• Title/Summary/Keyword: High Frequency noise

Search Result 2,060, Processing Time 0.029 seconds

Analysis of Interior Noise for KTX in Tunnel with Concrete Track (콘크리트 궤도 터널 내 KTX 차량의 실내소음 특성 분석)

  • Kim, Jae-Chul;Lee, Chan-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.25-28
    • /
    • 2005
  • The interior noise of KTX in tunnel is becoming the problem since the commercial operating in April 2004. The major sources of interior noise for High speed train ate known as the aerodynamic noise and rolling noise generally. We measure the noise and vibration inside KTX in tunnel in order to find the cause of the interior noise of KTX. The analysis results show that the interior noise of KTX in tunnel with concrete track is increased sharply by a low frequency below 80Hz that is the natural frequency of the KTX carbody. We know that the booming noise inside KTX in tunnel with concrete track is generated by aerodynamic noise outside ganqway and rolling noise at the carbody natural frequency.

  • PDF

Exhaust Noise Control of Marine Diesel Engine Using Hybrid Silencer (조합형 소음기를 이용한 박용 디젤 엔진 배기 소음 제어)

  • Lee, Tae-Kyoung;Joo, Won-Ho;Bae, Jong-Gug
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.7
    • /
    • pp.679-684
    • /
    • 2009
  • Low frequency exhaust noise of marine diesel engine is one of the most important noise sources in vessels. However, conventional absorptive silencers are ineffective to control exhaust noise because of low absorption in the low frequency range. In the paper, exhaust noise control of marine diesel engine was studied by using the hybrid silencer, which was composed of virtually divided array of concentric hole-cavity resonators and conventional absorptive silencer. A series of tests including field tests were performed to investigate the acoustic performance of the hybrid silencer. Consequently, its high performance of 5${\sim}$10 dB noise reduction in the low frequency range was confirmed and it is expected to be very helpful in reducing the exhaust noise of marine diesel engine.

Investigation of noise source localization on High speed train (고속철도 소음원의 위치규명에 관한 고찰)

  • Koh, Hyo-In;You, Won-Hee;Lee, Jun-Seok
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1590-1597
    • /
    • 2007
  • This paper deals with the noise source localization of the Korean High Speed Train (KTX) at the speed of 300 km/h. Using Microfonarray system and beamforming technology typical pass-by noise sources and their frequency characteristics are investigated. It is primarily aimed at investigating the location and characteristics of the high speed train emission. The results from the microphone array tests are also analyzed in relation to the remarks from analytic studies and experimental investigations on the high speed train that have been done with the intention of understanding the interior noise mechanism. The acoustical image shows the low frequency noise sources mainly at the position of the under part of the train at high speeds and the related source mechanism are discussed.

  • PDF

Noise reduction method using a variance map of the phase differences in digital holographic microscopy

  • Hyun-Woo Kim;Myungjin Cho;Min-Chul Lee
    • ETRI Journal
    • /
    • v.45 no.1
    • /
    • pp.131-137
    • /
    • 2023
  • The phase reconstruction process in digital holographic microscopy involves a trade-off between the phase error and the high-spatial-frequency components. In this reconstruction process, if the narrow region of the sideband is windowed in the Fourier domain, the phase error from the DC component will be reduced, but the high-spatial-frequency components will be lost. However, if the wide region is windowed, the 3D profile will include the high-spatial-frequency components, but the phase error will increase. To solve this trade-off, we propose the high-variance pixel averaging method, which uses the variance map of the reconstructed depth profiles of the windowed sidebands of different sizes in the Fourier domain to classify the phase error and the high-spatial-frequency components. Our proposed method calculates the average of the high-variance pixels because they include the noise from the DC component. In addition, for the nonaveraged pixels, the reconstructed phase data created by the spatial frequency components of the widest window are used to include the high-spatialfrequency components. We explain the mathematical algorithm of our proposed method and compare it with conventional methods to verify its advantages.

Towards reducing acoustical high-frequency noise of a direct current relay via contact structure (직류 계전기의 접촉구조에 의한 고주파수 소음저감)

  • Junhyeok, Yang;Jongseob, Won;Wonjin, Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.6
    • /
    • pp.691-697
    • /
    • 2022
  • In this work, a straightforward component design of a direct current (DC) relay equipped in electric vehicles is discussed. The work aims to provide and evaluate effective measures for reducing high-frequency sound from the DC relay carrying electric power. From the operation experiments for the relay, it is observed that noise is caused by the resonance from the forced vibration by the electromagnetic repulsive force originating at the area of electric contacts with a resonance frequency of around 710 Hz ~ 730 Hz. A finite element model for the relay was established to conduct vibration mode analysis, consisting of stationary and movable contacts and a contact spring. Vibration mode analysis indicates that in the resonance frequency, the movable contact with two-point contacts experiences rotational vibration mode. For the proposed relay with a three-point contact, vibration mode analyses give reasonable results of reducing noise at that frequency. Furthermore, for the fabricated relays with the three-point contact, similar results have been obtained. In conclusion, one can see that the proposed measures provide one of the feasible solutions to the reduction of relay noise.

Development of Noise Analysis Software-'NASPFA' in Medium-to-high Frequency Ranges using Power Flow Boundary Element Method (파워흐름경계요소법을 이용한 중고주파 소음해석 소프트웨어 'NASPFA' 개발)

  • Lee, Ho-Won;Hong, Suk-Yoon;Kwon, Hyun-Wung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.949-953
    • /
    • 2004
  • In this paper, Power Flow Boundary Element Method(PFBEM) is studied as the numerical method for the vibration and sound predictions of complex structures in medium-to-high frequency ranges. NASPFA, the sound analysis software based on PFBEM, is developed and is used for the vibro-acoustic analysis. And also the developed software is used for the prediction of interior and exterior sound fields of vibrating structures and for the analysis of the multi-domain problems. To verify the accuracy, NASPFA is applied to the prediction of the energy distribution in the simple structures, and its results are compared with exact PFA solutions. And various practical vehicle systems are modeled and the distributions of the acoustical energy density are successfully predicted.

  • PDF

Speckle Noise Reduction for 3D Power Doppler Ventricle Image Restoration Using Wavelet Packet Transform

  • Jung, Eun-sug;Ryu, Conan K.R.;Hur, Chang Wu;Sun, Mingui
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.156-159
    • /
    • 2009
  • Speckle noise reduction for 3D power doppler ventricle coherent image for restoration and enhancement using wavelet packet transform with separated thresholding is presented. Wavelet Packet Transform divide into low frequency component image to high frequency component image to be multi-resolved. speckle noise is located on high frequency component in multiresolution image mainly. A ventricle image is transformed and inversed with separated threshold function from low to high resolved images for restoration to be utilize visualization for ventricle diagnosis. The experimental result shows that the proposed method has better performance in comparison with the conventional method.

  • PDF

Frequency Response Function Based Substructural Analysis of Interior Noise (전달함수를 이용한 차실 소음의 부분구조 해석)

  • 황우석;이두호
    • Journal of KSNVE
    • /
    • v.10 no.3
    • /
    • pp.480-485
    • /
    • 2000
  • This paper presents the application of the substrctural analysis based on the frequency responses for the prediction of the interior noise in a car. The complex trimmed body with the high modal density is presented by the experimental data. Finite element model presents the powertrain and its subframes with the lower modal density. The substructural analysis based on the frequency responses combines the frequency response functions from the numerical analysis and the experiments. It describes the interior noise successwfully. Using this method we can pick up the most dominant paths for the booming noise and predict the effects of the design changes easily.

  • PDF

A analysis of frequency characteristics for the noise cut transformer (노이즈 차폐 변압기의 주파수 특성 분석)

  • Kim, Myoung-Seok;Oh, Joon-Sik;Cho, Hyun-Kil;Han, Gyu-Hwan;Park, Jong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.957-959
    • /
    • 2005
  • A noise reduction equipment in power systems was device combined in a passive element such as the form of L, R and C. A analysis of frequency characteristics for the transformer models shall be considered the additional capacitance between the windings($C_{ps}$), terminals($C_s$), and winding-ground($C_g$). A noise in transformer is modeled by take account into the different frequency. In case of the high frequency, transformer windings with stray capacitance have lower impedance. Therefore a noise is transferred from primary winding to secondary winding. Noise Cut Transformer(NCT) was the noise reduction device and was normally single phase two-winding type transformer. We analyzed frequency characteristics using the nodal network analysis with the equivalent circuit and the simulation of the MATLAB.

  • PDF

The Study on the Characteristic Sound Intensity and Frequency of Noise Exposure at Occupational Sites (산업장 소음의 강도 및 주파수 특성에 관한 조사연구)

  • Kim, Kwang Jong;Cha, Chul Whan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.181-191
    • /
    • 1991
  • The present study determined the overall noise level and the distribution of sound pressure level over audible frequency range of noise produced at various work sites. Work-related noise greater than 80dBA produced from 98 separate work sites at 37 manufacturing companies and machine shops were analysed for the overall sound level (dBA) and frequency distribution. In addition, to determine the possible hearing loss related to work site noise, a hearing test was also conducted on 1,374 workers in these work sites. The results of the study were as follows ; 1. Of the total 98 work sites, 57 work sites(58.2%) produced noise exceeding threshold limit value (${\geq}90dBA$) set by the Ministry 01 Labor. In terms of different manufacturing industries the proportion of work sites which exceeded 90dBA was the highest for the cut-stone products industry with 6/6 work sites and lowest for the commercial printing industry with 1/13 work sites. 2. The percentage of workers who were exposed to noise greater than 90dBA was 19.8% (1,040 workers) 01 the total 5,261 workers. In terms of different industries, cut-stone products industry had the most workers exposed to noise exceeding 90dBA with 82.8%, textile bleaching and dyeing industry was next at 30.6% followed by fabricated metal products industry with 27.9%, plastic products manufacturing industry had the lowest percentage of workers exposed to 90dBA exceeding noise with 4.5%. 3. There was a statistically significant correlation between the frequency of noise-induced hearing loss and the percentage of workers exposed to noise exceeding 90dBA (P<0.05). 4. The frequency analysis of noise produced at the 98 work sites revealed that 44 work sites (44.9%) had the maximum sound pressure level at high-frequencies greater than 2KHz. In addition, significantly higher sound pressure level was detected at the high-frequencies at 90dBA exceeding work sites as compared to below 90dBA work sites (P<0.01). 5. The differences in sound level meter's A-and C-weighted sound pressure levels were analysed by frequencies. Of the 28 work sites which showed 0-1 dB difference in the two weighted sound levels, 20 work sites (71.4%) had significantly higher sound pressure levels at high-frequencies greater than 2KHz (P<0.01). Furthermore, there was a tendency for higher sound pressure levels to occur in the high-frequency range as the differences in the two weighted sound levels decreased.

  • PDF