The Usefulness of Q.Clear Technique in PET / CT (PET/CT 검사에서 Q.Clear 기법의 유용성에 대한 고찰)

  • Choi, Yong Hoon;Kim, Jung Yul;Choi, Young Sook;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.31-36
    • /
    • 2017
  • Purpose Recently, the performance of PET/CT scanner has been improved and various techniques have been developed to increase the image quality such as Sensitivity and Resolution. The purpose of this study is to evaluate the usefulness of Q.Clear (a fully convergent iterative reconstruction) technique of GE Discovery IQ equipment to enhance the image quality. Materials and Methods All scans were acquired by Discovery IQ (GE Healthcare, MI, USA). In NEMA IEC Body Phantom test, Background to Hot-sphere (10 mm, 13 mm, 17 mm, 22 mm) ratio was 1:4 and scan time was 3 minutes. The images were reconstructed by VPHDs (VUE Point High-Definition + SharpIR) and Q.Clear to evaluate each Contrast. We injected 18F-FDG 187 M㏃ to PET/SPECT Performance Phantom. And then it was scanned for 4 minutes to evaluate Resolution and Uniformity. T-test statistical analysis was performed on SUVmax of small lesions less than 2 cm in 100 clinical patients regardless of disease type. Results In the NEMA IEC Body Phantom, the Contrast was $63.6{\pm}5.7%$ (VPHDs) and $75{\pm}4.8%$ (Q.Clear). In the PET/SPECT Performance Phantom, the Resolution was 9.2 mm (VPHDs) and 7.3 mm (Q.Clear). Uniformity of Q.Clear was 10.8% better than VPHDs. T-test statistic of the clinical patients showed a significant difference of p value of 0.021. Conclusion Both the phantom test and the clinical results showed that the quality of the image was improved in Q.Clear was applied. The SUVmax was highly measured in Q.Clear and the lesions were clearly distinguished visually. Therefore Q.Clear can be useful in various aspects such as dose-reduction, patients evaluation and image analysis.

  • PDF

The Clinical Value of Intima-media Thickness in Patients with Stable Coronary Artery Disease and C-reactive Protein within Normal Limits (경동맥 내중막 두께가 정상 C-반응성 단백질 농도를 가진 안정형 협심증 환자에서 가지는 임상적 의의)

  • Kwon, Jong-Bum;Park, Kuhn;Choi, Si-Young;Park, Chan-Beom;Kim, Yong-Hwan;Her, Sung-Ho;Park, Mahn-Won;Lee, Jong-Ho
    • Journal of Chest Surgery
    • /
    • v.43 no.5
    • /
    • pp.482-489
    • /
    • 2010
  • Background: The purpose of this study was to determine whether hand-measured carotid intima-media thickness (IMT) was a reliable and simple tool that could be used to evaluate the severity of stable coronary artery disease (CAD) with normal high-sensitivity C-reactive protein (CRP). Material and Method: We examined left carotid IMTs in 688 patients with stable CAD and excluded 121 patients with abnormally elevated hs-CRP ($\geq$0.5 mg/dL). We sought to determine the association between risk factors and the severity of stable CAD and carotid IMT in 567 patients who were divided into lower and higher groups based on the median value. Patients underwent a coronary artery angiogram and had at least significant stenosis (>50% of the original luminal diameter involving one or more major coronary artery). Result: Of the 567 patients, 300 (52.9%) were in the lower IMT group and 267 (47.1%) were in the higher IMT group; the median value was 0.76 mm. By multivariable logistic regression analysis, the following groups were different: older age (~49 vs. 70~ years, respectively; OR=6.552), high FBS (~99 vs. 120~ mg/dL; OR=1.713) and severity of CAD (1 vessel vs. 2 vessel disease; OR=1.711, 1 vessel vs. 3 vessel disease; OR=1.714). Conclusion: We conclude that there are correlations between increased carotid IMT and severity of CAD in stable angina patients with normal CRP levels.

Victims of Bullying among Korean Adolescents: Prevalence and Association with Psychopathology Evaluated Using the Adolescent Mental Health and Problem Behavior Screening Questionnaire-II Standardization Study Data (청소년정서행동발달검사 표준화연구 자료를 활용한 학교폭력 피해 전국유병률 및 관련요인 조사)

  • Bhang, Soo-Young;Yoo, Han-Ik K.;Kim, Ji-Hoon;Kim, Bong-Seog;Lee, Young-Sik;Ahn, Dong-Hyun;Suh, Dong-Su;Cho, Soo-Churl;Hwang, Jun-Won;Bahn, Geon-Ho
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.23 no.1
    • /
    • pp.23-30
    • /
    • 2012
  • Objectives : This study was conducted to investigate the prevalence of victims of bullying and the demographic characteristics of victims, and their related psychopathology, in a Korean nationwide sample of youths in middle and high school over a one month period. Methods : During the autumn of 2009, students in the 7th to 12th grades at 23 secondary schools participated in a nationwide, cross-sectional study. The study subjects completed the Adolescent Mental Health and Problem Behavior Screening Questionnaire-II (AMPQ-II) and Symptom Checklist-90-Revision (SCL-90-R). Based on the data acquired, descriptive statistics, correlation coefficients and multiple logistic regression analysis were performed. Results : Among the 3364 participants, 2272 (67.54%) completed the questionnaire. The prevalence of victimization was 28.9%. Male gender was positively associated with victimization, and grade level was negatively related to victimization. The AMPQ-II bullying score (Factor 4) was significantly (p<.001) and positively correlated to the AMPQ-II student total score (r= 0.50), Worry and thought (Factor 1 ; r=0.38), Mood and suicide (Factor 2 ; r=0.31), Academic and Internet-related problems (Factor 3 ; r=0.24), Rule violations (Factor 5 ; r=0.23), and AMPQ-II teacher total score (r=0.11). Somatization (r=0.23), Obsessive-compulsive behavior (r=0.24), Interpersonal sensitivity (r=0.30), Depression (r=0.33), Anxiety (r=0.26), Hostility (r=0.30), Phobic anxiety (r=0.22), Paranoid ideation (r=0.36), and Psychoticism (r=0.31) results from the SCL-90-R were also found to be positively related to the AMPQ-II bullying score, and remained significant after adjusting for age and gender. A total of 26% of the victims reported suicidal ideations as compared to 9% of non-victims over the month prior to the evaluation ($x^2$=119.595, df=1, p<.001). The multiple logistic regression analysis indicated that the AMPQ-II bullying score significantly increased the risk of suicidal ideation [Exp(b)=1.55, df=1, p<.001] after adjusting for age and gender. Conclusion : School bullying was highly prevalent among Korean middle and high school students. This study provided strong evidence that suicidal ideation and psychopathology were serious problems among the victims of bullying.

The Usefulness of LEUR Collimator for 1-Day Basal/Acetazolamide Brain Perfusion SPECT (1-Day Protocol을 사용하는 Brain Perfusion SPECT에서 LEUR 콜리메이터의 유용성)

  • Choi, Jin-Wook;Kim, Soo-Mee;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.94-100
    • /
    • 2011
  • Purpose: Basal/Acetazolamide-challenged brain perfusion SPECT is very useful to assess cerebral perfusion and vascular reserve. However, as there is a trade off between sensitivity and spatial resolution in the selection of collimator, the selection of optimal collimator is crucial. In this study, we examined three collimators to select optimal one for 1-day brain perfusion SPECT. Materials and Methods: Three collimators, low energy high resolution-parallel beam (LEHR-par), ultra resolution-fan beam (LEUR-fan) and super fine-fan beam (LESFR-fan), were tested for 1-day imaging using Triad XLT 9 (TRIONIX). The SPECT images of Hoffman 3D brain phantom filled with 99mTc of 170 MBq and a normal volunteer were acquired with a protocol of 50 kcts/frame and detector rotation of 3 degree. Filterd backprojection (FBP) reconstruction with Butterworth filter (cut off frequencies, 0.3 to 0.5) was performed. The quantitative and qualitative assessments for three collimators were performed. Results: The blind tests showed that LESFR-fan provided the best image quality for Hoffman brain phantom and the volunteer. However, images for all the collimator were evaluated as 'acceptable'. On the other hand, in order to meet the equivalent signal-to-noise ratio (SNR), total acquisition time or radioactivity dose for LESFR-fan must have been increased up to almost twice of that for LEUR-fan and LEHR-par. The volunteer test indicated that total acquisition time could be reduced approximately by 10 to 14 min in clinical practice using LEUR-fan and LEHR-par without significant loss on image quality, in comparison with LESFR-fan. Conclusion: Although LESFR-fan provides the best image quality, it requires significantly more acquisition time than LEUR-fan and LEHR-par to provide reasonable SNR. Since there is no significant clinical difference between three collimators, LEUR-fan and LEHR-par can be recommended as optimal collimators for 1-day brain perfusion imaging with respect to image quality and SNR.

  • PDF

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

Comparison of Collimator Choice on Image Quality of I-131 in SPECT/CT (I-131 SPECT/CT 검사의 에서 조준기 종류에 따른 영상 비교 평가)

  • Kim, Jung Yul;Kim, Joo Yeon;Nam-Koong, Hyuk;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.33-42
    • /
    • 2014
  • Purpose: I-131 scan using High Energy (HE) collimator is generally used. While, Medium Energy (ME) collimator is not suggested to use in result of an excessive septal penetration effects, it is used to improve the sensitivities of count rate on lower dose of I-131. This research aims to evaluate I-131 SPECT/CT image quality using by HE and ME collimator and also find out the possibility of ME collimator clinical application. Materials and Methods: ME and HE collimator are substituted as Siemens symbia T16 SPECT/CT, using I-131 point source and NEMA NU-2 IQ phantom. Single Energy Window (SEW) and Triple Energy Windows (TEW) are applied for image acquisition and images with CTAC and Scatter correction application or not, applied different number of iteration and sub set are reconstructed by IR method, flash 3D. By analysis of acquired image, the comparison on sensitivities, contrast, noise and aspect ratio of two collimators are able to be evaluated. Results: ME Collimator is ahead of HE collimator in terms of sensitivity (ME collimator: 188.18 cps/MBq, HE collimator: 46.31 cps/MBq). For contrast, reconstruction image used by HE collimator with TEW, 16 subset 8 iteration applied CTAC is shown the highest contrast (TCQI=190.64). In same condition, ME collimator has lower contrast than HE collimator (TCQI=66.05). The lowest aspect ratio for ME collimator and HE collimator are 1.065 with SEW, CTAC (+) and 1.024 with TEW, CTAC (+) respectively. Conclusion: Selecting a proper collimator is important factor for image quality. This research finding tells that HE collimator, which is generally used for I-131 scan emitted high energy ${\gamma}$-ray is the most recommendable collimator for image quality. However, ME collimator is also applicable in condition of lower dose, lower sensitive if utilizing energy window, matrix size, IR parameter, CTAC and scatter correction appropriately.

  • PDF

Japanese Medaka, Oryzias latipes as a Test Animal for Marine Ecotoxicological Evaluation (해양생태독성평가를 위한 표준시험생물로서의 송사리(Oryzias latipes)에 관한 연구)

  • Park Gyung Soo;Yoon Seong Jin;Lee Seung Min;Kim Ae Hyang;Park Soung Yun;Kang Duk Young
    • Korean Journal of Environmental Biology
    • /
    • v.23 no.3 s.59
    • /
    • pp.293-303
    • /
    • 2005
  • Japanese medaka, Oryzias latipes is widely distributed in the North East Asia including Korea, Japan and east China, and commonly used for freshwater toxicity tests and cytotoxicological studies worldwide. In this study, a series of experiments were conducted to identify the potential of the fish as a standard test species for saltwater toxicity evaluation such as marine receiving waters, ocean-dumped materials and sediment pore waters etc. Hatching, growth and mortality rates of the fish were estimated with the wide ranges of salinity from freshwater to seawater (35 psu). Direct exposure of the fertilized eggs in freshwater to the wide ranges of salinity (from 0 to 35 psu) without pre- acclimation to the saltwater revealed no significant differences in hatching rates by salinities (p =0.24). On the other hand, medaka larvae hatched in freshwater and exposed to saltwater directly showed high mortality at > 25 psu treatment groups (p < 0.0001). However, there was no significant difference in mortality of medaka larvae hatched in 13.8 and 14.2 psu at the wide ranges of salinities ($0\~35$ psu). Growth rates of medaka larvae hatched in the above two salinities showed no differences in body length either from 0 to 35 psu treatment groups (p =0.64 for 13.8 psu group and p=0.32 for 14.2 psu group). The number of gill chloride cell in medaka larvae sharply increased when the larvae were exposed to high salinity. Reference tests with zinc chloride revealed 96h $LC_{50}=8.84(7.19\~10.87)mg\;L^{-1}$ using 7~10 day old medaka larvae. These were comparable or better sensitivity in comparison with the other standard test species such as North American sheepshead minnow Cyprinodon variegatus. Based on the results of these experiments, hatching rates and larvalmortality of medaka must be good toxicity parameters for seawater bioassay and the species seems to be a good standard species for both the freshwater and seawater toxicity test.

Estimation of Reliability of Real-time Control Parameters for Animal Wastewater Treatment Process and Establishment of an Index for Supplemental Carbon Source Addition (가축분뇨처리공정의 자동제어 인자 신뢰성 평가 및 적정 외부탄소원 공급량 지표 확립)

  • Pak, JaeIn;Ra, Jae In-
    • Journal of Animal Science and Technology
    • /
    • v.50 no.4
    • /
    • pp.561-572
    • /
    • 2008
  • Responses of real-time control parameters, such as ORP, DO and pH, to the conditions of biological animal wastewater treatment process were examined to evaluate the stability of real-time control using each parameter. Also an optimum index for supplemental carbon source addition based on NOx-N level was determined under a consideration of denitrification rate by endogenous respiration of microorganism and residual organic matter in liquor. Experiment was performed with lab-scale sequencing batch reactor(SBR) and working volume of the process was 45L. The distinctive nitrogen break point(NBP) on ORP-and DO-time profiles, which mean the termination of nitrification, started disappearing with the maintenance of low NH4-N loading rate. Also the NBP on ORP-and DO-time profiles was no longer observed when high NOx-N was loaded into the reactor, and the sensitivity of ORP became dull with the increase of NOx-N level. However, the distinctive NBP was constantly occurred on pH(mV)-time profile, maintaining unique profile patterns. This stable occurrence of NBP on pH(mV)-time profile was lasted even at very high NOx-N:NH4-N ratio(over 80:1) in reactor, and the specific point could be easily detected by tracking moving slope change(MSC) of the curve. Revelation of NBP on pH(mV)-time profile and recognition of the realtime control point using MSC were stable at a condition of over 300mg/L NOx-N level in reactor. The occurrence of distinctive NBP was persistent on pH(mV)-time profile even at a level of 10,000mg/L STOC(soluble total organic carbon) and the recognition of NBP was feasible by tracing MSC, but that point on ORP and DO-time profiles began to disappear with the increase of STOC level in reactor. The denitrfication rate by endogenous respiration and residual organic matter was about 0.4mg/L.hr., and it was found that 0.83 would be accepted as an index for supplemental carbon source addition when 0.1 of safety factor was applied.

Effects of Arginine Vasopressin(AVP) Infusion on the Patients with Catecholamine-dependent Septic Shock (카테콜아민계 승압제를 투여중인 패혈성 쇼크 환자에서 아르기닌 바소프레신(AVP)의 효과)

  • Sheen, Seung Soo;Lim, Seung Guan;Jo, Sook Kyoung;Song, Kyoung Eun;Lee, Hyoung No;Oh, Yoon Jung;Park, Kwang Joo;Hwang, Sung Chul
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.5
    • /
    • pp.506-515
    • /
    • 2003
  • Background : A decreased level of serum arginine vasopressin(AVP) and an increased sensitivity to an exogenous AVP is expected in patients with septic shock who often require a high infusion rate of catecholamines. The goal of the study was to determine whether an exogenous AVP infusion to the patients with septic shock would achieve a significant decrement in infusion rate of catecholamine vasopressors while maintaining hemodynamic stability and adequate urine output. Method : Eight patients with septic shock who require a high infusion rate of norepinephrine had received a trial of 4-hour AVP infusion with simultaneous titration of norepinephrine. Hemodynamic parameters and urine output were monitored during the AVP infusion and the monitoring continued up to 4 hours after the AVP infusion had stopped. Results : Mean arterial pressure showed no significant changes during the study period(p=0.197). Norepinephrine infusion rate significantly decreased with concurrent AVP administration(p=0.001). However, beneficial effects had disappeared after the AVP infusion was stopped. In addition, hourly urine output showed no significant changes throughout the trials(p=0.093). Conclusion : Concurrent AVP infusion achieved the catecholamine vasopressor sparing effect in the septic shock patients, but there was no evidence of the improvement of renal function. Further study may be indicated to determine whether AVP infusion would provide an organ-protective effect to the septic shock patients.

Performance Estimation of Large-scale High-sensitive Compton Camera for Pyroprocessing Facility Monitoring (파이로 공정 모니터링용 대면적 고효율 콤프턴 카메라 성능 예측)

  • Kim, Young-Su;Park, Jin Hyung;Cho, Hwa Youn;Kim, Jae Hyeon;Kwon, Heungrok;Seo, Hee;Park, Se-Hwan;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • Compton cameras overcome several limitations of conventional mechanical collimation based gamma imaging devices, such as pin-hole imaging devices, due to its electronic collimation based on coincidence logic. Especially large-scale Compton camera has wide field of view and high imaging sensitivity. Those merits suggest that a large-scale Compton camera might be applicable to monitoring nuclear materials in large facilities without necessity of portability. To that end, our research group have made an effort to design a large-scale Compton camera for safeguard application. Energy resolution or position resolution of large-area detectors vary with configuration style of the detectors. Those performances directly affect the image quality of the large-scale Compton camera. In the present study, a series of Geant4 Monte Carlo simulations were performed in order to examine the effect of those detector parameters. Performance of the designed large-scale Compton camera was also estimated for various monitoring condition with realistic modeling. The conclusion of the present study indicates that the energy resolution of the component detector is the limiting factor of imaging resolution rather than the position resolution. Also, the designed large-scale Compton camera provides the 16.3 cm image resolution in full width at half maximum (angular resolution: $9.26^{\circ}$) for the depleted uranium source considered in this study located at the 1 m from the system when the component detectors have 10% energy resolution and 7 mm position resolution.