• Title/Summary/Keyword: High dose

Search Result 4,239, Processing Time 0.03 seconds

Protective Effect of Astragalus polysaccharides on Liver Injury Induced by Several Different Chemotherapeutics in Mice

  • Liu, Wen;Gao, Fang-Fang;Li, Qun;Lv, Jia-Wei;Wang, Ying;Hu, Peng-Chao;Xiang, Qing-Ming;Wei, Lei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.23
    • /
    • pp.10413-10420
    • /
    • 2015
  • Side effects are an unavoidable consequence of chemotherapy drugs, during which liver injury often takes place. The current study was designed to investigate the protective effect of Astragalus polysaccharides (APS) against the hepatotoxicity induced by frequently-used chemical therapy agents, cyclophosphamide (CTX), docetaxel (DTX) and epirubicin (EPI)) in mice. Mice were divided into five groups, controls, low or high dose groups ($DTX_L$, $CTX_L$, $EPI_L$ or $DTX_H$, $CTX_H$, $EPI_H$), and low or high dose chemotherapeutics+APS groups ($DTX_L$+APS, $CTX_L$+APS, $EPI_L$+APS or $DTX_H$+APS, $CTX_H$+APS, $EPI_H$+APS). Controls were treated with equivalent normal saline for 28 days every other day; low or high dose group were intraperitoneal (i.p) injected with low or high doses of CTX, DTX and EPI for 28 days every other day; low or high dose chemotherapeutics+APS group were separately intraperitoneal (i.p) injected with chemotherapeutics for 28 days every other day and i.p with APS (100 mg/kg) for 7 days continually from the 22th to the 28th days. The body weight, serum levels of alanine aminotransferase (ALT) and aspartate aminotransferase (AST), histopathological features, and ultrastructure morphological change of liver tissues, protein expression level of caspase-3 were estimated at different time points. With high dose treatment of DTX, CTX and EPI, weight gain was inhibited and serum levels of ALT and AST were significantly increased. Sections of liver tissue showed massive hepatotoxicity in $CTX_H$ group compared to the control group, including hepatic lobule disorder, granular and vacuolar degeneration and necrosis in hepatic cells. These changes were confirmed at ultrastructural level, including obvious pyknosis, heterochromatin aggregation, nuclear membrane resolution, and chondrosome crystal decrease. Western blotting revealed that the protein levels of caspase-3 increased in $CTX_H$ group. The low dose groups exhibited trivial hepatotoxicity. More interestingly, after 100 mg/kg APS, liver injury was redecued not only regarding serum transaminase activities (low or high dose chemotherapeutics+APS group), but also from pathological and ultrastructural changes and the protein levels of caspase-3 ($CTX_H$+APS group). In conclusion, DTX, CTX and EPI induce liver damage in a dose dependent manner, whereas APS exerted protective effects.

Comparison of Noise and Doses of Low Dose and High Resolution Chest CT for Automatic Tube Current Modulation and Fixed Tube Current Technique using Glass Dosimetry (유리선량계를 이용한 관전류자동조절기법과 고정관전류기법에서 저선량 및 고해상 흉부CT의 노이즈 및 선량 비교)

  • Park, Tae Seok;Han, Jun Hee;Jo, Seung Yeon;Lee, Eun Lim;Jo, Kyu Won;Kweon, Dae Cheol
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.131-137
    • /
    • 2017
  • To compare the radiation dose and image noise of low dose computed tomography (CT) and high resolution CT using the fixed tube current technique and automatic tube current modulation (CARE Dose 4D). Chest CT and human anthropomorphic phantom were used the RPL (radiophotoluminescence) dosimeters. For image evaluation, standard deviation of mean CT attenuation coefficient and CT attenuation coefficient was measured using ROI analysis function. The effective dose was calculated using CTDIvol and DLP. CARE Dose 4D was reduced by 74.7% and HRCT by 64.4% compared to the fixed tube current technique in low dose CT of chest phantom. In CTDIvol and DLP, the dose of CARE Dose 4D was reduced by fixed tube current technique. For effective dose, CARE Dose 4D was reduced by 47% and HRCT by 46.9% compared to the fixed tube current method, and the dose of CARE Dose 4D was significantly different (p<.05). Noise in the image was higher than that in the fixed tube current technique. Noise difference in the image of CARE Dose 4D in low dose CT was significant (p<.05). The low radiation dose and the noise difference of the CARE Dose 4D were compared with the fixed tube current technique in low dose CT and HRCT using chest phantom. The radiation doses using CARE Dose 4D were in accordance with the national and international dose standards. CARE Dose 4D should be applied to low dose CT and HRCT for clinical examination.

Four-Week Oral Toxicity Study of CJ-50002 (Vibrio Vaccine) in Rats (CJ-50002(비브리오백신)의 랫드에 대한 4주간 경구 반복투여 독성연구)

  • 윤병일;정수연;김달현;이영수;김대용
    • Toxicological Research
    • /
    • v.15 no.1
    • /
    • pp.9-17
    • /
    • 1999
  • This study was performed to evaluate the subacute toxicity of CJ-50002 (Vibrio Vaccine) in SPF Spraqur-Dawley (SD) rats. Vibrio vaccine was administered orally at a dose level of high (167mg/kg/day), medium (16.7mg/kg/day), and low (16.7mg/kg/day) once a day and repeated fro 4 weeks. Ten males and female rats were assigned to each group. After 4 week administration, no significant dose-dependent changes in body weight, water and food consumption rate or organ weight were noted dependent changes in body weight, water and food consumption rate or organ weight were noted among 4 groups. Urinanalysis, hematology, and serum chemistry, also fail to detect any dose-related change among 4 groups tested. During necropsy and histopathological examination, no specific toxicity related to treated material was found. The result of this study demonstrated that vibrio vaccine when administered orally for 4 weeks at a high dose of 167mg/kg/day, no dose-related toxicity was found in treated make and female rats.

  • PDF

A SOLUTION TO THE PROBLEM WITH ABSORBED DOSE

  • Braby, Leslie A.
    • Nuclear Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.533-538
    • /
    • 2008
  • In some situations, for example at very low doses, in microbeam irradiation experiments, or around high energy heavy ion tracks, use of the absorbed dose to describe the energy transferred to the irradiated target can be misleading. Since absorbed dose is the expected value of energy per mass it takes into account all of the targets which do not have any energy deposition. In many situations that results in numerical values, in Joules per kg, which are much less than the energy deposited in targets that have been crossed by a charged particle track. This can lead to confusion about the biochemical processes that lead to the consequences of irradiation. There are a few alternative approaches to describing radiation that avoid this potential confusion. Examples of specific situations that can lead to confusion are given. It is concluded that using the particle radiance spectrum and the exposure time, instead of absorbed dose, to describe these irradiations minimizes the potential for confusion about the actual nature of the energy deposition.

Evaluation of the Antidiabetic, Islet Protective and Beta-Cell Regenerative Effects of Tinospora crispa (L.)

  • Yusof, Norafiqah;Goh, May P. Y.;Ahmad, Norhayati
    • Natural Product Sciences
    • /
    • v.28 no.3
    • /
    • pp.105-114
    • /
    • 2022
  • Tinospora crispa (L.) is a medicinal plant traditionally used to treat various ailments including diabetes. The stem has been widely studied for its antidiabetic properties, however the antidiabetic potential of its leaves has not been explored. This study investigates the antidiabetic properties of methanolic T. crispa stem and leaves extracts on alloxan-induced diabetic rats. The stems and leaves were extracted using Soxhlet extraction with methanol as solvent. Crude extracts were administered at 500 mg/kg body weight (BW) (high dose) and 250 mg/kg BW (low dose) via oral route to alloxan induced diabetic rats. T. crispa stem and leaves extracts was found to significantly reduce blood glucose following a twelve-week treatment period. The highest mean difference in blood glucose level was exhibited by animals in the high dose treated stem and low dose leaf extracts. Both extracts showed approximately 75% percentage recovery from hyperglycaemia. The highest regenerative capacity was observed in animals treated with the low dose leaf extract.

Late Rectal Complication in Patients treated with High Dose Rate Brachytherapy for Stage IIB Carcinoma of the Cervix (FIGO병기 IIB 자궁경부암에서 고선량 강내 방사선치료후의 후기 직장 합병증)

  • Chung, Eun-Ji;Kim, Gwi-Eon;Suh, Chang-Ok;Keum, Ki-Chang;Kim, Woo-Cheol
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.41-52
    • /
    • 1996
  • Purpose : This paper reports a dosimetric study of 88 patients treated with a combination of external radiotherapy and high dose rate ICR for FIGO stage IIB carcinoma of the cervix. The purpose is to investigate the correlation between the radiation doses to the rectum, external radiation dose to the whole pelvis, ICR reference volume, TDF BED and the incidence of late rectal complications, retrospectively. Materials and Methods : From November 1989 through December 1992, 88 patients with stage IIB cervical carcinoma received radical radiotherapy at Department of Radiation Oncology in Yonsei University Hospital. Radiotherapy consisted of 44-54 Gy(median 49 Gy) external beam irradiation plus high dose rate intracavitary brachytherapy with 5 Gy per fraction twice a week to a total dose of 30 Gy on point A. The maximum dose to the rectum by contrast(r, R) and reference rectal dose by ICRU 38(dr, DR) were calculated. The ICR reference volume was calculated by Gamma Dot 3.11 HDR planning system, retrospectively The time-dose factor(TDF) and the biologically effective dose (BED) were calculated. Results : Twenty seven($30.7\%$) of the 88 patients developed late rectal complications:12 patients($13.6\%$) for grade 1, 12 patients($13.6\%$) for grade 2 and 3 patients($3.4\%$) for grade 3. We found a significant correlation between the external whole pelvis irradiation dose and grade 2, 3 rectal complication. The mean dose to the whole pelvis for the group of patients with grade 2, 3 complication was Higher, $4093.3\pm453.1$ cGy, than that for the patients without complication, $3873.8\pm415.6$ (0.05$7163.0\pm838.5$ cGy, than that for the Patients without rectal complication, $0772.7\pm884.0$ (p<0.05). There was no correlation of the rate of grade 2, 3 rectal complication with the iCR rectal doses(r, dr), ICR reference volume, TDF and BED. Conclusion : This investigation has revealed a significant correlation between the dose calculated at the rectal dose by ICRU 38(DR) or the most anterior rectal dose by contrast(R) dose to the whole pelvis and the incidence of grade 2, 3 late rectal complications in patients with stage IIB cervical cancer undergoing external beam radiotherapy and HOR ICR. Thus these rectal reference points doses and whole pelvis dose appear to be useful Prognostic indicators of late rectal complication in high dose rate ICR treatment in cervical carcinoma.

  • PDF

Studies on Digitalis Receptor Desensitization in Rat Ventricle

  • Lee, Shin-Woong-;Jang, Tae-Soo
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1994.04a
    • /
    • pp.301-301
    • /
    • 1994
  • $^3$H〕Ouabain binding parameters(K$\_$D/ and B$\_$max/,) in homogenates prepared fpom control rat ventricular strip and Langendorff preparations which were not previously exposed to ouabain were compared to those in homogenates from ventricular strip and Langendorff preparations that had been first exposed to a complete ouabain dose-response curve(10$\^$-7/M to 10$\^$-4/ M). In rat ventricular strips and Langendorff perfused rat heart preparations, cumulative dose-response cruves of ouabain revealed biphasic positive inotropic effects, a "low-dose" and a "high-dose" effect with ED$\_$50/ values of 0.5${\mu}$M and 35${\mu}$M ouabain, respectively- The "low-dose" effect in rat ventricular strips disappeared or was diminished significantly when the ouabain dose-response curve wag repeated after the washout of the effects of the first curve, whereas the maximal "high-dose" effect was identical in both exposures to oubain. However, there was no change in the "low-dose" effects in both sets of the Langendorff perfused hearts. The contractile activity of the pre-exposed strips did not indicate the presence of residual ouabain since their basal contractile force was decreased 10% compared to initial control. 〔$^3$H〕Ouabain binding parameters, K$\_$D/ and B$\_$max/, were not changed comparing homogenate of control ventricular strips with that of strips pre-exposed to ouabain. These results suggest that digitalis receptor desensitization in the rat ventricular strip may due to the change of post-receptor events induced by ouabain binding to a high affinity site(${\alpha}$$_2$ isoform).

  • PDF

Design of a New Applicator for High-Dose Rate Vaginal Brachytherapy (고선량율 질강 근접조사를 위한 새로운 적용구의 제작)

  • Shin, Sei One
    • Journal of Yeungnam Medical Science
    • /
    • v.17 no.2
    • /
    • pp.123-128
    • /
    • 2000
  • Purpose: This study was aimed to develop a new vaginal applicator(Shin's Applicator) for 2-channel high-dose rate vaginal brachytherapy to evaluate uniformity of surface dose, and to present 3-dimensional dose distribution of the applicator. Methods: Shin's Applicator was inexpensively constructed using human soft tissue equivalent acrylic bar. We evaluated dose uniformity along the applicator surface using film densitometer and performed vaginal intracavitary brachytherapy after insertion of the applicator using HDR brachytherapy planning software and brachytherapy unit(Ralstron-20B). Results: Shin's Applicator allows improved dose distribution than the existing 1-channel cylinder and achieves diminished urinary bladder and rectal dose by 20%. Conclusions: From the above results, it can be concluded that Shin's Applicator may be an improved form of a vaginal applicator. Furthermore, it can be suggested that this applicator has an advantage, for it prevents vaginal stenosis after radiation therapy and can be used as a disposable vaginal dilator. Further follow up examination with radiological study may be helpful to evaluate the therapeutic efficacy of this applicator.

  • PDF

Current Status of High Dose Rate Brachytherapy in Cervical Cancer in Korea and Optimal Treatment Schedule (자궁 경부암 고선량율 강내조사 치료의 국내 현황과 적정 치료방법)

  • Huh, Seung-Jae
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.357-366
    • /
    • 1998
  • Brachytherapy is an essential part of radiotherapy for uterine cervical cancer. The low dose rate (LDR) regimen has been the major technique of intracavitary therapy for cervical cancer. However, there has been an expansion in the last 20 years of high dose rate (HDR) machines using Ir-192 sources. Since 1979, HDR brachytherapy has been used for the treatment of uterine cervical cancer in Korea. The number of institutions employing HDR has been increasing, while the number of low dose rate system has been constant. In 1995, there was a total 27 HDR brachytherapy units installed and 1258 cases of patients with cervical cancer were treated with HDR Most common regimens of HDR brachytherapy are total dose of 30-39 Gy at point A with 10-13 fractions in three fractions per week. 24-32 Gy with 6-8 fractions in two fractions per week, and 30-35 Gy with 6-7 fractions in two fractions per week. The average fractionation regimen of HDR brachytherapy is about 8 fractions of 4.1 Gy each to Point A. In Korea, treatment results for HDR brachytherapy are comparable with the LDR series and appears to be a safe and effective alternative to LDR therapy for the treatment of cervical carcinoma. Studies from the major centers report the five-year survival rate of cervical cancer as. 78-86$\%$ for Stage 1, 68-85$\%$ for stage 11, and 38-56$\%$ for Stage III. World-wide questionnaire study and Japanese questionnaire survey of multiple institutions showed no survival difference in any stages and dose-rate effect ratio (HDR/LDR) was calculated to be 0.54 to 0.58. However the optimum treatment doses and fractionation schemes appropriate to generate clinical results comparable to conventional LDR schemes have yet to be standardized. In conclusion, HDR intracavitary radiotherapy is increasingly practiced in Korea and an effective treatment modality for cervical cancer. To determine the optimum radiotherapy dose and fractionation schedule, a nation-wide prospective study is necessary in Korea. In addition, standardization of HDR application (clinical, computer algorithms, and dosimetric aspects) is necessary.

  • PDF

High-Dose-Rate Electron-Beam Dosimetry Using an Advanced Markus Chamber with Improved Ion-Recombination Corrections

  • Jeong, Dong Hyeok;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Jang, Kyoung Won
    • Progress in Medical Physics
    • /
    • v.31 no.4
    • /
    • pp.145-152
    • /
    • 2020
  • Purpose: In ionization-chamber dosimetry for high-dose-rate electron beams-above 20 mGy/pulse-the ion-recombination correction methods recommended by the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM) are not appropriate, because they overestimate the correction factor. In this study, we suggest a practical ion-recombination correction method, based on Boag's improved model, and apply it to reference dosimetry for electron beams of about 100 mGy/pulse generated from an electron linear accelerator (LINAC). Methods: This study employed a theoretical model of the ion-collection efficiency developed by Boag and physical parameters used by Laitano et al. We recalculated the ion-recombination correction factors using two-voltage analysis and obtained an empirical fitting formula to represent the results. Next, we compared the calculated correction factors with published results for the same calculation conditions. Additionally, we performed dosimetry for electron beams from a 6 MeV electron LINAC using an Advanced Markus® ionization chamber to determine the reference dose in water at the source-to-surface distance (SSD)=100 cm, using the correction factors obtained in this study. Results: The values of the correction factors obtained in this work are in good agreement with the published data. The measured dose-per-pulse for electron beams at the depth of maximum dose for SSD=100 cm was 115 mGy/pulse, with a standard uncertainty of 2.4%. In contrast, the ks values determined using the IAEA and AAPM methods are, respectively, 8.9% and 8.2% higher than our results. Conclusions: The new method based on Boag's improved model provides a practical method of determining the ion-recombination correction factors for high dose-per-pulse radiation beams up to about 120 mGy/pulse. This method can be applied to electron beams with even higher dose-per-pulse, subject to independent verification.