• 제목/요약/키워드: High LET

검색결과 288건 처리시간 0.028초

고주파 회전자계를 이용한 역전자계 배위 안정성연구 (A Study on the Formation of Reversed Field configuration stability with Radio Rotating Field)

  • 김원섭;황종선;김종만;김영민
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 영호남 합동 학술대회 및 춘계학술대회 논문집 센서 박막 기술교육
    • /
    • pp.121-124
    • /
    • 2006
  • It is widely know that one of the most important tasks is the research of plasma for the purpose o nuclear fusion, is to make a stable confinement of high ${\beta}$ value plasma. And, for making the stable confinement, pinch pl-asma produced by reversed field has been mainly studied yet. Magnetic field has been used to hold plasma at high temperature for a long time. Reverse field has shown unstable process. Using ratio frequency, the author could control the instability of the process and formed a stable erversed field. Inthe experiment let a reversed field configuration from by adding-Bias field in advance.

  • PDF

직기에 있어서 Computer의 응용 (A study on the application of computer used in a loom)

  • 조백희;김광영;김종수;이태세
    • 한국기계연구소 소보
    • /
    • 통권19호
    • /
    • pp.171-180
    • /
    • 1989
  • The automation of textile machinery in the fabric manufacture is strongly demanded in order to improve the industrial structure related to labour-force and cost curtailment, in addition, to keep step with the various and small production system and the consumption tendency requesting a high quality fabrics. In this thesis, the technology applying the computer to an air jet loom and characteristics obtained from it are derived. To efficently apply an automized and unmanned textile machinery, an air jet loom is equipped with the let-off, take-up and weft insertion device attached a central processing unit(CPU) which can automatically operate according to a program. As a result, an air jet loom is available for the factory automation, which has advantages including productivity promotion, high quality security, energy savings, specification & variety, efficient production control, in fabric manufacturing process.

  • PDF

A SOLUTION TO THE PROBLEM WITH ABSORBED DOSE

  • Braby, Leslie A.
    • Nuclear Engineering and Technology
    • /
    • 제40권7호
    • /
    • pp.533-538
    • /
    • 2008
  • In some situations, for example at very low doses, in microbeam irradiation experiments, or around high energy heavy ion tracks, use of the absorbed dose to describe the energy transferred to the irradiated target can be misleading. Since absorbed dose is the expected value of energy per mass it takes into account all of the targets which do not have any energy deposition. In many situations that results in numerical values, in Joules per kg, which are much less than the energy deposited in targets that have been crossed by a charged particle track. This can lead to confusion about the biochemical processes that lead to the consequences of irradiation. There are a few alternative approaches to describing radiation that avoid this potential confusion. Examples of specific situations that can lead to confusion are given. It is concluded that using the particle radiance spectrum and the exposure time, instead of absorbed dose, to describe these irradiations minimizes the potential for confusion about the actual nature of the energy deposition.

고주파 회전자계를 이용한 역전자계 배위 안정성연구 (A Study on the Formation of Reversed Field configuration stability with Radio Rotating Field)

  • 김원섭;황종선;김종만;김영민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2187-2189
    • /
    • 2005
  • It is widely know that one of the most important tasks is the research of plasma for the purpose o nuclear fusion, is to make a stable confinement of high ${\beta}$ value plasma. And, for making the stable confinement, pinch p1-asma produced by reversed field has been mainly studied yet. Magnetic field has been used to hold plasma at high temperature for a long time. Reverse field has shown unstable process. Using ratio frequency, the author could control the instability of the process and formed a stable erversed field. Inthe experiment let a reversed field configuration from by adding-Bias field in advance.

  • PDF

Radiation Biology in Space; DNA Damage and Biological Effects of Space Radiation

  • Ohnishi, Takeo;Takahashi, Akihisa;Ohnishi, Ken
    • Journal of Photoscience
    • /
    • 제9권3호
    • /
    • pp.37-40
    • /
    • 2002
  • Astronauts are constantly exposed to space radiation at a low-dose rate during long-tenn stays in space. Therefore, it is important to determine correctly the biological effects of space radiation on human health. Space radiations contain various kinds of different energy particles, especially high linear energy transfer (LET) particles. Therefore, we have to study the relative biological effectiveness (RBE) of space radiation under microgravity environment which may change RBE from a stress for cells. Furthermore, the research about space radiation might give us useful information about birth and evolution of life on the earth. We also can realize the importance of preventing the ozone layer from depletion by use of exposure equipment to sunlight at International Space Station (ISS).

  • PDF

A Study for Establishment of High Dose Radioiodine Therapy Patients' Release Standard

  • Park, Hoon-Hee;Kim, Hyun-Soo;Dong, Kyung-Rae
    • 대한디지털의료영상학회논문지
    • /
    • 제13권4호
    • /
    • pp.153-156
    • /
    • 2011
  • This study, which is proceeded in the department of nuclear medicine, aims at preventing unnecessary radiation exposure to the patients and the people near the patients by understanding and presenting the realities about the isolating period for the high dose radioiodine patients after total thyroidectomy in the 7 general hospitals in metropolitan area. Theoretically, the physical half-life of the high dose radioiodine is 8 days. Radioiodine lower than 100 mCi usually is eliminated all in 2 days 1 night considering the biological half-life and the amount of excreting radioiodine The hospitalization standard of the patients treated with high-dose radioiodine therapy has been established according to the fact above. Investigation of the data and questionnaire from the hospital have proven that some hospitals didn't even measure the acceptable dose because of the faith in the vague data. Besides, the some of those inevitably let the readmitting patients exceeding the acceptable dose be in the general ward, not in the isolation ward, because the number of the isolation rooms is relatively smaller than the patients. Thus, we want to contribute that patients understand the realities and the hospitals consider the relevant problem actively so that the problem will be settled by this journal.

  • PDF

Development of High Energy Particle Detector for the Study of Space Radiation Storm

  • Jo, Gyeong-Bok;Sohn, Jongdae;Choi, Cheong Rim;Yi, Yu;Min, Kyoung-Wook;Kang, Suk-Bin;Na, Go Woon;Shin, Goo-Hwan
    • Journal of Astronomy and Space Sciences
    • /
    • 제31권3호
    • /
    • pp.277-283
    • /
    • 2014
  • Next Generation Small Satellite-1 (NEXTSat-1) is scheduled to launch in 2017 and Instruments for the Study of Space Storm (ISSS) is planned to be onboard the NEXTSat-1. High Energy Particle Detector (HEPD) is one of the equipment comprising ISSS and the main objective of HEPD is to measure the high energy particles streaming into the Earth radiation belt during the event of a space storm, especially, electrons and protons, to obtain the flux information of those particles. For the design of HEPD, the Geometrical Factor was calculated to be 0.05 to be consistent with the targets of measurement and the structure of telescope with field of view of $33.4^{\circ}$ was designed using this factor. In order to decide the thickness of the detector sensor and the classification of the detection channels, a simulation was performed using GEANT4. Based on the simulation results, two silicon detectors with 1 mm thickness were selected and the aluminum foil of 0.05 mm is placed right in front of the silicon detectors to shield low energy particles. The detection channels are divided into an electron channel and two proton channels based on the measured LET of the particle. If the measured LET is less than 0.8 MeV, the particle belongs to the electron channel, otherwise it belongs to proton channels. HEPD is installed in the direction of $0^{\circ}$, $45^{\circ}$, $90^{\circ}$ against the along-track of a satellite to enable the efficient measurement of high energy particles. HEPD detects electrons with the energy of 0.1 MeV to several MeV and protons with the energy of more than a few MeV. Thus, the study on the dynamic mechanism of these particles in the Earth radiation belt will be performed.

FUNCTIONAL EQUATIONS ASSOCIATED WITH INNER PRODUCT SPACES

  • Park, Choonkil;Huh, Jae Sung;Min, Won June;Nam, Dong Hoon;Roh, Seung Hyeon
    • 충청수학회지
    • /
    • 제21권4호
    • /
    • pp.455-466
    • /
    • 2008
  • In, [7], Th.M. Rassias proved that the norm defined over a real vector space V is induced by an inner product if and only if for a fixed integer $n{\geq}2$ $$n{\left\|{\frac{1}{n}}{\sum\limits_{i=1}^{n}}x_i{\left\|^2+{\sum\limits_{i=1}^{n}}\right\|}{x_i-{\frac{1}{n}}{\sum\limits_{j=1}^{n}x_j}}\right\|^2}={\sum\limits_{i=1}^{n}}{\parallel}x_i{\parallel}^2$$ holds for all $x_1,{\cdots},x_{n}{\in}V$. Let V,W be real vector spaces. It is shown that if a mapping $f:V{\rightarrow}W$ satisfies $$(0.1){\hspace{10}}nf{\left({\frac{1}{n}}{\sum\limits_{i=1}^{n}}x_i \right)}+{\sum\limits_{i=1}^{n}}f{\left({x_i-{\frac{1}{n}}{\sum\limits_{j=1}^{n}}x_i}\right)}\\{\hspace{140}}={\sum\limits_{i=1}^{n}}f(x_i)$$ for all $x_1$, ${\dots}$, $x_{n}{\in}V$ $$(0.2){\hspace{10}}2f\(\frac{x+y}{2}\)+f\(\frac{x-y}{2} \)+f\(\frac{y}{2}-x\)\\{\hspace{185}}=f(x)+f(y)$$ for all $x,y{\in}V$. Furthermore, we prove the generalized Hyers-Ulam stability of the functional equation (0.2) in real Banach spaces.

  • PDF

마우스모델을 이용한 고속중성자선의 성장지연 및 산소증강비의 측정 (Measurement of Growth Delay and the Oxygen Enhancement Ratio of Fast Neutron Beam Using Mouse Model System)

  • 엄근용;박혜진;권은경;예성준;이동한;우홍균
    • Journal of Radiation Protection and Research
    • /
    • 제32권4호
    • /
    • pp.178-183
    • /
    • 2007
  • 중성자선은 고 LET (linear energy transfer) 방사선으로 X선이나 감마선 등의 저 LET 방사선보다 세포에 더욱 큰 손상을 입힌다. 중성자에 의한 손상은 일반적으로 세포에 있어서 치명적이며, 중성자선은 X선이나 감마선에 비하여 직접작용을 통하여 세포사를 일으키는 경향이 있다. 본 연구에서는 고속중성자선의 성장지연비 및 산소증강비를 동물실험을 통하여 측정하고자 하였다. BALB-c 마우스의 우측 하지에 EMT-6 세포주를 이식한 후 종양의 평균용적이 $200-300mm^3$가 되었을 때 X선 및 고속중성자선을 조사하였다. 정상산소환경 및 저산소환경의 종양에 대하여 X선은 0, 11, 15.4 Gy를 조사하였고 고속중성자선은 0, 5, 7, Gy를 조사하였다. 방사선조사 후에는 종양의 용적을 주 3회 측정하였다. 정상산소환경 실험군의 경우 저산소환경 실험군에 비하여 X선 11 Gy를 조사하였을 때 성장지연비가 1.34였고, 15.4 Gy를 조사하였을 때 1.33였다. 고속중성자선을 조사한 경우정상산소환경 실험군이 저산소환경 실험군에 비하여 고속중성자선 5 Gy를 조사하였을 때 성장지연비는 0.94였고, 고속중성자선 7 Gy를 조사하였을 때 0.98였다. 고속중성자선의 산소증강비는 0.97이었다. 고속중성자선은 X선에 비하여 저산소환경에 있는 종양의 성장억제에 있어서 보다 효과적이었다.

DC/DC 강압컨버터의 PWM-IC 제어기의 TID 및 SEL 실험 (TID and SEL Testing on PWM-IC Controller of DC/DC Power Buck Converter)

  • 노영환;황의성;정재성;한창운
    • 한국항공우주학회지
    • /
    • 제41권1호
    • /
    • pp.79-84
    • /
    • 2013
  • DC/DC 컨버터는 임의의 직류전원을 부하가 요구하는 형태의 직류전원으로 변환시키는 효율이 높은 전력변환기이다. DC/DC 컨버터는 PWM-IC(펄스폭 변조 집적회로) 제어기, MOSFET(산화물-반도체 전계 효과 트랜지스터), 인덕터, 콘덴서 등으로 구성되어있다. 코발트 60 ($^{60}Co$) 저준위 감마발생기를 이용한 TID실험에서 방사선의 영향으로 PWM-IC의 전기적 특성중에 문턱전압과 옵셋전압이 증가되고, SEL에 적용된 4종류의 중이온 입자는 PWM-IC의 파형을 불안정하게 만든다. 또한, 입/출력관계의 파형을 SPICE 시뮬레이션 프로그램으로 관찰하였다. PWM-IC의 TID 실험은 30 Krad 까지 수행하였으며, SEL 실험을 제어보드를 구현한 후 LET($MeV/mg/cm^2$)별 cross section($cm^2$)으로 연구하였다.