• 제목/요약/키워드: High dose rate

검색결과 878건 처리시간 0.031초

FTIR study of gamma and electron irradiated high-density polyethylene for high dose measurements

  • Al-Ghamdi, Hanan;Farah, Khaled;Almuqrin, Aljawharah;Hosni, Faouzi
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.255-261
    • /
    • 2022
  • A reliable and well-characterized dosimetry system which is traceable to the international measurement system, is the key element to quality assurance in radiation processing with cobalt-60 gamma rays, X-rays, and electron beam. This is specifically the case for health-regulated processes, such as the radiation sterilization of single use medical devices and food irradiation for preservation and disinfestation. Polyethylene is considered to possess a lot of interesting dosimetric characteristics. In this work, a detailed study has been performed to determine the dosimetric characteristics of a commercialized high-density polyethylene (HDPE) film using Fourier transformed infrared spectrometry (FTIR). Correlations have been established between the absorbed dose and radiation induced infrared absorption in polyethylene having a maximum at 965 cm-1 (transvinylene band) and 1716 cm-1 (ketone-carbonyl band). We have found that polyethylene dose-response is linear with dose for both bands up to1000 kGy. For transvinylene band, the dose-response is more sensitive if irradiations are made in helium. While, for ketone-carbonyl band, the dose-response is more sensitive when irradiations are carried out in air. The dose-rate effect has been found to be negligible when polyethylene samples are irradiated with electron beam high dose rates. The irradiated polyethylene is relatively stable for several weeks after irradiation.

고선량율 질강 근접조사를 위한 새로운 적용구의 제작 (Design of a New Applicator for High-Dose Rate Vaginal Brachytherapy)

  • 신세원
    • Journal of Yeungnam Medical Science
    • /
    • 제17권2호
    • /
    • pp.123-128
    • /
    • 2000
  • 본 연구에서 인체공학적으로 개선된 새로운 2-채널 고선량을 근접치료용 적용구(Shin's Applicator)를 개발하였으며, 기존의 단일 선원 근접치료 적용구와 비교하여 질벽에 더 균등한 방사선치료가 가능하고 방광과 직장선량이 적어 근접치료 후 발생할 수 있는 부작용이 감소될 가능성을 확인하였다. 임상적으로 Shin's Applicator는 자궁 경부암이나 자궁 체부암의 수술 후 국소재발이나, 절강에 발생한 다발설 악성종양을 효과적으로 치료하는 데 유용하게 사용될 수 있을 뿐 만 아니라, 방사선 치료 후 흔히 나타나는 질강의 협착을 예방할 수 있는 질 확장기(vaginal dilator)로도 사용 가능하였다. 이상의 결과에서 Shin's Applicator는 부인과 종양환자들의 방사선치료 뿐만 아니라 치료 후 삶의 질의 개선에도 크게 기여할 것으로 생각되었다.

  • PDF

코발트-60 선원 대체용 고선량률 Ir-192 선원의 조직선량특성 (Characteristics of Tissue Dose of High Dose Rate Ir-192 Source Substitution for Co-60 Brachytherapy Source)

  • 최태진;이호준;김옥배
    • 한국의학물리학회지:의학물리
    • /
    • 제9권4호
    • /
    • pp.259-266
    • /
    • 1998
  • 코발트-60 근접조사선원을 대체할 Ir-l92 선원주변의 2차원적 선량분포를 얻기 위하여, 조사선량률과, 조직감쇠계수를 구하였다. 조직감쇠계수는 선원에서 20 cm 지점까지 실험식을 구하였다. ?보기 방사능은 조사선량상수를 사용하여 결정하였으며, 2.5mm 직경에 두께 2.5 mm 의 선원은 조직선량을 정하기 위해 선원을 4401 개로 분할하여 선원 자체의 흡수효과와 ?슐벽의 차폐 효과와 조직감쇠계수를 적용하였다. 조직감쇠계수는 4차식을 사용하여 1% 오차범위내에서 실험값을 얻을 수 있었으며, Meisberger 상수는 선원에서 많이 떨어질수록 오차가 커서, 10 cm 위치서 7%, 20 cm 에서 33%의 오차를 발견할 수 있었으나, 겉보기방사능과 선원모양 및 크기가 달라 다른 결과를 가져올 수 있다고 본다. 발표된 Ir-192 선원의 에너지스펙트럼을 이용한 선량률상수는 절삭에너지 10 keV인 경우 4.69 R$cm^2$/mCi-hr을 얻었으며 Air Kerma는 0.973 을 구하였다. 이 실험에서 고안 선원의 분할선원에 의한 선원자체흡수와 ?슐벽에 의한 감쇠는 실선원의 54.6%가 겉보기방사능으로 나타남을 알 수 있었으며, 선량계획에 이용하기 위해 단위 ?보기 방사능에 대한 2차원적 선량표를 준비함으로써 기하학적선량과 선량 비등방성을 쉽게 이용할 수 있도록 하였다.

  • PDF

고휘도 Power LED 의 고선량 감마선 조사 특성 (A High Dose-rate Gamma Irradiation of the High Brightness Power LED)

  • 조재완;최영수;신중철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.243-247
    • /
    • 2009
  • A Radioactive constraint of the nuclear fuel assembly irradiated by neutron during normal operation cycle of the nuclear power plant is typically on the order of about 3 kGy/h. In order to inspect nuclear fuel assembly using a VT (vision technology) system, the light such as halogen lamp is used. As the halogen lamp has lower color temperature than the sun light, the objects under halogen lamp illumination are seemed to be tinted with red. In this paper, high brightness LED is considered to be used as the light source of VT system. The high brightness LED, which is a key light source of the VT system, have been gamma irradiated at the dose rate of 4 kGy/h during two hours up to a total dose of 8 kGy. The radiation induced color-center in the LED housing cap made of plastics materials is observed.

  • PDF

A LONG-TERM FIELD TEST OF A LARGE VOLUME IONIZATION CHAMBER BASED AREA RADIATION MONITORING SYSTEM DEVELOPED AT KAERI

  • Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Kim, Jung-Bok;Kim, Young-Kyun;Jin, Hyung-Ho
    • Journal of Radiation Protection and Research
    • /
    • 제34권2호
    • /
    • pp.77-81
    • /
    • 2009
  • An Area Radiation Monitoring System (ARMS) ionization chamber, which had an 11.8 L active volume, was fabricated and performance-tested at KAERI. Low leakage currents, linearities at low and high dose rates were achieved from performance tests. The correlation coefficients between the ionization currents and the dose rates are 1 at high dose rate and 0.99 at low dose rate. In this study, an integration-type ARMS ionization chamber was tested over a year for an evaluation of its long-term stability at a radioisotope (RI) repository of the Young-gwang nuclear power plant. The standard deviation of dose rate of 1 day data and over a 100-days mean value were 6.2 $\mu$R/h and 2.9 $\mu$R/h, respectively. The fabricated ARMS ionization chamber showed stable performance from the results of the long-term tests. Design and performance characteristics of the fabricated ionization chamber for the ARMS from performance-tests are also addressed.

폴리프로필렌 부직포에 아크릴산의 방사선 그라프트 반응에서 금속염의 효과 (Radiation-Induced Grafting of Acrylic Acid onto Polypropylene Fabric in the Presence of Metallic Salt)

  • 노영창;박종신;진준하
    • 공업화학
    • /
    • 제7권5호
    • /
    • pp.946-953
    • /
    • 1996
  • 동시조사법에 의한 아크릴산의 폴리프로필렌 부직포에 대한 그라프트 반응에서 조사량, 조사선량률, 금속염 및 용매가 그라프트 반응에 미치는 영향을 조사하였다. 같은 조사선량에서는 선량률이 낮을수록 높은 그라프트율을 나타냈다. 한편 조사선량률을 달리하여 일정 시간 동안 그라프트 반응시키면 조사선량률이 높을수록 그라프트율은 높았으며, 첨가한 금속염의 종류에 관계없이 그라프트 속도는 조사선량률의 0.74 차수에 비례하였다. 사용한 금속염 중에서 $FeSO_4{\cdot}7H_2O$가 가장 우수하였으며, 첨가제의 함량이 증가하면 할수록 그라프트율은 감소하였지만 적정농도이하에서는 그라프트용액이 고화되어 그라프트 반응시킬 수 없었다.

  • PDF

자궁경부암 고선량율 강내치료의 치료선량 정확도에 관한 연구 (Accuracy of Dose Estimation in High Dose Rate Intracavitary Radiotherapy of Carcinoma of the Uterine Cervix)

  • 허승재;하성환;채규영
    • Radiation Oncology Journal
    • /
    • 제5권2호
    • /
    • pp.137-140
    • /
    • 1987
  • 자궁경부암의 고선량율 강내치료의 매 분할 치료시마다 강내 applicator의 위치 차이로 인하여 조사 선량이 치료전 계획된 선량과 차이가 있을 수 있다. 저자는 자궁경부암 환자의 강내치료시 치료전 계획된 A점 선량 500 cGy와 치료직후에 촬영한 전후 및 측면 선 사진을 이용하여 계산된 A점 선량을 비교한 결과, 82예의 강내치료에서 치료 후 계산된 조사 선량과 계획 선량은 $500\pm18 cGy$이었으며 $84\%$에서 $500\pm25 cGy$의 범위에 포함되었다. 이러한 결과에서 계획 선량과 치료 후 계산된 조사 선량사이에 비교적 높은 일치율을 확인할 수 있었다.

  • PDF

Personal computer를 이용한 자궁경부암의 고선량을 강내치료 계획 (Treatment Planning Software for High Dose Rate Remote Afterloading Brachytherapy of Uterine Cervical Cancer)

  • 허승재;강위생
    • Radiation Oncology Journal
    • /
    • 제4권2호
    • /
    • pp.183-186
    • /
    • 1986
  • 고선량율을 이용한 자궁강내 치료시 정확하고 신속한 계산을 위하여 저자들은 개인용 컴퓨터를 이용하여 기준점의 선량분포 및 방사선조사 시간을 간편하게 계산할 수 있는 software를 개발하였다. 치료 계획용 software를 이용하여 짧은 시간내에 선량 분포 및 조사시간을 용이하고 정확하게 계산할 수 있으며, 고선량을 자궁경부암 임상적응에 효과적으로 이용할 수 있어서 보고한다.

  • PDF

Development of a Wide Dose-Rate Range Electron Beam Irradiation System for Pre-Clinical Studies and Multi-Purpose Applications Using a Research Linear Accelerator

  • Jang, Kyoung Won;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Lee, Sang Jin;Kim, Jung Kee;Moon, Young Min;Kim, Jin Young;Jeong, Dong Hyeok
    • 한국의학물리학회지:의학물리
    • /
    • 제31권2호
    • /
    • pp.9-19
    • /
    • 2020
  • Purpose: This study aims to develop a multi-purpose electron beam irradiation device for preclinical research and material testing using the research electron linear accelerator installed at the Dongnam Institute of Radiological and Medical Sciences. Methods: The fabricated irradiation device comprises a dual scattering foil and collimator. The correct scattering foil thickness, in terms of the energy loss and beam profile uniformity, was determined using Monte Carlo calculations. The ion-chamber and radiochromic films were used to determine the reference dose-rate (Gy/s) and beam profiles as functions of the source to surface distance (SSD) and pulse frequency. Results: The dose-rates for the electron beams were evaluated for the range from 59.16 Gy/s to 5.22 cGy/s at SSDs of 40-120 cm, by controlling the pulse frequency. Furthermore, uniform dose distributions in the electron fields were achieved up to approximately 10 cm in diameter. An empirical formula for the systematic dose-rate calculation for the irradiation system was established using the measured data. Conclusions: A wide dose-rate range electron beam irradiation device was successfully developed in this study. The pre-clinical studies relating to FLASH radiotherapy to the conventional level were made available. Additionally, material studies were made available using a quantified irradiation system. Future studies are required to improve the energy, dose-rate, and field uniformity of the irradiation system.