• 제목/요약/키워드: High dose

검색결과 4,271건 처리시간 0.04초

흉부 전·후방향 검사 시 고관전압 및 산란선 후처리 소프트웨어 적용이 화질과 선량에 미치는 영향 (Effect of High Tube Voltage and Scatter Ray Post-processing Software on Image Quality and Radiation Dose During Chest Anteroposterior Radiography)

  • 김종석;주영철;이승근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권4호
    • /
    • pp.295-300
    • /
    • 2021
  • This study aims to present new chest AP examination exposure conditions through a study on the effect on image quality and patient dose by applying high tube voltage and scatter ray post-processing software during chest AP examination in digital radiography equipment. This study was used a human body phantom and in the chest AP position, the dosimeter was placed horizontally at the thoracic spine 6. The experiment was conducted by dividing into a low tube voltage (70 kVp, 400 mA, 3.2 mAs) group and a high tube voltage (100 kVp, 400 mA, 1.2 mAs) group. The collimation size (14″× 17″) and the source to image receptor distance(110 cm) were same applied to both groups. Radiation dose was presented to dose area product and entrance surface dose. Image quality was compared and analyzed by comparing the difference between the signal-to-noise ratio and the contrast-to-noise ratio of the image according to the application of the scatter ray post-processing software under each condition. The average value of the entrance surface dose in the low and high tube voltage conditions was 93.04±0.45 µGy and 94.25±1.51 µGy, which was slightly higher in the high tube voltage condition, but the dose area product was 0.97±0.04 µGy and 0.93±0.01 µGy. There was a statistically significant difference in the group mean value(p<0.01). In terms of image quality, the values of the signal-to-noise ratio and the contrast noise ratio were higher in the high tube voltage than in the low tube voltage, and decreased when the scattering line post-processing function was used, but the contrast resolution was improved. If there is a scatter ray post-processing function during chest AP examination, it is helpful to actively utilize it to improve the image quality. However, when this function is not available, I thought that applying a higher tube voltage state than a low tube voltage state will help to realize images with a large amount of information without changing the dose.

장단기 고용량 카페인 투여가 청소년기 동물모델의 행동에 미치는 영향 (Influence of Short- and Long-term High-dose Caffeine Administration on Behavior in an Animal Model of Adolescence)

  • 박종민;김윤주;김하은;김연정
    • Journal of Korean Biological Nursing Science
    • /
    • 제21권3호
    • /
    • pp.217-223
    • /
    • 2019
  • Purpose: Caffeine is the most widely consumed psychostimulant of the methylxanthine class. Among adolescents, high-dose of caffeine consumption has increased rapidly over the last few decades due to the introduction of energy drinks. However, little is known about the time-dependent effect of high doses of caffeine consumption in adolescents. The present study aims to examine the short- and long-term influence of high-dose caffeine on behavior of adolescence. Methods: The animals were divided into three groups: a "vehicle" group, which was injected with 1 ml of phosphate-buffered saline for 14 days; a "Day 1" group, which was injected with caffeine (30 mg/kg), 2 h before the behavioral tests; and a "Day 14" group, which was infused with caffeine for 14 days. An open-field test, a Y-maze test, and a passive avoidance test were conducted to assess the rats'activity levels, anxiety, and cognitive function. Results: High-dose caffeine had similar effects in short-and long-term treatment groups. It increased the level of locomotor activity and anxiety-like behavior, as evidenced by the increase in the number of movements and incidences of rearing and grooming in the caffeine-treated groups. No significant differences were observed between the groups in the Y-maze test. However, in the passive avoidance test, the escape latency in the caffeine-treated group was decreased significantly, indicating impaired memory acquisition. Conclusion: These results indicate that high-dose caffeine in adolescents may increase locomotor activity and anxiety-like behavior and impair learning and memory, irrespective of the duration of administration. The findings will be valuable for both evidence-based education and clinical practice.

Insights from an OKMC simulation of dose rate effects on the irradiated microstructure of RPV model alloys

  • Jianyang Li;Chonghong Zhang;Ignacio Martin-Bragado;Yitao Yang;Tieshan Wang
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.958-967
    • /
    • 2023
  • This work studies the defect features in a dilute FeMnNi alloy by an Object Kinetic Monte Carlo (OKMC) model based on the "grey-alloy" method. The dose rate effect is studied at 573 K in a wide range of dose rates from 10-8 to 10-4 displacement per atom (dpa)/s and demonstrates that the density of defect clusters rises while the average size of defect clusters decreases with increasing dose rate. However, the dose-rate effect decreases with increasing irradiation dose. The model considered two realistic mechanisms for producing <100>-type self-interstitial atom (SIA) loops and gave reasonable production ratios compared with experimental results. Our simulation shows that the proportion of <100>-type SIA loops could change obviously with the dose rate, influencing hardening prediction for various dose rates irradiation. We also investigated ways to compensate for the dose rate effect. The simulation results verified that about a 100 K temperature shift at a high dose rate of 1×10-4 dpa/s could produce similar irradiation microstructures to a lower dose rate of 1×10-7 dpa/s irradiation, including matrix defects and deduced solute migration events. The work brings new insight into the OKMC modeling and the dose rate effect of the Fe-based alloys.

Beagle Dog에서 cis-Malonato[(4R,5R)-4,5-bis(aminomethyl)-2-isopropyl-1,3-dioxolane]platinum(II)(SKI 2053R)의 아급성독성시험에 관한 연구 (Subacute toxicity of cis-Malonato[(4R,5R)-4,5-bis(aminomethyl)-2-isopropyl-1,3-dioxolane]platinum(II)(SKI 2053R) in Beagle Dogs)

  • 이영순;강경선;신동진;조재진;김형욱;김배환;임윤규
    • Toxicological Research
    • /
    • 제8권2호
    • /
    • pp.235-253
    • /
    • 1992
  • A subacute toxicity study of cis-Malonato[(4R,5R)-4,5-bis(aminomethyl)-2-isopropyl-1,3-dioxolane]platinum(II)(SKI 2053R) was carried out to obtain information on its toxicological profiles, and to determine the maximum tolerated dose in beagle dogs. Four groups of beagle dogs (2M and 2F per group, 0,0.5,1.0,2.0mg/kg/day)were given 15 i.v. injections of SKI 2053R. In order to compare the toxic effects of SKI 2053R with those of cisplatin, one group was treated with cisplatin(0.7mg/kg/day)according to the same treatment schedule. The dosing schedule was divided into 3 courses of 5 consecutive days with 23-day dose-free intervals between each course. After completion of the treatments, remaining dogs were necropsied under established guidelines. Three of four dogs in the high dose group and one of four dogs in the middle dose group treated with SKI 2053R died of hypovolemic shock secondary to hemorrhagic and ulcerative enterocolitis. No toxicity-related mortality occurred in the low dose group of SKI 2053R. No survivor was observed in the group of cisplatin. Clinical signs including vomiting, diarrhea, anorexia and loss body weight were apparent in dogs given either cisplatin or high and middle doses of SKI 2053R. Severe thrombocytopenia and leukocytopenia were observed in the high dose group of SKI 2053R and cisplatin-treatment group, while toxicities as bone marrow suppression were reversible. The significant elevation of serum ALP values in group of SKI 2053R(2.0 mg/kg/day and 1.0mg/kg/day) and cisplatin(0.7mg/kg/day)was observed. Slight proteinuria waa observed in high and middle dose level groups of SKI 2053R. In histopathological examinations, pathological alterations of liver, kidney and spleen were noted dose-dependantly in dogs treated with SKI 2053R, and there was no overt sign of toxicity in low dose group of SKI 2053R. Compared to SKI 2053R, more severe durg-related toxicities occurred in dogs treated with cisplatin. It waw estimated that maximum tolerated dose of SKI 2053R in this treatment schedule was 0.5~0.7mg/kg/day. In conclusion, overall toxic potential of SKI 2053R was approximately 3 times lower than that of cisplatin with respect of lethality.

  • PDF

흉부 전산화단층촬영검사를 위한 최적의 저선량 프로토콜에 관한 팬텀연구 (A Phantom Study for the Optimal Low-dose Protocol in Chest Computed Tomography Examination)

  • 김영근;양숙;왕태욱;김은혜
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권2호
    • /
    • pp.101-107
    • /
    • 2021
  • The purpose of this study was to evaluate optimal CT scan parameters to minimize patient dose to the irradiation and maintain satisfactory image quality in low-dose chest computed tomography (CT) scans. In a chest anthropomorphic phantom, chest CT scans were performed at different kVp and mA within reference of 3.4mGy in volume CT Dose Index (CTDIvol). The following quantitative parameters had been statistically evaluated: image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM). Nine radiographers conducted the blind test to select the optimal kVp-mA combination. Results indicated that the kVp-mA combination of 80kVp-90mA, 100kVp-50mA, 120kVp-30mA and 140kVp-30mA were obtained high SNR and CNR. The 120kVp-30mA combination offered good compromise in the FOM, which showed the quality and dose performance. In the blind test, an image of 80kVp-90mA obtained a high score with 4.7 points, and 120kVp-10mA or 140kVp-10mA with a low tube current were observed severe noise and poor image quality, thus resulting in decreased diagnostic accuracy. On the other hand, in the combination of high kVp and high mA(140kVp-90mA), the image quality was improved, but the radiation dose was also increased. the FOM value of 140kVp-90mA was lower than 120kVp-30mA. The application of appropriate scan parameters in low-dose chest CT scans produced satisfactory results in dose and image quality for the accuracy of the clinical diagnosis.

CHANGING OF RGS TRANSCRIPTS LEVELS BY LOW-DOSE-RATE IONIZING RADIATION IN MOUSE TESTIS

  • Kim, Tae-Hwan;Baik, Ji Sue;Heo, Kyu;Kim, Joong Sun;Lee, Ki Ja;Rhee, Man Hee;Kim, Sung Dae
    • Journal of Radiation Protection and Research
    • /
    • 제40권3호
    • /
    • pp.187-193
    • /
    • 2015
  • Deleterious effects of high dose radiation exposure with high-dose-rate are unarguable, but they are still controversial in low-dose-rate. The regulator of G-protein signaling (RGS) is a negative regulator of G protein-coupled receptor (GPCR) signaling. In addition, it is reported that irradiation stress led to GPCR-mediated mitogen-activated protein kinase (MAPK) and phosphotidylinositol 3-kinase (PI3-k) signaling. The RGS mRNA expression profiles by whole body radiation with low-dose-rate has not yet been explored. In the present study, we, therefore, examined which RGS was modulated by the whole body radiation with low-dose-rate ($3.49mGy{\cdot}h^{-1}$). Among 16 RGS expression tested, RGS6, RGS13 and RGS16 mRNA were down-regulated by low-dose-rate irradiation. This is the first report that whole body radiation with low-dose-rate can modulate the different RGS expression levels. These results are expected to reveal the potential target and/or the biomarker proteins associated with male testis toxicity induced by low-dose-rate irradiation, which might contribute to understanding the mechanism beyond the testis toxicity.

MCNPX를 이용한 방사선 치료실의 광중성자 선량 평가 (Evaluation of Photoneutron Dose in Radiotherapy Room Using MCNPX)

  • 박은태
    • 한국콘텐츠학회논문지
    • /
    • 제15권6호
    • /
    • pp.283-289
    • /
    • 2015
  • 현재 방사선치료는 치료효과를 높이기 위해 고에너지 광자선의 사용이 증가하고 있는 추세이다. 일반적으로 6~8 MeV 이상의 고에너지 광자선을 사용하는 경우에는, 광핵반응에 의한 광중성자가 발생됨으로써 방사선 방호의 측면에서 많은 문제를 야기 시킬 수 있다. 이에 본 연구는 MCNPX를 이용하여 방사선 치료실의 광중성자 선량분포를 분석하였다. 그 결과 10 MV와 12 MV 구간에서 급격한 흡수선량의 증가를 보였다. 이를 통해 10 MV를 시작으로 광중성자 플루언스의 급격한 증가가 흡수선량으로 연계됨을 알 수 있었다. 또한 산출된 흡수선량을 바탕으로 등가선량을 환산한 결과는 ICRP 103 권고안의 경우, 낮은 에너지 범위에서 인체의 흡수선량에 대한 2차 광자의 기여를 반영함으로써 ICRP 60 권고안에 비해 낮은 등가선량을 나타냈다.