• Title/Summary/Keyword: High Linearity

Search Result 1,069, Processing Time 0.026 seconds

Development and Validation of Analytical Method for Pectolinarin and Pectolinarigenin in Fermented Cirsium setidens Nakai by Bioconversion (생물전환에 의한 발효 고려엉겅퀴 Pectolinarin 및 Pectolinarigenin의 분석법 개발 및 검증)

  • Oh, Ji-Won;Lee, Jin-Ha;Cho, Myoung-Lae;Shin, Gi-Hae;Kim, Jae-Min;Choi, Sun-Il;Jung, Tae-Dong;Kim, Young-Hyun;Lee, Sang-Jong;Lee, Bong Jin;Park, Seon Ju;Lee, Ok-Hwan
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.10
    • /
    • pp.1504-1509
    • /
    • 2015
  • The aim of this study was to investigate a validation method for determination of pectolinarin and pectolinarigenin in fermented Cirsium setidens Nakai. For validation, the specificity, linearity, precision, accuracy, detection limits, and quantification limits of pectolinarin and pectolinarigenin were measured by HPLC. The results show that the detection limits of pectolinarin and pectolinarigenin were $4.25{\mu}g/mL$ and $2.46{\mu}g/mL$, respectively. The recovery rates of pectolinarin and pectolinarigenin were high in the ranges of 99.7~104.0% and 99.7~102.4%, respectively. Inter-day and intra-day precisions of pectolinarin and pectolinarigenin in fermented Cirsium setidens Nakai were 0.9%, 0.5% and 0.5%, 0.2%, respectively. Therefore, application of pectolinarin and pectolinarigenin was validated by an analytical method as a marker compound in Cirsium setidens Nakai.

Development and Performance Test of Preamplifier and Amplifier for Gamma Probe (감마프로브용 전단증폭기와 주증폭기의 개발과 성능 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Lee, Jong-Doo;Kwon, Soo-Il
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.100-109
    • /
    • 1999
  • Purpose: Preamplifier and amplifier are very important parts for developing a portable counting or imaging gamma probe. They can be used for analyzing pulses containing energy and position information for the emitted radiations. The commercial Nuclear Instrument Modules (NIMs) can be used for processing these pulses. However, it may be improper to use NIMs in developing a portable gamma probe, because of its size and high price. The purpose of this study was to develop both preamplifier and amplifier and measure their performance characteristics. Materials and Methods: The preamplifier and amplifier were designed as a charge sensitive device and a capacitor resistor-resistor capacitor (CR-RC) electronic circuit, respectively, and they were mounted on a print circuit board (PCB). We acquired and analyzed energy spectra for Tc-99m and Cs-137 using both PCB and NIMs. Multichannel analyzer (Accuspec/A, Canberra Industries Inc., Meriden Connecticut, U.S.A) and scintillation detectors (EP-047(Bicron Saint-Gobain/Norton Industrial EP-047 (Ceramics Co., Ohio, U.S.A) with $2"{\times}2"$ NaI(T1) crystal and R1535 (Hamamatsu Photonics K.K., Electron Tube Center, Shizuoka-ken, Japan) with $1"{\times}1"$ NaI(T1) crystal were used for acquiring the energy spectra. Results: Using PCB, energy resolutions of EP-047 detectors for Tc-99m and Cs-137 were 12.92% and 5.01%, respectively, whereas R1535 showed 13.75% and 5.19% of energy resolution. Using the NIM devices, energy resolutions of EP-047 detector for Tc-99m and Cs-137 were measured as 14.6% and 7.58%, respectively. However, reliable energy spectrum of R1535 detector could not be acquired, since its photomultiplier tube (PMT) requires a specific type of preamplifier. Conclusion: We developed a special preamplifier and amplifier suitable for a small sized gamma probe that showed good energy resolutions independent of PMT types. The results indicate that the PCB can be used in developing both counting and imaging gamma probe.

  • PDF

Monitoring of Benzoic Acid, Sorbic Acid, and Propionic Acid in Spices (향신료에서 유래되는 안식향산, 소브산, 프로피온산의 함유량 조사)

  • Yun, Sang Soon;Lee, Sang Jin;Lim, Do Yeon;Lim, Ho Soo;Lee, Gunyoung;Kim, MeeKyung
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.5
    • /
    • pp.381-388
    • /
    • 2017
  • In this study, we investigated the levels of natural preservatives of benzoic acid, sorbic acid, and propionic acid in spices. The quantitative analysis was performed using high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) for benzoic acid and sorbic acid and gas chromatography-mass spectrometry (GC-MS) for propionic acid. The sample was extracted with ethanol using sonication, then centrifuged and evaporated to dryness and redissolved to 1 mL with ethanol to use for the instrumental analysis. The analytical method was validated based on linearity, recovery, limit of detection (LOD), and limit of quantification (LOQ). This method was suitable to determine low amounts of naturally occurring preservatives (benzoic acid, sorbic acid, and propionic acid) in various spices. Benzoic acid, sorbic acid, and propionic acid were found in 165 samples, 88 samples, and 398 samples, respectively from the total of 493 samples. The concentration of benzoic acid, sorbic acid, and propionic acid were ranged at ND-391.99 mg/L, ND-57.70 mg/L, and ND-188.21 mg/L in spices, respectively. The highest mean levels of benzoic acid, sorbic acid, and propionic acid were found in cinnamon (167.15 mg/L), basil leaves (22.79 mg/L), and white pepper (51.48 mg/L), respectively. The results in this study provide ranges of concentration regarding naturally occurring benzoic acid, sorbic acid, and propionic acid in spices. Moreover, the results may use to the case of consumer complaint or trade friction due to the inspection services of standard criteria for the preservatives of spices.

Analysis and Safety Assessment of Antioxidants Migrated from Polyethylene and Polypropylene Food Packaging Materials into Food Simulants (폴리에틸렌 및 폴리프로필렌 기구·용기·포장 유래 산화방지제 분석 및 안전성평가)

  • Choi, Heeju;Choi, Jae Chun;Bae, In-Ae;Park, Se-Jong;Kim, MeeKyung
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.5
    • /
    • pp.424-433
    • /
    • 2017
  • Antioxidants are used in the manufacturing of commercial food packages made of polyolefin plastic such as polyethylene and polypropylene for the purpose to delay the oxidation reaction of the polymer due to oxygen or traces of ozone in the atmosphere. Additives in plastics may be migrated from the packaging materials into foods, thereby presenting a potential health risk to the consumer. Therefore, it is necessary to determine migration level of antioxidants from food packaging materials to foodstuffs in order to take proactive management. In this study, we have developed a method for the analysis of 10 antioxidants, which are butylated hydroxyanisole (BHA), butylated hydroxytoluene (BHT), Cyanox 2246, 425 and 1790, Irgafos 168, and Irganox 1010, 1330, 3114 and 1076, migrated from the food packaging materials into four food simulants for aqueous, acidic, alcoholic and fatty foods. The antioxidants were determined by reversed-phase high-performance liquid chromatograph-ultraviolet detector with 276 nm after solid-phase extraction with a hydrophilic-lipophilic balance (HLB) cartridge or dilution with isopropanol. The analytical method showed a good linearity of coefficient ($R^2{\geq}0.99$), limits of detection (0.11~0.41 mg/L), and limits of quantification (0.34~1.24 mg/L). The recoveries of antioxidants spiked to four food simulants ranged from 71.3% to 109.4%. The migrated antioxidants in this study were within the safety levels that resulted from the safety assessment by the estimated daily intake to the tolerable daily intake.

Simultaneous Determination of UV Absorbers Migrated from Polyethylene and Polypropylene Food Packaging Materials into Food Simulants by HPLC-UVD (HPLC-UVD를 이용한 폴리에틸렌, 폴리프로필렌 기구 및 용기·포장 유래 자외선흡수제 동시분석법)

  • Choi, Heeju;Choi, Jae Chun;Bae, In-Ae;Lee, Chanyong;Park, Se-Jong;Kim, MeeKyung
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.5
    • /
    • pp.434-442
    • /
    • 2017
  • The UV light in sunlight breaks down the chemical bonds in a polyolefin polymer through a process called photodegradation, ultimately causing cracking, chalking, colour changes, and loss of physical properties such as impact strength, tensile strength, elongation, and others. UV absorbers are used to prevent or terminate the oxidation of plastics by UV light. They are receptive to UV radiation and dissipate the energy harmlessly as heat. Benzotriazoles and benzophenones are used mainly in polyolefins such as polyethylene and polypropylene. In this study, we have developed a method for the analysis of 12 UV absorbers, which are Uvinul 3000, Cyasorb UV 24, Uvinul 3040, Tinuvin 312 and P, Seesorb 202, Chimassorb 81, Tinuvin 329, 234, 326, 328 and 327, migrated from the food packaging materials into four food simulants for aqueous, acidic, alcoholic and fatty foods. The UV absorbers in food simulants were determined by reversed-phase high performance liquid chromatograph-ultraviolet detector with 310 nm after solid-phase extraction with a hydrophilic-lipophilic balance (HLB) cartridge or dilution with isopropanol. The analytical method showed a good linearity of coefficient ($R^2{\geq}0.99$), limits of detection (0.049~0.370 mg/L), and limits of quantification (0.149~1.120 mg/L). The recoveries of UV absorbers spiked to four food simulants ranged from 70.05% to 110.13%. The developed method would be used as a reliable tool to determine concentrations of the migrated UV absorbers.

The Analysis and Migration of Bisphenol A Related Compounds from Metal Food Cans (식품용 금속 캔으로부터 비스페놀 A 관련 물질들의 분석 및 이행 연구)

  • Park, Se-Jong;Park, So-Ra;Choi, Jae Chun;Kim, MeeKyung
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.4
    • /
    • pp.329-335
    • /
    • 2017
  • Analysis method was presented for the simultaneous determination of nine bisphenol A related compounds such as bisphenol A (BPA), phenol, p-tert-butylphenol, bisphenol A diglycidyl ether (BADGE), $BADGE{\cdot}2H_2O$, $BADGE{\cdot}2HCl$, bisphenol F diglycidyl ether (BFDGE), $BFDGE{\cdot}2H_2O$ and $BFDGE{\cdot}2HCl$ migrated from inner coatings of metal food cans by high performance liquid chromatography (HPLC) with fluorescence detection. The method was validated by examining the linearity of calibration curve, the limit of detection (LOD), the limit of quantification (LOQ), recovery and uncertainty. The migration tests of nine BPA related compounds were carried out with four food simulants; deionized water (DW), 4% acetic acid, 50% ethanol and n-heptane. There was not any compound detected in DW, 4% acetic acid and 50% ethanol at $60^{\circ}C$ for 30 min and n-heptane at $25^{\circ}C$ for 60 min. BPA and phenol were migrated into 4% acetic acid and 50% ethanol at $95^{\circ}C$ for 30 min. The concentrations were ranged from 0 to $10.77{\mu}g/L$ of BPA and from 0 to $2.35{\mu}g/L$ of phenol. Canned foodstuffs mostly have long-term shelf life. We investigated migration of nine BPA related compounds according to the variation in storage periods (0~90 days) and temperatures (4, 25 and $60^{\circ}C$). All compounds were not founded during 90 days at $4^{\circ}C$ and $25^{\circ}C$, respectively. However BPA and $BADGE{\cdot}2H_2O$ were founded in DW and 4% acetic acid at $60^{\circ}C$. The migration levels of BPA and $BADGE{\cdot}2H_2O$ were close to the value of LOQ, respectively and did not change significantly as storage period. It was founded from results that the migration of BPA related compounds from metal food cans was controlled to a safe level.

Establishment of an Analytical Method for Novobiocin in Livestock Products Using HPLC-UVD (HPLC-UVD를 이용한 축산식품 중 Novobiocin의 시험법 확립)

  • Park, Hee-Ra;Kwon, Chan-Hyeok;Lee, Jong-Goo;Kim, Hyung-Soo;Chae, Young-Sik;Oh, Jae-Ho;Kwon, Ki-Sung
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.263-268
    • /
    • 2012
  • Novobiocin is a coumarin-containing antibiotic, and has a longer half-life in various animals than other veterinary medicines. A simple and rapid high-performance liquid chromatography assay for the determination of residual novobiocin levels in chicken, beef and milk has been developed and validated. The separation condition for HPLC/UVD was optimized by a MG II $C_{18}$ (4.6 mm $ID{\times}250$ mm, 5 ${\mu}m$) column with 0.1% formic acid in $H_2O$/0.1% formic acid in Acetonitrile (40/60, v/v) as the mobile phase at a flow rate of 1.0 mL/min and the detection wavelength was set at 340 nm. Residues were extracted from tissue by blending with methanol. After liquid-liquid partitioning, lipid materials were removed with n-hexane and purification as Silica (1 g, 6 mL) cartridge with 10 mL acetone/dichloromethane (10/90, v/v). Limit of quantification and linearity performed by the analytical method were 0.02 mg/kg and 0.999 ($r^2$), and the recovery range was $88.8{\pm}5.6-100.3{\pm}4.4$, $88.8{\pm}7.2-97.0{\pm}3.2$ and $88.1{\pm}4.3-92.8{\pm}3.6%$. It is expected that this analytical method with regards to novobiocin in chicken, beef and milk could be applied as an official method to administer food safety on veterinary medicines.

Determination of Carazolol and Azaperone in Livestock and Fishery Products Using Liquid Chromatography-tandem Mass Spectrometry (축수산물에서 LC-MS/MS를 이용한 카라졸롤 및 아자페론 분석)

  • Choi, Soo Yeon;Kang, Hui-Seung;Kim, Joohye;Cheon, So-Young;Jeong, Jiyoon;Cho, Byung-Hoon;Lee, Kang-Bong
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.3
    • /
    • pp.176-184
    • /
    • 2018
  • The aim of the present work was to develop simultaneous methods of quantification of carazolol, azaperone, and azaperol residues in livestock and fishery products using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Samples were extracted from beef, pork, chicken, egg, milk and shrimp using acetonitrile (ACN); while flat fish and eel were extracted using 80% ACN. For purification, ACN saturated n-hexane was used to remove fat composition. The standard calibration curves showed good linearity as correlation coefficients; $r^2$ was > 0.99. Average recoveries expressed were within the range of 67.9-105% for samples fortified at three different levels ($0.5{\times}MRL$, $1{\times}MRL$ and $2{\times}MRL$). The correlation coefficient expressed as precision was within the range of 0.55-7.93%. The limit of quantification (LOQ) was 0.0002-0.002 mg/kg. The proposed analytical method showed high accuracy and acceptable sensitivity based on Codex guideline requirements (CAC/GL71-2009). This method can be used to analyze the residue of carazolol, azaperone, and azaperol in livestock and fishery products.

Genetic Analysis of Natural Microflora in the Stored Joraengyi Rice Cake and Their Capability of Propionic Acid Production (조랭이 떡에 존재하는 자연균총 유전자 군집분석 및 천연유래 프로피온산 생성능 분석)

  • Park, Hee-Dae;Chae, Jung-Kyu;Ha, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.5
    • /
    • pp.375-382
    • /
    • 2018
  • This study was conducted to analyze the microbial community and propionic acid production ability of natural microflora in the rice cakes. Genetic analysis of natural microflora in Jorangyi rice cake was performed to select propionic acid - producing bacteria. Selected propionic acid-producing bacteria were cultivated in TSB (tryptic soy broth) supplemented with glucose, and growth characteristics were analyzed by temperature and production of propionic acid was analyzed by gas chromatography (GC-FID). Linearity, detection limit, quantitative limit, and recovery rate were measured to verify propionic acid assay. A total of 98 microbial strains were detected from microflora of Joraengyi rice cake that grew after expiration of shelf life. Lactobacillus casei group accounted for 50.48% and Lactobacillus buchneri was 29.60%. Propionic acid - producing bacteria were Propionibacterium thoenii, P. cyclohexanicum, Propionibacterium_uc, P. jensenii, and P. freudenreichii. Natural bacteria and Lactobacillus spp. did not produce propionic acid during 14 days but P. cyclohexanicum, P. freudenreichii subsp. Shermanii, P. thoenii and P. jesenii produced $263.47{\mu}g/mL$, $338.90{\mu}g/mL$, $325.43{\mu}g/mL$ and $222.17{\mu}g/mL$ during 4 days and 2,462.02 and 2,904.78, 2,220.64, $3,519.17{\mu}g/mL$ during 14 days. As a result of this study, it was affirmed that the natural microflora of Joraengyi rice cake during storage can produce propionic acid from natural sources even if a high concentration of propionic acid is not intentionally added. Because of characteristics of rice cake composed of starch and glucose. This study will be used as a recognition criterion to detect natural preservatives such as propionic acid in starchy foods such as rice cakes and as reference standard safety management data.

Isolation, Quality Evaluation, and Seasonal Changes of Bakkenolide B in Petasites japonicus by HPLC (머위로부터 Bakkenolide B의 순수분리, HPLC분석 방법 및 채취 시기별 함량 분석)

  • Kim, Tae Hoon;Kim, Do Youn;Jung, Won Jung;Nagaiya, Ravichandran;Son, Beung Gu;Park, Young Hoon;Kang, Jum Soon;Lee, Young Jae;Im, Dong-Soon;Lee, Young-Geun;Choi, Yung Hyun;Choi, Young-Whan
    • Journal of Life Science
    • /
    • v.24 no.3
    • /
    • pp.252-259
    • /
    • 2014
  • The leaves of Peatasites japonicus are a traditional oriental medicine with diverse biological activities. A simple and specific analytical method for the quantitative determination of bakkenolide B constituents from methanolic extract of the leaves of P. japonicus was developed. Bakkenolide B was isolated from the leaves of P. japonicus, and its structure was elucidated based on 1D, 2D NMR, and GC-MS spectral data. A liquid chromatographic method was developed to evaluate the quality of P. japonicus through determination of major active compound, bakkenolide B. The wavelengths at 254 and 215 nm were chosen to determine bakkenolide B. The recovery of the method was in the range of 98.6 to 103.1%, and bakkenolide B showed good linearity ($r^2$=0.999) within test ranges. The developed method was applied to the determination of bakkenolide B in the plant part and seasonal changes. The results showed that the content of bakkenolide B in the leaf was higher than in the petiole and rhizome. In this study, a simple, rapid, and reliable high-performance liquid chromatography method was used to determine the percentage and composition of bakkenolide B in P. japonicus procured from different Petasites species plants in South Korea. The method can be employed in routine quantitative analysis and quality control of different products in the market.