• Title/Summary/Keyword: High current measuring

Search Result 478, Processing Time 0.03 seconds

A calibration of high current measuring sensors by comparison tests (비교 시험에 따른 대전류 측정 센서 교정 결과 분석)

  • Han, Jong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.312-313
    • /
    • 2015
  • For the traceability of high current measuring sensors of high power testing department II(HPTD II) in Korea Electrotechnology Research Institute(KERI), additional comparison tests with reference test object were performed repeatedly. The first intercomparison has been carried out between the reference shunt for Asia and high current shunt of HPTD II in 2013. This paper compares the test results of the calibration in 2014 with them in 2015. The assigned new scale factor of high current sensors will be applied to high power tests in HPTD II until the next high current intercomparison.

  • PDF

Feasibility of Using the Clamp Meter in Measuring X-Ray Tube Current

  • Kim, Sung-Chul
    • International Journal of Contents
    • /
    • v.9 no.1
    • /
    • pp.38-41
    • /
    • 2013
  • The clamp meter maintains electric safety as a non-invasive method while measuring the absolute value of tube current with it has been recently developed for an X-ray high-tension cable. Especially this can show high accuracy at short X-ray exposure time. Considering such a condition, this study is to evaluate the feasibility of a clamp meter in measuring X-ray tube current by taking the measurements and comparing with those of the Dynalyzer III which has been considered as a standard measuring device. From measuring the tube current accuracy depending on changes in tube voltage and exposure time, the clamp meter showed higher accuracy rate which was -1.3~4.2% difference. Thus clamp meter can be used for clinical radiologists who are not familiar electric circuit to manage X-ray devices easily and correctly in the future.

Measurement of High Voltage and Large Current Pulse Using Laser System (레이저를 이용한 펄스형 고전압 및 대전류 측정)

  • Lee, Yoon-Seok;Chang, Yong-Moo;Kim, Jung-Tae;Koo, Ja-Yoon;Kang, Hyung-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.314-317
    • /
    • 1991
  • The waveforms of high voltage and current pulse were measured using laser measuring systems. Existing potential transformer and current transformer have low measuring precision because of resonance phenomena and waveform distortion due to the magnetic saturation. But using laser measurement, it is possible to obtain clear waveforms which have no effect of distortion and harmonic resonances. And electromagnetic interferences (EMI) in the measuring of high voltage and current pulse, but the optical measuring systems are not subjet to the influence of EMI. Using laser measuring systems based upon Pockels effect and Faraday effect is not free from any errors yet, but it could replace existing measuring systems by routine experiments and error corrections. And it needs that more research and development of optical crystals and equipments would be taken.

  • PDF

A Current Collection Performance On-line Test Plan in Korea High Speed Train Development Project (고속전철 기술개발사업 본선 시운전 집전시험계획)

  • 조용현;최강윤;백광선
    • Proceedings of the KSR Conference
    • /
    • 2001.10a
    • /
    • pp.156-162
    • /
    • 2001
  • Current collection performance on-line tests for a Korean High Speed Train being developed in G7 project is scheduled to start in June, 2002. In this paper, preparatory efforts for measuring contact forces which is regarded as one of major measuring items in the test are introduced. Specifically speaking, review of frequencies related with contact force fluctuations, brief of contact force measuring algorithm, review of measuring instrument specifications and development of a data acquisition program are presented.

  • PDF

Factors Affected the Accuracy of Lightning Current Measuring System (뇌격전류 측정의 정확도에 영향을 미치는 요인)

  • Lee, B.H.;Chang, K.C.;Kang, S.M.;Eom, J.H.;Jeong, K.J.;Sim, E.B.;Woo, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1674-1676
    • /
    • 2003
  • The factors affecting the accuracy of lightning current measuring system are figured out the materials and length of down-conductor, and impedance matching between grounding resistance and characteristic impedance of cable. The cable with the low characteristic impedance used to transfer the lightning current from the top of the tower is too long to measure the waveform of lightning current, exactly. Especially, the height of the tower can cause the change of front time and magnitude of lightning stroke current. Basically, in this experiment. It was found that the magnitude and rise time of the lightning current are extremely dependant in the length of down-conductor in lightning current measuring system.

  • PDF

Junction, Circuit and System Developments for a High-Tc Superconductor Sampler

  • Hidaka, M.;Satoh, T.;Tahara, S.
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.13-15
    • /
    • 1999
  • A Josephson sampler circuit using high-Tc superconductor (HTS) ramp-edge junctions has been designed, fabricated, and experimentally tested. It consists of five ramp-edge junctions with a stacked groundplane and is based on single-flux-quantum (SFQ) operations. The sampler was used to measure current waveforms at picosecond and microampere resolutions. We are developing a system based on the sampler for measuring the current waveform in a room-temperature sample. And measuring current flowing through wiring in a semiconductor large-scale integrated circuit is a promising application for the HTS sampler system.

  • PDF

Junction, Circuit and System Developments for a High-$T_c$ Superconductor Sampler

  • Hidaka, M.;Satoh, T.;Tahara, S.
    • Progress in Superconductivity
    • /
    • v.1 no.2
    • /
    • pp.81-84
    • /
    • 2000
  • A Josephson sampler circuit using high-Tc superconductor (HTS) ramp-edge junctions has been designed, fabricated, and experimentally tested. It consists of five ramp-edge junctions with a stacked groundplane and is based on single-flux-quantum (SFQ) operations. The sampler was used to measure current waveforms at picosecond and microampere resolutions. We are developing a system based on the sampler for measuring the current waveform in a room-temperature sample. And measuring current flowing through wiring in a semiconductor large-scale integrated circuit is a promising application for the HTS sampler system.

  • PDF

A Development of the High Precise Measuring Device and Methods of Resistive Leakage Current for the Deterioration Diagnosis of ZnO Arrester (산화아연 피뢰기의 열화진단을 위한 저항성누설전류의 고정도 측정기법 및 장치의 개발)

  • Lee, B.H.;Kang, S.M.;Jeon, D.K.;Park, K.Y.;Choi, H.S.;Cho, S.C.;Baek, Y.H.;Lee, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1668-1670
    • /
    • 2003
  • This paper deals with a development of the high precise measuring device of resistive leakage current for the deterioration and diagnosis of ZnO arresters. The resistive leakage current increasing with time leads to a thermally unstable state that may even experience a disaster. So, the resistive leakage current can be used as an indicator to discriminate whether the ZnO arrester blocks is in good state or in bad. The resistive leakage current measuring system with an analysis program operated with micro-processor using the time delay addition method was designed and fabricated. The proposed measuring systems for the resistive leakage current can effectively be used to develop the techniques of forecasting the deterioration of ZnO arresters in electric power systems.⨀ᔌ?؀㔳㤮㈻Ԁ䭃䑎䷗ᜒं6〰Ԁ䭃䑎䴀

  • PDF

Temporary calibration procedures for high-current measuring system (대전류 측정시스템에 대한 잠정적 교정절차)

  • Shin, Y.J.;Kim, I.K.;Kim, M.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.440-442
    • /
    • 2001
  • Calibration procedure of high-current measuring system has been promoted to ensure the traceability of national of international standard with the similar method of high-voltage measuring system. This paper introduces general procedure to establish the traceability and type & performance tests for current-voltage transformer, transmission system, recorder and evaluation procedure as the result of intercomparison tests performed 7 laboratories of Europe, and introduces briefly the test method of itemized list from type & performance tests. So we would apply the standard as the criteria that can be enforced temporarily in korea.

  • PDF

Research of an On-Line Measurement Method for High-power IGBT Collector Current

  • Hu, Liangdeng;Sun, Chi;Zhao, Zhihua
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.362-373
    • /
    • 2016
  • The on-line measurement of high-power IGBT collector current is important for the hierarchical control and short-circuit and overcurrent protection of its driver and the sensorless control of the converter. The conventional on-line measurement methods for IGBT collector current are not suitable for engineering measurement due to their large-size, high-cost, low-efficiency sensors, current transformers or dividers, etc. Based on the gate driver, this paper has proposed a current measuring circuit for IGBT collector current. The circuit is used to conduct non-intervention on-line measurement of IGBT collector current by detecting the voltage drop of the IGBT power emitter and the auxiliary emitter terminals. A theoretical analysis verifies the feasibility of this circuit. The circuit adopts an operational amplifier for impedance isolation to prevent the measuring circuit from affecting the dynamic performance of the IGBT. Due to using the scheme for integration first and amplification afterwards, the difficult problem of achieving high accuracy in the transient-state and on-state measurement of the voltage between the terminals of IGBT power emitter and the auxiliary emitter (uEe) has been solved. This is impossible for a conventional detector. On this basis, the adoption of a two-stage operational amplifier can better meet the requirements of high bandwidth measurement under the conditions of a small signal with a large gain. Finally, various experiments have been carried out under the conditions of several typical loads (resistance-inductance load, resistance load and inductance load), different IGBT junction temperatures, soft short-circuits and hard short-circuits for the on-line measurement of IGBT collector current. This is aided by the capacitor voltage which is the integration result of the voltage uEe. The results show that the proposed method of measuring IGBT collector current is feasible and effective.