• 제목/요약/키워드: High Voltage Generator

검색결과 575건 처리시간 0.026초

발전기 회전자 턴단락 센서 국산화 개발에 관한 연구 (Development of Shorted-Turn Sensor for Generator Rotor Windings)

  • 이영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2050-2051
    • /
    • 2007
  • As a fundamental investigation to develop a sensor which is able to detect shorted turn phenomenon of generator rotor, we have experimented with self-made sensor using flux generator and high-resolution oscilloscope. We have recorded sensor-induced voltage according to the different condition, such as variations of turn, diameter and length of sensor. Based on the acquired data, we analyzed and simulated under similar circumstances of actual spot to maximize reliability. We have a plan to invest more resources to supply power plants with the developed sensor for ourselves.

  • PDF

초음파 모터 구동용 발진회로의 설계 및 제작 (Design and fabrication of driving generator for ultrasonic motors)

  • 심성훈;백동수;윤석진;김현재
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.129-131
    • /
    • 1999
  • Driving generator of USMs(ultrasonic motors) with low noise, high efficiency was designed and fabricated. It was focused on merits such as size-reduction, thermal resistance, To control revolution speed, input frequency was varied. Output of generator had frequency range of 39.1 ∼ 43.5 MHz and voltage of 120 V. USM with resonant frequency 40.3 kHz exhibited a maximum torque of 2.5 kg $.$ cm and a maximum revolution speed of about 130 rpm.

  • PDF

저전압 DRAM용 VPP Generator 설계 (A VPP Generator Design for a Low Voltage DRAM)

  • 김태훈;이재형;하판봉;김영희
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 추계종합학술대회
    • /
    • pp.776-780
    • /
    • 2007
  • 본 논문에서는 저전압 DRAM용 VPP Generator의 전하펌프회로(Charge Pump Circuit)를 새롭게 제안하였다. 제안된 전하펌프회로는 2-Stage 크로스 커플 전하펌프회로(Cross-Coupled Charge Pump Circuit)이다. 4개의 비중첩 클럭신호들을 이용하여 전하전달 효율을 향상시켰고, 각 전하펌프단 마다 Oscillation 주기를 줄일 목적으로 Distributed Clock Driver인 Inverter 4개를 추가하여 펌핑전류(Pumping Current)를 증가시켰다. 그리고 전하전달 트랜지스터의 게이트단에 프리차지회로 (Precharge Circuit)를 두어 대기모드진입 시 펌핑된 전하를 방전하지 못하고 고전압을 유지하여 소자의 신뢰성을 떨어트리는 문제를 해결하였다. 모의실험결과 펌핑전류, 펌핑효율(Pumping Efficiency), 파워효율(Power Efficiency) 모두 향상된 것을 확인하였고, $0.18{\mu}m$ Triple-Well 공정을 이용하여 Layout 하였다.

  • PDF

전자방사식 고압 저전력 방전을 이용한 OH radical 발생기의 개발과 성능 평가 (Development and Performance Evaluation of Hydroxyl Radical Generator using Electron Emission Type High Voltage and Low Current Discharger)

  • 강형섭;홍영표;이인호;김기범
    • 한국산학기술학회논문지
    • /
    • 제18권6호
    • /
    • pp.558-566
    • /
    • 2017
  • 본 연구는 MOSFET을 이용하여 안정적인 구형파를 구현함과 동시에 순간적인 전류의 상승을 최대한 줄여 전체 회로의 안정성 이 확보된 폐수처리용 전자방사식 OH radical generator를 개발하고자 하였다. 이와 같은 문제를 해결하고 안정성이 확보된 전자방사식 고압 저전력 방전을 이용한 폐수처리용 전자방사식 OH radical generator를 개발하고 그 성능을 평가하고자 하였다. 실험은 2016년 11월부터 2017년 3월까지 실시하였다. 그 결과 AC 체배 변환기의 입력 단에 연결되는 Power MOSFET의 drain 전류는 CR-스너버 구조의 부궤환(negative feedback) 회로를 통해 안정적이고 일정한 펄스 파형을 제공할 수 있었으며 AC 체배 변환기의 여기 전류(excitation current) 감소 및 발진 회로의 안정성을 상승시킬 수 있었다. 또한 이와 같은 회로를 갖는 전자방사식 OH radical generator에서 OH radical을 안정정적으로 발생시킬 수 있었다. 또한 살균능을 평가한 결과, E. coli, S. aureus와 S. flexneri는 60분 후 최대 99.9%이상의 살균력을 보였다. 본 연구 결과를 기반으로, MOSFET을 이용하여 안정적인 구형파를 구현함과 동시에 순간적인 전류의 상승을 최대한 줄여 전체 회로의 안정성이 확보된 살균능이 우수한 폐수처리용 전자방사식 OH radical generator를 개발하였다.

병렬 또는 직렬로 결합한 나선형 자장압축발전기의 출력특성 분석 (Output Characteristics of Parallel or Serially Connected Helical Magneto-Cumulative Generators)

  • 국정현;이흥호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권11호
    • /
    • pp.647-657
    • /
    • 2004
  • Helical magneto-cumulative generator(HMCG)s are very useful devices in suppling pulsed high current to inductance loads. To apply fast high voltage pulses to high impedance loads, high current outputs of HMCGs are required to be conditioned to higher voltages by using various pulse components such as opening/closing switches and pulse transformer. In this paper, stepping with the trends of requirements for ever-increasing energy in pulsed power applications coupling methods is investigated to obtain higher output energy by connecting several HMCGs in series or parallel way. The coil dimension of HMCGs used in series or parallel connections was 50 mm in diameter and 150 mm in length. The coil was fabricated by using enamel-coated copper wire of 1 mm in diameter. The highest energy amplification ratio and peak voltage of load were achieved from the serially connected four-barrel HMCG system. They were 68 and 34 kV, respectively, when the initial energy of 0.36 kJ was supplied into that system with the load of 0.4 μH. Within the tested range of inductance ratio, energy amplification ratio was found to be highly dependent on the inductance ratio of serial- and parallel-connected HMCG systems to load, which to be optimal around 500 was turned out. The experimental results showed that the output energy and voltage of load are controlled by connecting HMCGs in series or parallel.

전파정류방식의 고전압발생장치를 이용한 X선 기기의 특성 평가 (Characteristic Analysis of X-ray Device using the High Voltage Generator on Full-wave Rectification Method)

  • 김영표;김태곤;이호식;박용필;천민우
    • 한국전기전자재료학회논문지
    • /
    • 제22권6호
    • /
    • pp.516-521
    • /
    • 2009
  • X-ray system which is usefully used in diagnosis of the patient, being bombed of radioactivity is a big weak point when irradiates a X-ray to the human body so that ICRP restricted the radiation exposure tolerance of the human body. In order to reduce being bombed, the many research and development is now advanced. A lots of diagnostic X-ray machines have currently used due to the increase of occurrence efficiency of X-ray and precisely the output control by using the inverter which is a high speed switching semiconductors. For getting the confidence of the X-ray machine, the same radiation occurrence, same evaluation, and same irradiation condition are necessary when evaluates X-ray irradiation. It is the most important part for the accuracy of the test result and the patient safety. This research has produced the high voltage occurrence system of full-wave rectification method by using the LC resonance inverter, and evaluated the irradiation reproducibility in order to use it in diagnosis of the patient.

도깨비봉형 오존발생장치이 펄스커로나 방전에 의한 오존 발생 특성 (High Efficiency Ozone Generation Using a Pyramid-Project-Embossed Rod-to-Cylinder Electrode and a Pulse Corona Discharge)

  • 문재덕;이근택
    • 대한전기학회논문지
    • /
    • 제38권8호
    • /
    • pp.650-657
    • /
    • 1989
  • The conversion efficiency of an ozone generator can be significantly improved by modifying the discharge electrode of a helical strip line rod-to-cylinder type ozone generator to a pyramid-project-embossed rod, and by using a pulse corona discharge. Parametric studies have been carried out to obtain optimum values of peak pulse voltage, pulse forming capacitance, feeder cable and ozone generator capacitance, interelectrode spacing and corona tip density of ozone generator, and feed air flow rate and temperature. The generated ozone concentration was very dependent upon the value of pulse forming capacitance, feeder cable and ozone generator capacitance, and corona tip density. Maximum conversion efficiency was obtained with a pulse forming capacitance of about 500pF, 75pF matched feeder cable and ozone generator, and a corona tip density of 16mm. When operated at optimum values, ozone yield of 79, 99, 80 g/KWh for the different interelectrode type ozone generators tested were obtained, which are approximately 30% higher than that of an industrial ozone generator.

  • PDF

배전용 변압기를 통한 저압전원선으로의 뇌서지 전파 (Propagation of Lightning Surges on Power AC Lines through Distribution Transformers)

  • 이복희;이수봉;이동문
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.468-471
    • /
    • 2002
  • A strong need to improve the quality of electric power is increased because of increasing use of the sensitive and small-sized electronic devices. The surges on the low-voltage ac power lines are induced by nearby lightning return strokes, and the facilities for HA, OA, FA, ME as well as computer are easily damaged by high-voltage transients. The behaviors of lightning surge characteristics transferred from the primary winding to the secondary winding in distribution transformers using a Marx generator were experimentally investigated. The transfer characteristics of lightning surge associated with a custom service ground of secondary side were also examined.

  • PDF

A Novel Three-Phase Four-Wire Grid-Connected Synchronverter that Mimics Synchronous Generators

  • Tan, Qian;Lv, Zhipeng;Xu, Bei;Jiang, Wenqian;Ai, Xin;Zhong, Qingchang
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2221-2230
    • /
    • 2016
  • Voltage and frequency stability issues occur in existing centralized power system due to the high penetration of renewable energy sources, which decrease grid absorptive capacity of them. The grid-connected inverter that mimics synchronous generator characteristics with inertia characteristic is beneficial to electric power system stability. This paper proposed a novel three-phase four-wire grid-connected inverter with an independent neutral line module that mimics synchronous generators. A mathematical model of the synchronous generator and operation principles of the synchronverter are introduced. The main circuit and control parameters design procedures are also provided in detail. A 10 kW prototype is built and tested for further verification. The primary frequency modulation and primary voltage regulation characteristics of the synchronous generator are emulated and automatically adjusted by the proposed circuit, which helps to supports the grid.

전류제어형 PWM컨버터를 이용한 동기발전기용 여자시스템에 관한 연구 (A Study on Excitation System for Synchronous Generator using Current Mode Controlled PWM Converter)

  • 장수진;류동균;서민성;김준호;원충연;이진국
    • 조명전기설비학회논문지
    • /
    • 제17권3호
    • /
    • pp.32-39
    • /
    • 2003
  • 동기발전기 출력전압은 여자시스템의 계자전류 제어에 의해 일정하게 유지된다. 고주파 PWM 컨버터(전류제어 모드 buck 컨버터) 형태의 여자시스템은 부하변동이 발생하였을 때 동기발전기의 계자전류를 제어하게 된다. 이 논문은 정상상태 및 과도상태에서의 안정화를 개선하기 위하여 여자시스템의 설계 및 실험에 대해 다루었다. 시뮬레이션 및 실험 결과는 제안된 여자시스템이 50[kW] 동기발전기의 DVR에 의해 응답시간이 개선되었음을 보여주었다.