• Title/Summary/Keyword: High frequency cavity

검색결과 172건 처리시간 0.021초

우백혈병의 임상 및 세포형태학적 연구 (Clinical and Cytomorphological Studios on Bovine Leukosis)

  • 김덕환
    • 한국임상수의학회지
    • /
    • 제2권1호
    • /
    • pp.79-104
    • /
    • 1985
  • Clinical and cytomorphological studies were carried out in 32 leukotic cattle from Tokachi and Kushiro districts in Hokkaido during the 12 year period from 1969 to 1980. The leukotic cattle were examined :and divided into four types(15 cases of the adult, 11 cases of the thymic, 4 casas of the calf and 2 cases of the skin types). The results obtained were as follows : 1. As for the frequency of the main clinical signs in each type, In the adult type, the main clinical signs (of decreasing order) are as follows: swelling of the superficial lymph nodes>depression and loss of weight>tachycardia>anorekia, anemia of the visible mucous membrane and tachypnea. Those of the thymic type were swelling of the thymus>swelling of the medial iliac lymph nodes> swelling of the superficial lymph nodes>tachypnea. Those of the calf type were swelling of the auperficial lymph nodes>depression and emaciation>tachypnea>anorexia, tachycardia, anemia of the visible mucous membrane and recumbency. Those of the skin type were generalized urticaria-like lesions in skin and swelling of superficial lymph nodes>and depression and loss of weight in the decreasing order of frequency. In addition, large tumor mass in the pelvic cavity and swelling of the medial iliac lymph nodes were detected through rectal palpation in 33.3% and 100% in the adult type cases, respectively. 2. As for the hematological findings, The frequency of occurrence of decreased erythrocyte counts in the decreasing order were as follows : adult>calf>thymic>and skin types. The increase in the total leukocyte count in the order of decreasing frequency were as follows: calf>thymic>adult>and skin types. The increase in the absolute lymphocyte counts was found to be at a low rate, 62.5% of all the cases examined. By contrast, the increase of 5% or more of abnormal lymphocyte rates was observed at a high rate, 96.9% of the total cases. 3. Abnormal lymphocytes were found in all cases examined for lymph nodes biopsied. 4. From the cytomorphological point of view, leukotic cells were divided into 3 types: reticulum cell, lymphoid cell and monocytic cell types. The adult type leukotic cattle were divided with reticulum cell type (66.7%), the lymphoid cell type(22.6%) and monocytic cell type(6.7%). The thymic type was lymphoip cell type(72.7%) and reticulum cell type(27.3%). In the calf type, all were lymphoid cell type while all of the skin type were reticulum cell type only. 5. The leukotic cattle had higher NP frequency in the blood and lymphoid tissue than non-1 eukotic cattle. Especially the adult type had the highest NP frequency. However, it was not recognized that NP were characteristic of leukotic cattle alone. 6. The above findings lead to the conclusion that the most effective diagnostic methods for bovine leukosis are the confirmation of swelling of the superficial and internal lymph nodes and thymus in addition to appearance of abnormal neoplastic cell in the peripheral blood and lymph nodes biopsied.

  • PDF

3중 접합 공정에 의한 MEMS 공진기의 웨이퍼레벨 진공 패키징 (Wafer-level Vacuum Packaging of a MEMS Resonator using the Three-layer Bonding Technique)

  • 양충모;김희연;박종철;나예은;김태현;노길선;심갑섭;김기훈
    • 센서학회지
    • /
    • 제29권5호
    • /
    • pp.354-359
    • /
    • 2020
  • The high vacuum hermetic sealing technique ensures excellent performance of MEMS resonators. For the high vacuum hermetic sealing, the customization of anodic bonding equipment was conducted for the glass/Si/glass triple-stack anodic bonding process. Figure 1 presents the schematic of the MEMS resonator with triple-stack high-vacuum anodic bonding. The anodic bonding process for vacuum sealing was performed with the chamber pressure lower than 5 × 10-6 mbar, the piston pressure of 5 kN, and the applied voltage was 1 kV. The process temperature during anodic bonding was 400 ℃. To maintain the vacuum condition of the glass cavity, a getter material, such as a titanium thin film, was deposited. The getter materials was active at the 400 ℃ during the anodic bonding process. To read out the electrical signals from the Si resonator, a vertical feed-through was applied by using through glass via (TGV) which is formed by sandblasting technique of cap glass wafer. The aluminum electrodes was conformally deposited on the via-hole structure of cap glass. The TGV process provides reliable electrical interconnection between Si resonator and aluminum electrodes on the cap glass without leakage or electrical disconnection through the TGV. The fabricated MEMS resonator with proposed vacuum packaging using three-layer anodic bonding process has resonance frequency and quality factor of about 16 kHz and more than 40,000, respectively.

치아 와동의 복합레진 수복시 음향방출의 시간적 발생 특성 (Time-Based Characteristics of Acoustic Emission During Dental Composite Restoration)

  • 구자국;최낙삼
    • 대한기계학회논문집A
    • /
    • 제35권2호
    • /
    • pp.169-174
    • /
    • 2011
  • 제 1 급 와동이 모사된 비관통형 치아 시편에 수복된 복합레진의 중합 수축시 발생하는 AE 신호를 실시간으로 검출한 후 이를 분석하였다. 시간대별 발생 분포를 살펴보면, 광조사 초기에 중합 수축이 급격히 진행되는 제 I 구간에서 AE event 가 많이 관찰되었다. 제 I구간 후 AE event 발생 빈도가 낮아져 AE 가 별로 관찰되지 않은 제II구간이 있었는데, AE 신호의 발생이 적은 PMMA 는 치아에 비해 구간이 길었으며 AE 검출이 잦았던 스테인리스스틸 모형은 제 II 구간이 짧았다. AE 활성도를 나타내는 구간 특성은 수복재와 와동의 계면부에서 일어나는 균열의 발생빈도를 나타내는 것으로 사료되며 젤화점 직후의 제I 구간에서 AE 가 집중적으로 관측되는 바, 수복재와 와동 사이의 갭 형성은 바로 젤화점 직후에 만들어졌음을 가리킨다. 신호의 최대 진폭은 25-45dB 이었고 1 차 중심 주파수는 100-200kHz 와 240-400kHz 영역의 신호들이 발생하였으며 이는 레진이나 접착층의 파괴에 해당하였다.

Applying Fire Risk Analysis to Develop Fire-safe Modular Walls: Guidance to Material Selection, Design Approach and Construction Method

  • Lim, Seokho;Chung, Joonsoo;Kim, Mihyun Esther
    • Architectural research
    • /
    • 제24권2호
    • /
    • pp.21-27
    • /
    • 2022
  • For the past decade, South Korea had experienced catastrophic building fires, which resulted in consider-ably high number of casualties. This motivated research to develop fire-safe wall assemblies. In this study Fire Risk Analysis (FRA) is conducted as part of the project designing phase to ensure fire safety of the final product. Traditional approach was to consider fire performance at the end of the designing stage, when PASS/FAIL fire test results are required to be submitted to the Authority Having Jurisdiction (AHJ). By applying a fire risk analysis to guide the designing phase, overall fire safety of a wall assembly can be achieved more systematically as conducting FRA allows designers to clearly identify elements that are more vulnerable to fire and simply replace them with other practical options. Severity of fire risk is determined by considering the fire hazards of a wall assembly such as the exterior layer, insulation, vertical connectivity, and external ignition sources (e.g., photovoltaic panels). Frequency of fire risk is assessed based on the factors affecting fire likelihood, which are air cavity and fire-stopping applied in the design, and random design changes occurring during on-site construction. Fire risk matrix is proposed based on these fire risk factors and efforts to reduce the fire risk level associated with the wall assembly are given by systematically assessing the fire risk factors identified from fire risk analysis. Current study demonstrates how fire risk analysis can be applied to develop fire-safe walls by reducing the relevant fire risks- both severity and frequency.

Improvement of Fat Suppression and Artifact Reduction Using IDEAL Technique in Head and Neck MRI at 3T

  • Hong, Jin Ho;Lee, Ha Young;Kang, Young Hye;Lim, Myung Kwan;Kim, Yeo Ju;Cho, Soon Gu;Kim, Mi Young
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권1호
    • /
    • pp.44-52
    • /
    • 2016
  • Purpose: To quantitatively and qualitatively compare fat-suppressed MRI quality using iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) with that using frequency selective fat-suppression (FSFS) T2- and postcontrast T1-weighted fast spin-echo images of the head and neck at 3T. Materials and Methods: The study was approved by our Institutional Review Board. Prospective MR image analysis was performed in 36 individuals at a single-center. Axial fat suppressed T2- and postcontrast T1-weighted images with IDEAL and FSFS were compared. Visual assessment was performed by two independent readers with respect to; 1) metallic artifacts around oral cavity, 2) susceptibility artifacts around upper airway, paranasal sinus, and head-neck junction, 3) homogeneity of fat suppression, 4) image sharpness, 5) tissue contrast of pathologies and lymph nodes. The signal-to-noise ratios (SNR) for each image sequence were assessed. Results: Both IDEAL fat suppressed T2- and T1-weighted images significantly reduced artifacts around airway, paranasal sinus, and head-neck junction, and significantly improved homogeneous fat suppression in compared to those using FSFS (P < 0.05 for all). IDEAL significantly decreased artifacts around oral cavity on T2-weighted images (P < 0.05, respectively) and improved sharpness, lesion-to-tissue, and lymph node-to-tissue contrast on T1-weighted images (P < 0.05 for all). The mean SNRs were significantly improved on both T1- and T2-weighted IDEAL images (P < 0.05 for all). Conclusion: IDEAL technique improves image quality in the head and neck by reducing artifacts with homogeneous fat suppression, while maintaining a high SNR.

비파괴 측정을 위한 근접장 마이크로파 현미경 연구 (The Study of Near-field Scanning Microwave Microscope for the Nondestructive Detection System)

  • 김주영;김송희;유현준;양종일;유형근;유경선;김승완;이기진
    • 비파괴검사학회지
    • /
    • 제24권5호
    • /
    • pp.508-517
    • /
    • 2004
  • 근접장의 특성과 근접장 마이크로파 현미경의 배경이론을 설명하였고 유전체 공진기 제작에 앞서 HFSS (high frequency structure simulator)를 이용한 모의 시뮬레이션을 기술하였다. 이것을 바탕으로 원통형 유전체 공진기를 제작하여 금속탐침과 결합한 근접장 마이크로파 현미경(near field scanning microwave microscope : NSMM)을 구성하였다. 제작한 유전체 공진기의 특성은 HFSS를 이용하여 모의 실험한 결과와 비교하였다 Tip의 기하학적 모양에 따른 공간분해능과 감도(sensitivity)를 연구하였고 contrast가 가장 좋은 hybrid tip을 개발하였다. 전도도가 서로 다른 금속시료에 따른 NSMM의 반사계수의 변화를 측정하였고 실험결과와 이론적 시료의 임피던스를 비교하였다. 마지막으로 유전체 공진기를 이용한 NSMM으로 공간 분해능이 $1{\mu}m$의 Cr과 NiFe 패턴의 이미지를 비접촉, 비파괴방법으로 얻었다.

시멘트 취급 근로자들에 대한 구강위생실태 연구 (A Study on the Occupational Diseases and Dental Hygiene of Laborers in Cement Industry)

  • 박일순;정미애;한지형
    • 한국치위생학회지
    • /
    • 제2권1호
    • /
    • pp.115-129
    • /
    • 2002
  • The purpose of this study was to examine the actual dental hygiene status of workers in cement industry in an effort to serve as a basis for enhancing their dental hygiene. The subjects in this study were 420 laborers from the cities of Curi, Donghae and Samcheok who handled cement. As a result of conducting a survey, the following findings were given : l. The workers investigated found their working environment satisfactory, getting a mean score of 323. They also expressed a high job satisfaction with a mean score of 333. 2. They didn't have a big interest in oral health. By age group, those who were aged between 36 and 40, or who cared less about health management, showed a higher interest in oral health. Besides, the laborers who kept smoking for a longer period, or who drunk more, expressed greater interest. 3. The toothbrushing method was considered most important for periodontal health, by 45.0% of the workers, and the next most crucial one was regular dental examination, followed by refraining from smoking and staying away from sweet food in the order named. 4. Concerning daily mean toothbrushing frequency, 455% brushed their teeth three times a day on the average. More than half them didn't pay enough attention to toothbrushing. 5. Regarding scaling, the large number of the workers, 42.4%, had no experience to get their teeth scaled, 37.6%, the greatest percentage, didn't have their teeth scaled because it seemed to make their teeth painful or cold. 6. As fororal health education experience, 67.6%, the great number of them, had no experience to receive dental health education. The above-mentioned findings suggest that the cement-related workers generally neglected dental health management. They should be encouraged to correct their wrong oral health knowledge or habit to make their oral cavity more healthy. To make it happen, it's required to provide oral health education and promote organized dental health projects.

  • PDF

무선통신용 초소형 대역통과 필터의 설계 (Design of the Small BPF for Wireless Communication Systems)

  • 황재호
    • 조명전기설비학회논문지
    • /
    • 제19권7호
    • /
    • pp.26-31
    • /
    • 2005
  • 본 논문은 무선통신 시스템에 사용되는 저 손실 소형 대역통과 필터를 새로운 프로브 구조를 적용하여 설계 제작하였다. 필터의 저 손실 특성을 위해 Q값이 높은 Ba(Co, Nb)$O_3$계 세라믹 유전체 공진기를 사용하였으며, $TE_{01{\delta}}$ 모드의 공진을 이용하여 금속 캐비티의 도체손실 영향을 줄였다. 소형화를 구현하는 방법으로는 캐비티의 양옆의 공간을 줄이도록 정사각형 캐비티의 코너 공간을 적극 활용하였으며, $12{\times}12{\times}8[mm]$의 초소형 필터를 제작하였다. 제작된 소형 필터의 주파수특성을 측정한 결과, 중심주파수 $f_0$는 9.95358[GHz], 삽입손실은 -1.9[dB], 3[dB]_대역폭은 14.9[MHz], 부하Q는 664로 저손실 대역동과 필터의 특성을 만족하고 있다.

공조용 로터리 압축기 소음저감을 위한 어큐뮬레이터 최적설계 (Design Optimization of an Accumulator for Noise Reduction of Rotary Compressor)

  • 이의윤;김봉준;이정배;성춘모;이운섭;이종수
    • 대한기계학회논문집A
    • /
    • 제35권7호
    • /
    • pp.759-766
    • /
    • 2011
  • 최근 가정용 에어컨은 냉방효율뿐 아니라 소음에 대한 중요성이 지속적으로 높아지고 있다. 로터리 압축기는 에어컨의 소음 중 매우 높은 영향도를 가지고 있으며, 압축기의 소음을 줄이기 위해 머플러 및 공명기에 관한 많은 연구들이 진행되어 왔다. 압축기의 부품 중 어큐뮬레이터는 큰 용적으로 인해 공명에 의한 추가 소음을 에어컨에 전달하는 소음 전달경로가 되며, 어큐뮬레이터의 내부구조는 소음저감을 위해 중요한 설계요소가 되나 지금까지는 연구결과가 미비한 수준이었다. 본 논문에서는 어큐뮬레이터의 소음 저감을 위해 목표주파수 대역에서의 투과손실이 최대가 되는 설계최적화를 수행하였다. 높은 비선형성을 가진 문제의 최적화를 위해 실험계획법과 반경기저신경망기법을 이용한 근사 모델을 사용하였으며, 유전알고리즘을 사용한 최적화를 수행하였다.

시분할 센싱 기법 기반의 출력 안정화를 위한 10 Gb/s 4채널 VCSELs 드라이버의 구현 (Implementation of 10 Gb/s 4-Channel VCSELs Driver Chip for Output Stabilization Based on Time Division Sensing Method)

  • 양충열;이강윤;이상수;정환석
    • 한국통신학회논문지
    • /
    • 제40권7호
    • /
    • pp.1347-1353
    • /
    • 2015
  • $0.13-{\mu}m$ CMOS 공정기술을 이용하여 10 Gb/s 4채널 수직공진 표면 광레이저 (VCSEL) 드라이버 어레이를 구현하였다. 높은 전류 해상도, 전력 소모 및 칩 면적의 향상을 위해 시분할 센싱기법을 사용한 디지털 APC/AMC가 최초로 채택되었다. 측정된 -3 dB 주파수 대역폭은 9.2 GHz이고, 소신호 이득은 10.5 dB, 그리고 전류 해상도는 폭넓은 온도 범위에 대해 10 Gb/s 까지 안정한 파장동작을 위한 1 mA/step이다. 제안된 APC/AMC는 5 ~ 20 mA 의 바이어스 전류 제어 및 5 ~ 20 mA 의 변조전류제어를 입증하였다. 4 채널 칩 소모전력은 최대 바이어스 및 변조전류 하에서 371 mW, 칩 사이즈는 $3.71{\times}1.3mm^2$이다.