• Title/Summary/Keyword: High Velocity Impact

Search Result 441, Processing Time 0.035 seconds

Analysis of Hypervelocity Impact Fracture Behavior of Multiple Bumper Steel Plates (다층 강재 방호판의 초고속 충격 파괴거동해석)

  • Jo, Jong Hyun;Lee, Young Shin;Kim, Jae Hoon;Bae, Yong Woon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.6
    • /
    • pp.761-768
    • /
    • 2013
  • New warheads are designed and developed to be highly lethal when used as part of ballistic missile payloads. There are many trades associated with the design of a central warhead core, mainly dealing with the projectiles or penetrators. Obviously, a payload-type configuration is very susceptible to kills from one projectile because of the high impacts required for bomblet or submunition payloads. Based on these requirements, the optimum kill vehicle configuration will have the smallest mass and relative velocity that will kill all the submunitions. The designs of the penetrator shape and size are directly related to the space and weight of the warhead. The shape, size, L/D, penetrator material, and manner in which they are inserted inside the surrounding explosive segments are critical in achieving successful penetrator design. The AUTODYN-3D code was used to study the effect of penetrator penetration. The objective of numerical analysis was to determine the penetration characteristics of the penetrator produced by hypervelocity impacts under different initial conditions such as initial velocity, shape, and L/D of the penetrator.

Evaluation of Microcracks in Thermal Damaged Concrete Using Nonlinear Ultrasonic Modulation Technique (비선형 초음파 변조 기법을 이용한 열손상 콘크리트의 미세균열 평가)

  • Park, Sun-Jong;Yim, Hong Jae;Kwak, Hyo-Gyung
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.651-658
    • /
    • 2012
  • This paper concentrates on the evaluation of microcracks in thermal damaged concrete on the basis of the nonlinear ultrasonic modulation technique. Since concrete structure exposed to high temperature accompanies the development of microcracks due to the physical and chemical changes from temperature and exposed time, the adoption of nonlinear approach is required. Instead of using the conventional ultrasonic nondestructive methods which have the limitation in evaluating excessive microcracks, accordingly, a nonlinear ultrasonic modulation method which shows better sensitivity in quantifying microcracks is introduced. Upon the analysis for the modulation of ultrasonic wave and low frequency impact to measure the nonlinearity parameter, which can be used as an indicator of thermal damage, the verification processes for the introduced technique are followed: SEM investigation and permeable pore space test are performed to characterize thermally induced microcracks in concrete, and ultrasonic pulse velocity tests are performed to confirm the outstanding sensitivity of nonlinear ultrasonic modulation technique. In advance, compressive strength of thermal damaged concrete is measured to represent the effect of microcracks on performance degradation. Correlation studies between experimental data and measured data show that nonlinear ultrasonic modulation technique can effectively be used to quantify thermally induced microcracks, and to estimate the compressive strength of thermally damaged concrete.

A study on the action mechanism of internal pressures in straight-cone steel cooling tower under two-way coupling between wind and rain

  • Ke, S.T.;Du, L.Y.;Ge, Y.J.;Yang, Q.;Wang, H.;Tamura, Y.
    • Wind and Structures
    • /
    • v.27 no.1
    • /
    • pp.11-27
    • /
    • 2018
  • The straight-cone steel cooling tower is a novel type of structure, which has a distinct aerodynamic distribution on the internal surface of the tower cylinder compared with conventional hyperbolic concrete cooling towers. Especially in the extreme weather conditions of strong wind and heavy rain, heavy rain also has a direct impact on aerodynamic force on the internal surface and changes the turbulence effect of pulsating wind, but existing studies mainly focus on the impact effect brought by wind-driven rain to structure surface. In addition, for the indirect air cooled cooling tower, different additional ventilation rate of shutters produces a considerable interference to air movement inside the tower and also to the action mechanism of loads. To solve the problem, a straight-cone steel cooling towerstanding 189 m high and currently being constructed is taken as the research object in this study. The algorithm for two-way coupling between wind and rain is adopted. Simulation of wind field and raindrops is performed with continuous phase and discrete phase models, respectively, under the general principles of computational fluid dynamics (CFD). Firstly, the rule of influence of 9 combinations of wind sped and rainfall intensity on flow field mechanism, the volume of wind-driven rain, additional action force of raindrops and equivalent internal pressure coefficient of the tower cylinder is analyzed. On this basis, the internal pressures of the cooling tower under the most unfavorable working condition are compared between four ventilation rates of shutters (0%, 15%, 30% and 100%). The results show that the 3D effect of equivalent internal pressure coefficient is the most significant when considering two-way coupling between wind and rain. Additional load imposed by raindrops on the internal surface of the tower accounts for an extremely small proportion of total wind load, the maximum being only 0.245%. This occurs under the combination of 20 m/s wind velocity and 200 mm/h rainfall intensity. Ventilation rate of shutters not only changes the air movement inside the tower, but also affects the accumulated amount and distribution of raindrops on the internal surface.

Impact of the lateral mean recirculation characteristics on the near-wake and bulk quantities of the BARC configuration

  • Lunghi, Gianmarco;Pasqualetto, Elena;Rocchio, Benedetto;Mariotti, Alessandro;Salvetti, Maria Vittoria
    • Wind and Structures
    • /
    • v.34 no.1
    • /
    • pp.115-125
    • /
    • 2022
  • The high-Reynolds number flow around a rectangular cylinder, having streamwise to crossflow length ratio equal to 5 is analyzed in the present paper. The flow is characterized by shear-layer separation from the upstream edges. Vortical structures of different size form from the roll-up of these shear layers, move downstream and interact with the classical vortex shedding further downstream in the wake. The corresponding mean flow is characterized by a recirculation region along the lateral surface of the cylinder, ending by mean flow reattachment close to the trailing edge. The mean flow features on the cylinder side have been shown to be highly sensitive to set-up parameters both in numerical simulations and in experiments. The results of 21 Large Eddy Simulations (LES) are analyzed herein to highlight the impact of the lateral mean recirculation characteristics on the near-wake flow features and on some bulk quantities. The considered simulations have been carried out at Reynolds number Re=DU_∞/ν=40 000, being D the crossflow dimension, U_∞ the freestream velocity and ν the kinematic viscosity of air; the flow is set to have zero angle of attack. Some simulations are carried out with sharp edges (Mariotti et al. 2017), others with different values of the rounding of the upstream edges (Rocchio et al. 2020) and an additional LES is carried out to match the value of the roundness of the upstream edges in the experiments in Pasqualetto et al. (2022). The dimensions of the mean recirculation zone vary considerably in these simulations, allowing us to single out meaningful trends. The streamwise length of the lateral mean recirculation and the streamwise distance from the upstream edge of its center are the parameters controlling the considered quantities. The wake width increases linearly with these parameters, while the vortex-shedding non-dimensional frequency shows a linear decrease. The drag coefficient also linearly decreases with increasing the recirculation length and this is due to a reduction of the suctions on the base. However, the overall variation of C_D is small. Finally, a significant, and once again linear, increase of the fluctuations of the lift coefficient is found for increasing the mean recirculation streamwise length.

Evaluation of Runoff Loads and Computing of Contribute ratio by First Flush Stormwater from Cheongyang-Hongseong Road (청양-홍성간 도로에서의 초기강우에 의한 유출부하량 평가 및 기여율 산정)

  • Lee, Chun-Won;Kang, Seon-Hong;Choi, I-Song;An, Tae-Ung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.407-417
    • /
    • 2011
  • Nowadays, the high land use, mainly used for urbanization, is affecting runoff loads of non-point pollutants to increase. According to this fact, increasing runoff loads seems like to appear that it contributes to high ratio of pollution loads in the whole the pollution loads and that this non-point source is the main cause of water becoming worse quality. Especially, concentrated pollutants on the impermeable roads run off to the public water bodies. Also the coefficient of runoff from roads is high with a fast velocity of runoff, which ends up with consequence that a lot of pollutants runoff happens when it is raining. Therefore it is very important project to evaluate the quantity of pollutant loads. In this study, I computed the pollutant loadings depending on time and rainfall to analyze characteristics of runoff while first flush storm water and evaluated the runoff time while first flush storm water and rainfall based on the change in curves on the graph. I also computed contribution ratio to identify its impact on water quality of stream. I realized that the management and treatment of first flush storm water effluents is very important for the management of road's non-point source pollutants because runoff loads of non-point source pollution are over the 80% of whole loads of stream. Also according to the evaluation of runoff loads of first flush storm water for SS, run off time was shown under the 30 minute and rainfall was shown under the 5mm which is less than 20% of whole rainfall. These are under 5mm which is regarded amount of first flush storm water by the Ministry of Environment and it is judged to be because run off by rainfall is very fast on impermeable roads. Also, run off time and rainfall of BOD is higher than SS. Therefore I realized that the management of non-point source should be managed and done differently depending on each material. Finally, the contribution ratio of pollutants loads by rainfall-runoff was shown SS 12.7%, BOD 12.7%, COD 15.9%, T-N 4.9%, T-P 8.9%, however, the pollutants loads flowing into the steam was shown 4.4%. This represents that the concentration of non-point pollutants is relatively higher and we should find the methodical management and should be concerned about non-point source for improvement on water quality of streams.

Suggestion on the Optimal Length of Long Tunnels Considering Traffic Safety Characteristics (교통안전 특성을 고려한 장대터널 적정길이 제시)

  • Kim, Joong-Hyo;Lee, Jeong-Hwan;Kwon, Sung Dae;Ha, Dong Ik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.203-211
    • /
    • 2014
  • Tunnel reduces travel time as and it is essential facilities for the eco-friendly road construction. In recent years, It has been accelerating the tunnel construction to provide a higher level of traffic service but a driver driving in the narrow and dark tunnel takes characteristically psychological anxiety and the restriction of the sight. Moreover, A driver passing through more than 1,000m long tunnel, as to pass inside the monotonous form of the tunnel for a long time can cause drowsiness and increase the driver load. This driver load can degrade road-holding of the inside of the long tunnel highly and pose a high risk of accidents. Accordingly, In this study is to present the proper length of the Tunnel, considering the characteristics of traffic accident. For this, this study is that the long tunnel that affects traffic safety traffic safety variables are selected and classified. Traffic safety variables are classified in detail as a variable of the traffic accident and velocity one, the applicable variables the number of the traffic accident, the ratio of the traffic accident, driving velocity, the individual vehicle velocity etc. Traffic safety variables are categorized as more than a pole length of the tunnel in order to examine its impact on correlation analysis. The results indicate significant results in traffic accidents in accordance with traffic accidents, traffic safety, selects the variable was Variable depending on the length of the tunnel traffic safety point of significantly increasing the possibility of an accident can be seen as a high point. And the point of the Distribution of selected variables in order to create a traffic safety was a significant increase in traffic safety variables was set at critical intervals. Before reaching the critical point and the corresponding length of the long tunnel was set at the proper length. In this study, the optimum length of the proposed long tunnel through the long tunnel that occur in the future to contribute to reducing traffic accidents would be able to be determined.

Slug Characteristics in a Bubbling Fluidized Bed Reactor for Polymerization Reaction (기포유동층 고분자 중합 반응기에서의 슬러그 특성)

  • Go, Eun Sol;Kang, Seo Yeong;Seo, Su Been;Kim, Hyung Woo;Lee, See Hoon
    • Korean Chemical Engineering Research
    • /
    • v.58 no.4
    • /
    • pp.651-657
    • /
    • 2020
  • Fluidization processes in which solid particles vividly move like gas or liquid have been widely used in various industrial sectors, such as thermochemical energy conversion and polymerization processes for general purpose polymer resins. One of the general purpose polymer resins, LLDPE(Linear low-density polyethylene) resins have been produced in bubbling fluidized bed processes in the world. In a bubbling fluidization polymerization reactors, LLDPE particles with relatively larger particle size and low density are fluidized by hydrogen gas for polymerization reaction. Though LLDPE polymerization reactors are one of bubbling fluidization processes, slugs that have negative impact for reaction exist or occur in these processes. Therefore, the fluidization state of LLDPE particles was investigated in a simulation model similar to a pilot-scale polymerization reactor (0.38 m l.D., 4.4 m High). In particular, the effect of gas velocity (0.45-1.2 m/s), solid density (900-199 kg/㎥), solid sphericity (0.5-1.0), and average particle size (120-1230 ㎛), on bed height and fluidization state were measured by using a CPFD(Computational particle-fluid dynamics) method. With CPFD analysis, the occurrence of a flat slug was visualized. Also, the change in particle properties, such as particle density, sphericity, and size, could reduce the occurrence of slug and bed expansion.

Proposal of Prediction Technique for Future Vegetation Information by Climate Change using Satellite Image (위성영상을 이용한 기후변화에 따른 미래 식생정보 예측 기법 제안)

  • Ha, Rim;Shin, Hyung-Jin;Kim, Seong-Joon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.10 no.3
    • /
    • pp.58-69
    • /
    • 2007
  • The vegetation area that occupies 76% in land surface of the earth can give a considerable impact on water resources, environment and ecological system by future climate change. The purpose of this study is to predict future vegetation cover information from NDVI (Normalized Difference Vegetation Index) extracted from satellite images. Current vegetation information was prepared from monthly NDVI (March to November) extracted from NOAA AVHRR (1994 - 2004) and Terra MODIS (2000 - 2004) satellite images. The NDVI values of MODIS for 5 years were 20% higher than those of NOAA. The interrelation between NDVIs and monthly averaged climate factors (daily mean, maximum and minimum temperature, rainfall, sunshine hour, wind velocity, and relative humidity) for 5 river basins of South Korea showed that the monthly NDVIs had high relationship with monthly averaged temperature. By linear regression, the future NDVIs were estimated using the future mean temperature of CCCma CGCM2 A2 and B2 climate change scenario. The future vegetation information by NOAA NDVI showed little difference in peak value of NDVI, but the peak time was shifted from July to August and maintained high NDVIs to October while the present NDVI decrease from September. The future MODIS NDVIs showed about 5% increase comparing with the present NDVIs from July to August.

  • PDF

Development and Application of Anti-Corrosive Steel Using Electro-Deposition of Sea Water (2)- Evaluation of Application Rebar with Electro-Deposition Using Sea Water (해수전착 코팅을 이용한 내부식성 철근의 개발 및 적용성에 대한 연구 (2) -해수전착된 구조용 철근의 적용성 평가)

  • Kwon, Seung Jun;Lee, Sang Min;Park, Sang Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.155-162
    • /
    • 2012
  • When RC (Reinforced Concrete) structures are exposed to sea water, steel corrosion can occur and this leads a degradation of structural performance. Referring the electro-deposition system with sea water from the 1st step research, durability and structural performance are evaluated in coated steel and RC members containing it in the 2nd research. In the durability performance test, Half Cell Potential test is performed and the coated steel is evaluated to have the high resistance to corrosion, which shows only 35% of corrosion velocity in normal (bare) steel. In the structural performance test, tensile strength, adhesive strength, and flexural/shear in RC member are performed. For the electro-deposit coated steel, increasing ratios of 3.2% and 8.8% are evaluated in the test of tensile strength and adhesive strength, respectively. For the structural test in RC member, there is no big difference between RC members with coated and non-coated steel in ultimate load and failure pattern It is evaluated that the chemical compound with $CaCO_3$ and $Mg(OH)_2$ from electro-deposition causes slightly increased structural performance. The electro-deposit coated steel can be more widely applied after performance verification from several tests like fatigue, resistance to impact, and long term-submerging test.

The Study on the Prediction of Algae Occurrence by the Multiple Regression Analysis After Weir Construction at Namhan River (다중회귀분석을 이용한 남한강 내 보 건설 후 조류 발생량 예측)

  • Oh, Seung-Eun;Ahn, Hong-Kyu;Chae, Soo-Kwon
    • Journal of Environmental Impact Assessment
    • /
    • v.26 no.6
    • /
    • pp.470-478
    • /
    • 2017
  • This study was classified into two groups, normal season group and drought season group, by the cluster analysis using the weather and water quality data from 2012 to 2015, using SPSS 18 version. Also each cluster was classified into three spaces, Gangcheon, Yeoju and Ipoh weir. We performed the multiple regression analysis with each monthly data that concentration of Chl-a was more than algae warming level. 6 groups classified in time and space were analyzed by the correlation analysis between concentration of Chl-a and 3 weather, 11 water quality and discharge factors. We developed Chl-a prediction equations of each group with independent variables of the multiple regression analysis applying to the correlation result. The result of cluster analysis was that the period was divided into two groups, normal group(2012-2013) that total annual precipitation rate was normal and drought group(2014-2015) that total annual precipitation rate was less than 1,000 mm/hr, in time. The months that concentration of Chl-a was more than algae warming level in each group classified by cluster analysis were that the normal group was 3~8 and drought group was 3 and 6~10. The correlation result between Chl-a and weather, water quality and discharge factors for each 6 group was that relationships between Chl-a and water, discharge factors were high in the drought group more than in normal group at all weirs. This was influenced by velocity reduction and increasing HRT according to the intense drought. Weather, water quality and discharge factors that were high correlation with Chl-a were applied to independent variables of Chl-a prediction equations and each equations were developed. Among them, Each adjusted R square of Prediction equations for Chl-a in each group at Ipoh weir where is located in Namhan river downstream and is directly connected to Paldang dam were normal group = 0.920 and drought group = 0.818. It's showed the high linear.