• 제목/요약/키워드: High frequency partial discharge (HFPD)

검색결과 18건 처리시간 0.022초

고주파 부분방전(HFPD)의 Pulse Analysis Map에 의한 GIS 결함 판별에 관한 연구 (A Study on the defect identification of GIS by Pulse Analysis Map(PA Map) using High Frequency Partial Discharge(HFPD) Detection)

  • 정현재;김지홍;김진기;고흥열;구자윤;김정태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.143-144
    • /
    • 2006
  • Since one decade. the detection of High frequency Partial Discharge has been proposed as one of the effective method for the diagnosis of the power component under service in power grids. As a tool for this detection. UHF sensor based on the antenna technology has been commercialized for mainly GIS due to its advantages. However, regarding the recognition of the vital defects introducible into the GIS. different types of softwares have been proposed and employed without any convincing probability of identification. In this regards, our work leads us to suggest a novel method named "PA Map" to identify the defects inside the GIS based on the HFPD detection by use of HFCT sensor which is designed according to our patent.

  • PDF

PA Map(Pulse Analysis Map)을 이용한 새로운 부분방전 패턴인식에 관한 연구 (A Study on the New Partial Discharge Pattern Analysis System used by PA Map (Pulse Analysis Map))

  • 김지홍;김정태;김진기;구자윤
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.1092-1098
    • /
    • 2007
  • Since one decade, the detection of HFPD (High frequency Partial Discharge) has been proposed as one of the effective method for the diagnosis of the power component under service in power grids. As a tool for HFPD detection, Metal Foil sensor based on the embedded technology has been commercialized for mainly power cable due to its advantages. Recently, for the on-site noise discrimination, several PA (Pulse analysis) methods have been reported and the related software, such as Neural Network and Fuzzy, have been proposed to separate the PD (Partial Discharge) signals from the noises since their wave shapes are completely different from each other. On the other hand, the relevant fundamental investigation has not yet clearly made while it is reported that the effectiveness of the current methods based on PA is dependant on the types of sensors. Moreover, regarding the identification of the vital defects introducible into the Power Cable, the direct identification of the nature of defects from the PD signals through Metal Foil coupler has not yet been realized. As a trial for solving above shortcomings, different types of software have been proposed and employed without any convincing probability of identification. In this regards, our novel algorithm 'PA Map' based on the pulse analysis is suggested to identify directly the defects inside the power cable from the HFPD signals which is output of the HFCT and metal foil sensors. This method enables to discriminate the noise and then to make the data analysis related to the PD signals. For the purpose, the HFPD detection and PA (Pulse Analysis) system have been developed and then the effect of noise discrimination has been investigated by use of the artificial defects using real scale mockup. Throughout these works, our system is proved to be capable of separating the small void discharges among the very large noises such as big air corona and ground floating discharges at the on-site as well as of identifying the concerned defects.

인위적인 결함을 이용한 기존의 저주파 부분방전과 고주파 부분방전의 패턴 비교 연구 (A comparison of the conventional LFPD and HFPD patterns by use of artificial)

  • 최재옥;이전선;임윤석;김정태;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1673-1675
    • /
    • 2001
  • In this paper, Partial Discharge(PD) patterns are compared by means of Low Frequency PD(LFPD, based on the IEC 270) and recently proposed High Frequency PD(HFPD). For this purpose, three different types of artificial defects are provided such as corona in air, void in epoxy insulator and needle defect in XLPE cable insulation. PD were generated from each defect and then detected respectively by two different methods such as LFPD and HFPD. As a result, remarkable resemblance in PD pattern for differ detecting method have been observed from each defect. Accordingly, it could be deduced that the pattern recognition by LFPD could be regarded as the reference for the investigations by HFPD.

  • PDF

HFPD 검출법을 이용한 지중 케이블 실선로 진단 (Diagnosis of power cable system based on the HFPD detection at on-site)

  • 이전선;김충식;이동근;공충호;석광현;이경욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.97-100
    • /
    • 2004
  • HFPD(High Frequency Partial Discharge) measurement has been widely performed to diagnosis of cable system in the world although Korea just begin. The efficiency of measurement has been reported and proved by many researchers who are engaged in the diagnosis of high power apparatus. LG Cable has investigated the technology of diagnosis for cable system by means of PD measurement for 10 years. In this paper, PD measurement with portable device was performed to evaluate the quality of the 154kV transmission line and the 22.9kV XLPE cable line. Test results are shown that the HFPD detection technology is very attractive for the diagnosis of power cable system by high detection sensitivity at on-site.

  • PDF

원자력발전소 전력케이블 부분방전 진단 사례 (Partial Discharge Measurement of Power Cables for Nuclear Power Plant)

  • 하체웅;주광호;임우상
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1632-1638
    • /
    • 2011
  • Electric cables are one of the most important components in a nuclear power plant since they provide the power needed to operate electrical equipment. Despite their importance, cables typically receive little attention since they are considered passive, long-lived components that have been very reliable over the years when subjected to the environmental conditions for which they were designed. The operating experience reveals that a defect of the insulator or poor construction causes the initial failure of cable. However, the number of cable failures increase with plant aging, and these cable failures are occurring within the plants' 40-year licensed period. These cable failures have resulted in plant transients, shutdown, loss of safety functions or redundancy, entries into limiting conditions for operation, and challenges for plant operators. Therefore, diagnosis of MV cable installed in NPPs has become one of the most urgent issues in recent years. In accordance with PSR, condition maintenance for cables is also continuously required. Recently, HFPD tests have been widely performed to diagnose cable in the transmission and distribution cable system. However, on-line HFPD wasn't used in the NPPs because of the danger of plant shutdown, measurement sensitivity and application problems, etc. In this paper, HFPD measurement with portable device was performed to evaluate the integrity of the 4.16kV & 13.8kV cable lines. The test results show that HFPD is highly attractive to the diagnosis of MV cables in NPP by high detection sensitivity on-site.

3d-PD의 통계적 고찰과 신경망 응용기술 (The Application Technique on AI and Statistical Analysis of 3d-PD)

  • 임장섭;박용식;최병하;한석균
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 센서 박막재료
    • /
    • pp.66-70
    • /
    • 2001
  • The partial discharge testing is widely used in diagnostic measuring technology because it gives low stress to power equipment which is undertaken tests. Therefore it is very useful method compare to previous destructive methods and effective diagnosis method in power system that requires on-line/on-site diagnosis. But partial discharges have very complex characteristics of discharge pattern, so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated system is manufactured and HFPD occurred from those simulator is measured with broad-band antenna in real time, the degradation grade of system is analyzed through produced patterns in simulated target according to the AI/statistics processing.

  • PDF

고주파 부분방전(HFPD)측정용 하이브리드 센서 개발에 관한 연구 (A development of the Hybrid Sensor for the detection of the High Frequency Partial Discharge(HFPD))

  • 김지홍;구자윤;김정태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.173-175
    • /
    • 2002
  • In general, CT and Shunt have been traditionally used as a sensor for detecting the partial discharges in order to diagnose the present insulation state of the electric power apparatus. The former is very convenient for the practical application since it is not only non-contact method but its frequency bandwidth and resonance frequency could be designed for its specific application. However, it has been proved to have poor linearity and low sensitivity. For the latter, even though it is an ideal sensor, noise from the power source and the ground could flow into the system. Furthermore, the surge current could be easily come into the measuring systems giving rise to a severe breakdown. In this respect, a hybrid sensor has been designed and fabricated in order to overcome the shortcoming of these two types of sensors. For this purpose, the experimental comparison with commercialized products has been also carried out. In this concept of the hybrid sensor, two different impedances could provide the passage of the signals. In this way, the discrimination of the noise could be accomplished very effectively with high ratio of signal over noise(S/N) under the little influence from the external noises and the breakdown.

  • PDF

154kV XLPE 케이블 실선로 부분방전 검출 (Partial Discharge Measurement for 154kV XLPE Cable Line)

  • 김충식;이전선;김종철;박창기;석광현;김원년
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.23-25
    • /
    • 2004
  • HFPD(High Frequency Partial Discharge) measurement has been widely performed to diagnose cable system in the world. Shin-Yeongdeungpo 345kV XLPE line was successfully diagnosed by PD measurement methode last year. Moreover, aged power cable lines which were installed 15 years ago have been tested from this year. In this paper, the result of PD diagnosis for aged 154kV cable line is reported. The PD pattern from TMJ which was monitored by PD measurement system for several days showed typical void pattern. The joint was replaced and voids between semi-conductor layer and insulating layer in the joint was founded.

  • PDF