of cathode scrap generated during the manufacture of LIBs. The conditions for extraction, scrubbing and stripping of nickel from lithium were optimized with an aqueous feed containing $2.54kg{\cdot}m^{-3}$ Ni and $4.82kg{\cdot}m^{-3}$ Li using PC-88A. Over 99.6% nickel was extracted with $0.15kmol{\cdot}m^{-3}$ PC-88A in two counter-current stages at O/A=1 and pH=6.5. Effective scrubbing Li from loaded organic was systematically studied with a dilute $Na_2CO_3$ solution ($0.10kmol{\cdot}m^{-3}$). The McCabe-Thiele diagram suggests two counter-current scrubbing stages are required at O/A=2/3 to yield lithium-scrubbing efficiency of 99.6%. The proposed process showed advantages of simplicity, and high purity (99.9%) nickel sulfate recovery along with lithium to ensure the complete recycling of the waste from LIBs manufacturing process.

NEAR INFRARED TRANSFLECTANCE SPECTROSCOPY (NIRS) IN PHYTOCHEMISTRY

  • Huck, C.W.;W.Guggenbichler;Bonn, G.K.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3114-3114
    • /
    • 2001
  • During the last years phytochemistry and phytopharmaceutical applications have developed rapidly and so there exists a high demand for faster and more efficient analysis techniques. Therefore we have established a near infrared transflectance spectroscopy (NIRS) method that allows a qualitative and quantitative determination of new polyphenolic pharmacological active leading compounds within a few seconds. As the NIR spectrometer has to be calibrated the compound of interest has at first to be characterized by using one or other a combination of chromatographic or electrophoretic separation techniques such as thin layer chromatography (TLC), high performance liquid chromatography (HPLC), capillary electrophoresis (CE), gas chromatography (GC) and capillary electrochromatography (CEC). Both structural elucidation and quantitative analysis of the phenolic compound is possible by direct coupling of the mentioned separation methods with a mass spectrometer (GC-MS, LC-MS/MS, CE-MS, CEC-MS) and a NMR spectrometer (LC-NMR). Furthermore the compound has to be isolated (NPLC, MPLC, prep. TLC, prep. HPLC) and its structure elucidated by spectroscopic techniques (UV, IR, HR-MS, NMR) and chemical synthesis. After that HPLC can be used to provide the reference data for the calibration step of the near infrared spectrometer. The NIRS calibration step is time consuming, which is compensated by short analysis times. After validation of the established NIRS method it is possible to determine the polyphenolic compound within seconds which allows to raise the efficiency in quality control and to reduce costs especially in the phytopharmaceutical industry.

  • PDF

Analysis of Efficiency Enhancement of the Integrated Gasification Combined Cycle with Oxy-Combustion Carbon Capture by Changing the Oxygen Supply System (순산소연소 이산화탄소 포집을 적용한 석탄가스화 복합화력 발전시스템에서 산소공급방식 변경에 의한 효율향상 분석)

  • CHO, YEON WOO;AHN, JI HO;KIM, TONG SEOP
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.4
    • /
    • pp.347-355
    • /
    • 2019
  • As a solution to the growing concern on the global warming, researches are being actively carried out to apply carbon dioxide capture and storage technology to power generation systems. In this study, the integrated gasification combined cycle (IGCC) adopting oxy-combustion carbon capture was modeled and the effect of replacing the conventional air separation unit (ASU) with the ion transport membrane (ITM) on the net system efficiency was analyzed. The ITM-based system was predicted to consume less net auxiliary power owing to an additional nitrogen expander. Even with a regular pressure ratio which is 21, the ITM-based system would provide a higher net efficiency than the optimized ASU-based system which should be designed with a very high pressure ratio around 90. The optimal net efficiency of the ITM-based system is more than 3% higher than that of the ASU-based system. The influence of the operating pressure and temperature of the ITM on system efficiency was predicted to be marginal.

Automated scrap-sorting research using a line-scan camera system (라인스캔 카메라 시스템을 이용(利用)한 스크랩 자동선별(自動選別) 연구(硏究))

  • Kim, Chan-Wook;Kim, Hang-Goo
    • Resources Recycling
    • /
    • v.17 no.6
    • /
    • pp.43-49
    • /
    • 2008
  • In this study, a scrap sorting system using a color recognition method has been developed to automatically sort out specified materials from a mixture, and its application as been examined in the separation of Cu and other non-ferrous metal parts from a mixture of iron scraps. The system is composed of three parts; measuring, conveying and ejecting parts. The color of scrap surface is recognized by the measuring part consisting of a line-scan camera, light sources and a frame grabber. The recognition is program-controlled by a image processing algorithms, and thus only the scrap part of designated color is separated by the use of air nozzles. In addition, the light system is designed to meet a high speed of sorting process with a frequency-variable inverter and the air nozzled ejectors are to be operated by an I/O interface communication with a hardware controller. In the functional tests of the system, its efficiency in the recognition of Cu scraps from its mixture with Fe ones reaches to more than 90%, and that in the separation more than 80% at a conveying speed of 25 m/min. Therefore, it is expected that the system can be commercialized in the industry of shredder makers if a high efficiency ejecting system is realized.

A High Efficiency Multi Output PDP Power System with Single Transformer Structure (Multi 출력단을 Single Transformer로 통합 설계한 고효율 PDP용 전원시스템)

  • Park, Sang-Gab;Kim, Jong-Hae;Lee, Hyo-Bum;Han, Sang-Kyu;Hong, Sung-Soo;SaKong, Sug-Chin;Roh, Chung-Wook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.70-77
    • /
    • 2008
  • Conventional PDP power system, which commonly uses two isolation transformer, consists of sustaining power ($V_S$), addressing power($V_A$), and Multi power($V_M$). Because each of these power conversion circuits use transformer and control IC, there are several defects: decrease of efficiency, rise of cost, and parts stress. This paper is proposed the method which operates PDP power system only with one transformer. The proposed method contributes not only to high-efficient performance of the DC/DC power stage and improvement of reliability but also to reduction of cost by reducing volume and size. Also, proposed method is proper to Address Display-period Separation(ADS) which is one of the driving methods of PDP. Superiority of the proposed method is proved by comparison with conventional method and theoretical, experimental analysis.

Fabrication of EEG Measuring System with High Precision Characteristics (고정밀도의 뇌파측정시스템 개발 연구)

  • 도영수;장호경;한병국
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.156-162
    • /
    • 2002
  • In this study, we attempted in preparing high precision EEG measuring equipment. To measure EEG in high efficiency, pre-amplifier should get high performance common mode rejection ratio. Also, separation amplifier is essential to eliminate common line noise. So, our study were pointed at elevating the efficiency of eliminating noise, user safety and low noise characteristics. Prepared high precision pre-amplifier for EEG was A/D converted to automatically classify $\alpha$ wave, $\beta$ wave and $\theta$ wave. And converted data were Fast Fourier Transformed with real time DSP (Digital Signal Processing). Clinical demonstrations were carried out with healthy students, aged between 20 to 26 who has no histories of illness. To recognize the efficiency of the EEG, prepared EEG were used with MS equipment in low stimulated state and high stimulated state. Then, we studied at the effect of sensitivity on brain wave. From this study, it is known that our EEG equipment is efficient in sensitivity evaluation and suitable stimulations for each psychological state are required.

  • PDF

How to Eliminate CO, CO2 and CH4 in H2 & Inert Gas -Possibility of Fuel Cell Application- (수소와 불활성 가스 중 일산화탄소, 이산화탄소, 메탄 제거에 관한 연구 -연료전지에의 적용 가능성-)

  • Lee, Taek-Hong;Cheon, Young-Ki
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.15 no.3
    • /
    • pp.220-227
    • /
    • 2004
  • The purpose of this paper is, based on the theoretical background of the principle of gas purification and absorption, and the absorbing ability of metals, to syudy the efficiency of gas purification of inorganic gases using Zr alloys, so as to contribute to the IT industry. To produce and distribute gas with high purity and ultra-high purity, different types of gas purifier are currently being used: distillation type, getter type, catalyst type, absorption at low-temperature type, and membrane separation equipment. From the different purification methods mentioned above, the getter type gas purifier is capable of not only high performance and capacity but also P.O.U(Point Of Use) method. The key of the getter type gas purifier is its efficiency of gas purification, which is the subject chosen for this study.

Platinum Decoration of a 3D Oxidized Graphitic Carbon Nitride/Graphene Aerogel for Enhanced Visible-Light Photocatalytic Hydrogen Evolution

  • Thi Kieu Oanh Nguyen;Thanh Truong Dang;Tahereh Mahvelati-Shamsabadi;Jin Suk Chung
    • Korean Chemical Engineering Research
    • /
    • v.61 no.4
    • /
    • pp.627-634
    • /
    • 2023
  • Graphitic carbon nitride (g-C3N4) has attracted considerable attention since its discovery for its catalysis of water splitting to hydrogen and oxygen under visible light irradiation. However, pristine g-C3N4 confers only low photocatalytic efficiency and requires surface cocatalysts to reach moderate activity due to a lack of accessible surface active sites. Inspired by the high specific surface area and superior electron transfer of graphene, we developed a strongly coupled binary structure of graphene and g-C3N4 aerogel with 3D porous skeleton. The as-prepared 3D structure photocatalysts achieve a high surface area that favors efficient photogenerated charge separation and transfer, enhances the light-harvesting efficiency, and significantly improves the photocatalytic hydrogen evolution rate as well. The photocatalyst performance is observed to be optimized at the ratio 3:7 (g-C3N4:GO), leading to photocatalytic H2 evolution of 16125.1 mmol. g-1. h-1 under visible light irradiation, more than 161 times higher than the rate achieved by bulk g-C3N4.

Development of an Automated Diffusion Scrubber-Conductometry System for Measuring Atmospheric Ammonia

  • Lee, Bo-Kyoung;Lee, Chong-Keun;Lee, Dong-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.6
    • /
    • pp.2039-2044
    • /
    • 2011
  • A semi-continuous and automated method for quantifying atmospheric ammonia at the parts per billion level has been developed. The instrument consists of a high efficiency diffusion scrubber, an electrolytic on-line anion exchange device, and a conductivity detector. Water soluble gases in sampled air diffuse through the porous membrane and are absorbed in an absorbing solution. Interferences are eliminated by using an anion exchange devises. The electrical conductivity of the solution is measured without chromatographic separation. The collection efficiency was over 99%. Over the 0-200 ppbv concentration range, the calibration was linear with $r^2$ = 0.99. The lower limit of detection was 0.09 ppbv. A parallel analysis of Seoul air over several days using this method and a diffusion scrubber coupled to an ion chromatography system showed acceptable agreement, $r^2$ = 0.940 (n = 686). This method can be applied for ambient air monitoring of ammonia.