• 제목/요약/키워드: High intensity

검색결과 4,621건 처리시간 0.032초

A of Radiation Field with a Developed EPID

  • Y.H. Ji;Lee, D.H.;Lee, D.H.;Y.K. Oh;Kim, Y.J.;C.K. Cho;Kim, M.S.;H.J. Yoo;K.M. Yang
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.67-67
    • /
    • 2003
  • It is crucial to minimize setup errors of a cancer treatment machine using a high energy and to perform precise radiation therapy. Usually, port film has been used for verifying errors. The Korea Cancer Center Hospital (KCCH) has manufactured digital electronic portal imaging device (EPID) system to verify treatment machine errors as a Quality Assurance (Q.A) tool. This EPID was consisted of a metal/fluorescent screen, 45$^{\circ}$ mirror, a camera and an image grabber and could display the portal image with near real time KIRAMS has also made the acrylic phantom that has lead line of 1mm width for ligh/radiation field congruence verification and reference points phantom for using as an isocenter on portal image. We acquired portal images of 10$\times$10cm field size with this phantom by EPID and portal film rotating treatment head by 0.3$^{\circ}$, 0.6$^{\circ}$ and 0.9$^{\circ}$. To check field size, we acquired portal images with 18$\times$18cm, 19$\times$19cm and 20$\times$20cm field size with collimator angle 0$^{\circ}$ and 0.5$^{\circ}$ individually. We have performed Flatness comparison by displaying the line intensity from EPID and film images. The 0.6$^{\circ}$ shift of collimator angle was easily observed by edge detection of irradiated field size on EPID image. To the extent of one pixel (0.76mm) difference could be detected. We also have measured field size by finding optimal threshold value, finding isocenter, finding field edge and gauging distance between isocenter and edge. This EPID system could be used as a Q.A tool for checking field size, light/radiation congruence and flatness with a developed video based EPID.

  • PDF

16종 천연물 추출물의 여성질염 활성성분 및 면포 염착 효과 (Female Vaginitis Active Ingredients of 16 Kinds Natural Herbal Medicine Extracts and Dyeing Effect on Cotton Fabric)

  • 김현경;이윤기;최수빈;김도완
    • 문화기술의 융합
    • /
    • 제9권1호
    • /
    • pp.725-733
    • /
    • 2023
  • 천연물 16종의 물 추출물 및 50% 에탄올 추출물들에 대한 기능성 활성성분 및 면포 염착효과를 알아본 결과, 색도 강도는 차이가 있었으나 적색 6종, 황색 5종, 오렌지색 2종 및 녹색 3종 이었고, 대체로 50% 에탄올 추출액의 색도가 높고 선명하였다. 이와 같은 천연물들의 물 추출물 및 50% 에탄올 추출물에 면포 거즈를 2일간 침지하여 염색한 결과 염색효과는 대체로 양호하였으며, 실온에서 건조 후 개봉하여 보관하여도 색도의 퇴색 감소는 거의 없는 것으로 관찰되었다. 천연물 16종의 물추출물의 pH는 중성 내지는 약산성으로 피부에 부작용이 없는 중성~약산성 범위였다. DPPH 유리라디칼 억제 항산화효과는 시료 별로 50% 에탄올 추출물의 효과가 물추출물에 비하여 양호하였고, 특히 황금, 유백피, 유근피, 박하, 홍화 등의 효과가 양호하였다. 폴리페놀 함량도 대체로 50% 에탄올 추출물의 함량이 물 추출물에 비하여 높은 경향이었고, 특히 금은화, 유근피, 황금, 유백피, 홍화 등의 효과가 양호하였다. 따라서 천연물 16종 추출물에 대한 항산화 활성과 여성질염 예방의 상관 관계를 규명하고자 하였다.

고객상담사의 감정노동이 직무스트레스에 미치는 영향: 그릿과 사회적 지원의 조절효과를 중심으로 (The Effect of Emotional Labor on Job Stress in Customer Counselors: The Moderating Effect of Grit and Social Support)

  • 이수진;한천우
    • 한국융합학회논문지
    • /
    • 제13권1호
    • /
    • pp.269-282
    • /
    • 2022
  • 본 연구는 감정노동이 직무스트레스에 미치는 영향을 탐색하는 것뿐만 아니라 감정노동과 직무스트레스의 관계에서 그릿과 사회적 지원의 조절효과를 규명하는 데 목적이 있다. 이를 위해 대구, 대전, 수원시의 콜센터 상담사 804명을 대상으로 설문을 실시하였으며 수집된 자료는 SPSS 25.0을 이용하여 분석하였다. 그 결과, 첫째, 고객상담사의 감정노동은 직무스트레스에 정적 영향을 미쳤다. 둘째, 고객상담사의 감정노동과 직무스트레스의 관계에서 그릿은 하위 요인에 따라 결과가 다르게 나타났다. 노력지속을 더 많이 할수록 직무스트레스는 증가하였고 흥미유지가 높을수록 직무스트레스는 감소하였다. 셋째, 고객상담사의 감정노동과 직무스트레스의 관계에서 사회적 지원의 상사지원은 조절효과가 확인된 반면 동료지원은 조절효과가 나타나지 않았다. 이 결과는 감정노동의 강도가 큰 고객상담사의 직무스트레스 예방에는 그릿 등 비인지적 요인과 믿을 수 있는 대상이 제공하는 지원을 통해 스스로 긍정적 인식을 갖게 돕는 개입이 필요함을 보여준다. 더불어, 이를 위한 적절한 중재 방법과 교육 환경 마련이 뒷받침되어야 하겠다.

머신러닝과 통계분석 기법의 비교분석을 통한 건물에 대한 서울시 구별 지진취약도 등급화 및 위험건물 밀도분석 (District-Level Seismic Vulnerability Rating and Risk Level Based-Density Analysis of Buildings through Comparative Analysis of Machine Learning and Statistical Analysis Techniques in Seoul)

  • 김상빈;김성훈;김대현
    • 산업융합연구
    • /
    • 제21권7호
    • /
    • pp.29-39
    • /
    • 2023
  • 최근 국내‧외적으로 많은 지진이 발생하고 있는 상황에서, 우리나라의 건물은 내진설계 및 지진피해에 매우 취약한 상황이다. 따라서 현 연구의 목적은 건물에 대한 지진취약도 등급화 및 위험건물 밀도분석을 수행하는 효과적인 방법을 발굴하고 이를 모델화하여, 시범지역(서울시)자료를 활용해 검증해 보는데 있다. 이를 위해 활용된 두 가지 모델링 기법 중, 통계 분석 기법의 예측정확도는 87%였고, 머신러닝 기법은 Random Forest모델의 예측정확도가 가장 높았으며, 해당 모델의 Test Set 정확도는 97.1%로 도출되었다. 분석결과, 구별 등급화 결과는 광진구와 송파구가 상대적으로 위험하다고 예측되었으며, 위험건물 밀도분석은 서초구, 관악구, 강서구가 상대적으로 위험하다고 예측되었다. 최종적으로, 통계분석 기법을 활용한 분석결과가 머신러닝 기법을 활용한 분석결과보다 위험하게 도출되었으나, 우리나라에서는 지진 강도 6.5(MMI)가 내진설계의 기준인데, 서울시 건물의 약 18.9%가 내진설계 되어있는 것으로 확인된 것을 고려하면, 머신러닝 기법의 결과가 더 정확할 것으로 예측되었다. 현 연구는 인구 및 인프라와 경찰서, 소방서 등을 고려 않은 오직 건물만을 고려한 한계점이 있으며, 해당 한계를 포함해 수행하면 더욱 포괄적인 연구가 될 것이다.

A Genetically Encoded Biosensor for the Detection of Levulinic Acid

  • Tae Hyun Kim;Seung-Gyun Woo;Seong Keun Kim;Byeong Hyeon Yoo;Jonghyeok Shin;Eugene Rha;Soo Jung Kim;Kil Koang Kwon;Hyewon Lee;Haseong Kim;Hee-Taek Kim;Bong-Hyun Sung;Seung-Goo Lee;Dae-Hee Lee
    • Journal of Microbiology and Biotechnology
    • /
    • 제33권4호
    • /
    • pp.552-558
    • /
    • 2023
  • Levulinic acid (LA) is a valuable chemical used in fuel additives, fragrances, and polymers. In this study, we proposed possible biosynthetic pathways for LA production from lignin and poly(ethylene terephthalate). We also created a genetically encoded biosensor responsive to LA, which can be used for screening and evolving the LA biosynthesis pathway genes, by employing an LvaR transcriptional regulator of Pseudomonas putida KT2440 to express a fluorescent reporter gene. The LvaR regulator senses LA as a cognate ligand. The LA biosensor was first examined in an Escherichia coli strain and was found to be non-functional. When the host of the LA biosensor was switched from E. coli to P. putida KT2440, the LA biosensor showed a linear correlation between fluorescence intensity and LA concentration in the range of 0.156-10 mM LA. In addition, we determined that 0.156 mM LA was the limit of LA detection in P. putida KT2440 harboring an LA-responsive biosensor. The maximal fluorescence increase was 12.3-fold in the presence of 10 mM LA compared to that in the absence of LA. The individual cell responses to LA concentrations reflected the population-averaged responses, which enabled high-throughput screening of enzymes and metabolic pathways involved in LA biosynthesis and sustainable production of LA in engineered microbes.

The effects of different metal posts, cements, and exposure parameters on cone-beam computed tomography artifacts

  • Ana Priscila Lira de Farias Freitas;Larissa Rangel Peixoto;Fernanda Clotilde Mariz Suassuna;Patricia Meira Bento;Ana Marly Araujo Maia Amorim;Karla Rovaris Silva;Renata Quirino de Almeida Barros;Andrea dos Anjos Pontual de Andrade Lima;Daniela Pita de Melo
    • Imaging Science in Dentistry
    • /
    • 제53권2호
    • /
    • pp.127-135
    • /
    • 2023
  • Purpose: This study assessed the intensity of artifacts produced by 2 metal posts, 2 cements, and different exposure parameters using 2 cone-beam computed tomography (CBCT) units. Materials and Methods: The sample was composed of 20 single-rooted premolars, divided into 4 groups: Ni-Cr/zinc phosphate, Ni-Cr/resin cement, Ag-Pd/zinc phosphate, and Ag-Pd/resin cement. Samples were scanned before and after post insertion and cementation using a CS9000 3D scanner with 4 exposure parameters (85/90 kV and 6.3/10 mA) and an i-CAT scanner with 120 kV and 5 mA. The presence of artifacts was assessed subjectively by 2 observers and objectively by a trained observer using ImageJ software. The Mann-Whitney, Wilcoxon, weighted kappa, and chi-square tests were used to assess data at a 95% confidence level(α<0.05). Results: In the subjective analyses, AgPd presented more hypodense and hyperdense lines than NiCr (P<0.05), and more hypodense halos were found using i-CAT (P<0.05) than using CS9000 3D. More hypodense halos, hypodense lines, and hyperdense lines were observed at 10 mA than at 6.3 mA (P<0.05). More hypodense halos were observed at 85 kV than at 90 kV (P<0.05). CS9000 3D presented more hypodense and hyperdense lines than i-CAT (P<0.05). In the objective analyses, AgPd presented higher percentages of hyperdense and hypodense artifacts than NiCr (P<0.05). Zinc phosphate cement presented higher hyperdense artifact percentages on CS9000 3D scans(P<0.05). CS9000 3D presented higher artifact percentages than i-CAT(P<0.05). Conclusion: High-atomic-number alloys, higher tube current, and lower tube voltage may increase the artifacts present in CBCT images.

붕어, 비둘기, 흰쥐의 肝臟의 Glutamic Dehydrogenase 및 Glutamic Transaminase 의 活性에 관한 比較 硏究 (A comparative Study on the Activities of Glutamic Dehydrogenase and Glutamic Transaminase in Livers of the Crucian carp, Pigeon, and Rat)

  • 김용규;남상열
    • 한국동물학회지
    • /
    • 제12권2호
    • /
    • pp.50-56
    • /
    • 1969
  • 붕어, 비둘기, 흰쥐의 肝組織內의 蛋白質含量과 蛋白質代謝에 관하여는 GDH, GOT 및 GPT의 活性과 比較活性, 그리고 GDH 同位酵素를 測定하였다. 1. 蛋白質含量은 흰쥐, 비둘기가 各各 22.0$\pm$0.01mg/ml 및 22.0$\pm$0.16으로서 거의 같은 量의 蛋白質含量으로 組成되었으나 붕어의 肝臟組織內 蛋白質含量은 約 60%에 該當하는 13.0$\pm$0.09이었다(p < 0.01). 2. Glutamic transaminase는 흰쥐, 비둘기, 붕어의 순위로 그 活性度가 낮았다. 卽 GPT의 比較活性은 各各 3.77$\pm$0.18 unit/mg, 1.93$\pm$0.01 및 0.71$\pm$0.07 이었으며 GOT는 8.23$\pm$0.06 unit/mg, 3.95$\pm$0.09 및 0.92$\pm$0.01이었다(p < 0.01). 3. GOT/GDT 比는 흰쥐, 비둘기, 붕어에서 各各 0.20$\pm$0.004, 0.22$\pm$0.005 및 0.20$\pm$0.002로서 별 차이 없었다. 4. GDH 比較活性은 비둘기가 가장 높은 35.7$\pm$0.81 unit/mg이고 붕어는 9.6$\pm$0.16, 흰쥐는 20.5$\pm$0.81이었다. 5. Glutamic transaminase 와 GDH 比較活性이 動物의 種類에 따라 병행하였으며 特히 進化過程과 一致되는 것으로 思料된다. 6. GDH 同位酵素의 樣相은 種特異性이 뚜렷하였다. 흰쥐에서는 음극이 遲延性易動度區劃의 活性이 가장 높았으나, 비둘기에서는 兩極性區劃의 活性이 가장 높았다. 特히 魚類에서는 陰極性區劃이 全然 發見되지 않았으나 兩極性에 4個의 區劃을 볼수 있었다.

  • PDF

간헐적인 걷기가 고령여성의 건강관련체력과 대사증후군 위험요인에 미치는 영향 (Effects of Intermittent Walking for Health Related Physical Fitness and Metabolic Syndrome Risk Factors in Elderly Women)

  • 김상훈
    • 한국노년학
    • /
    • 제29권4호
    • /
    • pp.1397-1411
    • /
    • 2009
  • 본 연구는 고령여성을 대상으로 간헐적인 걷기의 반복을 통해 신체활동량을 축적시켜 건강관련체력과 대사증후군 위험요인에 미치는 영향을 살펴보고자 시도하였다. 이를 위해 규칙적인 운동경험이 없는 65세 이상의 여성 자원자 총45명을 대상으로 간헐적 걷기집단, 지속적 걷기 집단, 통제집단의 세 집단으로 각각 15명씩 무작위 배정하였다. 간헐적 걷기집단은 매회 10분의 걷기를 4시간 간격으로 하루 3회 실시하고 지속적 걷기집단은 1일 1회 30분의 지속적인 걷기를 실시하였으며, 두 집단 모두 주 3회의 빈도로 12주간 실시하였다. 12주의 걷기 프로그램 종료 후 건강관련체력 측정결과 두 집단 모두 신체조성, 근지구력, 유연성, 전신지구력 항목에서 유의한 변화가 관찰되었으며, 근력에서는 지속적 걷기집단에서만 유의한 변화가 나타났다. 대사증후군 위험요인의 분석결과에서는 이완기혈압을 제외한 수축기혈압, 중성지방, 고밀도 지단백, 혈당에서 걷기를 실시한 두 집단 모두 긍정적인 개선효과가 나타났다. 결론적으로 매회 10분의 걷기를 하루 3회 실시하여 30분의 신체활동시간을 축적한 결과 30분간 지속적으로 걷기를 실시했을 때 나타나는 유산소 운동의 긍정적인 효과와 유사한 결과가 나타났으며, 체력수준이 약한 고령여성의 신체활동 증가를 위한 실용적이며 효율적인 운동방법으로 추천될 수 있을 것이다.

돼지의 성이 등심의 육질, 전자혀 측정치 및 관능적 맛 특성에 미치는 영향 (Influences of Gender on Meat Quality, Electronic Tongue Measurements and Sensory Characteristics of Pork Loin)

  • 이은영;이세진;황영화;강현정;주선태
    • 동물자원연구
    • /
    • 제30권4호
    • /
    • pp.165-171
    • /
    • 2019
  • 본 연구의 목적은 비육돈의 성이 육질과 맛 특성에 미치는 영향을 구명하는 것으로, 이를 위해 총 90두 삼원교잡 LYD 비육돈(180일령 암퇘지 45두와 거세돈 45두; 각 처리구당 1+, 1, 2등급 15마리씩 배치)의 육질, 기계적 맛 및 관능적 맛을 성별에 따라 조사하였다. 등심근의 pH, 근내지방 함량, 육색 및 전단가는 성별 간 차이가 없었지만(p>0.05), 암퇘지와 거세돈의 육즙감량(1.66% vs 1.21%), 유리수분량(12.19% vs 10.68%) 및 가열감량(23.67% vs 21.04%)에서는 유의적인 차이가 확인되었다(p<0.05). 전자혀 측정치는 거세돈의 신맛의 강도가 암퇘지보다 유의적으로 낮은 반면, 감칠맛과 감칠맛후미의 강도는 높았다(p<0.05). 관능검사에서는 풍미, 다즙성 및 연도에서 거세돈이 높은 점수를 받은 결과, 기호성에서도 거세돈(5.51점)이 암퇘지(4.86점)보다 유의적으로 높은 점수를 얻었다(p<0.05). 이러한 결과로부터, 암퇘지보다 높은 거세돈의 보수력이 감칠맛 강도를 증가시켜 관능적 맛도 좋게 한 것으로 사료되었다.

소아 청소년 물리치료 실태 조사: 서울 경기 지역 소아 청소년 재활병원을 중심으로 (Survey About Current Status of Pediatric and Adolescent Physical Therapy: Focus on Pediatric and Adolescent Rehabilitation Hospitals in Seoul and Gyeonggi Province)

  • 김정수;민경철
    • 재활치료과학
    • /
    • 제12권4호
    • /
    • pp.67-80
    • /
    • 2023
  • 목적 : 본 연구는 장애 소아 청소년을 치료 중인 물리치료사를 대상으로 소아 청소년 물리치료 실태, 만족도, 수가 체계, 대상, 시행, 평가 활용에 대해 알아보기 위해 진행되었다. 연구방법 : 서울 경기 지역 소아 청소년 물리치료사 60명을 대상으로 설문지를 활용하여 소아 청소년 물리치료 실태, 대상자, 만족도, 치료 시행 및 평가 활용 등을 조사하였다. 실태, 대상자, 만족도 등은 빈도 및 기초 통계 분석을 활용하여 분석하였으며, 물리치료 참여도-난이도, 소아 청소년 물리치료 주요 요소의 중요도-본인의 능력, 주요 치료 목표-사용 빈도 차이는 대응 표본 T 검정을 통하여 그 차이를 확인하였다. 결과 : 소아 청소년 물리치료 실태는 대부분 독립된 공간(95.0%)에서 하루 11~15건(66.7%), 1대 1 치료(95.0%)로 진행되는 것으로 조사되었다. 대상자의 주요 연령은 학령기, 학령전기, 진단은 뇌병변, 발달지연이 많았으며 20대 이상까지 치료하였다. 소아 청소년 물리치료 만족도는 높았으나(70.0%) 업무강도 역시 높았다(71.7%). 주요 치료법으로는 신경발달치료, 보행치료, 목표지향적 재활이 있으며, 평가는 대동작기능검사 88과 66, 대동작기능분류검사 사용이 많았다. 현 수가 체계는 부적합하다고 하였으며(66.1%), 적정 수가 체계가 필요하다고 하였다. 결론 : 본 연구를 통하여 소아 청소년 물리치료와 관련된 광범위한 내용과 요소를 확인하였다. 현 실태조사연구를 바탕으로 소아 청소년 물리치료사의 전문성 및 지속성 향상, 최신 치료법 적용을 위한 노력이 필요할 것이다.