• Title/Summary/Keyword: High Power LED

Search Result 603, Processing Time 0.031 seconds

Power conversion control for zero emission buildings (탄소제로 빌딩을 위한 전력변환 제어)

  • Han, Seok-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.504-505
    • /
    • 2011
  • Decreasing actual greenhouse gas will be difficult if it is not solved addressed in architectural fields. Zero emission building or zero energy building, maximize the efficiency of energy, which means the building can operate by their own renewable energy facility without any other supplying. To be a zero emission building, a building needs realization of high efficiency low energy consumption, construction of building its own energy production facilities and lastly a power grid connection. According to increasing of DC load about TV, LED lighting, computer, IT in building for living and business, it is expected the save of energy when the system of AC power distribution change into the system of DC power distribution. Renewable energy exists a big different rate produced by outside environment. When electrical power overproduce, it can supply for system. Otherwise, if electrical power produce less, it can receive supply from system. Send and receive power can lead to zero to annual standard. This paper shows the simulation about efficient control of power conversion which is related to DC power distribution of architecture and DC output of renewable energy by using L-type converter.

  • PDF

The Fabrication and Design of Driving Circuit for LCD panel using the high efficiency LED (고 효율 LED를 이용한 LCD 패널 구동회로의 설계 및 제작)

  • Ryu, Jang-Ryeol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.7
    • /
    • pp.3146-3151
    • /
    • 2012
  • For using them as a optical source of inspections equipment for LCD panel, the design ofexcellent backlight system, brightness uniformity and high power and good protection against heat is essential.In this paper, backlight system which is built in the 45 inch side emitting LCD backlight by LED arraystructure and driving circuit were designed and developed. After that, their performances were measured. Itshowed the luminance from 3,000 to 25,000[$cd/m^2$], the mean value x:0.3144, y:0.3076 of x-y chromaticity,dimming range of 27~515[$cd/m^2$], free flicker noise in the 80kHz and black level of 0.7~0.1[$cd/m^2$], thermaltest of cooling system in 20,000[$cd/m^2$] over values.

Measurement of Junction Temperature in High Power LED Module with Property Analysis of Single Package (단일 패키지의 특성 분석을 통한 고출력 발광 다이오드 모듈의 접합 온도 측정)

  • Lee, Se-IL;Kim, Woo-Young;Jeong, Young-Gi;Yang, Jong-Kyung;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.12
    • /
    • pp.973-977
    • /
    • 2010
  • The temperature of junction in LED affects the life time and performance. however, the measurement of junction temperature in module is very difficult. In this paper, to measure the junction temperature in LED module, optical and electrical properties is measured in single package in temperature from 25 [$^{\circ}C$] to 85 [$^{\circ}C$], and then junction temperature can is estimated in module with measuring the average voltage of single package. As results, the junction temperature of single package is measured the temperature of 61.2 [$^{\circ}C$] in ambient temperature, also, the junction temperature of LED module is measured the temperature of 72.5 [$^{\circ}C$] in ambient temperature.

Realization of Optical Measurement using White Source and Fourier-domain (고휘도 백색 LED 및 CCD Array Detector를 사용한 Fourier-Domain 방식의 광 계측 시스템 구현)

  • Kim, Kwang-Yoo;Lee, Jung-Rul;Eom, Jin-Seob
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.1
    • /
    • pp.25-30
    • /
    • 2008
  • In this study, the Fourier-Domain optical measurement system, which use a commercial high power white LED as a light source and a CCD linear-array as a detector is realized. The proposed system shows the axial measurement range over $125{\mu}m$ and the axial resolution below $1.24{\mu}m$. This system has the advantage of the cost effective and compact structure and also the better resolution than the existing technologies, which have a resolution above a few of ${\mu}m$ and use bulky and/or expensive broadband light sources.

Implementation of Smart Control System based on Intelligent Dimming with LEDs

  • Lee, Geum-Boon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.5
    • /
    • pp.127-133
    • /
    • 2016
  • In this paper, an intelligent dimming control system is designed and implemented with the human visual response function using CDS sensor, PIR sensor and temperature sensor, etc. The proposed system is designed to detect a moving object by PIR sensor and to control the LED dimming considering the human visual response. Also, the dimming of LED light can modulate on the app, and simultaneously control dimming in real-world environments with smart phone app. A high-temperature warning or a fire hazard information is transmitted to user's smart phone according to sensor values and Data graph are provided as part of data visualization. Connecting the hardware controller, the proposed intelligent smart dimming control system is expected to contribute to the power reduction interior LED, smart grid building and saving home combining with internet of things.

The Method of Reducing the Output Electrolytic Capacitance in Single Stage PFC flyback Converter (Single stage PFC flyback 컨버터의 전해커패시터용량저감기법)

  • Kim, Jin-Gu;Park, Chong-Yeon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.81-88
    • /
    • 2015
  • LED has been great attentions in lighting industry because of its long life-time, high efficiency, excellent light output characteristics. However, the life-time of the LED driving system is decreased because of the electrolytic capacitor which is used in the power conversion system for driving LED lighting. Therefore the capacitance reduction methods have been studied to replace an electrolytic capacitor with film or tantalum capacitor. This paper presents the Single stage PFC flyback converter with the simplified third harmonic current injection circuit to reduce output capacitance and the proposed system is theoretically analyzed and verified through the experiment.

A Study on Railroad Vehicle Lighting Environment (철도차량 조명 환경 연구)

  • Kang, Og-Goo;Jang, Woojin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.3
    • /
    • pp.178-182
    • /
    • 2014
  • This paper investigates the lighting environment of railway system which are mainly used in KTX, Saemaul and Mugunghwa. When lighting used in KTX such as fluorescent lamp and incandescence is being replaced with LED lamp, illumination load of each railroad vehicle has been compared. The comparison result shows that the reduction of power consumption is 43.34% before and after the change. Also it has been performed the economic evaluation.

Analysis of Junction Temperature Measurement in 20W Module for Street Lighting (20W 가로등 모듈의 접합온도 측정 분석)

  • Lee, Se-Il;Yang, Jong-Kyung;Kim, Nam-Goon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.163-163
    • /
    • 2010
  • 기존 LED의 접합온도 및 열저항은 PKG 단계에서 측정 가능 하였다. PKG에서의 접합온도 측정방식과 같은 방법으로 C사의 1W High Power LED XP2 20개를 직렬 연결하여 모듈을 구성한 20W 가로등 모듈에 대하여 접합온도를 측정 하였다. 측정결과 20W 가로등 모듈의 접합온도는 약 $61^{\circ}C$로 나타났다.

  • PDF

The Design of LED Module for Full-Color Display (Full-Color Display를 위한 LED Module의 Design)

  • 송유리;원창섭;최연석;임석준;안형근;한득영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.274-277
    • /
    • 1996
  • This paper describes the realization of the full-color to the degree of nearest white light by compounding high brightness Red, Green and Blue LEDs with appropriate proportional index. Once these three colors; red, green and blue are mixed, they are genearlly additive mixing and produce white light color contrasted to negative mixing. The luminous efficiency is defined as the product of the efficiency(lm/w), which indicates the degree of perceptual response by the human eye to unit energy(W) of light emitted by an active display devises and as the conversion efficiency of the device from electric power consumed to optical energy produced. We will deduce the each number of LEDs theoretically and design several shapes of LED displays for the full-color. Finally theoretical predictions will be compared with the measured data with different type of display designs.

  • PDF