• 제목/요약/키워드: High current measuring

검색결과 478건 처리시간 0.026초

대전류 측정용 Tubular Coaxial Shunt 특성에 관한 연구 (The Study of Characteristics of Tubular Type Coaxial Shunt for High Current Measuring System)

  • 노창일;나대열;김선구;정흥수;김원만;이동준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.834-836
    • /
    • 2003
  • This paper describes the optimal design, construction and performance evaluation of coaxial shunts used in high current testing laboratory for current measuring system. These shunts, which are of tubular type coaxial shunts, the currents to be measured range from Amperes to several kiloAmperes, and the frequency of the signals has a bandwidth from DC to megaHertz. The shunt must have the mechanical strength to support the forces produced by the transient current, above all, the measuring capabilities of shunt are dependent upon short response time and it must be as free as possible of inductive effects. In this paper presents both characteristic of shunt and design of tubular type coaxial shunt.

  • PDF

가변부하 적용을 위한 고정밀 교류전원 제어시스템 (A High-precision AC Power Control System for Variable Loads Application)

  • 한운동;손진근
    • 한국ITS학회 논문지
    • /
    • 제7권3호
    • /
    • pp.74-81
    • /
    • 2008
  • 고정밀 교류전원 제어시스템은 교통관제등과 같은 가변 부하를 운영하는데 중요하다. 이러한 시스템은 가변부하에 대응하기 위하여 제어의 정밀성이 요구되며, 이를 위하여 AC/DC/AC 변환이 가능한 인버터를 주로 사용하게 된다. 따라서 본 논문에서는 고정밀 전류제어를 수행하기 위하여 개선된 전류계측 기법을 이용한 제어시스템을 제안하였다. 제안된 계측기법은 전류의 궤환된 계측을 순시적 실효치의 이동평균법을 사용하여 응답 및 정밀성을 개선한 방식이다. 컴퓨터 시뮬레이션 및 실험의 결과는 제안된 시스템의 타당성을 입증할 수 있었으며, 이는 항공관제 유도시스템의 조명제어 장치에도 폭넓게 적용되리라 사료된다.

  • PDF

태양광 패널 재사용을 위한 가변 정전류 기반의 효율 측정장치에 관한 연구 (Research on Variable Constant Current Efficiency Measuring Device for Solar Panel to Reuse)

  • 우상진;김대헌;이재진;권오민
    • 대한임베디드공학회논문지
    • /
    • 제18권1호
    • /
    • pp.9-17
    • /
    • 2023
  • This paper relates to the development of a device for measuring the efficiency of a solar panel based on a variable constant current, and proposed a standard for reuse of the solar panel. By applying a variable constant current circuit to a solar panel efficiency measuring device, it was easy to apply a maximum power point tracking (MPPT) algorithm. In addition, a load dispersion method was applied to measure the efficiency of a high-capacity solar panel. and it is possible to solve a problematic thermal runaway during a MOSFET parallel operation by applying the load dispersion method. As a result of the experiment, the solar panel efficiency measuring device was able to accommodate a large solar panel of 350W, which is the maximum measurement goal. In this paper, the validity was confirmed through the 310W solar panel efficiency measurement experiment collected after removal.

WBG 소자를 위한 높은 측정 감도를 가지는 PCB 내장형 Spiral 패턴 Pick-up Coil 전류 측정 기법 (PCB Integrated Spiral Pattern Pick-up Coil Current Measurement Scheme with High Sensitivity for WBG Devices)

  • 김경모;차화랑;김래영
    • 전력전자학회논문지
    • /
    • 제25권3호
    • /
    • pp.162-170
    • /
    • 2020
  • In this paper, we report our study of the current measuring technique by implementing a pick-up coil in the PCB pattern instead of the current measuring sensor in a power converter using a WBG device. The proposed PCB pattern coil structure has a higher mutual inductance value than the conventional pattern by constructing the coil using the multi layer board. It has high sensitivity and is configured without additional process outside the PCB. In the current measurement, the integrator is measured by integrating the coil at the back end and the current waveform measured using proposed pick-up coil is confirmed by comparing it with the original current waveform through DPT simulation.

부분방전전류측정을 위한 로고스키코일의 적용에 관한 연구 (Study about the Application of Rogowski Coil for measuring Partial Discharge Current)

  • 이강원;윤성철;김명룡;백광선;나동희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1378-1383
    • /
    • 2004
  • Rogowski coil is a kind of sensor for high amplitude and very short period current and suitable for the measurement of PD pulse. This paper have simulated the relations between PD signals and Rogowski coil which has its own equivalent circuit and investigated signals of Rogowski coil induced by PD pulse current. and compared with the PD signal obtained from conventional PD measuring system in accordance with IEC60270.

  • PDF

Application of an Optical Current Transformer For Measuring High Current

  • Kim, Yeong-Min;Park, Won-Zoo
    • 조명전기설비학회논문지
    • /
    • 제24권11호
    • /
    • pp.9-16
    • /
    • 2010
  • This paper examines the temperature characteristics of an Optical CT (optical current transformer) using the Faraday effect for measuring high current in a super high voltage-power apparatus. It is performed as follows by the sensor for embodying Faraday effect. $\cdot$ A single-mode optical fiber capable of maintaining a polarization state is used. $\cdot$ A light source is applied at 1310[nm] to a Laser Diode. $\cdot$ The Linear of Faraday effect to a large current is evaluated and $\cdot$ A possible application using an Optical CT was shown. An Influence of Faraday effect to the surrounding temperature measured -40~50[$^{\circ}C$], and the characteristic of the current sensitivity was reported. An application using the results of the temperature compensation system was used in order to compensate for surrounding temperatures. A possibility of applying Optical CT for electric power apparatus was advanced further. We were able to confirm that this temperature calibration method can minimize the fluctuation of the output signal depending on the temperature conditions.

Measuring the Earth's Size Using the Sun's Altitude and The Responses

  • Chae, Dong-Hyun
    • 대한지구과학교육학회지
    • /
    • 제5권1호
    • /
    • pp.88-94
    • /
    • 2012
  • This study was created to resolve the problems embedded in the formal measuring experiments to determine the earth's size in the current curriculum, to develop an updated measuring experiment to determine the earth's size and to establish its effect. For this study, pre-service elementary teachers, who had attempted the experiment of measuring the size of the earth when they were in middle school, performed the experiments in the existing national curriculum, and their responses, collected through in-depth interviews, were examined. To begin with, the pre-service elementary teachers conducted the experiment of measuring the earth size and they recorded the problems while performing it. At the end, an in-depth interview was administered. Based on the problems, an updated measuring experiment to determine the earth's size was suggested to be applied to the same contents and be analyzed through the in-depth interviews. Common themes which were mutually categorized and analyzed by the two researchers were obtained based on the records produced while conducting the experiment and the in-depth interview data. The teachers mentioned that the experiments for measuring the size of the earth in the current curriculum gave rise to difficulties in measuring precisely the angles between the string and the post. Also, there has been a scientific contradiction that solar altitudes were increased in a high latitude region, instead of decreased. For this reason, an alternative method has been developed to measure the earth's size using the distance and the solar altitude difference of two places. The teachers all agreed that by using the updated measuring experiment, they can acquire more precise measurements and it is easier, faster and consequently more effective than the existing methods. Through the results of this study, I suggest that the newly developed experiment by the researchers can overhaul the problems of the current experiments and it can be an effective alternative to the current experiment.

6.6 kV 케이블의 절연저항 측정을 위한 부하전류 및 온도 측정 (Load Current and Temperature Measurement for Measuring the Insulation Resistance of the 6.6 kV Cable)

  • 박용규;조영식;이관우;엄기홍;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제28권1호
    • /
    • pp.46-50
    • /
    • 2015
  • The cable degradation process is largely divided into three steps; Step 1 : Thermal degradation, Step 2 : Weibull degradation, Step 3 : Partial discharge. it is progress in step order. This article aims to explain the process of cable degradation using the method of insulation resistance and accordingly to compose and manufacture a system of measuring the life of electrical cable. Before measuring the insulation resistance, a system of measuring the temperature and current of cables was made, and the established system was installed for test on the site of a power plant to collect the measured data. The current sensor was used TFC30P80A-CL420, and temperature sensor was used the DK-1270 PT100 sensor as RTD sensor. When measured the temperature and the load current at the same position, was confirmed that in case of the load current value was high, also temperature value high. Therefore, the correlation between load currents and temperature was verified, and the analysis of diagnostic data was evaluated, which could be utilized in identifying the fault condition of cable systems.

3상 90 MVA 단시간전류시험 설비 구축 (The construction of 3-phase 90 MVA short-time withstand current testing facilities)

  • 서윤택;김용식;윤학동;김맹현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.700-702
    • /
    • 2005
  • The most electrical apparatus should be able to withstand short-time current and peak current during a specified short time until circuit breakers have interrupted fault current. It defines the short-time withstand ability of electric a apparatus to be remain for a time interval under high fault current conditions. It is specified by both dynamic ability and thermal capability. KERI(Korea Electrotechlology Research Institute) recently constructed the new short-time current and low voltage short circuit testing facilities. This paper shows short- circuit calculation of transformer and describes high current measuring system, and evaluate the result of short-time withstand test used in $3{\phi}$ 90MVA short-time current testing facilities.

  • PDF