Realization of Optical Measurement using White Source and Fourier-domain

고휘도 백색 LED 및 CCD Array Detector를 사용한 Fourier-Domain 방식의 광 계측 시스템 구현

  • 김광유 (강원대학교 전자공학과) ;
  • 이정렬 (강원대학교 산학협력중심대학 사업단) ;
  • 엄진섭 (강원대학교 전자공학과)
  • Published : 2008.01.25

Abstract

In this study, the Fourier-Domain optical measurement system, which use a commercial high power white LED as a light source and a CCD linear-array as a detector is realized. The proposed system shows the axial measurement range over $125{\mu}m$ and the axial resolution below $1.24{\mu}m$. This system has the advantage of the cost effective and compact structure and also the better resolution than the existing technologies, which have a resolution above a few of ${\mu}m$ and use bulky and/or expensive broadband light sources.

본 논문에서는 상용 고휘도 백색광 LED 및 CCD 어레이 검파기를 이용하여 Fourier-domain 방식의 광 계측기를 구현하였다. 제안된 기술의 축 방향 측정 거리 범위는 $125{\mu}m$이고, 축 방향 분해능은 $1.24{\mu}m$이다. 기존 시스템이 고가의 광대역 광원을 사용하면서도 분해능이 수 ${\mu}m$ 이상인 것에 비추어 볼 때, 본 시스템은 저가의 상용 LED와 CCD 어레이 검파기를 사용하여 구현되므로 소형이며 가격적인 면에서 유리하면서도 높은 분해능을 얻을 수 있다.

Keywords

References

  1. 김철중, '레이저 가공 및 광 계측의 산업적 활용,' 한국광학회 학계학술발표회논문집 제12회, pp. 96-103, 1995
  2. Y. Yasuno, V. D. Madjarova, S. Makita, M. Akiba, A. Morosawa, C. Chong, T. Sakai, Kin-pin Chan, M. Itoh, and T. Yatagai, 'Three- dimensional and high-speed swept-source optical coherence tomography for in vivo investigation of human anterior eye segments,' Optics Express vol. 13, no. 26, pp10652-10664, Dec. 2005 https://doi.org/10.1364/OPEX.13.010652
  3. J. T. Oh & B. M. Kim. 'Artifact removal in complex frequency domain optical coherence tomography with iterative least-square phase- shifting algorithm,' OSA, pp. 4157-4164, 2005
  4. W. G. Jeon and Y. S. Cho, 'An equalization technique for OFDM and MC-CDMA in a multipath fading channels,' in Proc. of IEEE Conf. on Acoustics, Speech and Signal Processing, pp. 2529-2532, Munich, Germany, May 1997
  5. M. Wojtkowski, T. Bajraszewski, P. Targowski and A. Kowalczyk, 'Real-time in vivo imaging by high-speed spectral optical coherence tomography,' Optics Letters vol. 28, pp1745-1747, 2003 https://doi.org/10.1364/OL.28.001745
  6. N. A. Nassif, B. Cense, B. H. Park, M. C. Pierce, S. H. Yun, B. E. Bouma, G. J. Tearney, T. C. Chen and J. F. de Boer, 'In vivo high- resolution video-rate spectral-domain optical coherence tomography of the human retina and optic nerve,' Optics Express vol. 12, pp367-376, 2004. https://doi.org/10.1364/OPEX.12.000367