• Title/Summary/Keyword: High power module

Search Result 921, Processing Time 0.043 seconds

An Experimental Study of Short Stack on the Performance of the Proton Exchange Membrane Fuel Cell for the Residential Power generation (소형 모듈 스택을 이용한 가정용 연료전지 성능의 실험적 고찰)

  • Choi, Won-Seok;Kim, Yong-Mo;Yu, Sang-Seok;Lee, Young-Duk;Hong, Dong-Jin;Ahn, Kook-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.21-24
    • /
    • 2008
  • Proton Exchange Membrane Fuel Cell (PEMFC) is an attractive candidate for residential power generator due to fast start-up and stop, high efficiency, low emission, and high power density. In this study, we employ short module stack to understand the performance of the unit cell of the stack in terms of operating temperatures. To simulate the practical fuel cell stack of residential power generator, the structure and active area of the short module stack is kept the same as that of the practical fuel cell. The results shows that the electric potential of short module stack is different from the number of cells times the potential of unit cell because of cell-to-cell variation.

  • PDF

High-Efficiency Power Conditioning System for Grid-Connected Photovoltaic Modules

  • Choi, Woo-Young;Choi, Jae-Yeon
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.561-567
    • /
    • 2011
  • This paper presents a high-efficiency power conditioning system (PCS) for grid-connected photovoltaic (PV) modules. The proposed PCS consists of a step-up DC-DC converter and a single-phase DC-AC inverter for the grid-connected PV modules. A soft-switching step-up DC-DC converter is proposed to generate a high DC-link voltage from the low PV module voltage with a high-efficiency. A DC-link voltage controller is presented for constant DC-link voltage regulation. A half-bridge inverter is used for the single-phase DC-AC inverter for grid connection. A grid current controller is suggested to supply PV electrical power to the power grid with a unity power factor. Experimental results are obtained from a 180 W grid-connected PV module system using the proposed PCS. The proposed PCS achieves a high power efficiency of 93.0 % with an unity power factor for a 60 Hz / 120 Vrms AC power grid.

Development and characterization of a ultra-wide bandwidth video detector for the UHF partial discharge monitoring system (UHF 부분방전 감시 장치를 위한 초광대역 검출장치 개발 및 특성조사)

  • Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1649-1651
    • /
    • 2002
  • Ultra-wide bandwidth (UWB) detection method has been widely used as a front end detection scheme for the ultra-high frequency (UHF) partial discharge (PD) monitoring systems. A broad-band video detector module was developed and characterized for the UHF UWB PD detection systems. The useable bandwidth of the module is more than 2 GHz and it is optimized for 50-ohm systems. The detection sensitivity and dynamic range of the module were characterized by using a known ns-width RF pulses of GHz range. The dynamic range is more than 6-decades and the module can detect pulsed RF signals down to 1 nW. The detector module can eliminate expensive equipment such as high speed oscilloscopes and radio frequency (RF) spectrum analyzers. Therefore, it enables one to use slow speed data acquisition systems for the PD monitoring at the UHF range. The detector module was used to detect real PDs of about <3 pC. The module converts the UWB PD signals into a low-bandwidth video signal with a high signal-to-noise ratio.

  • PDF

Module UPS of multi-parallel operation for use in information & telecommunication systems (정보통신용 다병렬 운전의 모듈식 무정전전원장치)

  • Koo, Tae-Geun;Ryu, Ji-Su;Bae, Sang-Gyu;Park, Keun-Kap
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.390-393
    • /
    • 2007
  • The reliability as well as the power capability of the UPS system can be increased by replacing a single UPS unit with multiple small UPS units in parallel, resulting in a so-called module UPS. This module UPS system allows that a new module can be added or replaced while maintaining power to loads, which is a hot-swappable operation. In addition, it has desirable features such as ease of output power expandability, convenience of maintenance and repair, and high reliability. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. 5kVA modules are designed and implemented to confirm the effectiveness of the proposed approaches. Experimental results show that the module UPS system has a high power factor, a low distortion of output voltage and input current, hot-swappable operations and good load sharing characteristics.

  • PDF

Resonant Step-Down DC/DC Converter to Reduce Voltage Stresses of Motor Driving Inverter under 3-phase AC Utility Line Condition (3상 전원 조건의 모터 구동 인버터 내압 저감을 위한 공진 강압형 DC/DC 컨버터)

  • Kang, Kyung-Soo;Kim, Sang-Eon;Lee, Joon-Hwan;Roh, Chung-Wook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.391-398
    • /
    • 2014
  • This paper presents a resonant step-down DC/DC converter to reduce the voltage stresses of a 3-phase inverter module under the three-phase AC utility line condition. Under this condition, a conventional 3-phase inverter module suffers from high voltage stresses as a result of the high rectified DC link voltage; hence, a high-cost high-voltage-rating inverter module must be used. However, using the proposed converter, a low-cost low-voltage-rating inverter module may be adopted to drive the motor even under the 3-phase AC line condition. The proposed converter, which can be realized with small size inductor and low-voltage-rating semiconductor devices, operates at a high-efficiency mode because of the zero-current switching operations of all the semiconductor devices. The operational principles are explained and a design example is provided in the study. Experimental results demonstrate the validity of the proposed converter.

Development of UPS Embedded in Computer using Micom and GUI (마이컴과 GUI를 이용한 컴퓨터 내장형 UPS의 개발)

  • Kim, D.W.;Park, J.H.;Hwang, K.H.;Woo, J.I.;Jung, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2288-2291
    • /
    • 2004
  • In this paper, UPS, which is embedded in computer, is developed against the poor utility power system. In the developed system, PIC16C74A is used as the main controller, and UPS system consists of micom control module, power failure detecting module, charging module, power module, synchronous transfer module, and GUI module. Additionally, GUI module consists of battery charging state unit, power operating unit and operating state unit.

  • PDF

The Study of Inverter Module with applying the RC(Reverse Conduction) IGBT (RC(Reverse Conduction) IGBT를 적용한 Inverter Module에 대한 연구)

  • Kim, Jae-Bum;Park, Shi-Hong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.359-359
    • /
    • 2010
  • IGBT(Insulated Gate Bipolar Transistor) 란 MOS(Metal Oxide Silicon) 와 Bipolar 기술의 결정체로 낮은 순방향 손실(Low Saturation)과 빠른 Speed를 특징으로 기존의 Thyristor, BJT, MOSFET 등으로 실현 불가능한 분양의 응용처를 대상으로 적용이 확대 되고 있고, 300V 이상의 High Power Application 영역에서 널리 사용되고 있는 고효율, 고속의 전력 시스템에 있어서 필수적으로 이용되는 Power Device이다. IGBT는 출력 특성 면에서 Bipolar Transistor 이상의 전류 능력을 가지고 있고 입력 특성 면에서 MOSFET과 같이 Gate 구동 특성을 갖기 때문에 High Switching, High Power에 적용이 가능한 소자이다. 반면에, Conventional IGBT는 MOSFET과 달리 IGBT 내부에 Anti-Parallel Diode가 없기 때문에 Inductive Load Application 적용시에는 별도의 Free Wheeling Diode가 필요하다. 그래서, 본 논문에서 별도의 Anti-Parallel Diode의 추가 없이도 Inductive Load Application에 적용 가능한 RC IGBT를 적용하여 600V/15A급 Three Phase Inverter Module을 제안 하고자 한다.

  • PDF

Design of a Highly Integrated Palette-type High Power Amplifier Module Using GaN Devices for DPD Application (질화갈륨 소자를 이용한 DPD용 고집적 팔렛트형 고출력증폭기 모듈 설계)

  • Oh, Seong-Min;Lim, Jong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.5
    • /
    • pp.2241-2248
    • /
    • 2011
  • This paper describes the design of a palette-type 60watt high power amplifier module using gallium nitride(GaN) devices with high power and efficiency performances for WiMAX and LTE systems. The line-up for the high gain amplifier module consists of the pre-amplifier stage with low power and high gain, 8watt GaN driving amplifier stage, and 60watt GaN high power amplifier stage of Doherty structure with two 30watt GaN devices. The obtained gain is 61.4dB with an excellent gain flatness of ${\pm}$0.075dB over 2.5~2.68GHz. GaN devices and the Doherty structure are adopted for the improvement of high efficiency and output power. The measurement for the fabricated high power amplifier module of palette type is performed using the widely known WiMAX signal all over the world. In the example of RRH(remote radio head) application of the fabricated amplifier module, the measured efficiency is 37~38% with the 10watts of modulated output power. It is shown that when the fabricated amplifier module is activated with a digital predistorter(DPD), the measured ACLR is better than 46dBc under the 10watts of modulated output power.

A Study on the Characteristics and Fabrication of Switching Power Module for High Efficiency and Small Size of Power Supply System (전원장치의 소형화와 고효율화를 위한 스위칭 파워 모듈의 제작과 특성에 관한 연구)

  • Kim, Chan;Jeon, Eui-Seok;Kang, Do-Young;Kim, Byung-Cheul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.758-761
    • /
    • 2003
  • We have designed 5 V/500 mA transless type power module by using semiconductor switching technique, key technique for small size of power supply system. The power module is suitable to a small sized electronic system using a single power supply. It is composed of switching circuit using voltage drop type chopper method, control circuit, voltage detect circuit, and constant voltage circuit, and is fabricated to hybrid-IC type. The switching regulator power supply circuit, designed in this study, has satisfied the electrical characteristics of 5 V/500 mA transless type power module.

  • PDF

Numerical Prediction of Solder Fatigue Life in a High Power IGBT Module Using Ribbon Bonding

  • Suh, Il-Woong;Jung, Hoon-Sun;Lee, Young-Ho;Choa, Sung-Hoon
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1843-1850
    • /
    • 2016
  • This study focused on predicting the fatigue life of an insulated gate bipolar transistor (IGBT) power module for electric locomotives. The effects of different wiring technologies, including aluminum wires, copper wires, aluminum ribbons, and copper ribbons, on solder fatigue life were investigated to meet the high power requirement of the IGBT module. The module's temperature distribution and solder fatigue behavior were investigated through coupled electro-thermo-mechanical analysis based on the finite element method. The ribbons attained a chip junction temperature that was 30℃ lower than that attained with conventional round wires. The ribbons also exhibited a lower plastic strain in comparison with the wires. However, the difference in plastic strain and junction temperature among the different ribbon materials was relatively small. The ribbons also exhibited different crack propagation behaviors relative to the wires. For the wires, the cracks initiated at the outmost edge of the solder, whereas for the ribbons, the cracks grew in the solder layer beneath the ribbons. Comparison of fatigue failure areas indicated that ribbon bonding technology could substantially enhance the fatigue life of IGBT modules and be a potential candidate for high power modules.