Journal of Yeungnam Medical Science
- Volume 5 Issue 1
- /
- Pages.105-110
- /
- 1988
- /
- 2799-8010(eISSN)
Effects of Inspiratory Pressure Preset on Alveolar Gas Exchange Using Anesthetic Ventilator
전시마취시 흡입압력기준의 양압조절호흡이 폐포환기 정도에 미치는 영향
- Suh, III-Soak (Department of Anesthesiology, College of Medicine, Yeungnam University) ;
- Kang, Hee-Ju (Department of Anesthesiology, College of Medicine, Yeungnam University) ;
- Kim, Heung-Dae (Department of Anesthesiology, College of Medicine, Yeungnam University)
- Published : 1988.06.30
Abstract
The study was undertaken to determine the most adequate tidal volume when used volume preset ventilator during anesthesia. The thirty patients were received controlled mechanical ventilation with constant inspiratory pressure of 10cmH2O and respiratory frequency of 12/minute. The results were as follows : 1) The PH was
흡입전신마취시에 마취호흡기를 사용할 겨우 환자에게 가장 적절한 1회 호흡량을 흡입시킬수 있는 방법을 알아보기 위하여 전신마취환자 30명에서 흡입기압력
Keywords