• Title/Summary/Keyword: High Dose Rate

Search Result 888, Processing Time 0.032 seconds

The Effect of Steroid Therapy for Idiopathic Unilateral Vocal Cord Palsy (특발성 일측성 성대마비에서 경구 스테로이드 요법의 효과)

  • Bae, Jong-Won;Lee, GilJoon
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.30 no.2
    • /
    • pp.107-111
    • /
    • 2019
  • Background and Objectives Idiopathic unilateral vocal fold paralysis (IVFP) is believed to be due to inflammation and edema of the recurrent laryngeal nerve caused by viral diseases such as upper respiratory tract infections. Corticosteroid has a potent anti-inflammatory action which should minimize nerve damage. The purpose of this study was to investigate the effect of oral steroid therapy on IVFP. Materials and Method Study was performed for the IVFP patient from January 2012 to August 2017. Patient's dermography, direction and location of paralyzed vocal cords, history of hypertension, diabetes, cerebrovascular disease, and other underlying disease, smoking history, alcohol consumption and upper respiratory tract infection, and symptoms were investigated. Treatment was divided into three groups: the observation group, low-dose group, and high-dose group, and the recovery rate and time of vocal cord paralysis were analyzed in each group. Results Thirty-seven patients were enrolled in this study. There was no relationship between oral steroid use, dosage and recovery of vocal cord paralysis. Oral steroids showed a rapid recovery of vocal cord paralysis, but there was no statistically significant difference in the time of recovery of vocal palsy with or without steroids (p=0.673). In addition, there was no statistically significant difference in recovery rate between the period to start of treatment, presence of diabetes mellitus, and treatment modality, but the recovery rate was high in the group with upper respiratory tract infection history (p=0.041). Conclusion In IVFP, oral steroid therapy has no significant difference in time and extent of recovery compared to the case of spontaneous recovery.

A Case of Radiation Bronchitis Induced Massive Hemoptysis after High-Dose-Rate Endobronchial Brachytherapy

  • Lee, Seok Jeong;Lee, Jong-Young;Jung, Soon Hee;Lee, Shun Nyung;Lee, Ji-Ho;Kim, Chong Whan;Jung, Saehyun;Jung, Ye-Ryung;Lee, Won-Yeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.73 no.6
    • /
    • pp.325-330
    • /
    • 2012
  • High-dose-rate endobronchial brachytherapy (HDREB) have been used as the treatment of early endobronchial cancer, as well as for palliation of advanced cancer. However, fatal hemoptysis can occur after HDREB at the rate of 7~32%. We report a case of massive hemoptysis due to radiation bronchitis developed after HDREB. A 67-year-old man was treated with HDREB for early endobronchial cancer on the left upper lobe bronchus. He complained of persistent cough from 4 weeks after completion of HDREB. Radiation bronchitis was observed on the bronchoscopy at 34 weeks, and it was progressed from mucosal swelling and exudate formation to necrosis and ulceration without local relapse. In addition, he died of massive hemoptysis after 15 months. The patient had no sign or radiologic evidences to predict the hemoptysis. This case implies that HDREB directly contributes to an occurrence of a fatal hemoptysis, and follow-up bronchoscopy is important to predict a progression of radiation bronchitis and fatal hemoptysis.

Radioresistance of Acorus calamus to Gamma Ray Irradiation

  • Lee, Ja-Hyun;Kang, Si-Yong;Lee, Geung-Joo;Lee, Seong-Gene;Kim, Sun-Kook;Han, Tae-Ho
    • FLOWER RESEARCH JOURNAL
    • /
    • v.19 no.2
    • /
    • pp.119-125
    • /
    • 2011
  • Acorus calamus is an indigenous hydrophyte used as phytoremediation and water purification as well as medicinal herb. Irradiation of gamma ray was performed to investigate the effect on radioresistance of A. calamus on in vitro. Various doses (20-500 Gy) of gamma rays were irradiated to in vitro plantlets. The effect of irradiation was studied on survival rate, shoot formation and growth rate. The survival and multiplication rate was remarkably decreased with the increase of radiation dose. The growth of plantlets was significantly increased in comparison to the control at low doses. The hermetic effect of radiation was appeared in A. calamus. It was significantly decreased or interrupted above 250 Gy. The mean 50% lethal dose ($LD_{50}$) was extremely high as 240 Gy. We conclude that A. calamus had remarkably high radioresistance compared with other plant species.

A detector system for searching lost γ-ray source

  • Khan, Waseem;He, Chaohui;Cao, Yu;Khan, Rashid;Yang, Weitao
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1524-1531
    • /
    • 2020
  • The aim of this work is to develop a Geiger-Muller (GM) detector system for robot to look for a radioactive source in case of a nuclear emergency or in a high radiation environment. In order to find a radiation source easily, a detector system, including 3 detectors, was designed to search γ-ray radiation sources autonomously. First, based on GEANT4 simulation, radiation dose rates in 3 Geiger-Muller (GM) counters were simulated at different source-detector distances, distances between detectors and angles. Various sensitivity analyses were performed experimentally to verify the simulated designed detector system. A mono-energetic 137Cs γ-ray source with energy 662 keV and activity of 1.11 GBq was used for the observation. The simulated results were compared with the experimental dose rate values and good agreements were obtained for various cases. Only based on the dose rates in three detectors, the radiation source with a specific source activity and angle was localized in the different location. A method was adopted with the measured dose rates and differences of distances to find the actual location of the lost γ-ray source. The corresponding angles of deviation and detection limits were calculated to determine the sensitivity and abilities of our designed detector system. The proposed system can be used to locate radiation sources in low and high radiation environments.

FK506 immunosuppression for submandibular salivary gland allotransplantation in rabbit

  • Almansoori, Akram Abdo;Khentii, Namuun;Ju, Kyung Won;Kim, Bongju;Kim, Soung Min;Lee, Jong-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.3
    • /
    • pp.197-203
    • /
    • 2020
  • Objectives: We compared the outcomes of two different doses of FK506 (tacrolimus) for immunosuppression in submandibular salivary gland (SMG) allotransplantation. Materials and Methods: Three SMG allotransplantation groups were established (n=6 per group) as follows: allograft rejection control (Allo-Ctrl), low dose (0.08 mg/kg) of FK506 (FK506-L), and high dose (0.16 mg/kg) of FK506 (FK506-H). Allograft survival and rejection were assessed by clinical observation, interleukin-2 levels as determined by enzyme-linked immunosorbent assay, blood sampling for complete blood count (CBC), and histological evaluation. Results: Body weight and anorexia were higher in the FK506-H group but without a significant difference compared with the FK506-L population. CBC revealed a non-significantly reduced number of changes in the FK506-L group. Four glands in the FK506-H group and two glands in the FK506- L group were viable and functioning post-transplantation. Conclusion: The survival rate of allotransplanted glands was higher in conjunction with the high dose of 0.16 mg/kg of FK506, with no major difference in the side-effect profile when compared with the low dose of 0.08 mg/kg short-term outcomes.

A Study on Dosimetry for Small Fields of Photon Beam (광자선 소조사면의 선량 측정에 관한 연구)

  • 강위생;하성환;박찬일
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.57-68
    • /
    • 1994
  • Purpose : The purposes are to discuss the reason to measure dose distributions of circular small fields for stereotactic radiosurgery based on medical linear accelerator, finding of beam axis, and considering points on dosimetry using home-made small water phantom, and to report dosimetric results of 10MV X-ray of Clinac-18, like as TMR, OAR and field size factor required for treatment planning. Method and material : Dose-response linearity and dose-rate dependence of a p-type silicon (Si) diode, of which size and sensitivity are proper for small field dosimetry, are determined by means of measurement. Two water tanks being same in shape and size, with internal dimension, 30${\times}$30${\times}$30cm$^3$ were home-made with acrylic plates and connected by a hose. One of them a used as a water phantom and the other as a device to control depth of the Si detector in the phantom. Two orthogonal dose profiles at a specified depth were used to determine beam axis. TMR's of 4 circular cones, 10, 20, 30 and 40mm at 100cm SAD were measured, and OAR's of them were measured at 4 depths, d$\sub$max/, 6, 10, 15cm at 100cm SCD. Field size factor (FSF) defined by the ratio of D$\sub$max/ of a given cone at SAD to MU were also measured. Result : The dose-response linearity of the Si detector was almost perfect. Its sensitivity decreased with increasing dose rate but stable for high dose rate like as 100MU/min and higher even though dose out of field could be a little bit overestimated because of low dose rate. Method determining beam axis by two orthogonal profiles was simple and gave 0.05mm accuracy. Adjustment of depth of the detector in a water phantom by insertion and remove of some acryl pates under an auxiliary water tank was also simple and accurate. TMR, OAR and FSF measured by Si detector were sufficiently accurate for application to treatment planning of linac-based stereotactic radiosurgery. OAR in field was nearly independent of depth. Conclusion : The Si detector was appropriate for dosimetry of small circular fields for linac-based stereotactic radiosurgery. The beam axis could be determined by two orthogonal dose profiles. The adjustment of depth of the detector in water was possible by addition or removal of some acryl plates under the auxiliary water tank and simple. TMR, OAR and FSF were accurate enough to apply to stereotactic radiosurgery planning. OAR data at one depth are sufficient for radiosurgery planning.

  • PDF

Study of Radiation dose Evaluation using Monte Carlo Simulation while Treating Extrahepatic Bile Duct Cancer with High Dose Rate Intraluminal Brachytherapy (간외 담도암 고선량률 관내근접방사선치료 시 몬테카를로 시뮬레이션을 통한 주변장기의 선량평가 연구)

  • Park, Ju-Kyeong;Lee, Seung-Hoon;Cha, Seok-Yong;Lee, Sun-Young
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.2
    • /
    • pp.467-474
    • /
    • 2014
  • The relative dose calculated by MCNPX and the relative dose measured by ionization chamber and solid phantoms evaluated the accuracy comparing with Monte Carlo simulation. In order to apply Monte Carlo simulation the intraluminal brachytherapy of extrahepatic bile duct cancer, 192Ir sealed radioactive source replicate, Bile duct and surrounding organs were made using KMIRD phantom based on a South Korea standard man. To check the absorbed dose of normal organs around bile duct, we set the specific effective energy and initial radioactivity to 1 Ci using MCNPX. Evaluation of the accuracy of the Monte Carlo simulation, the difference of the relative dose is the most 1.96% that satisfy the criteria that is the relative error less than 2% suggested by MCNPX code. In addition, The specific effective energy and absorbed dose of normal organs that were relatively adjacent to bile duct such as right side of kidney, liver, pancreas, transverse colon, spinal cord, stomach and small intestine were relatively high. on the contrary, the organs that were relatively distant to bile duct such as left side of kidney, spleen, ascending colon, descending colon and sigmoid colon were relatively low.

Development of Film Verification as the QA of IMRT for Advanced Hepatoma Patients (간암 환자의 세기조절 방사선치료에서 임상적응 가능한 QA 기법의 개발)

  • Kim Myung-Se
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.40-46
    • /
    • 2006
  • Hepatoma is one of 3 most common malignancies in Korea, the survival rate is not improved since last decades because of delayed diagnosis and limited treatment conditions. Radiation was one of treatment options but the impact on the survival is not remarkable. High dose exposure to target area was suggested for improved effect but low tolerance dose of normal liver tissue is the main limited factor. IMRT is the advanced form of 3DCRT, for focusing high dose on target with minimal dose to surrounding normal tissues. Motion of the tumor by respiration, cardiac pulsation and peristalsis is the main treatment harrier of IMRT for treatment of hepatoma patients. Development of QA technique for acceptable geometrical uncertainties and dose error on target volume is essential for IMRT in clinical treatment but proper QA technique is not yet developed. This study compared the verification film dosimetry with measured dose in phantom and calculated dose in planning computer on exactly same conditions of patient treatments. Within 3% dose differences between 3 groups were confirmed. We suggest that our verification QA technique is easy, economic, iterative and acceptable in clinical application for advanced hepatoma patients.

  • PDF

Development of a cylindrical ultrasound applicator for Intracavitary Hyperthermia (강내온열 치료를 위한 원통형 초음파 치료기 개발)

  • Lee, Rena J.;Hyunsuk Suh
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.79-84
    • /
    • 2002
  • In this study, a cylindrical ultrasound applicator is developed for the treatment of vagina and rectum in combination with high dose rate brachytherapy. A cylindrical transducer (PZT-8, 1=1.5 cm, thickness=1.5mm OD=2.5 cm) was used as an energy source for induction of hyperthermia. Three single-element applicators were constructed to examine the performance of the PZT material. Vector impedance was measured to determine driving frequency. The efficiencies of the elements were determined using a radiation force technique to evaluate the feasibility of using the applicator as a hyperthermia source. A multi-element ultrasound applicator was designed using the PZT-8 material for the treatment of vagina. Results from the vector impedance measurements showed maximum magnitude at 1.78, 1.77, and 1.77 MHz for applicator 1,2, and 3, respectively. The radiation force measurements showed that the acoustic power of 40 watts was obtained in all three elements. The average efficiencies of the elements were 61.4, 65.2, and 54.0% for element 1, 2, and 3, respectively. The designed ultrasound hyperthermia applicator could be used in combination with high dose rate brachytherapy for the treatment of vagina and rectum. The use of this applicator with intracavitary brachytherapy could offer improved tumor control by increasing radiosensitiyity of the tumor.

  • PDF

Degradation Properties of Ibuprofen Using Photocatalytic Process (광촉매 공정에 따른 이부프로펜의 분해 특성)

  • Cai, Jin-Hua;Na, Seung-Min;Ahn, Yun-Gyong;Lee, Se-Ban;Khim, Jee-Hyeong
    • Journal of Environmental Science International
    • /
    • v.21 no.4
    • /
    • pp.411-419
    • /
    • 2012
  • In this study, Ibuprofen (IBP) degradation by the photo catalytic process was investigated under various parameters, such as UV intensity, optimum dosage of $TiO_2$, alkalinity, temperature and pH of bulk solution. The pseudo-first order degradation rate constants were in the order of $10^{-1}$ to $10^{-4}min^{-1}$ depending on each condition. The Photocatalytic IBP degradation rate increased with an increase in the applied UV power. At high UV intensity a high rate of tri-iodide ($I_3{^-}$) ion formation was also observed. Moreover, in order to avoid the use of an excess catalyst, the optimum dosage of catalyst under the various UV intensities (30 and 40 W/L) was examined and ranged from approximately 0.1 $gL^{-1}$. The photo catalytic IBP degradation rate was changed depending on the alkalinity and temperature and pH in the aqueous solution. This study demonstrated the potential of photo catalytic IBP degradation under different conditions.