• Title/Summary/Keyword: High performance simulation

Search Result 4,643, Processing Time 0.035 seconds

A Study on Variable Damping Semi-Passive Vibration Isolation for Enhancing Pointing Performance of On-Board Payload (위성 탑재채 지향성능 향상을 위한 가변댐핑 반수동 진동제어에 관한 연구)

  • OH, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.6
    • /
    • pp.533-538
    • /
    • 2007
  • A semi-passive vibration isolation control method for enhancing pointing performance of on-board payload has been derived, and its effectiveness has been evaluated through numerical simulation. The semi-passive control law proposed in this study was derived so as to obtain the same performance as a high passive damping at low frequencies and obtain the same performance as a passive low damping at high frequencies. In the numerical simulation, the intended vibration isolation performance of the semi-passive control law has been obtained.

A Study on the Condensation Performance of Curtain-wall Window in High-Rise Residential Building (초고층 주거건물 커튼월의 창호부 결로 성능평가에 관한 연구)

  • Seok Ho-Tae;Chung Man-Seok;Kwak Hyun-Chul;Kwon Jong-Wook
    • Journal of the Korean housing association
    • /
    • v.16 no.4
    • /
    • pp.81-89
    • /
    • 2005
  • The purpose of this thesis is thermal performance simulation about various type that can apply in the high-rise residential building to estimate condensation performance of window that is consisted of frame and glazing in curtain wall. The result of this thesis are summarized as follows. First, condensation occurrence point when relative humidity is $30{\cdot}40{\cdot}50\%$ is shortest Low-e double glass. Difference by type of gas and spacer was a little by $2{\~}6$ cm, among it, the case that apply krypton in gas and the case that apply double seal in spacer were less condensation occurrence distribution. Second, when analyzed improved proposal of window and existing plan through simulation, improved proposal is superior from general side of the interior and exterior temperature, thermal break surrounding temperature and temperature of frame end, condensation occurrence point etc. Therefore, if it was used improved proposal with effect that improve in curtain wall of high-rise residential building, it may improve window condensation performance of curtain wall.

Modeling the transverse connection of fully precast steel-UHPC lightweight composite bridge

  • Shuwen Deng;Zhiming Huang;Guangqing Xiao;Lian Shen
    • Advances in concrete construction
    • /
    • v.15 no.6
    • /
    • pp.391-404
    • /
    • 2023
  • In this study, the modeling of the transverse connection of fully precast steel-UHPC (Ultra-High-Performance Concrete) lightweight composite bridges were conducted. The transverse connection between precast components plays a critical role in the overall performance and safety of the bridge. To achieve an accurate and reliable simulation of the interface behavior, the cohesive model in ABAQUS was employed, considering both bending-tension and compression-shear behaviors. The parameters of the cohesive model are obtained through interface bending and oblique shear tests on UHPC samples with different surface roughness. By validating the numerical simulation against actual joint tests, the effectiveness and accuracy of the proposed model in capturing the interface behavior of the fully precast steel-UHPC lightweight composite bridge were demonstrated.

Design of an Adaptive High-Gain Observer for Speed-Sensorless Control of Motor (전동기 센서리스제어를 위한 적응 고이득 관측기 설계)

  • Kim, Sang-Hun;Yoon, Kwang-Ho;Nam, Moon-Hyun;Kim, Lark-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.484-487
    • /
    • 2003
  • In this paper describes a design of Adaptive high gain observer. The gain of the observer is properly set up using the fuzzy control and adaptive high gain observer that have a superior transient characteristic and is easy to implement compared the existing method is designed. In order to verify the performance of the Adaptive high gain observer which is proposed in this paper, it is compared estimate performance of High-gain Observer and Adaptive High Gain Observer with the computer simulation. Effectiveness of the proposed high gain observer is proved from the simulation to compare the case with a speed sensor to the case with Adaptive high gain observer in the speed control of DC servo motor.

  • PDF

Development and effects of a labor nursing education program using a high-fidelity simulator for nursing students (간호대학생 대상의 고충실도 시뮬레이터를 이용한 분만 간호 교육 프로그램의 개발 및 효과)

  • Park, Seo-A;Kim, Hye Young
    • Women's Health Nursing
    • /
    • v.26 no.3
    • /
    • pp.240-249
    • /
    • 2020
  • Purpose: This study was conducted to investigate the effects of an education program using a high-fidelity simulator of labor and delivery on nursing knowledge, critical thinking, and clinical performance among nursing students who had not yet experienced clinical practicum. Methods: The development of a 5-week maternity nursing education programs using high-fidelity simulators included modules containing case-oriented scenarios, knowledge, and skills required for maternity care. A randomized controlled study was conducted to verify the effects of the developed program. Data were collected from October 21 to December 9, 2019. The experimental group (n=36) participated in a 5-week high-fidelity simulation program on care for the woman in labor, whereas the control group (n=36) received standard education as lecture and practice with delivery model. The collected data were analyzed using descriptive statistics (frequency, percentage, mean, and standard deviation), the Chi-square test, Fisher exact test, and t-test. Results: For participants who received education using the high-fidelity simulation program, nursing knowledge (t=2.33, p=.011), critical thinking (t=3.73, p<.001), and clinical performance (t=2.53, p=.006) were significantly higher than in the control group. Conclusion: Even for students with no clinical experience, high-fidelity simulation-based nursing education was effective in improving nursing knowledge, critical thinking, and clinical performance among nursing students. Nurse educators will be able to use this high-fidelity simulator effectively, especially in situations where direct clinical practicum may not be feasible.

A Study on the Performance Analysis of a High-Speed ATM Router (고속 ATM 라우터의 성능 분석에 관한 연구)

  • 조성국
    • Journal of the Korea Society of Computer and Information
    • /
    • v.6 no.1
    • /
    • pp.74-81
    • /
    • 2001
  • In this paper. the architecture of a high-speed ATM router using ATM switch is studied and the performance of the high-speed ATM router is analyzed through simulation. The high-speed ATM router using ATM switch is able to reduce the load of router and the processing time of a packet in the router. The size of router buffers has been studied through simulation processes for the analysis of performance capacity in due course of making changes in routing time(RT), which is the performance capacity parameters of high-speed ATM routers, flow table size(FS), flow live time(FT) and input circuit efficiencies. The result of this study can be used as the source material for analyzing the suitability of equipment in upgrading networks and applying high-speed ATM routers by using ATM switches.

  • PDF

High-speed Performance of Single Flux Quantum Circuits Test Probe (단자속 양자 회로 측정용 고속 프로브의 성능 시험)

  • 김상문;최종현;김영환;강준희;윤기현;최인훈
    • Progress in Superconductivity
    • /
    • v.4 no.1
    • /
    • pp.74-79
    • /
    • 2002
  • High-speed probe made to test single flux quantum(SFQ) circuits was comprised of semi-rigid coaxial cables and microstrip lines. The impedance was set at 50 $\Omega$to carry high-speed signals without much loss. To do performance test of high-speed probe, we have attempted to fabricate a test chip which has a coplanar waveguide(CPW) structure. Electromagnetic simulation was done to optimize the dimension of CPW so that the CPW structure has an impedance of 50$\Omega$, matching in impedance with the probe. We also used the simulation to investigate the effect of the width of signal line and the gap between signal line and ground plane to the characteristics of CPW structure. We fabricated the CPW structure with a gold film deposited on Si wafer whose resistivity was above $1.5\times$10$_4$$\Omega$.cm. The magnitudes of S/sub 21/ of CPW at 6 ㎓ in simulations and in the actual measurements done with a network analyzer were: -0.1 ㏈ and -0.33 ㏈ (type A),-0.2 ㏈ and -0.48 ㏈ (type B), respectively. Using the test chip, we have successfully tested the performance of high-speed probe made for SFQ circuits. The probe showed the good performance overthe bandwidth of 10 ㎓.

  • PDF

Study on target erosion in rocking magnet sputtering system

  • Lee, Do-Sun;Kwon, Ui-Hui;Lee, Won-Jong
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.4
    • /
    • pp.245-251
    • /
    • 2005
  • A high performance dual rocking magnet sputtering gun has been developed. The rocking magnet sputtering gun introduces full-face erosion by rapidly rocking the magnet in the region where the high plasma density is maintained. The newly developed dual rocking magnet sputtering gun whose target utilization was 77 percent achieved high performance in quality in the view of target utilization and target life-time comparing to the existing magnetron sputtering gun. The PIC-MCC target erosion simulation has been performed simultaneously. Comparing experimental target erosion profiles with simulated target erosion profiles, the simulation could estimate the tendency of the target erosion profiles but could not estimate an exact target erosion profile. If the simulation were improved more precisely, the cost reduction for the development of the multiple rocking magnet sputtering gun would be expected.

A Study on Fluctuating Pressure Load on High Speed Train Passing through Tunnels

  • Seo Sung-Il;Park Choon-Soo;Min Oak-Key
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.482-493
    • /
    • 2006
  • The carbody structure of a high speed train passing through a tunnel is subjected to pressure fluctuation. Fatigue strength of the carbody structure against the fluctuating pressure loading should be proved in the design stage for safety. In this study, to get the useful information on the pressure fluctuation in the tunnel, measurement has been conducted during test running of KHST on the high speed line for two years. The measured results were analyzed and arranged to be used for carbody design. A prediction method for the magnitude and frequency of pressure change was proposed and the propagating characteristics of pressure wave was investigated. By statistical analysis for the measured results, a pressure loading spectrum for the high speed train was given. The proposed method can also be used to estimate the pressure loading spectrum for new high speed line at design stage combined with the results of train performance simulation.

The Effects of a Simulation-Based High Flow Nasal Cannula Oxygen Therapy Training Program on the Knowledge, Clinical Performance and Educational Satisfaction of Clinical Nurses (시뮬레이션기반 고유량산소요법 교육 프로그램이 임상간호사의 지식, 임상수행능력 및 교육만족도에 미치는 효과)

  • Jang, Kyung Soon;Ryu, Kyeong Hee;Kang, Hyeon Mo;Kang, In Hwa;Kwon, Jeong Hui;Lee, Gyeong Mi;Nam, Yun Jung;Seo, Mi Hye;Kim, Ji Yeon;Jung, Ji Yun;Kim, Hyun Ji;Bae, Hye Min
    • Journal of Korean Clinical Nursing Research
    • /
    • v.26 no.1
    • /
    • pp.47-58
    • /
    • 2020
  • Purpose: The aim of this study was to develop a simulation-based High Flow Nasal Cannula Oxygen Therapy training program based on NLN/ISF to identify the effect on knowledge, clinical performance, and educational satisfaction compared to a group who had traditional High Flow Nasal Cannula Oxygen Therapy training after applying it to clinical nurses. Methods: 31 experimental groups and 33 control groups were conducted from August 2019 to September 2019 for inexperienced nurses over 4 months to 5 years with no experience using high-flow oxygen therapy. Educational programs were developed in scenarios according to Airvo2 and Optiflow, such as facilitator, participant, educational condition, design, characteristics, and educational outcomes. The education application was conducted in advanced for knowledge and clinical performance ability after watching therapy video. Since then, a total of 90 minutes have been conducted for respiratory failure theory training, airvo2 and optiflow simulation training, and debriefing. After applying the education, the medical institution measured nurses' knowledge, clinical performance, and education satisfaction. Data were analyzed using descriptive statistics, with the SPSS/WIN 22.0 program. Results: Both knowledge and educational satisfaction were higher in the experimental group than in the control group (t=-14.09, p<.001), (t=-12.99, p<.001). The clinical performance for both use of Optiflow and Airvo2 were higher in the experimental group than in the control group (t=-11.39, p<.001), (t=-11.38, p<.001). Conclusion: Results showed that the simulation-based High Flow Nasal Cannula Oxygen Therapy training was effective with the experimental group having increased scores for every area of this study.