• 제목/요약/키워드: HgO

검색결과 512건 처리시간 0.03초

Preparation and Characterization of a Surface Renewable Solid State Hg/HgO Reference Electrode Utilizing Gold Amalgam

  • Kim, Won;Park, Jong-Man
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권3호
    • /
    • pp.439-442
    • /
    • 2007
  • A solid state Hg(Au)/HgO reference electrode was prepared utilizing gold amalgam solid particles. Solid fine powder of the gold amalgam was prepared by chemical reduction of Au(III) with NaBH4 followed by reduction of Hg(II) in the presence of gold fine particles. The solid content in the suspension of the gold amalgam particles and fine mercury oxide particles in DMF containing PVC was precipitated by the addition of a large amount of water to give solid Hg(Au)/HgO/PVC mixture. After drying, the mixture was pressure-molded to a physically stable Hg(Au)/HgO composite reference electrode material. The electrochemical characteristics of the electrode as a reference electrode were very similar to an ordinary Hg/HgO reference electrode. The electrode material can be molded and fabricated in any desired shape and size. The surface can be renewed by a simple polishing process whenever contaminated or deactivated. The applicability of the electrode in the electrochemical detection of carbohydrates after anion exchange separation was evaluated.

ZnO 나노선과 HgTe 나노입자 박막을 이용한 pn 접합 다이오드 (A pn diode constructed with an n-type ZnO nanowire and a p-type HgTe nanoparticle thin film)

  • 성호준;조경아;김상식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.121-121
    • /
    • 2008
  • We propose a novel nanomaterial-based pn diode which constructed with an n-type ZnO nanowire (NW) and a p-type HgTe nanoparticle (NP) thin film. The photo current characteristics of a ZnO NW, a HgTe NP thin film and pn diode constructed with a ZnO NW and a HgTe NP thin film were investigated under illumination of the 325 nm and 633 nm wavelength light. The conductivities of a ZnO NW exposed to the 325 nm and 633 nm wavelength light increased, while the photocurrents taken from the HgTe NP thin film was very close to the dark currents. Moreover, The pn diode exhibited the rectifying characteristics of the dark current and of the photocurrent excited by the 633 nm wavelength light. In contrast, the ohmic characteristics for the photocurrent were observed due to the junction barrier lowering in the conduction band of the ZnO nanowire under the illumination of the 325 nm wavelength light.

  • PDF

國內詞育 원숭이의 血液가스値에 관한 硏究 (Studies on Blood Gas Values in Non-Human Primates Reared in Korea)

  • 윤상보;김덕환;서지민;신남식;현병화;박배근;송희종
    • 한국임상수의학회지
    • /
    • 제18권4호
    • /
    • pp.397-401
    • /
    • 2001
  • Blood gas values such as pO$_2$ were studied in common marmosets, crab-eating macaques and Japanese macaques, rhesus macaques and celebes macaque reared in Korea. Blood pH and blood gas values were evaluated in both arterial and venous blood. pH, p$CO_2$, and pO$_2$, of arterial blood in common marmosets were measured as 7.4$\pm$0.1, 29.2$\pm$3.6 mmHg and 81.5$\pm$8.9 mmHg, respectively. Corresponding values in one crab-eating macaque were 7.3, 41.3 mmHg and 46.5 mmHg, respectively. In case of venous blood, pH, p$CO_2$, and pO$_2$, in common marmosets were observed as 7.2$\pm$0.2, 64.9$\pm$18.3 mmHg and 23.5$\pm$5.4 mmHg, respectively. On the while, pH, p$CO_2$, and pO$_2$, of venous blood in crab-eating macaques showed 7.2$\pm$0.2, 49.9$\pm$8.0 mmHg and 38.3$\pm$8.8 mmHg, respectively. Venous pH, p$CO_2$, and pO$_2$, in Japanese macaques were 7.1$\pm$0.2, 56.4$\pm$5.3 mmHg and 40.1$\pm$9.3 mmHg, respectively. Those values in one rhesus macaque were 7.2, 61.1 mmHg and 24.9 mmHg, and in celebes macaque were 7.1, 54.3 mmHg and 31.8 mmHg, respectively.

  • PDF

세라믹 선재의 전기 구조적 특성

  • 이상헌;이영희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.54-56
    • /
    • 2005
  • Fabrication of c-axis oriented $(Hg_{0.75}Rc_{0.25})Ba_2Ca_2Cu_3O_y$ thick fabricated has been attempted using Ni substrates with the buffer layer of Cr or NiO. Coexistence of $(Hg_{0.75}Rc_{0.25})Ba_2Ca_3Cu_4O_y$ pellets wad found to stabilize $(Hg_{0.75}Rc_{0.25})Ba_2Ca_2Cu_3O_y$ phase of the tape. The c-axis oriented tapes were reproducibly obtained on the NiO/Ni substerate and they recorded high $B_{irr}$ at 77K.$(Hg_{0.75}Rc_{0.25})Ba_2Ca_2Cu_3O_y$ 1223.

  • PDF

무기수은과 유기수은의 선택정량 (A Selective Determination Method of Inorganic and Organic Mercury)

  • 김천한
    • 대한화학회지
    • /
    • 제41권8호
    • /
    • pp.392-398
    • /
    • 1997
  • 무기수은과 유기수은을 분리하여 각각을 정량하는 방법을 연구하였다. 고분자량 알킬의 4차아민의 염, Aliquat 336의 $CHCl_3$ 용액을 이용하여 수용액 중에 함유된 무기수은이온, $Hg^{2+}$을 티오시안 착이온으로서, 그리고 유기수은 화합물, $CH_3HgCl$$C_2H_3O_2$ $HgC_6H_5$ 등을 동시에 추출농축한 다음 무기수은은 3 M $HClO_4 $ 용액으로 선택적인 역추출을 하여 CVAAS로 정량하고, 유기수은은 추출액의 $CHCl_3$ 을 증발 제거한 후 그 찌끼를 4% $KMnO_4 $-1M $H_2$$S0_4 $ 용액으로 분해하여 무기수은 이온으로 만들어서 역시 CVAAS로 정량하였다. 시료용액 50 mL 중에 함유된 Hg로서 1 ${\mu}g$의 무기수은과 유기수은 혼합용액(0.02 ${\mu}gHg/mL$)을 분석한 결과 절대오차 ${\pm}6%$ 이내의 결과를 얻었다.

  • PDF

Enhancement and optimization of gamma radiation shielding by doped nano HgO into nanoscale bentonite

  • Allam, Elhassan A.;El-Sharkawy, Rehab M.;El-Taher, Atef;Shaaban, E.R.;RedaElsaman, RedaElsaman;Massoud, E. El Sayed;Mahmoud, Mohamed E.
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.2253-2261
    • /
    • 2022
  • In this study, nano-scaled shielding materials were assembled and fabricated by doping different weight percentages of Nano-mercuric oxide (N-HgO) into Nano-Bentonite (N-Bent) based on using (100-x% N-Bent + x% N-HgO, x = 10, 20, 30, and 40 wt %). The fabricated N-HgO/N-Bent nanocomposites were characterized by FT-IR, XRD, and SEM and evaluated to evaluate their shielding properties toward gamma radiation by using four different γ-ray energies form three point sources; 356 keV from 133Ba, 662 keV from 137Cs as well as 1173, and 1332 keV from 60Co. The γ-rays mass attenuation coefficients were plotted as a function of the doped N-HgO concentrations into N-HgO/N-Bent nanocomposites. The computed values of mass attenuation coefficients (µm), effective atomic number (Zeff) and electron density (Nel) by the as-prepared samples were found to increase, while the half value layer (HVL) and mean free path (MFP) were identified to decrease upon increasing the N-HgO contents. It was concluded also that the increase in N-HgO concentration led to a direct increase in the mass attenuation coefficient from 0.10 to 0.17 cm2/g at 356 keV and from 0.08 to 0.09 cm2/g at 662 keV. However, a slight increase was observed in the identified mass attenuation coefficients at (1172 and 1332 keV).

Adsorption of Mercury(II) Chloride and Carbon Dioxide on Graphene/Calcium Oxide (0 0 1)

  • Mananghaya, Michael;Yu, Dennis;Santos, Gil Nonato;Rodulfo, Emmanuel
    • 한국재료학회지
    • /
    • 제26권6호
    • /
    • pp.298-305
    • /
    • 2016
  • In this work, recent progress on graphene/metal oxide composites as advanced materials for $HgCl_2$ and $CO_2$ capture was investigated. Density Functional Theory calculations were used to understand the effects of temperature on the adsorption ability of $HgCl_2$ and water vapor on $CO_2$ adsorption on CaO (001) with reinforced carbon-based nanostructures using B3LYP functional. Understanding the mechanism by which mercury and $CO_2$ adsorb on graphene/CaO (g-CaO) is crucial to the design and fabrication of effective capture technologies. The results obtained from the optimized geometries and frequencies of the proposed cluster site structures predicted that with respect to molecular binding the system possesses unusually large $HgCl_2$ ($0.1-0.4HgCl_2g/g$ sorbent) and $CO_2$ ($0.2-0.6CO_2g/g$ sorbent) uptake capacities. The $HgCl_2$ and $CO_2$ were found to be stable on the surface as a result of the topology and a strong interaction with the g-CaO system; these results strongly suggest the potential of CaO-doped carbon materials for $HgCl_2$ and $CO_2$ capture applications, the functional gives reliable answers compared to available experimental data.

급성호흡부전증후군에서 Prone Position의 호흡 및 혈류역학적 효과 (The Respiratory and Hemodynamic Effect of Prone Position in Patients with ARDS)

  • 임채만;고윤석;정복현;이상도;김우성;김동순;김원동
    • Tuberculosis and Respiratory Diseases
    • /
    • 제44권5호
    • /
    • pp.1105-1113
    • /
    • 1997
  • 배 경 : 급성호흡부전증후군에서 배측 폐는 복측 폐에 비해 이환 정도가 심하여 기계호흡시 PEEP 사용에도 폐포 모집이 어려운 것이 알려져 있고 이러한 상태에서 prone position은 이환이 심한 배측 폐의 국소 환기를 향상시키고 동맥혈산소분압의 호전을 가져온다는 보고들이 있으나 아직 prone position 의 호흡생리학적 효과나 혈류역학적 효과가 완전히 정립되지 않았다. 방 법 : 급성폐손상 점수 평균 2.5 이상인 ARDS 환자 23명(남 : 여 =11 : 12, 연령 $62.1{\pm}20.8$세)을 대상으로 먼저 supine position에서 호흡 지표로 동맥혈가스분석, 총호흡기계 정적 탄성과 혈류역학적 지표로 평균 동맥압, 분당 심박수 등을 얻은 뒤 prone position으로 전환하였다. Prone position 5분에 동일한 혈류역학적 지표, 0.5 및 2시간에 호흡 지표를 얻었으며, 2시간까지의 $PaO_2/FIO_2$ 비가 supine position에 비해 20mmHg 이상 증가한 경우를 양성 호흡반응, prone 5분의 평균동맥압이 supine position에 비해 10mmHg이상 증가한 경우를 양성 혈류역학적반응으로 각각 정의하였다. 결과 : 1. 양성 호흡반응 대상 ARDS 환자 중 65%(15/23)가 양성 호흡반응을 보였고 양성 반응자는 비반응자에 비해 연령, 남녀비, ARDS 유발 원인, supine position에서의 $PaO_2/FIO_2$비, Cst, rs 등은 차이가 없었으나 평균동맥압이 더 높고($91.1{\pm}13.1mmHg$ vs. $76.0{\pm}18.7mmHg$, p=0.035), 생존율이 높은 경향을 보였다(9/15 vs. 2/8, p=0.074). 양성 호흡반응자의 supine, prone 0.5 및 2시간의 $PaO_2$는 각각 $69.8{\pm}17.6mmHg$, $83.2{\pm}22.6mmHg$, $96.8{\pm}22.7mmHg$(p<0.001), $PaO_2/FIO_2$비는 각각 $108.1{\pm}40.5mmHg$, $137.3{\pm}60.0mmHg$, $157.7{\pm}50.0mmHg$로 증가하였다(p=0.001). 2. 양성 혈류역학적반응 Prone position시 평균 동맥압이 10mmHg이상 증가한 경우는 22%(5/23)이었고 이 중 2명은 양성 호흡반응이 없는 환자였다. 양성 혈류역학적반응을 보인 환자와 보이지 않은 환자 사이에 기저 평균동맥압($77.1{\pm}11.1mmHg$, $89.8{\pm}16.6mmHg$, p=0.099)이나 supine position 에서의 PEEP 사용 수준 ($7.8{\pm}3.2cm$ $H_2O$, $8.6{\pm}3.5cm$ $H_2O$, p=0.188) 등은 유의한 차이가 없었다. 결 론 : ARDS 환자에서 prone position은 폐산소화지표를 호전시키거나 평균동맥압을 상승시키며 양성 호흡반응 여부는 ARDS 발생 후 조기에 결정되는 것으로 추정되었다.

  • PDF

오니 시료중의 무기 Priority Pollutants의 분석 과정에 미치는 매질의 영향 (Matrix effect on the Determination of Inorganic Priority Pollutants in Sludges)

  • 이혁희;이석근
    • 분석과학
    • /
    • 제11권4호
    • /
    • pp.297-304
    • /
    • 1998
  • 무기 priority pollutants의 분석에 미치는 매질의 영향을 살펴보기 위하여 도금, 피혁, 제지, 전기, 염색 sludge에 7종의 무기 priority pollutants(Ni, Cr, Cu, Zn, Pb, Cd, Hg)를 첨가하고 EPA 3050방법, 환경처의 폐기물공정시험방법 및 폐기물공정시험방법을 수정한 본 연구실 방법으로 비교 연구하였다. EPA 3050법에 따라 추출한 경우 Hg를 제외하고 평균회수율은 95.5%, 폐기물공정시험방법의 용출시험 방법에 따라 추출한 경우는 11.1%, 그리고 본 연구실에서 폐기물공정시험방법을 수정한 추출법의 경우는 27.7%의 평균 회수율이 나타났다. 매질에 따른 digestion에 대한 영향을 살펴보기 위하여 추출법에 의해 추출된 용액을 MDS(microwave digestion system)와 $HNO_3+HClO_4$ digestion 방법으로 회수율을 비교하였다. 유기 및 무기 매질에 대한 영향을 살펴보기 위하여 유기 매질인 경우는 triethanol amine, 무기 매질인 경우는 $FeCl_3{\cdot}6H_2O$$AlCl_3{\cdot}6H_2O$를 첨가하여 분석용 시료를 조제하고 AAS 및 HG-AAS로 회수율을 구하였다. 유기 및 무기 매질을 첨가한 시료가 첨가 하지 않은 시료 보다 회수율이 낮게 나타남에 따라 매질에 의한 영향을 받는 것으로 조사되었다. Hg는 MDS로 digestion하는 것이 회수율이 높게 나타났으며, Hg를 제외한 다른 원소는 $HNO_3+HClO_4$로 digestion 하는 것이 회수율 증가를 나타냈다.

  • PDF

고온 초전도 Hg$Ba_{2}$Cu$O_{4+7}$물질에 Ag의 첨가에 따른 초전도특성 연구 (The influence of Ag-additions on the superconducting properties of Hg$Ba_{2}$Cu$O_{4+7}$ materials)

  • 송규정;하홍수;하동우;오상수;권영길;류강식
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.21-24
    • /
    • 2001
  • A series of superconducting Hg$Ba_{2}$Cu$O_{4+7}$ materials, containing $Ag_{x}$ additions with molar fraction x = 0, 0.05, 0.1, 0.3, and 0.5, have been studied. This study has showed that Ag additions lead to changes in superconducting properties of Hg-1201 materials. In addition, according to the amount of $Ag_{x}$ additions with molar fraction x up to 0.5, both $T_{c}$ and $J_{c}$ of Hg-1201 materials generally decrease with Ag-content. These and other results are discussed in this paper.

  • PDF