• 제목/요약/키워드: High pressure

검색결과 13,859건 처리시간 0.044초

해양플랜트용 고압.고차압 제어밸브의 구조 안전성 평가 (Safety Estimation of High Pressure Drop Control Valve for Offshore Structures)

  • 김재웅
    • 한국생산제조학회지
    • /
    • 제20권5호
    • /
    • pp.553-558
    • /
    • 2011
  • This study have goal with conceptual design for offshore structures of high pressure drop control valve for localization valve for development accomplished with flow analysis based on provision of ANSI B16.34, ANSI B16.10, ANSI B16.25. In order to localize the Offshore structures high pressure drop control valve. This study is numerical analysis for zambil offshore project of high pressure drop control valve. The solver which ANSYS workbench used for offshore structures analysis. The working fluids assumed the glycerin(C3H8O3). The structural analysis used ANSYS which is a commercial code. Stress analysis result of internal pressure in valve showed lower than yield strength. This is expect to need more detail design and verification for stem and disk structure. In this study a multi-disk of high pressure drop control valve is designed and manufactured. Then, the flow rate and high pressure dorp of fluids flowing in the high pressure drop control valve is CAE. So, this system can be easily substituted for the existing zambil offshore project system. Finally, safety estimation for trim design of high pressure drop control valve for offshore structures.

LGT를 이용한 고온, 고압용 동압 센서 개발 (Development of the high-temperature, high-pressure Dynamic pressure sensor with LGT)

  • 권혁제;이경일;김동수;김영덕;이영태
    • 반도체디스플레이기술학회지
    • /
    • 제11권2호
    • /
    • pp.17-21
    • /
    • 2012
  • This study developed a high-temperature, high-pressure dynamic pressure sensor using LGT(lanthanum gallium tantalate). The sensitivity of the fabricated dynamic pressure sensor was 2.1 mV/kPa and its nonlinearity was 2.5%FS. We confirmed that the high-temperature dynamic pressure sensor operated stably in high-temperature environment at $500^{\circ}C$. The developed dynamic pressure sensor using LGT is expected to be applicable not only to gas turbines but also in various industrial areas in duding airplanes and power stations.

Metallization and superconductivity of hydrides under high pressure

  • Kim, Duck Young
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권3호
    • /
    • pp.1-4
    • /
    • 2021
  • Hydrogen, the lightest and the most abundant element in the universe becomes a mainstay of contemporary condensed matter physics, which is largely because its metallization is regarded as the holy grail of high-pressure physics and it is also due to recent observations of high Tc superconductivity in hydrogen-dense compounds at extremely high pressure. Contemporary static high-pressure technique is not enough to realize the metallization of solid hydrogen and hydrogen-dense compounds may significantly reduce the required transition pressure providing an excellent proxy study. In this brief review, I will introduce recent achievements of high-pressure study in solid hydrogen and hydrides.

일 지역 성인의 고혈압 유병률 및 관리 실태 (A Study on the Prevalence Rate of Hypertension and the Actual Conditions of Control)

  • 김현옥
    • 지역사회간호학회지
    • /
    • 제10권1호
    • /
    • pp.154-172
    • /
    • 1999
  • In order to analyse the prevalence rate of hypertension and the actual conditions of control, we selected five districts out of eleven eups and myuns in Chinan Country. We administered structured questionaries to 309 adults above the age of 40, computerized the data using SPSS - PC+. More than 40.1% of adults over 40 in Chinan County have health disorders ranging from high blood pressure to hypertension including alert high blood pressure at 36.2%, relatively high. Among general characteristics, differences in the rate of hypertension were influenced by age, occupation and places of residence. Over 71 who are engaged in agriculture, who don't have jobs, who reside in Sungsu, Jungchun, Chinan-eup all have higher hypertension rates than other groups. Accordingly, the control of hypertension should be focused on these people. As a result of the control of blood pressure, the survey showed 93.0% of the subjects were checked mainly at hospitals clinics, health centers subhealth centers and community health posts more than once a year, relatively high level of blood pressure management. However, the difference between their blood pressure measurements at ordinary times and the level of blood pressure at the time of research was quite considerable. Only 47.3% of the subjects diagnosed with high blood pressure and 70.3% of the subjects with normal blood pressure recognized their blood pressure accurately 52.7% of the subjects diagnosed with high blood pressure showed errors in understanding their blood pressure at normal times. Because these errors can cause problems in the control of blood pressure, proper management should be executed through a systematic examination. As a result of the high blood pressure control condition, the average period of hypertension was 74.5( ${\pm}92.8$) months, 92.3% of the subjects were diagnosed with high blood pressure at hospitals clinics, health centers subhealth centers community health posts, but only 29.5% were examined after a general check up on high blood pressure was completed. 70.5% were diagnosed with high blood pressure only after measuring their blood pressure. 14.1% of the subjects were hospitalized because of falls influenced by high blood pressure. 33.3% attended hospitals and health centers regularily for medical treatment and this shows how low the rate of the control of blood pressure. Most people did not undergo medical treatment, because they had no painful symptoms (46.7%), they didn't need to take the medicine(28.9%), or they forget to take the medicine(20.0%). These problems in the control of hypertension were discovered in the process of diagnosing high blood pressure at health medical institutions. Many people did not recognize the need for consistent control of blood pressure. That is, although the diagnosis for high blood pressures performed at hospitals clinics, health centers subhealth centers and community health posts, was 92.3%, more than 70.5% of the subjects were not examined completely with regard to blood pressure. Accordingly, heath medical institutions must diagnose high blood pressure not only by only measuring blood pressure but also by using systematic process of examination. As for the people diagnosed with high blood pressure, one should perform consistent medical approaches and help them to recognize the importance of the continuous control of blood pressure through subject-oriented education. Problems the subjects experienced were the following numbness in the limbs easily paralyzed stitches in their shoulders which felt painful, stiff necks, occiputs felt heavy, headaches when they got up in the morning, felt dizzy when standing and moving their heads and poor eyesight. The rate of knowledge related to high blood pressure was 78.7 points, comparatively low. Whether they had normal blood pressure or hypertension made no difference. These results are not desirable. Adult-oriented education forgot the prevention and management of high blood pressure should be implemented. Hypertensive-oriented education should be especially reinforced. Because there was a difference in the level of knowledge according to age, academic career, occupation or place of residence, education related to hypertension should be intensified and focused on those over the age of 71 those who did not attend school, those who do not have jobs and are engaged in agriculture and residents living in Bugui, Jungchun regions. The degree of healthy life practice in hypertensives is poor, particularly weight control, as opposed to people who have normal blood pressure. It makes no difference in smoking, the amount of daily smoking, drinking, the control of salt because each result means that they are not practicing healthy life or modifying their life-style. The development and programs to improve a healthy life should be executed.

  • PDF

전자유압식 분사계에 의한 초고압 디젤분무의 입경분포에 관한 연구 (A Study on the Droplet Size Distribution of Ultra High Pressure Diesel Spray on Electronic Hydraulic Fuel Injection System)

  • 장세호;안수길
    • 동력기계공학회지
    • /
    • 제2권1호
    • /
    • pp.25-30
    • /
    • 1998
  • In order to investigate the droplet size distribution and Sauter Mean Diameter in a ultra high pressure diesel spray, fuel was injected with ultra high pressure into the environments of high pressure and room temperature by an Electronic Hydraulic Fuel Injection System. Droplet size was measured with the immersion liquid sampling technique. The immersion liquid was used a mixture of water-methycellulose solution and ethanol. The Sauter Mean Diameter decreased with increasing injection pressure, with a decrease environmental pressure (back pressure) and nozzle diameter. Increasing the injection pressure makes the fuel density distribution of the spray more homogeneous. An empirical correlation was developed among injection pressure, air density, nozzle diameter and the Sauter Mean Diameter of spray droplets.

  • PDF

고압에서의 분무의 증발 및 연소 현상에 관한 연구 (Study on Vaporization and Combustion of Spray in High Pressure Environment)

  • 왕태중;백승욱
    • 대한기계학회논문집B
    • /
    • 제27권9호
    • /
    • pp.1273-1281
    • /
    • 2003
  • The present study is mainly motivated to investigate the vaporization, auto-ignition, and combustion of liquid fuel spray injected into high pressure environment. The unsteady, multi-dimensional models were used for realistic simulation of spray as well as prediction of accurate ignition delay time. The Separated Flow (SF) model which considers the finite rate of transport between liquid and gas phases was employed to represent the interactions between spray and gas field. Among the SF models, the Discrete Droplet Model (DDM) which simulates the spray using finite number of representative samples of discrete droplets was adopted. The Eulerian-Lagrangian formulation was used to analyze the two-phase interactions. In order to predict an evaporation rate of droplet in high pressure environment, the high pressure vaporization model was applied using thermodynamic equilibrium and phase equilibrium at droplet surface. The high pressure effect as well as high temperature effect was considered in the calculation of liquid and gas properties. In case of vaporization, an interaction between droplets was studied through the simulation of spray. The interaction is shown up differently whether the ambient gas field is at normal pressure or high pressure. Also, the characteristics of spray behavior in high pressure environment were investigated through the comparison with normal ambient pressure case. In both cases, the spray behaviors are simulated through the distributions of temperature and reaction rate in gas field.

커먼레일 시스템용 저압 유압회로의 성능특성에 관한 연구 (A Study on the Performance Characteristics of Low Pressure Hydraulic Circuit of Common Rail System)

  • 이춘태
    • 동력기계공학회지
    • /
    • 제18권6호
    • /
    • pp.51-57
    • /
    • 2014
  • High pressure common rail injection technology has revolutionized the diesel industry. Over the last decade it has allowed engine builders to run higher injection pressures as much as above 1,300bar in order to increase engine efficiency, while reducing emissions. This common rail system has low pressure circuit which is consist of low pressure pump, cascade overflow valve and flow metering unit. The low pressure pump's purpose is to feed fuel oil to the high pressure pump. The cascade overflow valve keeps pressure in front of the metering unit constant and provides lubrication for the high pressure pump. The metering unit, known as the MPROP or fuel pressure regulator, regulates the maximum flow rate delivers to the rail. In this paper, we have investigated the performance characteristics of each components and total low pressure circuit of common rail system.

고주파 유압시스템에서 감치장치와 축압기에 의한 맥동 충격파 감쇄특성에 대한 연구 (Research for the Pulsating Pressure Characteristics by a Damper and an Accumulator in the High Frequency Hydraulic System)

  • 김양수;김재수;노형운
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.641-647
    • /
    • 2004
  • Characteristics of the high frequency pulsatile flow have been investigated experimentally to understand the flow phenomena in the hydraulic system. The accumulator in high frequency hydraulic system but that is not effective all frequency zone. Therefore, a hydraulic damper used with accumulator is suggested to reduce the high frequency pulsatile where the accumulator is not effective. The pulsating pressure obtained by Pressure measurement system are analyzed to power spectral density distribution. According to the variations of pump input pressure and actuator acceleration frequency, the pressure is measured with or without an accumulator or pulsatile damper The amplitude of pressure with damper is very lower than those without accumulator or damper due to absorbing function of damper. As the frequency of actuator acceleration is increased, the effect of damper becomes very important to decrease the amplitude of pulsatile Pressure waveform with high frequencies.

  • PDF

Preparation of High Quality Safflower (Carthamus tinctorius L.) Seed Extract by High-Pressure Extraction Process

  • Seo, Il-Ho;Choi, Sang-Won
    • Preventive Nutrition and Food Science
    • /
    • 제14권4호
    • /
    • pp.373-377
    • /
    • 2009
  • Safflower seed extract was prepared by a high-pressure extraction technology and its quality characteristics were compared to that of other conventional extraction techniques, such ultrasonic and reflux extractions. Safflower seeds were extracted with 80% aqueous ethanol by three above extraction methods, and further fractionated with Diaion HP-20 column chromatography to obtain a partially purified safflower seed extract (PPSSE). Among the three extraction techniques examined, the reflux extraction showed the higher yields of EtOH extract and PPE than the ultrasonic and high-pressure extractions. Levels of most phenolic compounds in the EtOH extract of safflower seed are higher in reflux and ultrasonic extractions than the high pressure extraction, but levels of two serotonin aglycones, N-(p-coumaroyl)serotonin (CS) and N-feruloylserotonin (FS), in PPSSE were higher in the high pressure extraction than the reflux and ultrasonic extractions. In addition, color values (L and a) of the PPSSE were higher in the high-pressure extraction than the reflux and ultrasonic extractions, although there were no significant differences in pH and UV maxima absorption spectra among three extraction techniques. These results indicate that the high-pressure extraction technology is a simple and effective extraction for preparation of a high quality of safflower seed extract containing CS and FS with anti-wrinkle activity.

최적화 설계를 통한 혼합가스 성능시험용 고온 고압 용기의 제작 (Manufacture of High-temperature High-pressure Vessel for Mixed Gas Performance Test via Optimized Design)

  • 구현곤;류형민;안재웅;배영관;김진희
    • 한국기계가공학회지
    • /
    • 제18권11호
    • /
    • pp.83-88
    • /
    • 2019
  • In this study, the high-temperature high-pressure vessel was successfully manufactured, which can be used to store pressurized air and to increase the temperature for the mix performance test of high-temperature high-pressure air with coolant (e.g., water). In this research, static structure analysis and transient thermal analysis were performed using the commercial software Midas NFX 2015 R1. Based on the results, the optimized pressure vessel design was carried out. As a result of the optimized design, the minimum stress and minimum weight were found at 120 mm of the vessel thickness, and the optimized pressure vessel was verified. Finally, through manufacture and performance test (e.g., the non-destructive inspection and hydraulic pressure test), the reliability and safety were validated for the designed pressure vessel.