• Title/Summary/Keyword: High performance

Search Result 35,953, Processing Time 0.056 seconds

고성능 표면침투제가 도포된 콘크리트의 복합열화저항성 평가 (The Evaluation of Resistance of Multi-degregation on Concrete Coated High Performance Penetration Agency)

  • 유성원;서정인;하헌재;이상민;박상순
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.241-244
    • /
    • 2004
  • The evaluation of Single or multi-degregation of concrete coated by high performance surface penetration agency was examined through various tests, i.e., carbonation, absorption, carbonation + chloride ion and carbonation + chemical solution according to various high performance surface penetration agencies and various compressive strengths of base concrete. The 2 types of high performance surface penetration agencies were used i.e., inorganic and alcohol soluble. And 2 types of compressive strength of base concrete were used such as 21 30. MPa. The characteristics of concrete coated high performance surface penetration agency was more improved than that of non-coated concrete, and especially, water soluble inorganic agency was most effective. And if compressive strength of base concrete was low, the improved effects would be larger.

  • PDF

1종 및 4종시멘트를 이용한 고성능 콘크리트의 자기수축 및 건조수축 특성 (A Characteristic of Autogenous shrinkage and Dry shrinkage for High Performance Concrete Using Type I and Type IV Cement)

  • 이웅종;유재상;이종열
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.561-564
    • /
    • 2004
  • In this study, the properties of autogenous shrinkage and dry shrinkage for high performance concrete using Type I and Type IV cement were discussed. According to experimental results, autogenous shrinkage of SN30(the high performance concrete using type I cement) shows values higher than SL30( the high performance concrete using type IV cement). But the dry shrinkage of SN30 is almost the same as SL30. It is observed that the total shrinkage strain of SN30 is higher than that of SL30, because the ratio of autogenous shrinkage of the total shrinkage is relatively large. Therefore, SL30 is more effective to control or minimize the cracking of the high performance concrete, compared with SN30.

  • PDF

고성능 표면침투제가 도포된 콘크리트의 물리특성 (Physical Characteristics of Concrete Coated High Performance Surface Penetration Agency)

  • 유성원;서정인;하헌재;이상민;이상근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.809-812
    • /
    • 2004
  • The evaluation of characteristics of concrete coated by high performance surface penetration agency was examined through various tests, i.e., compressive strength, penetration depth, water and air permeability, absorption according to various high performance surface penetration agencies and various compressive strengths of base concrete. The 4 types of high performance surface penetration agencies were used i.e., organic, inorganic, water soluble, and alcohol soluble. And 3 types of compressive strength of base concrete were used such as 21, 24 and 30 MPa. The characteristics of concrete coated high performance surface penetration agency was more improved than that of non-coated concrete, and especially, water soluble inorganic agency was most effective. And if compressive strength of base concrete was low, the improved effects would be larger.

  • PDF

Bandwidth-aware Memory Placement on Hybrid Memories targeting High Performance Computing Systems

  • Lee, Jongmin
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권8호
    • /
    • pp.1-8
    • /
    • 2019
  • Modern computers provide tremendous computing capability and a large memory system. Hybrid memories consist of next generation memory devices and are adopted in high performance systems. However, the increased complexity of the microprocessor makes it difficult to operate the system effectively. In this paper, we propose a simple data migration method called Bandwidth-aware Data Migration (BDM) to efficiently use memory systems for high performance processors with hybrid memory. BDM monitors the status of applications running on the system using hardware performance monitoring tools and migrates the appropriate pages of selected applications to High Bandwidth Memory (HBM). BDM selects applications whose bandwidth usages are high and also evenly distributed among the threads. Experimental results show that BDM improves execution time by an average of 20% over baseline execution.

내화 마감재 종류에 따른 고성능 RC기둥의 폭열방지 및 온도이력 특성 (Properties of Temperature History and Spatting Resistance of High Performance RC Column with Finishing Material)

  • 허영선;김기훈;이진우;이보형;이재삼;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.37-40
    • /
    • 2005
  • High Performance Concrete(HPC) has been widely used in high-rise building. The HPC has several benefits including high strength, high fluidity and high durability. However. spatting is susceptible to occur in HPC and HPC also tends to be deteriorated in the side of fire resistance performance at fire. This paper focuses on the analysis of the temperature history and residual compressive strength with finishing material, in order to protect HPC from sudden-high-temperature, which is one of the main reason spatting occurs. Test results show that spalling occurs in all specimens. The most serious spalling took placed in HPC covering fire enduring spray-on material, whose covering thickness is 20mm but temperature history indicates that fire enduring spray effectively protected HPC from fire for more than 2hours. In addition, residual compressive strength ratio of HPC using fire enduring paint was more than $90\%$ of original strength, thus minimizing spatting and indicating significant fire resistance performance.

  • PDF

High Performance Computing 환경을 위한 고성능, 무정지 파일시스템 구현 (The development of the high effective and stoppageless file system for high performance computing)

  • 박영배;최승환;이상호;김경수;공용준
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2004년도 추계 종합학술대회 논문집
    • /
    • pp.395-401
    • /
    • 2004
  • In the current high network-centralized computing and enterprising environment, it is getting essential to transmit data reliably at very high rates. Until now previous client/server model based NFS(Network File System) or AFS(Andrew's Files System) have met the various demands but from now couldn't satisfy those of the today's scalable high-performance computing environment. Not only performance but data sharing service redundancy have risen as a serious problem. In case of NFS, the locking issue and cache cause file system to reboot and make problem when it is used simply as ip-take over for H/A service. In case of AFS, it provides file sharing redundancy but it is not possible until the storage supporting redundancy and equipments are prepared. Lustre is an open source based cluster file system developed to meet both demands. Lustre consists of three types of subsystems : MDS(Meta-Data Server) which offers the meta-data services, OST(Objec Storage Targets) which provide file I/O, and Lustre Clients which interact with OST and MDS. These subsystems with message exchanging and pursuing scalable high-performance file system service. In this paper, we compare the transmission speed of gigabytes file between Lustre and NFS on the basis of concurrent users and also present the high availability of the file system by removing more than one OST in operation.

  • PDF

연속재생 DPF의 재생 성능에 미치는 차량 운행패턴의 영향 (Influence of Driving Pattern on Regeneration Performance of Continuously Regenerating Diesel Particulate Filter)

  • 황진우;이창식
    • 대한기계학회논문집B
    • /
    • 제33권5호
    • /
    • pp.358-364
    • /
    • 2009
  • This paper is to investigate the influence of driving patterns of slow and high speed vehicles on the performance of continuously regenerating diesel particulate filter(DPF) system matched with operating conditions in field application. The DPF performance test for field application was carried out for two identical DPFs installed to slow and high speed vehicles. A slow speed vehicle was selected among local buses which have driving patterns to repeat running and stop frequently, while a high speed vehicle was prepared to have long route of high speed over 60km/h like inter-city buses. In this test, the regeneration performance on the DPF of slow speed vehicle deteriorated because of high soot load index(SLI) in spite of same balance point temperature(BPT) distribution for high speed vehicle. The DPF of slow speed vehicle melted in the end because the rapid increase of back pressure caused high temperature over $1200^{\circ}C$ in the ceramic wall of DPF. The PM components like ash collected to the filter in the DPF were analyzed in order to investigate the cause of the defect and provide an operation performance of DPF system. In the result of the analysis, high levels of lubrication oil ash(Ca, Mg, P, Zn) were detected.

리튬이온전지 음극의 고속 성능 향상을 위한 도전재 복합화 (Composited Conductive Materials for Enhancing the Ultrafast Performance for Anode in Lithium-Ion Battery)

  • 성기욱;안효진
    • 한국재료학회지
    • /
    • 제32권11호
    • /
    • pp.474-480
    • /
    • 2022
  • Lithium-ion batteries (LIBs) are powerful energy storage devices with several advantages, including high energy density, large voltage window, high cycling stability, and eco-friendliness. However, demand for ultrafast charge/discharge performance is increasing, and many improvements are needed in the electrode which contains the carbon-based active material. Among LIB electrode components, the conductive additive plays an important role, connecting the active materials and enhancing charge transfer within the electrode. This impacts electrical and ionic conductivity, electrical resistance, and the density of the electrode. Therefore, to increase ultrafast cycling performance by enhancing the electrical conductivity and density of the electrode, we complexed Ketjen black and graphene and applied conductive agents. This electrode, with the composite conductive additives, exhibited high electrical conductivity (12.11 S/cm), excellent high-rate performance (28.6 mAh/g at current density of 3,000 mA/g), and great long-term cycling stability at high current density (88.7 % after 500 cycles at current density of 3,000 mA/g). This excellent high-rate performance with cycling stability is attributed to the increased electrical conductivity, due to the increased amount of graphene, which has high intrinsic electrical conductivity, and the high density of the electrode.

고성능 아연-이온 전지의 고품질 집전체를 위한 그래핀 필름의 결함 제어 (Controlling Defects in Graphene Film for Enhanced-Quality Current Collector of Zinc-Ion Batteries with High Performance)

  • 이영근;안건형
    • 한국재료학회지
    • /
    • 제33권4호
    • /
    • pp.159-163
    • /
    • 2023
  • Zinc-ion Batteries (ZIBs) are currently considered to be effective energy storage devices for wearable electronics because of their low cost and high safety. Indeed, ZIBs show high power density and safety compared with conventional lithium ion batteries (LIBs) and exhibit high energy density in comparison with supercapacitors (SCs). However, in spite of their advantages, further current collector development is needed to enhance the electrochemical performance of ZIBs. To design the optimized current collector for high performance ZIBs, a high quality graphene film is suggested here, with improved electrical conductivity by controlling the defects in the graphene film. The graphene film showed improved electrical conductivity and good electron transfer between the current collector and active material, which led to a high specific capacity of 346.3 mAh g-1 at a current density of 100 mA g-1, a high-rate performance with 116.3 mAh g-1 at a current density of 2,000 mA g-1, and good cycling stability (68.0 % after 100 cycles at a current density of 1,000 mA g-1). The improved electrochemical performance is firmly because of the defects-controlled graphene film, leading to improved electrical conductivity and thus more efficient electron transfer between the current collector and active material.

Study on the relationship between trust and organizational performance in local administrative organization- Focused on the local administrative organizations in Gangwondo-

  • Kim, Sun-Ok;Park, Sung-Yong;Lee, Hee-Choon
    • Journal of the Korean Data and Information Science Society
    • /
    • 제21권5호
    • /
    • pp.983-997
    • /
    • 2010
  • This study is to explore the relationship between trust in local administrative organization and organizational performance. Local administrative organizations provide the citizens with administrative services. Heightening the organizational performance contributes the citizens' happiness and the stream of times through organizations' change. To provide high quality of administrative service to citizens, trust in organizations is more important than any other capital. The improvement of organizational performance needs through this social capital. Factors about trust variables and organizational performance variables are extracted through the theoretical discussions. To do the research, public servants in 7 local administrative organizations of Gangwondo were asked to do the survey about how trust in organizations affects organizationa performances. The results explain that trust variables are related to organizational performance, and the local administrative organization which is high in trust is high in organizational performance. Trust in local administrative organizations improves the organizational performance internally and the organization will obtain trust from the citizens externally.