• 제목/요약/키워드: High Frequency Attenuation

검색결과 237건 처리시간 0.026초

핵의학 영상의 물리적 인공산물보정: 정규화보정 및 감쇠보정 (Physical Artifact Correction in Nuclear Medicine Imaging: Normalization and Attenuation Correction)

  • 김진수;이재성;천기정
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권2호
    • /
    • pp.112-117
    • /
    • 2008
  • Artifact corrections including normalization and attenuation correction were important for quantitative analysis in Nuclear Medicine Imaging. Normalization is the process of ensuring that all lines of response joining detectors in coincidence have the same effective sensitivity. Failure to account for variations in LOR sensitivity leads to bias and high-frequency artifacts in the reconstructed images. Attenuation correction is the process of the correction of attenuation phenomenon lies in the natural property that photons emitted by the radiopharmaceutical will interact with tissue and other materials as they pass through the body. In this paper, we will review the several approaches for normalization and attenuation correction strategies.

피부에 의한 이득 감쇠를 줄이기 위한 FEA 시뮬레이션 기반의 이식형 마이크로폰 설계 및 구현 (Design and Fabrication of an Implantable Microphone for Reduction of Skin Damping Effect through FEA Simulation)

  • 한지훈;김민우;김동욱;성기웅;조성목;박일용;조진호
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권1호
    • /
    • pp.59-65
    • /
    • 2008
  • Nowadays, implantable hearing aids have been developed to solve the problems of conventional hearing aids. In case of fully implantable hearing aids, an implantable microphone is necessary to receive sound signal beneath the skin. Normally, an implantable microphone has poor frequency response characteristics in high frequency bands of acoustic signal due to the high frequency attenuation effect of skin after implantation to human body. In this paper, the implantable microphone is designed to reduce the high frequency attenuation effect of a skin by putting its resonance frequency at the attenuated range through a finite element analysis (FEA) simulation. The designed implantable microphone through the simulated results has been fabricated by manufacturing process using bio-compatible materials. By the several in-vitro experiments with pig skin, it has been verified that the designed implantable microphone has a resonance frequency around the starting part of the attenuated range and reduces the attenuation effect.

지중배전케이블에서 반도전층을 고려한 주파수 응답 및 전파특성 분석 (Analysis of Frequency Response Characteristic Considering Semiconducting Screen in Underground Distribution Cables)

  • 정채균;이종범;김정태
    • 전기학회논문지
    • /
    • 제61권8호
    • /
    • pp.1091-1098
    • /
    • 2012
  • This paper describes frequency response and propagation characteristics considering semiconducting screen in distribution cables. In CIGRE WG 21-05, Simplified Approach(SA) and Rigorous Approach(RA) which can revise the permittivity considering semiconducting screen propose for more detailed EMTP model and frequency dependant analysis. In this paper, the frequency dependent characteristics of complex permittivity are variously analysed by cole-cole function of RA. The attenuation, propagation velocity and surge impedance according to frequency range(1 kHz to 500 MHz) and cable length are also analysed by SA and EMTP simulation in distribution cables. The propagation velocity considering semiconducting screen is slower, and it is saturated over the range of 1 MHz. The signal is significantly attenuated as frequency range is high.

초음파의 파형 해석에 의한 고감쇠 재료의 평가 (Evaluation of High Attenuation Material Using Utrasonic Wave Analysis)

  • 남영현
    • 비파괴검사학회지
    • /
    • 제15권2호
    • /
    • pp.364-370
    • /
    • 1995
  • 본 논문은 초음파법을 이용하여 소결 재료의 비파괴적인 평가 방법을 확립하는데 목적을 두고 있다. 소결 재료의 밀도는 소결체로 제작되는 동안 금형과 분말사이의 마찰 때문에 부분적으로 불균질한 분포를 가지고 있으며 이 불균질성은 에너지 감쇠 계수 및 초음파 반사 에코의 주파수 스펙트럼에 있어 중심 주파수의 변화량에 의해 조사되었다. 초음파의 속도, 탄성계수, 포와송 비는 소결 재료의 밀도와 비례 관계에 있었으며 저면 반사파의 중심 주파수는 초음파의 전파 거리의 증가 및 밀도의 감소에 따라 저주파수 쪽으로 이동하였으나 에너지 감쇠 계수는 밀도의 증가에 따라 감소하고 있었다. 본 논문에서는 반사파의 주파수 스펙트럼에 있어 중심 주파수의 변화가 소결 재료의 비파괴적인 평가 방법으로써의 가능성을 보여주고 있다.

  • PDF

초음파를 이용한 기체 유동장내 분진 모니터링 (Particle Monitoring Using Ultrasound in the Gas Flow)

  • 장경영;김주철;김홍준;황원호
    • 한국정밀공학회지
    • /
    • 제21권10호
    • /
    • pp.78-85
    • /
    • 2004
  • The particle amount monitoring technique using ultrasound is proposed to determine the proper maintenance time of the filter in the supply process of pure gas in the unit of oxygen plant. There are advantages that it is adaptable in high temperature and high pressure, and it is not disturbed by being exposed in the gas flow, and it can be implemented very economically. The applicability of the ultrasonic technique is pre-studied through the theoretical analysis for the dependency of attenuation of ultrasonic wave on the particles in the gas flow. For the purpose, absorption, scattering and dispersion models are considered, and the attenuation by absorption and the change rate of the propagation speed are calculated fur the specific range of particle size and the ultrasonic wave frequency. It was expected by simulation that the absorptive attenuation by particles was the most sensitive to the change of particle amount. The experimental result showed high correspondence with the theoretical expectation so that this ultrasound attenuation measurement was proved to be highly effective for monitoring the amount of floating particles in the gas flow.

초음파 C-Scan을 이용한 구조용 세라믹스의 기계적 특성평가 (Evaluation of Mechanical Properties of Structural Ceramics ($Al_{2}O_{3}$) Using the High Frequency Ultrasonic C - Scan)

  • 장영권
    • 비파괴검사학회지
    • /
    • 제9권2호
    • /
    • pp.18-24
    • /
    • 1989
  • Computer-aided high frequency ultrasonic is applied to aluminum oxide(85w%, 94w%, 96w%, and 99w%) MOR(modulus of rupture) samples to evaluate mechanical properties such as density variation, pore content, elastic modulus, shear modulus, and poisson's ratio. Ultrasonic wave velocity and attenuation measurement techniques were used as an evaluator of such properties. Pulse-echo C-Scan images with different fate setting method using 50MHz center frequency 1 inch focal length transducer allows evaluation of density variation and pore content. Elastic modulus calculated with the relation of density and ultrasonic velocity. It shows good reliability as compared with resonance method. Sintered density variation of $0.025g/cm^{3}$, that is 0.6% of theoretical density in $Al_{2}O_{3}$ samples can be observed by ultrasonic velocity measurement. Attenuation measurement method qualitatively agree with 4-point fracture testing result concerning of porosity content.

  • PDF

LED-TV용(用) 전원장치에 적합한 Hybrid 초크 코일의 특성 해석에 관한 연구 (A Study on the Characteristic Analysis of Hybrid Choke Coil suitable for LED-TV SMPS)

  • 김종해;김희승;원재선
    • 조명전기설비학회논문지
    • /
    • 제28권3호
    • /
    • pp.32-43
    • /
    • 2014
  • This paper presents the intra capacitance modeling according to the winding method, section bobbin and coil structure for hybrid choke coil capable of the EMI attenuation of broad bands from lower frequency bands to higher frequency bands and high frequency type common-mode choke coil capable of the EMI attenuation of high frequency band used in the EMI Block of LED-TV SMPS. In case of high frequency type CM choke coil, it can be explained the parasitic capacitance of A type and section bobbin type winding methods among them is much smaller than the other. The first resonant frequency of the proposed CM choke coil tends to increase as the parasitic capacitance becomes small and its impedance characteristics also show improved performance as the first resonant frequency increases. In case of hybrid choke coil using rectangular copper wire, it has investigated its parasitic capacitance compared to CM choke coil of conventional toroidal type becomes small. Also it has confirmed through the experiment results that CE margin and RE margin in frequency bands 0.5MHz to 5MHz and 30MHz to 200MHz are respectively 10dB and 15dB greater than that of conventional type in case of one stage EMI filter structure adopting hybrid choke coil compared to two stage EMI Filter structure using two of each CM choke coil used in the lower and higher frequency bands or two of CM choke coil used in only the lower frequency bands. In the future, the hybrid choke coil and CM choke coil of high frequency type show it can be practically used in not only LED/LCD-TV SMPS but also several applications such as LED Lighting, Laptop Adapter, Server Power Supply and so on.

감쇠파 고주파전압의 선행방전을 이용한 Plasma jet의 전기적 기동특성에 대한 실험적 연구 (The Experimental Research On The Electrical Characteristics For The Ignition Of Plasma Jet Using The Advance Discharge Of High Frequency Voltage With Attenuation)

  • 전춘생
    • 전기의세계
    • /
    • 제21권4호
    • /
    • pp.27-38
    • /
    • 1972
  • This paper discusses the characteristics about the ignition of D.C. main discharge is a plasma jet generator, manufactured for trial as non-transferred type, when the electrical energy appropriate to the ignition is supplied to the gap between the electrodes by using advance discharge of attenuating high frequency voltage generated by a high frequency oscillator with mercury spark gap. These characteristics are under the influences of (a) the length of mercury gap in high frequency oscillator and the quantity of hydrogen flow supplied to it, (b) the condenser capacity of the high frequency oscillator circuit, (c) the length of plasma jet torch in D.C. main discharge circuit and the quantity of argon flow supplied to it, (d) the circuit constants of D.C. main discharge circuit. The results for these characteristics, obtained by this research, are considered to be helpful to the designs for the ignition of a plasma jet as well as the welding arc stabilizer by high frequency discharge and the high frequency arc welder.

  • PDF

시간 지연 요소를 이용한 PI 제어기 자동 동조 알고리즘 (An Auto-tuning Algorithm of PI Controller Using Time Delay Element)

  • 오승록
    • 전자공학회논문지SC
    • /
    • 제47권6호
    • /
    • pp.1-5
    • /
    • 2010
  • 본 논문에서는 PI 제어기를 설계해야 하는 경우인 임계 주파수 부근에서 이득 감소가 적은 시스템을 구별할 수 있는 알고리즘을 제안하였다. 임계 주파수 부근에서 이득감소가 적은 시스템을 구별하기 위해 시간 지연 요소를 이용하여 이득 감소율을 구하는 방법을 제안하였다. 또한 크기 마진과 위상 마진이 주어진 경우 PI 제어기를 설계하는 방법을 제안하였다. 제안된 알고리즘은 시간 지연요소와 포화함수를 이용하여 PI 제어가 가능한 한점의 좌표값을 계산하는 방법을 사용하였다. 제안된 방법은 시뮬레이션을 통해 타당성을 검증하였다.

해저탐사에 적용되는 음파특성 (Underwater Acoustic Characteristics and Application to Seabed Survey)

  • 김성렬;이용국;정백훈
    • 한국석유지질학회지
    • /
    • 제12권1호
    • /
    • pp.14-19
    • /
    • 2006
  • 광파 (또는 전자파)는 물에서 전달에너지의 감쇠 (attenuation)가 너무 심하여 수층을 투과하는데 한계가 있지만 음파의 경우는 매우 좋은 전달매체로 작용한다. 따라서 수중 또는 해저탐사에 사용되는 대부분의 탐사장비와 기술들은 음파를 이용하는 방법을 채택하고 있다. 일반적으로 파동의 특성은 주파수에 있다. 음원 (sound source)이 저주파일수록 투과력 (penetration)은 높아지지만 해상력 (resolution)은 낮아진다. 고주파의 경우는 그 반대이다. 즉 저주파는 바다 깊은 (또는 먼) 곳까지의 정보를 알 수 있지만 해상력은 낮다. 그러나 고주파는 깊이 (또는 멀리)까지는 도달할 수 없지만 얕은 (또는 가까운)곳의 정보는 저주파보다 훨씬 상세한 정보를 제공한다. 해저자원조사에 적용되는 음파탐사방법은 여러 가지가 있으나, 본 논의에서는 해저지형을 조사하는 음향측심, 지층구조와 퇴적층의 형태를 조사하는 지층탐사, 그리고 해저면을 평면적 영상으로 표현하는 측면주사음향탐사, 이 세 가지를 중심으로 해저탐사에 적용되는 음파특성을 논의하였다.

  • PDF