• 제목/요약/키워드: High energy X-ray

검색결과 1,151건 처리시간 0.035초

Development of Diode Based High Energy X-ray Spatial Dose Distribution Measuring Device

  • Lee, Jeonghee;Kim, Ikhyun;Park, Jong-Won;Lim, Yong-Kon;Moon, Myungkook;Lee, Sangheon;Lim, Chang Hwy
    • Journal of Radiation Protection and Research
    • /
    • 제43권3호
    • /
    • pp.97-106
    • /
    • 2018
  • Background: A cargo container scanner using a high-energy X-ray generates a fan beam X-ray to acquire a transmitted image. Because the generated X-rays by LINAC may affect the image quality and radiation protection of the system, it is necessary to acquire accurate information about the generated X-ray beam distribution. In this paper, a diode-based multi-channel spatial dose measuring device for measuring the X-ray dose distribution developed for measuring the high energy X-ray beam distribution of the container scanner is described. Materials and Methods: The developed high-energy X-ray spatial dose distribution measuring device can measure the spatial distribution of X-rays using 128 diode-based X-ray sensors. And precise measurement of the beam distribution is possible through automatic positioning in the vertical and horizontal directions. The response characteristics of the measurement system were evaluated by comparing the signal gain difference of each pixel, response linearity according to X-ray incident dose change, evaluation of resolution, and measurement of two-dimensional spatial beam distribution. Results and Discussion: As a result, it was found that the difference between the maximum value and the minimum value of the response signal according to the incident position showed a difference of about 10%, and the response signal was linearly increased. And it has been confirmed that high-resolution and two-dimensional measurements are possible. Conclusion: The developed X-ray spatial dose measuring device was evaluated as suitable for dose measurement of high energy X-ray through confirmation of linearity of response signal, spatial uniformity, high resolution measuring ability and ability to measure spatial dose. We will perform precise measurement of the X-ray beamline in the container scanning system using the X-ray spatial dose distribution measuring device developed through this research.

Energy Spectrum Measurement of High Power and High Energy (6 and 9 MeV) Pulsed X-ray Source for Industrial Use

  • Takagi, Hiroyuki;Murata, Isao
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.93-99
    • /
    • 2016
  • Background: Industrial X-ray CT system is normally applied to non-destructive testing (NDT) for industrial product made from metal. Furthermore there are some special CT systems, which have an ability to inspect nuclear fuel assemblies or rocket motors, using high power and high energy (more than 6 MeV) pulsed X-ray source. In these case, pulsed X-ray are produced by the electron linear accelerator, and a huge number of photons with a wide energy spectrum are produced within a very short period. Consequently, it is difficult to measure the X-ray energy spectrum for such accelerator-based X-ray sources using simple spectrometry. Due to this difficulty, unexpected images and artifacts which lead to incorrect density information and dimensions of specimens cannot be avoided in CT images. For getting highly precise CT images, it is important to know the precise energy spectrum of emitted X-rays. Materials and Methods: In order to realize it we investigated a new approach utilizing the Bayesian estimation method combined with an attenuation curve measurement using step shaped attenuation material. This method was validated by precise measurement of energy spectrum from a 1 MeV electron accelerator. In this study, to extend the applicable X-ray energy range we tried to measure energy spectra of X-ray sources from 6 and 9 MeV linear accelerators by using the recently developed method. Results and Discussion: In this study, an attenuation curves are measured by using a step-shaped attenuation materials of aluminum and steel individually, and the each X-ray spectrum is reconstructed from the measured attenuation curve by the spectrum type Bayesian estimation method. Conclusion: The obtained result shows good agreement with simulated spectra, and the presently developed technique is adaptable for high energy X-ray source more than 6 MeV.

EDLC를 이용한 X선 투시촬영장치용 하이브리드 X선 제너레이터 (Hybrid Type X-Ray Generator Using EDLC for Fluoroscopy X-Ray System)

  • 서영민;홍순찬
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.89-98
    • /
    • 2014
  • A diagnostic fluoroscopy X-ray system uses a 32kW or greater X-ray generator for obtaining real-time moving images and high-resolution images. Fluoroscopy X-ray systems have to use a high-capacity AC power source to perform long-time low-power fluoroscopy and short-time high-power spot exposure. In this paper, we propose a hybrid type X-ray generator for fluoroscopy X-ray system which can perform fluoroscopy and spot exposure with a low-capacity AC power source and an energy storage device. The characteristics of energy storage devices are compared and each energy storage device is modelled to equivalent circuit. And the characteristics of available energy are analyzed as a function of output voltage and power. A 32kW class hybrid X-ray generator with EDLC as an energy storage device for fluoroscopy X-ray system was constructed, and its validity was verified by means of simulations and experiments.

이중 에너지 검출기를 이용한 영상 시스템 (Image System Using Dual Energy Detector)

  • 여화연
    • 한국산학기술학회논문지
    • /
    • 제11권9호
    • /
    • pp.3517-3523
    • /
    • 2010
  • 본 논문은 이중 에너지 DR(Digital Radiography) 방식 중, 단일 조사 X-선(single shot X-ray exposure) 장치와 이중 모드 검출기 모듈 (Low Energy Detector & High Energy Detector)을 이용한 이중 X-선 이미징이 가능한 검출기 모듈에 관한 연구이다. 상용 BIS(baggage inspection system)에서 사용되고 있는 X-선 발생장치의 스펙트럼과 이중 모드 검출기에 대한 특징 및 방사선적 특성을 분석하여 새롭게 제안 할 검출기 모듈의 최적 설계 방향을 기술하고 상용화된 용화된 LED 및 HED 검출기와 새롭게 제안 한 검출기 모듈에 대해 전기적, 광학적, 방사선적 특성 실험을 실시하여, 새롭게 제안된 검출기 모듈이 BIS 용도로 사용 가능함을 증명하였다. 새롭게 제안 된 검출기 모듈이 적용된 BIS에 대해, 기본 특성 실험에 대한 X-선 영상을 획득하여 실험 및 분석을 실시하였다.

System Design and Evaluation of a Compact and High Energy X-ray Talbot-Lau Grating Interferometer for Industrial Applications

  • Lee, Seho;Oh, Ohsung;Kim, Youngju;Lee, Seung Wook;Kim, Insoo;Kim, Jinkyu
    • Journal of the Korean Physical Society
    • /
    • 제73권12호
    • /
    • pp.1827-1833
    • /
    • 2018
  • X-ray grating interferometry has been an active area of research in recent years. In particular, various studies have been carried out for the practical use of the x-ray grating interferometer in medical and industrial fields. For the commercialization of the system, it needs to be optimized for its application. In this study, we have developed a prototype of the compact high energy x-ray grating interferometer of which the high effective energy and compactness is of our primary feature of design. We have designed the Talbot-Lau x-ray interferometer in a symmetrical geometry with an effective energy of 54.3 keV. The system has a source-to-analyzer grating distance of 788.4 mm, which is compact enough for a commercial product. In a normal operation, it took less than ten seconds to acquire a set of phase stepping images. The acquired images had a maximum visibility of about 15%, which is relatively high compared with the visibilities of the other high-energy grating interferometric systems reported so far.

PCB 비파괴 검사에 있어서 단일 에너지 소스와 이중 에너지 소스의 영상비교를 위한 엑스선 스펙트럼 분석 (Energy Spectrum Analysis between Single and Dual Energy Source X-ray Imaging for PCB Non-destructive Test)

  • 김명수;김기윤;이민주;강동욱;이대희;박경진;김예원;김찬규;김형택;조규성
    • 방사선산업학회지
    • /
    • 제9권3호
    • /
    • pp.153-159
    • /
    • 2015
  • Reliability of printed circuit board (PCB), which is based on high integrated circuit technology, is having been important because of development of electric and self-driving car. In order to answer these demand, automated X-ray inspection (AXI) is best solution for PCB non-destructive test. PCB is consist of plastic, copper, and, lead, which have low to high Z-number materials. By using dual energy X-ray imaging, these materials can be inspected accurately and efficiently. Dual energy X-ray imaging, that have the advantage of separating materials, however, need some solution such as energy separation method and enhancing efficiency because PCB has materials that has wide range of Z-number. In this work, we found out several things by analysis of X-ray energy spectrum. Separating between lead and combination of plastic and copper is only possible with energy range not dose. On the other hand, separating between plastic and copper is only with dose not energy range. Moreover the copper filter of high energy part of dual X-ray imaging and 50 kVp of low energy part of dual X-ray imaging is best for efficiency.

방사광 X-선을 이용한 리튬이온전지 소재의 실시간 구조 분석 연구 (In situ Synchrotron X-ray Techniques for Structural Investigation of Electrode Materials for Li-ion Battery)

  • 한다슬;남경완
    • 세라미스트
    • /
    • 제22권4호
    • /
    • pp.402-416
    • /
    • 2019
  • The development of next-generation secondary batteries, including lithium-ion batteries (LIB), requires performance enhancements such as high energy/high power density, low cost, long life, and excellent safety. The discovery of new materials with such requirements is a challenging and time-consuming process with great difficulty. To pursue this challenging endeavor, it is pivotal to understand the structure and interface of electrode materials in a multiscale level at the atomic, molecular, macro-scale during charging / discharging. In this regard, various advanced material characterization tools, including the first-principle calculation, high-resolution electron microscopy, and synchrotron-based X-ray techniques, have been actively employed to understand the charge storage- and degradation-mechanisms of various electrode materials. In this article, we introduce and review recent advances in in-situ synchrotron-based x-ray techniques to study electrode materials for LIBs during thermal degradation and charging/discharging. We show that the fundamental understanding of the structure and interface of the battery materials gained through these advanced in-situ investigations provides valuable insight into designing next-generation electrode materials with significantly improved performance in terms of high energy/high power density, low cost, long life, and excellent safety.

NON-DESTRUCTIVE DETECTION FOR FOREIGN MATERIALS IN FOOD AND AGRICULTURAL PRODUCTS USING X-RAY SYSTEM

  • Morita, Kazuo;Tanaka, Shun'ichirou;Ogawa, Yukiharu
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.334-343
    • /
    • 1996
  • Quality evaluation for food and agricultural products have always been one of the most elusive problems associated with the handling , processing and marketing in a food plant production. In order to detect physical foreign materials in food and agricultural products, non-destructive techniques have been developed for many years. Application of X-ray system to detect physical foreign materials in food and agricultural products could be considered to be a high potential method. Especially , it is impossible to detect internal physical foreign materials by visual inspections. In this study, it was tried to be applied for two different X-ray devices. Soft X-ray system with CdTe sensor and X-ray CT scanner were evaluated for advantage of the detection of non-meltallic foreign materials in food and agricultural products . Though the soft X-ray is not a high energy radiation, it is possible to detect small different density in a material. The CdTe sensor has a high resolution for t e soft X-ray energy region. The density characteristics of foods and foreign material were expressed region. The density characteristics of foods and foreign materials were expressed as a soft X-ray energy spectrum. The energy spectrum was analyzed by a personal computer with a multi-channel analyzer. X-ray CT scanner can provide visual image and analyze by three dimensional information inside food and agricultural products. The X-ray CT scanner using as a medical equipment was used to detect a foreign material. The density characteristics of food and foreign materials in food were tried to be detected by the threshold value on the basis of the CT numbers. The soft X-ray absorption characteristics for acrylin plates and distilled water were obtained and could be found the possibility of detecting a small physical foreign materials such as a plastic wrapping film , a stone and grasshopper in food and agricultural products.

  • PDF

High-resolution Spectroscopy of the Nickel-like Molybdenum X-ray Laser Toward the Generation of Circularly Polarized X-ray Laser

  • Hasegawa, Noboru;Sasaki, Akira;Yamatani, Hiroshi;Kishimoto, Maki;Tanaka, Momoko;Ochi, Yoshihiro;Nishikino, Masaharu;Kunieda, Yuichi;Kawachi, Tetsuya;Yoneda, Hitoki;Iwamae, Atsushi
    • Journal of the Optical Society of Korea
    • /
    • 제13권1호
    • /
    • pp.60-64
    • /
    • 2009
  • We attempted the first measurement of the spectral width of the nickel-like molybdenum x-ray laser (${\lambda}\;=\;18.895\;nm$) by use of a high-resolution spectrometer in order to determine the strength of the magnetic field required for the generation of a circularly polarized x-ray laser. The spectral width was measured to be ${\Delta}{\lambda}\;=\;18\;m{\AA}$ under the substantial lasing condition. The magnetic field required for the generation of a circularly polarized x-ray laser was 40 T. The splitting of the x-ray laser line was clearly obtained under 15 T external magnetic field. The strength of the magnetic field estimated from the splitting of the x-ray laser line was large compared with the external magnetic field. It implies that there might be an alternative mechanism for enhancement of the magnetic field in the gain medium plasma.

고압하에서 방사광을 이용한 흑연에 대한 연구 (High pressure X-ray diffraction study on a graphite using Synchrotron Radiation)

  • Kim, Young-Ho;Na, Ki-Chang
    • 암석학회지
    • /
    • 제3권1호
    • /
    • pp.34-40
    • /
    • 1994
  • High pressure X-ray diffraction study was carried out on a graphite to investigate its compressibility as well as any possible phase transition to the hexagonal diamond structure at room temperature. Energy dispersive X-ray diffraction method was introduced using a Mao-Bell type diamond anvil cell with Synchrotron Radiation. Polycrystalline sodium chloride was compressed together with graphite for the high pressure determinations. Because of the poor resolution of the X-ray diffraction pattern of graphite, its compressibility was estimated to be almost same as that of NaCl by graphite (002) X-ray diffraction peak only. An observation of any new peak from a possible hexagonal diamond phase seems very unplausible for its definite identification based on the present data. Alternative approaches such as an Wiggler Radiation source as well as a Large Volume high pressure apparatus will be necessary for the detailed studies on a graphite in future.

  • PDF