• 제목/요약/키워드: High heat-load

검색결과 560건 처리시간 0.028초

나선형그루브-금망의 복합윅을 갖는 히이트파이프의 전열특성에 관한 연구 (A Study on the Characteristics of Heat Transfer in Heat Pipe with Composition Wick of Screwed Groove - Metallic Mesh)

  • 장영석;이영수;서정일
    • 대한설비공학회지:설비저널
    • /
    • 제15권3호
    • /
    • pp.273-282
    • /
    • 1986
  • The purpose of this research was to study the characteristics of heat transfer in Heat Pipe which used the composition wick of screened groove - metallic mesh by ADI method and experimental results. As the results, the more than number of metallic mesh screen layers in a heat pipe increased, the fewer the effect of heat recovery decreased. In case of 1 - layer metallic mesh screen wick, the response of the effect in heat recovery was more rapidly showed than in case of other layers and in spite of high load, the evaporation section of Heat pipe with 1 - layer metallic mesh screen wick showed the stable response and did not show excessive super heat. There was a interrelation between thermal resistance and the variable layers, between thermal resistance and the variable gaps of metallic meshes, the heat transfer characteristics of Heat pipe were depended on the thermal resistance of composition wick.

  • PDF

부하추종형 고효율 지열히트펌프 시스템에 관한 연구 (1) (A Study on the High Efficiency Ground Source Heat Pump System (1))

  • 고득용;김욱중;최상규;장기창
    • 신재생에너지
    • /
    • 제1권4호
    • /
    • pp.30-37
    • /
    • 2005
  • Cycle simulation of Ground Source Heat Pump[GSHP] system was carried out to determine the design specification of basic components such as turbo compressor and heat exchangers. Part load operation characteristics of the designed GSHP system was estimated using the compressor and heat exchanger performance data. A 50RT class turbo compressor for GSHP system is now under development, in which R134a refrigerant is adopted as working fluid. The compressor with variable cascade diffusers is designed to work both in cooling and heating modes so that it can actively keep up with the climate change with high efficiency. The normal running speeds of the compressor are 59000rpm for heating mode and 70000rpm for tooling mode respectively. It has two identical impellers at both ends of the rotor so as to minimize aero-induced thrust force effectively. GSHP system was coupled with a vortical type heat exchanger, and heat gain and heat loss from ground were evaluated per a bore hole. For the optimal integration of the heat pump system, its header for circulating fluid was combined with the ground heat exchangers in parallel and series configuration.

  • PDF

A Study on Thermal Load Management in a Deep Geological Repository for Efficient Disposal of High Level Radioactive Waste

  • Jongyoul Lee;Heuijoo Choi;Dongkeun Cho
    • 방사성폐기물학회지
    • /
    • 제20권4호
    • /
    • pp.469-488
    • /
    • 2022
  • Technology for high-level-waste disposal employing a multibarrier concept using engineered and natural barrier in stable bedrock at 300-1,000 m depth is being commercialized as a safe, long-term isolation method for high-level waste, including spent nuclear fuel. Managing heat generated from waste is important for improving disposal efficiency; thus, research on efficient heat management is required. In this study, thermal management methods to maximize disposal efficiency in terms of the disposal area required were developed. They efficiently use the land in an environment, such as Korea, where the land area is small and the amount of waste is large. The thermal effects of engineered barriers and natural barriers in a high-level waste disposal repository were analyzed. The research status of thermal management for the main bedrocks of the repository, such as crystalline, clay, salt, and other rocks, were reviewed. Based on a characteristics analysis of various heat management approaches, the spent nuclear fuel cooling time, buffer bentonite thermal conductivity, and disposal container size were chosen as efficient heat management methods applicable in Korea. For each method, thermal analyses of the disposal repository were performed. Based on the results, the disposal efficiency was evaluated preliminarily. Necessary future research is suggested.

주거용 건물의 개별 환기시스템 필요성에 관한 연구 (The Individual Heat-recovery ventilation system of Residential Buildings)

  • 신우철;이왕제;윤종호;백남춘
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.99-104
    • /
    • 2014
  • Recently supply of low energy house is increasing which can enhance energy efficiency and indoor environment comfort. Low energy house have to secure air tightness as well as thermal performance so house become high airtightness and inevitably need heat recovery ventilator to enhance indoor air quality. However, most of current ventilation systems are one-click, controlling the entire space so it causes increasing of heating load and fan power which makes it hard to save energy. Thus, Individual Control system is required which can achieve both enhancing indoor air quality and decreasing heating load and electric fan power. Thereby, in this study, we analyzed the correlation between ventilation and fan power through mock-up experiment and measured ventilation load under individual control system. As a result, under the condition of $24^{\circ}C$ of indoor temperature for 6 month(November to April) in Daejeon, ventilation load by fan speed was $10.9{\sim}19.6kWh/m^2{\cdot}a$ when operated 24 hours and $7.6{\sim}13.7kWh/m^2{\cdot}a$ when operated 12 hours in night time. In addition, it is possible to reduce at most 60% of ventilation load under the individual control system; measured ventilation load was $7.4kWh/m^2{\cdot}a$ when operated 24 hours, and $5.5kWh/m^2{\cdot}$ when operated 12 hours in night time.

대부하용 서보 구동 제어 시스템의 설계 (Design of servo driving control system for heavy load)

  • 이만형;이장명;윤강섭;최근국
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.504-509
    • /
    • 1993
  • A heavy load driving system for the gun laying control is designed with the analysis of performance in pointing accuracy and speed. To eliminate the firing noise and high frequency system noise, a .PI. filter is implemented in conjunction with the PI velocity control. To incorporate the gunner's commands in the PID position control loop easily, a .mu.-processor is utilized in the position control loop. Main difficulties in the heavy load driving system exist in the design of motor drivers and heat sinkers. With an appropriate design of the motor drivers and heat sinkers, the performance of the gun laying system is analyzed by the simulation.

  • PDF

옥상슬래브 단열조건에 따른 옥상녹화의 열환경 조정효과 (The Control of Temperature of Green Roof System with the Roof Slab Insulation Method)

  • 여인애;조홍제;윤성환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.869-872
    • /
    • 2008
  • On this study, the Control of Temperature is specified on the view of indoor comfort and building energy consumption. It is estimated by Dynamic heat load simulation which has the factors of insulation method and the soil thickness of the green roof system. The fact that the model which has no insulation has the greatest effect of dropping high temperature and the cooling load decrease is confirmed.

  • PDF

태양열 집열용 써모사이폰의 Geyser boiling에 대한 실험적 연구 (Experimental investigation of Geyser boiling in Thermosyphon for Solar Collector)

  • 홍정규;배찬효;정경택;서정세
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1040-1045
    • /
    • 2004
  • This study has been carried out to investigate thermosyphon's geyser boiling phenomenon used to solar collector. evaporator section of thermosyphon used to solar collector is very much longer than that of condenser section. From the results from this study, Geyser boiling's cycle depends on cooling water, tilt angle and the applied heat load at the evaporator. In this study, according to heat load, the geyser boiling frequency is lower, but the amplitude higher. For the high tilt angle of heat pipe, the frequency and amplitude are lower and higher in the evaporator region, respectively. Whereas, these phenomena is in contrast in the condenser region.

  • PDF

열렬화된 폴리에틸렌 케이블의 충격전압에 의한 파괴특성에 관한 연구 I (A Study on the Impulse Voltage Breakdown Characteristics of Heat-Deteriorated Polyethylene Cables ( I ))

  • 곽영순
    • 전기의세계
    • /
    • 제24권1호
    • /
    • pp.63-69
    • /
    • 1975
  • This study investigated the characteristics of fatigue breakdown caused by the impulse voltage of heat treated polyethylene cables through fault currents. This study attempted to obtain the badic data on the insulation design by the repeated load of impulse voltage wave zone (1*40.mu.s) on heat treated polyethylene cables. Besides this study also analysed the data involving their durability by means of the Weibull distribution. An analysis of the breakdown characteristics based upon the repeated load of impulse voltage has revealed that worn out deteriorative breakdown existed at a high voltage near the initial breakdown voltage, and that random breakdown was discovered at a voltage somewhat lower than the initial breakdown voltage. These phenomena were more remarkable especially in the case of the higher temperature treated cables.

  • PDF

예압에 따른 고주파 모터 내장형 주축의 열특성 해석 (Analysis on the Thermal Characteristics of the Spindle with High Frequency Motor according to the Preload)

  • 김수태;최대봉;정성훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.145-148
    • /
    • 2003
  • Thermal characteristics according to the bearing preload arc studied for the four type spindles with high frequency motor. For the analysis. three dimensional models are built considering heat transfer characteristics such as natural and forced convection coefficients, Bearing and motor are main heat generation, and heat generation by ball bearings as a function of load. viscosity and gyroscopic moment effect are considered. Unsteady-state temperature distributions and thermal displacements according to the bearing preload are analyzed by using the finite clement method.

  • PDF

태양열 반응로용 나트륨 히트파이프의 열이송 특성에 관한 실험적 연구 (An Experimental Study on the Heat Transport Characteristics of a Sodium Heat Pipe for a Solar Furnace)

  • 부준홍;박철민;김진수;강용혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.178-181
    • /
    • 2008
  • Cylindrical stainless-steel/sodium heat pipe for a high-temperature application was manufactured and tested for transient and steady-state operations. The container material was made of stainless-steel 316, and the working fluid was sodium. Stainless-steel 316 mesh screen was inserted as a capillary structure. The working fluid fill charge ratio was approximately 64 $\sim$ 181% based on the pore space of the wick. The outer diameter of the heat pipe was 12.7 mm and the total length was 250 mm. The evaporator part was 150 mm and the condenser 80 mm. The performance test of the heat pipe has been conducted in the furnace with up to 800 W. The variation of the average heat transfer coefficient was investigated as a function of heat flux and vapor temperature. As input thermal load increased, it was showed that difference of temperatures in evaporator and condenser decreased and that operating section and heat transfer characteristics at the heat pipe increased.

  • PDF