• Title/Summary/Keyword: HgO

Search Result 510, Processing Time 0.03 seconds

A Novel Technology for Recycling Waste Dry-battery

  • Chen, Weiliang;Chai, Liyuan;Min, Xiaobo;Zhang, Chuanfu
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.249-251
    • /
    • 2001
  • A novel technology for recycling valuable metals contained in waste dry-battery by vacuum metallurgy was devised by theoretical analysis. On the condition of the total chamber pressure of 1.013$\upsilon$10$^1$Pa, Hg, Cd and Zn are distilled in the temperature range of 773~973K, Pb is volatilized in the range of 1173~1273K while Mn, Cu, Fe and C are remained in residual. MnO$_2$and ZnO are reduced by carbon in waste dry-battery in 773~1273K. Pure metals including Zn, Cd, Hg and Pb can be recovered respectively from their mixed vapor by fractional condensation. Metal Cu and MnO$_2$can be obtained from the residual by hydrometallguical method. The technology can eliminate the pollution of Cd, Hg and Pb to environment.

  • PDF

The Respiratory and Hemodynamic Effects of Prone Position According to the Level of PEEP in a Dog Acute Lung Injury Model (잡종견 급성폐손상 모델에서 Prone position 시행시 PEEP 수준에 따른 호흡 및 혈류역학적 효과)

  • Lim, Chae-Man;Chin, Jae-Yong;Koh, Youn-Suck;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.140-152
    • /
    • 1998
  • Background: Prone position improves oxygenation in patients with ARDS probably by reducing shunt Reduction of shunt in prone position is thought to be effected by lowering of the critical opening pressure (COP) of the dorsal lung because the pleural pressure becomes less positive in prone position compared to supine position. It can then be assumed that prone position would bring about greater improvement in oxygenation when PEEP applied in supine position is just beneath COP than when PEEP is above COP. Hemodynamically, prone position is expected to attenuate the lifting of cardiac fossa induced by PEEP. Based on these backgrounds, we investigated whether the effect of prone position on oxygenation differs in magnitude according to the level of PEEP applied in supine position, and whether impaired cardiac output in supine position by PEEP can be restored in prone position. Methods: In seven mongrel dogs, $PaO_2/F_1O_2$(P/F) was measured in supine position and at prone position 30 min. Cardiac output (CO), stroke volume (SV), pulse rate (PR), and pulmonary artery occlusion pressure (PAOP) were measured in supine position, at prone position 5 min, and at prone position 30 min. After ARDS was established with warmed saline lavage(P/F ratio $134{\pm}72$ mm Hg), inflection point was measured by constant flow method($6.6{\pm}1.4cm$ $H_2O$), and the above variables were measured in supine and prone positions under the application of Low PEEP($5.0{\pm}1.2cm$ $H_2O$), and Optimal PEEP($9.0{\pm}1.2cm$ $H_2O$)(2 cm $H_2O$ below and above the inflection point, respectively) consecutively. Results : P/F ratio in supine position was $195{\pm}112$ mm Hg at Low PEEP and $466{\pm}63$ mm Hg at Optimal PEEP(p=0.003). Net increase of P/F ratio at prone position 30 min, however, was far greater at Low PEEP($205{\pm}90$ mm Hg) than at Optimal PEEP($33{\pm}33$ mm Hg)(p=0.009). Compared to CO in supine position at Optimal PEEP($2.4{\pm}0.5$ L/min), CO in prone improved to $3.4{\pm}0.6$ L/min at prone position 5 min (p=0.0180) and $3.6{\pm}0.7$ L/min at prone position 30 min (p=0.0180). Improvement in CO was attributable to the increase in SV: $14{\pm}2$ ml in supine position, $20{\pm}2$ ml at prone position 5 min (p=0.0180), and $21{\pm}2$ ml at prone position 30 min (p=0.0180), but not to change in PR or PAOP. When the dogs were turned to supine position again, MAP ($92{\pm}23$ mm Hg, p=0.009), CO ($2.4{\pm}0.5$ L/min, p=0.0277) and SV ($14{\pm}1$ ml, p=0.0277) were all decreased compared to prone position 30 min. Conclusion: Prone position in a dog with saline-lavaged acute lung injury appeared to augment the effect of relatively low PEEP on oxygenation, and also attenuate the adverse hemodynamic effect of relatively high PEEP. These findings suggest that a PEEP lower than Optimal PEEP can be adopted in prone position to achieve the goal of alveolar recruitment in ARDS avoiding the hemodynamic complications of a higher PEEP at the same time.

  • PDF

Kinetic Study for Aquation of $cis-[Co(en)_2(NH_3)Cl]^{2+}$ in $Hg^{2+}$ Aqueous Solution ($Hg^{2+}$수용액에서 $cis-[Co(en)_2(NH_3)Cl]^{2+}$의 아쿠아반응에 대한 속도론적 연구)

  • Byung-Kak Park;Gil-Jun Lee;Jae-Weon Lee;Joo-Sang Lim
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.3
    • /
    • pp.227-232
    • /
    • 1988
  • A kinetic study was made to determine the mechanism of the aquation of $cis-[Co(en)_2(NH_3)Cl]^{2+}\;in\;Hg^{2+}$ aqueous solution. The progress of reaction was followed UV/vis-spectrophotometrically by a measurement of the absorbance at a specific wave length (530nm) of $cis-[Co(en)_2(NH_3)Cl]^{2+}$ as a function of time. The experimental results have shown that the reaction rate is dependent upon the concentration of $Hg^{2+}$ that act as a catalyst. And it was found that the overall reaction proceed with second order, first order with respect to Co(III) complex and $Hg^{2+}$. Activation parameters, ${\Delta}H^{\neq}\;and\;{\Delta}S^{\neq}$, were obtained as 12.9 kcal/mol and -19.3 e.u., respectively. We have proposed a plausible reaction mechanism which is consistent with the observed rate equation.

  • PDF

Electrochemical Oxidation of Hydrogen at Palladium Electrode (팔라디움 전극에서의 전기화학적 수소산화반응)

  • Oh, M.H.;Paik, C.H.;Cho, B.W.;Yun, K.S.;Min, B.C.;Ju, J.B.;Sohn, T.W.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.7 no.1
    • /
    • pp.45-54
    • /
    • 1996
  • Electrochemical oxidation of hydrogen on PdOx and Pd electrodes were investigated in aqueous 30% KOH solution at different temperatures and hydrogen concentrations(partial pressures). Anodic reaction by hydrogen on PdOx electrode was mainly due to the oxidation of adsorbed hydrogen at -0.8V~-0.5V(vs. Hg/HgO). For Pd electrode, the anodic reaction was participated by the adsorbed hydrogen on surface, as well as by the metal hydride formed from direct reaction between Pd and hydrogen at -0.5V~0.0V(vs. Hg/HgO). With the increase of hydrogen concentration the charge transfer resistance decreased and the exchange current increased. The transfer coefficient of PdOx and Pd electrodes were found to be 0.78 and 0.72 respectively, which shows the superior reactivity of Pd electrode. The activation energies of PdOx and Pd electrodes decreased with the increase of overpotential and were found to be 23.9~20.3 kJ/mole and 7.2~3.0kJ/mole, respectively.

  • PDF

Respiratory Assist by Use of Electrical Diaphragmatic Pacing (전기자극에 의한 횡격막 조율을 이용한 호흡보조장치)

  • 오중환;김은기;서재정;박일환;김부연;이상헌;이종국;이영희
    • Journal of Chest Surgery
    • /
    • v.34 no.6
    • /
    • pp.441-446
    • /
    • 2001
  • Background: Electrical breathing pacing has many advantages over mechanical ventilation. However, clinically permanent diaphragmatic pacing has been applied to limited patients and few temporary pacing has been reported. Our purpose is to investigate the feasibility of temporary electrical diaphragm pacing in explothoracotomy canine cases. Methods: Five dogs were studied under the general anesthesia. Left 5th intercostal space was opened. Self designed temporary pacing leads were placed around the left phrenic nerve and connected to the myostimulator. Chest wall was closed after tube insertion with underwater drainage. Millar catheter was introduced to the aorta and right atrium. Swan-Ganz catheter was introduced to the pulmonary artery. When the self respiration was shallow with deep anesthesia, hemodynamic and tidal volume were measured with the stimulator on. Results: Tidal volume increased from 143.3$\pm$51.3 ml to 272.3$\pm$87.4 ml(p=0.004). Right atrial diastolic pressure decreased from 0.7$\pm$4.0 mmHg to -10.5$\pm$4.7 mmHg(p=0.005). Pulmonary arterial diastolic pressure decreased from 6.1+2.5 mmHg to 1.2$\pm$4.8 mmHg(p<0.001). The height of water level in chest tube to show intrathoracic pressure change was from 10.3$\pm$6.7cmH$_{2}$O to 20.0$\pm$5.3 cmH$_{2}$O. Conclusion: Temporary electrical diaphragmatic pacing is a simple method to assist respiration in explothoracotomy canine cases. Self designed pacing lead is implantable and removable. Negative pressure ventilation has favorable effects on the circulatory system. Therefore, clinical application of temporary breathing pacing is feasible in thoracotomy patients to assist cardiorespiratory function.

  • PDF

Effects of Inspiratory Pressure Preset on Alveolar Gas Exchange Using Anesthetic Ventilator (전시마취시 흡입압력기준의 양압조절호흡이 폐포환기 정도에 미치는 영향)

  • Suh, III-Soak;Kang, Hee-Ju;Kim, Heung-Dae
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.1
    • /
    • pp.105-110
    • /
    • 1988
  • The study was undertaken to determine the most adequate tidal volume when used volume preset ventilator during anesthesia. The thirty patients were received controlled mechanical ventilation with constant inspiratory pressure of 10cmH2O and respiratory frequency of 12/minute. The results were as follows : 1) The PH was $7.39{\pm}0.01$ and it is within normal limit. 2) The $PaCO_2$ was $34.0{\pm}0.6$ mmHg and it is a slightly hyperventilatory state. 3) The $PaO_2$ was $228.0{\pm}8.2$ mmHg. 4) The Buffer base was $20.7{\pm}0.3mEql$ and it is a slightly buffer base deficient state. From the above results. We concluded that if patients were fully relaxed during general anesthesia, it is desirable to maintain the inspiratory pressure of anesthetic mechanical ventilator to $10cmH_2O$ for adeguate alveolar ventilation.

  • PDF

Transcutaneous Oxygen Pressure to Predict Wound Healing in Mild Diabetic Feet (경증의 당뇨발에서 창상치유 예측인자로서의 경피산소분압치)

  • Jang, Seo-Yoon;Jeong, Tae-Won;Han, Seung-Kyu;Kim, Woo-Kyung
    • Archives of Plastic Surgery
    • /
    • v.38 no.5
    • /
    • pp.585-589
    • /
    • 2011
  • Purpose: Microcirculation of diabetic patients is commonly comporomised, regardless of the condition of the macrocirculation. Therefore, direct tissue oxygenation measurement is recommended in determining tissue viability and predicting wound healing potential. This study was designed to determine cut-off value of the tissue oxygenation in predicting wound healing in diabetic foot patients. Methods: This study included 41 feet of 41 diabetic foot patients who were treated in the Diabetic Wound Center of author's institution between January and June, 2009. Main inclusion criteria were type 1 or 2 diabetes and a foot ulcer (duration > 3 weeks) and ulcer area (from 1 $cm^2$ to 4 $cm^2$). Measurements of the area of diabetic foot ulcer were carried out before treatment. Transcutaneous oxygen pressure ($TcpO_2$) was measured at adjacent site of ulcer. The healing wound was defined as complete wound closure within 12 weeks. Results: Average diabetic foot ulcer areas with healing and nonhealing wounds were $2.67{\pm}0.76$ and $2.59{\pm}0.75\;cm^2$, respectively. There was no significant difference in the wound area between the groups. Average foot $TcpO_2$ in healing and nonhealing wounds were $68.56{\pm}23.07$ and $30.98{\pm}16.66$ mmHg, respectively ($p$ <0.01). The rate of healing wound increased as $TcpO_2$ increased. In particular, $TcpO_2$ lower than 40 mmHg and higher than 40 mmHg showed the most significant difference (wound healing rates of 25% and 71%, respectively). Conclusion: Based on the results of the study, the minimal $TcpO_2$ value thought to be required for adequate wound healing in diabetic wounds (cut-off value) is 40 mmHg.

MERCURY-INDUCED ALTERATIONS OF CHLOROPHYLL a FLUORESCENCE KINETICS IN ISOLATED BARLEY (Hordeum vulgare L. cv. ALBORI) CHLOROPLASTS

  • Chun, Hyun-Sik;Lee, Choon-Hwan;Lee, Chin-Bum
    • Journal of Photoscience
    • /
    • v.1 no.1
    • /
    • pp.47-52
    • /
    • 1994
  • Effects of HgCl$_2$-treatment on electron transport, chlorophyll a fluorescence and its quenching were studied using isolated barley (Hordeum vulgare L. cv. Albori) chloroplasts. Depending on the concentration of HgCI$_2$, photosynthetic oxygen-evolving activities of photosystem II (PS II) were greatly inhibited, whereas those of photosystem I (PS I) were slightly decreased. The inhibitory effects of HgCl$_2$ on the oxygen-evolving activity was partially restored by the addition of hydroxyamine, suggesting the primary inhibition site by HgCl$_2$2-treatment is close to the oxidizing site of PS tl associated with water-splitting complex. Addition of 50 $\mu$M HgCI$_2$ decreased both photochemical and nonphotochemical quenching of chlorophyll fluorescence. Especially, energy dependent quenching (qE) was completely disappeared by HgCl$_2$-treatment as observed by NH$_4$CI treatment. In the presence of HgCI$_2$, F'o level during illumination was also increased. These results suggest that pH gradient across thylakoid membrane can not be formed in the presence of 0 $\mu$M HgCl$_2$. In addition, antenna pigment composition might be altered by HgCl$_2$-treatment.

  • PDF

Effect of some reagents added in culture media upon the mycelial growth of the Psallitoa Campestris (Psalliota Campestris의 균사생장(菌絲生長)에 미치는 무기염류(無機鹽類)의 영향(影響))

  • Yu, Tae-Jong
    • Applied Biological Chemistry
    • /
    • v.6
    • /
    • pp.57-59
    • /
    • 1965
  • According to the result of the observations on the effect of the reagents, $CuSO_4{\cdot}5H_2O$, $ZnSO_4{\cdot}7H_2O$ $MnSO_4{\cdot}4H_2O$, $HgCl_2$, upon the mycelial growth of psalliota campestris $HgCl_2$ showed the strongest effect on checking the mycelial growth $(,.008{\sim}0.01%)$ $CuSO_4{\cdot}5H_2O(0.030%)$, $ZnSO_4{\cdot}7H_2O(0.080%)$, came next and the $MnSO_4{\cdot}4H_2O(0.100%)$ was the weakest. Writer also found that showed the promoting effect of the mycelial growth in appropriate Concentration (at $0.015%\;CuSO_4{\cdot}5H_2O$, $0.030%ZnSO_4{\cdot}7H_2O$).

  • PDF

The Fabrication and Evaluation of HgI2 Semiconductor Detector as High Energy X-ray Dosimeter Application (고에너지 X선 선량계 적용을 위한 TiO2 첨가된 요오드화수은 반도체 검출기 제작 및 평가)

  • Choi, Il Hong;Noh, Sung Jin;Park, Jung Eun;Park, Ji Koon;Kang, Sang Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.383-387
    • /
    • 2014
  • In this paper, for a new detection system development with the better accurate dose evaluation and beam distribution imaging using the small field irradiation of linear accelerator, the compound semiconductor based detection sensors were fabricated and the performance evaluation was investigated. The special particle-in-binder sedimentation was used for a large area film sensor fabrication. The detection properties for high energy x-rays were investigated from a dark current, an output current, a rising time, a falling time, and response delay measurement. The experimental results, the $TiO_2$ mixed $HgI_2$ sensor showed the best electrical characteristics than $PbI_2$, PbO, pure $HgI_2$. Linearity, repeatability, and accuracy tests from LINAC were tested, the $TiO_2$ mixed $HgI_2$ sensor showed the better performance than the commercially available dosimetry devices.