• 제목/요약/키워드: High resolution imaging

검색결과 904건 처리시간 0.03초

Review of Recent Advancement of Ultra High Field Magnetic Resonance Imaging: from Anatomy to Tractography

  • Cho, Zang-Hee
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권3호
    • /
    • pp.141-151
    • /
    • 2016
  • Purpose: Advances of magnetic resonance imaging (MRI), especially that of the Ultra-High Field (UHF) MRI will be reviewed. Materials and Methods: Diffusion MRI data was obtained from a healthy adult young male of age 30 using a 7.0T research MRI scanner (Magnetom, Siemens) with 40 mT/m maximum gradient field. The specific imaging parameters used for the data acquisition were a single shot DW echo planar imaging. Results: Three areas of the imaging experiments are focused on for the study, namely the anatomy, angiography, and tractography. Conclusion: It is envisioned that, in near future, there will be more 7.0T MRIs for brain research and explosive clinical application research will also be developed, for example in the area of connectomics in neuroscience and clinical neurology and neurosurgery.

Evaluation of Hydration Effect on Human Skin by $^1H$ MRS at 14.1T

  • Choi Chi-Bong;Hong Sung-Tak;Choe Bo-Young;Woo Dong-Chul;Yoon Seong-Ik;Cho Ji-Hyun;Lee Chul-Hyun;Cheong Chae-Joon;Park Sang-Yong;Oh Chil-Hwan
    • 한국자기공명학회논문지
    • /
    • 제10권1호
    • /
    • pp.105-114
    • /
    • 2006
  • Purpose: We achieved high resolution MR imaging and spectra of human skin in vitro with using a 14.1 T MRI/MRS system, and evaluated the hydration effect of various cosmetic products by measuring the skin's. moisture concentration. Materials and Methods: We used the Bruker 14.1 T MRI/MRS system with a vertical standard bore that was equipped with a DMX spectrometer gradient system (200 G/cm at a maximum 40 A), RF resonators (2, 5 and 10 mm) and Para Vision software. Spin echo and fast spin echo pulse sequences were employed for obtaining the high resolution MR images. The 3D-localized point resolved spectroscopy (PRESS) method was used to acquire the MR spectra. Results: The high resolution MR images and spectra of human skin in vitro were successfully obtained on a 14.1 T system. The water concentration of human skin after applying a moisturizer was higher than that before applying a moisturizer. Conclusions: The present study demonstrated that the high-resolution MR images and spectra of human skin from a high field NMR instrument could be applicable to evaluating the hydration state of the stratum corneum.

  • PDF

영상융합 기반 고해상도 영상복원 (High-resolution image restoration based on image fusion)

  • 신정호;이정수;백준기
    • 방송공학회논문지
    • /
    • 제10권2호
    • /
    • pp.238-246
    • /
    • 2005
  • 본 논문에서는 공간 적응적 제약조건과 정칙화 함수를 이용한 반복적 고해상도 영상보간 기법을 제안한다. 제안된 정칙화 영상보간 알고리듬은 에지 방향에 따라 제약조건들을 적응적으로 적용하고, 각각의 반복 연산 단계에서 에지 방향별 정칙화에 적합한 정칙화 함수를 최적화하여 고해상도 영상보간을 구현한다. 제안한 알고리즘은 기존의 비적응적 정칙화 보간 방법뿐만 아니라 적응적 보간 방법보다도 방향성 고주파 성분을 적절히 보존하는 동시에 잡음과 같은 바람직하지 못한 효과들을 억제할 수 있다. 마지막으로 본 논문에서 제안한 알고리듬의 성능평가를 위해서 기존에 제안된 여러 가지의 고해상도 영상보간 알고리듬과의 다양한 비교실험을 수행하였고, 이를 통하여 제안한 고해상도 영상보간 기법이 주관적으로나 객관적으로 우수함을 보였다.

Diagnostic Usefulness of High Resolution Cross Sectional MRI in Symptomatic Middle Cerabral Arterial Dissection

  • Lee, Hai-Ong;Kwak, Hyo-Sung;Chung, Gyung-Ho;Hwang, Seung-Bae
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권6호
    • /
    • pp.370-372
    • /
    • 2011
  • Dissection of the middle cerebral artery (MCA) is less frequent compared with dissection of the vertebrobasilar system or carotid artery. Recently, high-resolution cross sectional MR imaging (HRMRI) has emerged as a potential technique for atherosclerotic plaque imaging in MCA, We introduce the findings of HRMRI in a 56-year-old woman with traumatic MCA dissection, HRMRI showed an intimal flap and tapered pseudolumen with intra-luminal hemorrhage, We performed stent deployment about MCA dissection after failed medical treatment Three months later, there was no in-stent restenosis and no further neurological deficit were noted.

Sub-surface imaging and vector precision from high resolution down-hole TEM logging

  • Chull, James;Massie, Duncan
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2005년도 제7회 특별심포지움 논문집
    • /
    • pp.11-18
    • /
    • 2005
  • Filament inversion routines are highly effective for target definition whenever total-field DHTEM vectors can be obtained using three-component logging tools. However most cross-hole components contain significant noise related to sensor design and errors in observation of probe rotation. Standard stacking methods can be used to improve data quality but additional statistical methods based on cross-correlation and spatial averaging of orthogonal components may be required to ensure a consistent vector migration path. Apart from assisting with spatial averaging, multiple filaments generated for successive time-windows can provide additional imaging information relating to target geometry and current migration. New digital receiver systems provide additional time-windows to provide better tracking options necessary for high-resolution imaging of this type.

  • PDF

Plasmonic Color Filter with Robustness Against Cross Talk for Compact Imaging Applications

  • Cho, Hyo Jong;Do, Yun Seon
    • Current Optics and Photonics
    • /
    • 제4권1호
    • /
    • pp.16-22
    • /
    • 2020
  • In high resolution imaging devices, smaller aperture in the color filter causes cross talk which provides incorrect information. Plasmonic color filters (PCFs) have been reported as an alternative of the conventional color resist based-color filter (CRCF) and many studies on PCFs demonstrated the filtering function by PCFs with a sub-micron size. In this work, we investigated the cross talk performance of PCFs compared to CRCFs. The effect of cross talk over distance from the filter were measured for each filter. Despite poorer spectral filtering characteristics, PCFs were more robust against cross talk than CRCFs. Also, the further away from the filter, the more cross talk appeared. As a result, PCFs showed less cross talk than CRCFs at about 82% of the results measured at a distance of 2~10 ㎛. This study will help to make practical use of PCFs in high-resolution imaging applications.

Cone beam형 전산화단층영상의 원리 (Basic principle of cone beam computed tomography)

  • 최용석;김규태;황의환
    • Imaging Science in Dentistry
    • /
    • 제36권3호
    • /
    • pp.123-129
    • /
    • 2006
  • The use of computed tomography for dental procedures has increased recently. Cone beam computed tomography (CBCT) systems have been designed for imaging hard tissues of the dentomaxillofacial region. CBCT is capable of providing high resolution in images of high diagnostic quality. This technology allows for 3-dimensional representation of the dentomaxillofacial skeleton with minimal distortion, but at lower equipment cost, simpler image acquisition and lower patient dose. Because this technology produces images with isotropic sub-millimeter spatial resolution, it is ideally suited for dedicated dentomaxillofacial imaging. In this paper, we provide a brief overview of cone beam scanning technology and compare it with the fan beam scanning used in conventional CT and the basic principles of currently available CBCT systems.

  • PDF

Biological Applications of Helium Ion Microscopy

  • Kim, Ki Woo
    • Applied Microscopy
    • /
    • 제43권1호
    • /
    • pp.9-13
    • /
    • 2013
  • The helium ion microscope (HIM) has recently emerged as a novel tool for imaging and analysis. Based on a bright ion source and small probe, the HIM offers advantages over the conventional field emission scanning electron microscope. The key features of the HIM include (1) high resolution (ca. 0.25 nm), (2) great surface sensitivity, (3) great contrast, (4) large depth-of-field, (5) efficient charge control, (6) reduced specimen damage, and (7) nanomachining capability. Due to the charge neutralization by flood electron beam, there is no need for conductive metal coating for the observation of insulating biological specimens by HIM. There is growing evidence that the HIM has substantial potential for high-resolution imaging of uncoated insulating biological specimens at the nanoscale.

고주파수 초음파 영상을 위한 저잡음·광대역 수신 시스템 구현 (Implementation of low-noise, wideband ultrasound receiver for high-frequency ultrasound imaging)

  • 문주영;이준수;장진호
    • 한국음향학회지
    • /
    • 제36권4호
    • /
    • pp.238-246
    • /
    • 2017
  • 고주파수, 고해상도 초음파 영상을 획득하기 위해서는 고주파수 초음파 변환기가 가지는 작은 구경에 따른 낮은 민감도와 침투 깊이에 따른 높은 감쇠량을 극복하여야 한다. 이는 고주파수 초음파 변환기의 본질적인 한계점이므로 수신 시스템을 통하여 그 한계점을 극복하여야 한다. 본 논문은 고주파수, 고해상도 초음파 영상을 위하여 고주파수 초음파 변환기의 본질적인 한계인 낮은 민감도와 높은 감쇠량을 극복할 수 있는 저잡음 광대역 수신 시스템 개발과 특성 평가 결과에 관한 것이다. 개발한 저잡음 광대역 수신 시스템은 80 MHz 이상의 동작 주파수 대역에서 최대 73 dB의 증폭 이득과 48 dB의 가변 이득 범위를 만족하며 ${\pm}1dB$의 증폭 이득 평탄도 성능을 가진다. 또한 개발한 수신 시스템은 상용 리시버에 비하여 8.4 dB 이상의 신호대잡음비 성능과 3.7 dB 이상의 대조도 성능이 우수함을 확인하였다.

Spaceborne High Speed Data Link Design for Multi-Mode SAR Image Data Transmission

  • Kwag, Young-Kil
    • Journal of electromagnetic engineering and science
    • /
    • 제2권1호
    • /
    • pp.39-44
    • /
    • 2002
  • A high speed data link capability is one of the critical factors in determining the performance of the spaceborne SAR system with high resolution because of the strict requirement far the real-time data transmission of the massive SAR data in a limited time of mission. In this paper, based on the data lint model characterized by the spaceborne small SAR system, the high rate multi-channel data link module is designed including link storage, link processor, transmitter, and wide-angle antenna. The design results are presented with the performance analysis on the data link budget as well as the multi-mode data rate in association with the SAR imaging mode of operation from high resolution to the wide swath.