A comparison of the conventional LFPD and HFPD patterns by use of artificial

인위적인 결함을 이용한 기존의 저주파 부분방전과 고주파 부분방전의 패턴 비교 연구

  • 최재옥 (한양대학교 전기공학과 (EM & C)) ;
  • 이전선 (한양대학교 전기공학과 (EM & C)) ;
  • 임윤석 (한양대학교 전기공학과 (EM & C)) ;
  • 김정태 (대진대학교 전기공학과) ;
  • 구자윤 (한양대학교 전기공학과 (EM & C))
  • Published : 2001.07.18

Abstract

In this paper, Partial Discharge(PD) patterns are compared by means of Low Frequency PD(LFPD, based on the IEC 270) and recently proposed High Frequency PD(HFPD). For this purpose, three different types of artificial defects are provided such as corona in air, void in epoxy insulator and needle defect in XLPE cable insulation. PD were generated from each defect and then detected respectively by two different methods such as LFPD and HFPD. As a result, remarkable resemblance in PD pattern for differ detecting method have been observed from each defect. Accordingly, it could be deduced that the pattern recognition by LFPD could be regarded as the reference for the investigations by HFPD.

Keywords