• Title/Summary/Keyword: High resolution MRI

Search Result 129, Processing Time 0.028 seconds

MRI의 현황과 전망

  • 전희국
    • Journal of Biomedical Engineering Research
    • /
    • v.9 no.1
    • /
    • pp.125-130
    • /
    • 1988
  • In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of $0.1^{\circ}C$ under the spatial resolution of lmrad, the image matrix size of $256 {\times} 240, $ and tile imaging time of 4 seconds.

  • PDF

Acquisition and Interpretation Guidelines of Breast Diffusion-Weighted MRI (DW-MRI): Breast Imaging Study Group of Korean Society of Magnetic Resonance in Medicine Recommendations

  • Kang, Bong Joo;Kim, Min Jung;Shin, Hee Jung;Moon, Woo Kyung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.26 no.2
    • /
    • pp.83-95
    • /
    • 2022
  • The purpose of this study was to establish and provide guidelines for the standardized acquisition and interpretation of diffusion-weighted magnetic resonance imaging (DW-MRI) to improve the image quality and reduce the variability of the results interpretation. The standardized protocol includes the use of high-resolution DW-MRI with advanced techniques and post-processing. The aim of the protocol is to increase the effectiveness of the medical image information exchange involved in the construction, activation, and exchange of clinical information for healthcare use. An organized interpretation form could make DW-MRIs' interpretation easier and more familiar. Herein, the authors briefly review the basic principles, optimized image acquisition, standardized interpretation guidelines, false negative and false positive cases of DW-MRI, and provide a standard interpretation form and examples of various cases to help users become more familiar with the DW-MRI.

Assessment of the Hydration Effect on In Vitro Human Skin by $^1H$ MRS at 14.1T System (고자장 14.1 T MRI/MRS 시스템에서 양성자 자기공명분광법을 이용한 생체 외 인체피부 보습효과에 대한 연구)

  • Choi Chi-Bong;Hong Sung-Tak;Woo Dong-Chul;Yoon Seong-Ik;Yoon Moon-Hyun;Cho Ji-Hyun;Lee Chul-Hyun;Cheong Chae-Joon;Park Sang-Yong;Oh Chil-Hwan;Choe Bo-Young
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.83-88
    • /
    • 2006
  • Purpose: We Investigated to achieve high resolution magnetic resonance (MR) Imaging and spectra of human skin in vitro with using a 14.1 T MRI/MRS system, and to evaluate the hydration effect of a moisturizer by measuring the skin's water concentration. Materials and Methods: We used the Brukrer 14.1 T MRI/MRS system with a vertical standard bore that was equipped with a DMX spectrometer gradient system (200 G/cm at a maximum 40 A), RF resonators (2, 5 and 10 mm) and Para Vision software. Spin echo and fast spin echo pulse sequences were employed for obtaining the high resolution MR images. The 3D-localized point resolved spectroscopy (PRESS) method was used to acquire the MR spectra. Results: The high resolution MR images and spectra of human skin in vitro were successfully obtained on a 14.IT system. The water concentration of human skin after applying a moisturizer was higher than that before applying a moisturizer. Conclusions: The present study demonstrated that the high-resolution MR images and spectra of human skin from a high field MRS instrument could be applicable to evaluating the hydration state of the stratum corneum.

  • PDF

Electrical Impedance Tomography and Biomedical Applications

  • Woo, Eung-Je
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.1-6
    • /
    • 2007
  • Two impedance imaging systems of multi-frequency electrical impedance tomography (MFEIT) and magnetic resonance electrical impedance tomography (MREIT) are described. MFEIT utilizes boundary measurements of current-voltage data at multiple frequencies to reconstruct cross-sectional images of a complex conductivity distribution (${\sigma}+i{\omega}{\varepsilon}$) inside the human body. The inverse problem in MFEIT is ill-posed due to the nonlinearity and low sensitivity between the boundary measurement and the complex conductivity. In MFEIT, we therefore focus on time- and frequency-difference imaging with a low spatial resolution and high temporal resolution. Multi-frequency time- and frequency-difference images in the frequency range of 10 Hz to 500 kHz are presented. In MREIT, we use an MRI scanner to measure an internal distribution of induced magnetic flux density subject to an injection current. This internal information enables us to reconstruct cross-sectional images of an internal conductivity distribution with a high spatial resolution. Conductivity image of a postmortem canine brain is presented and it shows a clear contrast between gray and white matters. Clinical applications for imaging the brain, breast, thorax, abdomen, and others are briefly discussed.

  • PDF

Numerical Study on the Sub-Voxel Tracking Using Micro-Beads in a 3.0 T MRI (3.0 T MRI 환경에서 마이크로비드를 이용한 서브복셀 추적에 관한 수치해석적 연구)

  • Han, Byung-Hee;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.102-107
    • /
    • 2007
  • In molecular imaging studies via magnetic resonance imaging, in vivo cell tracking is an important issue for the observation of cell therapy or disease behavior. High resolution imaging and longitudinal study are necessary to track the cell movement. Since the field inhomogeneity extends over several voxels, we have performed the numerical analysis using the sub-voxel method dividing a voxel of MR image into several elements and the information about the field inhomogeneity distribution around the micro-beads. We imbedded ferrite-composite micro-beads with the size of $20-150{\mu}m$ in the subject substituted for cells to induce local field distortion. In the phantom imaging with the isotropic voxel size of $200{\mu}m^3$, we could confirm the feasibility of sub-voxel tracking in a 3.0 T MRI.

A study on the implementation of Imaging System for Magnetic Resonance Imaging (자기공명전단을 위한 영상화 시스템 구현에 관한 연구)

  • Jin, S.O.;Won, J.I.;Park, Y.H.;Huh, Y.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.597-599
    • /
    • 1998
  • The clinical acceptance of magnetic resonance imaging(MRI) system has been more rapid than that of the other medical image diagnosis system(X-ray, CT, etc) with the advantage of nonhazardous nature, high resolution capability, potential for chemically specified imaging. MRI system is composed of super conducting magnet, gradient fields, rf transceiver, system controller and imaging software technology. In this paper, introducing the principle of magnetic resonance imaging, it proposes the implementation of PC-based MRI system.

  • PDF

SSFP Interferometry (SSFPI) Technique Applied to functional MRI - A Fast and Direct Measurement of Magnetic Susceptibility Effect (SSFPI 기법을 이용한 MR 뇌기능 영상 -고 속의 자화율 효과의 직접적인 측정)

  • 정준영
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.525-534
    • /
    • 1996
  • We have developed a fast steady state free precession interferometry (SSFPI) technique which is useful for the fMRl (functional Magnetic Resonance Imaging). As is known, SSFP sequence with a suitable adjustment of Vadient (readeut) allows us to measure precession angle 6 which in tw relates to the field inhomogeneity. Combining the two pulses (known as FID and Echo) in FADE (Fast Acquisition Double Echo) sequence, for example, one can obtain the interference term which is directly related to the precession angle It has been known that a fast high resolution magnetic field mapping is possible by use of the modified FADE sequence or SSFPI, and we have attempted to use the SSFPI technique for the susceptibility-induced fMRl. When the method is applied to the susceptibility effect based functional magnetic resonance imaging (fMRl), it was found that the direct susceptibility effect measurement was possible without perturbations such as the backgrounds and inflow effect. In this paper, simulation results and experimental results obtained with 2.0 Tesla MRI system are presented.

  • PDF

Large-scale Synthesis of Uniform-sized Nanoparticles for Multifunctional Medical Applications

  • Hyeon, Taeg-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.1-1
    • /
    • 2011
  • We developed a new generalized synthetic procedure, called as "heat-up process," to produce uniform-sized nanocrystals of many transition metals and oxides without a size selection process. We were able to synthesize uniform magnetite nanocrystals as much as 1 kilogram-scale from the thermolysis of Fe-oleate complex. Clever combination of different nanoscale materials will lead to the development of multifunctional nano-biomedical platforms for simultaneous targeted delivery, fast diagnosis, and efficient therapy. In this presentation, I would like to present some of our group's recent results on the designed fabrication of multifunctional nanostructured materials based on uniform-sized magnetite nanoparticles and their medical applications. Uniform ultrasmall iron oxide nanoparticles of <3 nm were synthesized by thermal decomposition of iron-oleate complex in the presence of oleyl alcohol. These ultrasmall iron oxide nanoparticles exhibited good T1 contrast effect. In in vivo T1 weighted blood pool magnetic resonance imaging (MRI), iron oxide nanoparticles showed longer circulation time than commercial gadolinium complex, enabling high resolution imaging. We used 80 nm-sized ferrimagnetic iron oxide nanocrystals for T2 MRI contrast agent for tracking transplanted pancreatic islet cells and single-cell MR imaging. We reported on the fabrication of monodisperse magnetite nanoparticles immobilized with uniform pore-sized mesoporous silica spheres for simultaneous MRI, fluorescence imaging, and drug delivery. We synthesized hollow magnetite nanocapsules and used them for both the MRI contrast agent and magnetic guided drug delivery vehicle.

  • PDF

The Evaluation of Image Quality using Time of Flight in Intracranial Magnetic Resonance Imaging : Comparison with 1.5 T and 3.0 T (뇌혈관 자기공명영상에서 Time-of-flight(TOF) 기법을 이용한 영상의 질 평가: 1.5 T 와 3.0 T 자기공명영상 비교)

  • Goo, Eunhoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.43-48
    • /
    • 2015
  • Intracrnial 3D TOF MR angiography was performed in 30 normal volunteers with both 1.5 and 3.0 T MRI system with high resolutions. Used Voxel sizes were $0.39{\times}0.39{\times}0.2$(1.5 T) and $0.19{\times}0.19{\times}0.35$(3.0 T), respectively. High image quality and depiction of small vessel branches were equality demonstrated with 1.5 T and 3.0 T HR TOF MRA(p<0.05). Intracranial high resolution TOF MRA with 1.5 T and 3.0 T provides high diagnostic information with having merits and demerits in depiction of vascular branches.

  • PDF

Statistical methods for modelling functional neuro-connectivity (뇌기능 연결성 모델링을 위한 통계적 방법)

  • Kim, Sung-Ho;Park, Chang-Hyun
    • The Korean Journal of Applied Statistics
    • /
    • v.29 no.6
    • /
    • pp.1129-1145
    • /
    • 2016
  • Functional neuro-connectivity is one of the main issues in brain science in the sense that it is closely related to neurodynamics in the brain. In the paper, we choose fMRI as a main form of response data to brain activity due to its high resolution. We review methods for analyzing functional neuro-connectivity assuming that measurements are made on physiological responses to neuron activation. This means that we deal with a state-space and measurement model, where the state-space model is assumed to represent neurodynamics. Analysis methods and their interpretation should vary subject to what was measured. We included analysis results of real fMRI data by applying a high-dimensional autoregressive model, which indicated that different neurodynamics were required for solving different types of geometric problems.