• 제목/요약/키워드: High Performance Building

검색결과 1,830건 처리시간 0.026초

Structural Design of High-Rise Building in Toranomon-Azabudai Project (A Block)

  • Kazumasa, Okabe;Kai, Toyama;Takuya, Furuta;Jyunichi, Yamashita;Hiroki, Mukai;Takahiro, Goseki;Shingo, Masuda;Dai, Shimazaki;Yusuke, Miyagi;Yuji, Ozawa
    • 국제초고층학회논문집
    • /
    • 제11권3호
    • /
    • pp.157-170
    • /
    • 2022
  • This paper explains about structural planning and structural design of the high-rise building in Toranomon-Azabudai Project (A Block) which is now under construction. The building is about 330 meters high, has 4.2 aspect ratio, and the outline of the building has shallow curve. We adopted seismic response control structure. The building is a steel rigid frame structure with braces, and it has enough stiffness to obtain its primary natural period to be less than about seven seconds, in consideration of wind response, seismic response and inhabitability for the wind shaking. In terms of business continuity plan, the building has a high seismic performance; value of story drift angle shall be 1/150 or less and members of the building remain almost undamaged while or after a large earthquake. Active mass dumper shall be installed at the top of the building to improve inhabitability while strong wind is blowing.

Evaluating high performance steel tube-framed diagrid for high-rise buildings

  • Lee, Dongkyu;Ha, Taehyu;Jung, Miyoung;Kim, Jinho
    • Steel and Composite Structures
    • /
    • 제16권3호
    • /
    • pp.289-303
    • /
    • 2014
  • In recent, development of construction and design technology gives taller, larger and heavier steel framed structures. With the tendency of increasing high-rise building, this study is strongly related to structural system, one of significant components in structural design. This study presents an innovative structural system, with high performance steel material, diagrid. Its detail, structural analysis, and structural experiments are all included for the development of new structures.

고층건축물에서의 연돌효과에 따른 배연창의 배연성능에 관한 기초적 연구 (A Basical Study about Ventilation Performance of Natural Smoke Ventilators through Stack Effect in High-rise Building)

  • 김혜원;진승현;구인혁;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.54-55
    • /
    • 2017
  • The High-rise building has a problem the ventilation performance of natural ventilator by stack effect that it occurs by pressure difference. For that reason the study about natural smoke ventilator of High-rise building consistently needs. Therefore on this study does analysis of difference with abroad through investigate of Natrual smoke ventilator's law, it conducts of natural smoke ventilator's research on the actual condition. As a result on this study, in the case of abroad that it states more specific standards than domestic. Also the result of a field study, it shows that the natural smoke ventilator is installed same size and the number regardless of building's pressure difference.

  • PDF

초고층건축물의 화재안전설계를 위한 관련법령조사에 관한 연구 (A study on the survey Korea code research for fire safety design of high-rise building)

  • 김일권;서동구;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.232-233
    • /
    • 2013
  • Recently Korea has imported and executed Performance Based Design for the method to settle the dangerousness on outbreak of fire of high-rise building. The overseas country's PBD is autonomic but It is unable to carry out the essential role of PBD as the performance based design that based the code based design in the domestic. Also It occurs the problems that different the classification standard of building as dualisation between the building code and the fire services act. In this study, We have investigated overseas's cases for the PBD of high-rise building and have drawn the improvement direction & the problem of domestic's PBD by comparing and the analysing the domestic regulation.

  • PDF

고층 건물의 실외기실에 위치한 응축기 성능분석 (Analysis of the Condenser Performance Installed in the Air-Conditioning Plant Room of a High-Rise Building)

  • 최석호;이관수;김병순
    • 설비공학논문집
    • /
    • 제15권7호
    • /
    • pp.586-594
    • /
    • 2003
  • The performance of the condenser installed in the air-conditioning plant room of a high-rise building was studied numerically. The effect of the draft direction on the performance of an air-conditioner was analyzed. The on-coil temperature of the condenser was investigated by varying the arrangement and location o( the condenser in the air-conditioning plant room. The performance of an air-conditioner was also evaluated by using COP (coefficient of performance) and CGPI (condenser group performance indicator). The condenser in an air-conditioning plant room should be arranged in such a manner that the fan of the condenser is facing the outside of the building to exhaust the hot air directly, The model by which the condenser is located at the lower-left end of an air-conditioning plant room can prevent the hot air from reentering, and allow indrafting of fresh air. When the direction of draft is to the frontal face of the building, the performance of the condenser above 30th floor is degraded.

System Performance with Variation of Outdoor Unit Layouts at Building Re-entrants

  • Koh, Jae-Yoon;Lee, Hyun-Gu;Zhai, John
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권1호
    • /
    • pp.15-21
    • /
    • 2008
  • Air-cooled split-type air conditioners (AC) are very popular in high-rise residential and commercial buildings in Korea. The performance of such AC systems varies significantly with system characteristics and environmental conditions. Particularly, the outdoor condensing unit of the system, if poorly cooled due to high density of AC distribution and restricted outdoor space, will result in large decrease of cooling efficiency and increase of electrical energy consumption and may further jeopardize the system reliability. This paper presents a numerical analysis on the thermal and energy performance of a group of air-cooled air conditioners installed at a courtyard of a high-rise building. The study introduces a series of new energy performance indices to assess the group performance of the AC condensers with different outdoor unit layouts. The results not only indicate the COP of the systems, but also quantify the system capacity and energy consumption. The evaluation method and indices developed are useful for guiding the design of the distribution plan of the AC units at building re-entrants.

한국의 제로에너지건축 정책 추진에 따른 건축물 에너지기술 성능 연구 (A Study on the Performance Increase in Building Energy Technology according to the Korea's Zero Energy Building Policy)

  • 심홍석;이성주
    • 한국산학기술학회논문지
    • /
    • 제22권5호
    • /
    • pp.543-553
    • /
    • 2021
  • 한국은 건물부문 온실가스 감축 목표 달성을 위한 핵심정책으로 2020년부터 공공부문 신축 건축물을 대상으로 제로에너지건축물 인증 의무화를 시행하였다. 이 논문은 궁극적인 Net Zero 에너지건축물 달성하는 데 있어서 정부의 정책에 따른 건축물 에너지성능의 변화 추세를 파악하고, 최근 건축물에 적용된 에너지기술 성능의 변화 추이를 분석하는 방법론을 제시함으로써 궁극적으로는 장기적인 Net Zero를 달성하고자 하는 정책 환경의 변화에서 건축 관련 이해 관계자들이 건축물 유형별로 적절한 에너지기술들을 적용하는데 도움을 주고자 한다. 본 연구를 위해 최근 4년간 건축물 에너지효율등급 예비인증 데이터를 수집하여 건축물의 에너지성능이 상승하는 추세를 확인하였다. 또한, 최근 건축물에 적용된 에너지기술들의 에너지성능 현황을 분석하기 위하여 K-means 군집분석 활용해 교육연구 시설과 업무시설의 High, Low 에너지성능 군집을 통해 비교군(2016년~2020년, 2020년) 설정하여, 분석하였다. 분석 결과 교육연구 시설의 High, Low 군집 모두 태양광 모듈 면적의 증가율이 261.1%, 283.5% 급증하였으며, 업무시설은 High, Low 군집 모두 태양광 모듈 면적이 감소하는 반면에 대부분의 패시브, 액티브 기술의 에너지성능이 증가하는 것으로 분석되었다.

비재하 내화시험에 의한 섬유혼입 고강도 콘크리트 Mock-up 기둥의 내화성능 평가 (Evaluation of Fire Performance for High Strength Concrete Mock-up Column with Fiber by Unloaded Fire Test)

  • 송영찬;김용로;김욱종;이도범
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.97-100
    • /
    • 2009
  • Fire resistance properties and mechanical properties of high strength concrete mock-up column using organic fiber by KS F 2257 Methods of fire resistance test for elements of building construction and compression test was investigated for application of precast concrete column method of high rise building in this study. As a test result, it was appeared that ECC permanent form is available as fire resistance method of high strength concrete and new precast concrete construction method for facilitating construction of high rise building.

  • PDF

초고층 건축물의 화재안전성능 표준화 구축 (Establishment of Performance Based Design Standardization of Fire Protection Systems for High-Rise Buildings)

  • 손봉세
    • 한국재난정보학회 논문집
    • /
    • 제5권1호
    • /
    • pp.66-74
    • /
    • 2009
  • As building heights increase, so do these challenges in Korea. High-rise buildings present a variety of challenges to fire safety and protection. The fire protection technology in our country is still on a weak situation which is mainly due to the lack of concerns by the government, companies and citizen. This paper provides general guidance regarding fire-related property protection system for high-rise building performance based design. The importance of high-rise building in of the number of occupants, the value of property, and the a catastrophic loss would have on the community all warrant an increased level of protection and life safety. Because, We have to prepare a new spacial code and standard guidance for fire protection at the stage of the high-rise building design.

  • PDF

고인성 복합섬유 모르타르를 이용한 플랫 플레이트 구조 슬래브-기둥 접합부의 전단성능 개선 (Improvement of Shear Performance for High Ductile Fiber-Reinforced Mortar Slab-Column Connection in Flat Plate Structural System)

  • 하기주;김윤용;신종학;양승혁;홍건호;김정수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.145-148
    • /
    • 2005
  • Recently the construction of high-rise reinforced concrete building is progressively increased as the social demands. It is significantly important factors such as economy, the safety of structure, and the flexibility of internal space. Therefore new structural system is also required to be attained the reduction of story height, the flexibility and efficient use of space. The most suitable structural system is with the economy and flexibility, flat plate slab system in high-rise reinforced concrete building. In this research, it was focused in the improvement of shear performance in the flat plate system using high ductile fiber reinforced mortar. It was evaluated the shear performance in the critical region of slab-column connection. The flat plate system, designed by the high performance and safety, was developed as a new technique in the application of high-rise R/C building.

  • PDF