재사용(再使用) 투석기(透析器)의 효과(效果) ${\cdot}$ 안정성(安定性) 및 비용절감(費用節減)에 관한 연구(硏究) (A Study of the Effect, Safety and Saving Expense by Reusing Hemodialyzer)

  • 정하정
    • 간호행정학회지
    • /
    • 제3권1호
    • /
    • pp.93-106
    • /
    • 1997
  • By the increase of the rate of existence of the hemodialyzing patients, they were required the long run treatment. Regardless of medical insurance expansion, hemodialyzing cost much expenses so that hospital has been considering the reuse of hemodialyzer and flowing euqipments along with the diverse study and progress of the ways of hemodialyzing and medical instruments. This study was aimed to provide the basic materials regarding the reuse of hemodialyzer which is used for the patients of chronic renal disease. The reusing program in the artificial kidney center of K hospital has been used for this study from 50 patients aften one year result from Sep. 1995 through Aug. 1996. Automatic equipment of DRS-4 made by Seratronic Co., was used as the equipment and it was retreated with the function test simultaneously. Compliaction and confirmation of the infection were by the records of the hemodialysis of the patients. SPSS was used for the analysis of the materials by computerization. The character of the patients and the rate of removal was by mistake and percentage, function test and rate of complication by Ftest(ANOVA) and the rate of complication per items by ${\chi}^2$ and Ftest. As the post test the Duncan's test was used for the statistically significant different variables in the standard of p<.05 after Ftest. The followings are the summary of the result : 1) In the function test of the new hemodialyzer and the reused one, and in all of CA110 and CF15.11, the dialyzer ultrafiltration coeffient(KUf) was appeared to have been higher in the reusing groups than the first use ones. This has been the normal limit showing no troubles with them. 2) In the function test of the new and reused hemodialyzer, in all of CA110 and CF15.11, the total blood volume was appeared to have been the less value in the reuse groups than the new ones. This was the price within 80% of the first price that both showed possible for use. 3) The result of reuse hemodialyzer of CA110 was $29.48{\pm}7.83$ in average in the test of leak test while $17.3{\pm}7.96$ in reuse of CF15.11. The normal limit of <60 was the leak test result. So both of the hemodialyzer was normal for reuse. 4) The rate of removal of Blood Urea Nitrogen(BUN) was 72.25% in CA110 hemodialyzer by reusing 16-20 times as the highest rate showing the better result in the reuse hemodialyzer, while in CF15.11 hemodialyzer showed 71.16% by highest rate in the first use by the highest rate with no difference from the reuse. 5) The rate of removal of serum creatinine of CA110 was 64.08% by highest rate in reuse of 1-5 times by showing better result in reuse hemodialyzer. While in CF15.11 66.47% the highest by reuse of 16-20 times showing no difference from each other. 6) No patients were admitted or precribed by antibiotics in relation with reuse dialyzer and no reports were shown about hepatitis $B{\cdot}C$. AIDS in fection. 7) Of the total 248 episods of complication due to the hemodialyzing, 86 by first use, 73 by 1-5 times, 35 by 6-10 times, 35 by 11-15 times and 19 by 16-20 times have been shown which have had no significant difference between the groups. 8) In the comparison of the expense for the hemodialyzer, there was the effect of saving 11,597.6 Won between the first and reuse hemodialyzer. And by decreasing the extracted materials, they did the great role of disposing the waste matters.

  • PDF

실험적으로 신부전을 유발시킨 개에서 박동형 혈액투석기의 효능 (Efficacy of Pulsatile Hemodialyzer to Experimental Renal Failure in Dog)

  • 지혜정;윤영민;이주명;강태영;김재훈;정종태;최민주;민병구;이경갑
    • 한국임상수의학회지
    • /
    • 제23권3호
    • /
    • pp.320-324
    • /
    • 2006
  • The purpose of the present study was to compare pulsatile type(Twin Pulse Life Support; TPLS) with rotary type hemodialyzer(AK95) in order to reduce the dialysis time and to improve dialysis effect. Three healthy dogs(about 30 kg BW) were used. Experimental renal failure was induced by the ligation of bilateral renal artery. A pair of catheters were implanted in jugular vein for dialysis. Daily investigated parameters included clinical signs such as vomiting, fecal appearance and activity, and also laboratory data such as PCV, TP, BUN and creatinine. Hemodialysis was started above 90 mg/100 ml BUN level and, laboratory data were measured every an hour for 4 hours. Heparin was administered 300 IU/Kg before dialysis and 150 IU/Kg via IV route every 90 minutes during dialysis. Clinical signs after induction renal failure were shown severe vomiting, anorexia, diarrhea, mucous feces, ataxia, dilated pupil and episcleral hyperemia. The average of BUN value decreased hourly $99{\pm}12.1,\;84{\pm}12.2,\;72{\pm}8.0,\;58{\pm}7.1,\;48{\pm}5.2,\;and\;39{\pm}3.2mg/100ml$ by hemodialysis. The average of creatinine value decreased $7.8{\pm}0.61,\;6.4{\pm}0.40,\;5.3{\pm}0.42,\;4.5{\pm}0.23,\;4.0{\pm}0.41,\;and\;3.4{\pm}0.42mg/100ml$ according to hemodialysis an hour. There are not significantly differences BUN, creatinine, PCV and TP values between pulsatile and rotary type hemodialysis. These results suggested that effects of hemodialysis with Pulsatile type(TPLS) are not significantly difference as compared with hemodialysis of rotary type(AK95). Further research is needed in order to estimate the influence of cardiovascular and pulmonary system in hemodialysis of pulsatile type.

인공신에 의한 백혈구 수의 변화 혈장 및 알부민의 전처치가 이에 미치는 영향 (The Effect of Cuprophane Hemodialyzer Treated with Plasma and Albumin on Leukocyte Count)

  • 장현규;박찬현
    • 대한의용생체공학회:의공학회지
    • /
    • 제8권2호
    • /
    • pp.241-244
    • /
    • 1987
  • It is now well established that transient granulocytopenia is common in patients during the initial phase of hemodialysis with new cuprophane membrane, but not with reused nembrane, or some synthetic membranes. In this study, new cuprophane dialyzer was treated with plasma and albumin, respectively, then, peripheral blood leukocytes were counted at the onset and after 15 minute of hemodialysis. In the plasma-treated group, the percent of leukopenia was less (41.3 %) than control group (71.3 %). In the plasmatreated group, the degree of leukopenia was close to that ot'control grou p. The protective factor, therefore is thought to be present in the plasma other than albumin fraction.

  • PDF

Diffusion-Enhanced Modified Hemodialyzer

  • Lee, Kyung-Soo;Lee, Sa-Ram;Mun, Cho-Hae;Min, Byoung-Goo
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권4호
    • /
    • pp.455-460
    • /
    • 2007
  • Flow mismatch between blood and dialysate is invariably encountered during conventional hemodialysis, and this deteriorates diffusive mass transfer. A modification of a conventional dialyzer was conceived to prevent this mismatch. The modified dialyzer includes two independent blood flow regions (central and peripheral regions), which were achieved by redesigning the dialyzer cap. Resultantly, the blood stream was divided into two concentric dialyzer regions. Solutes clearances obtained using the modified dialyzers were compared with those of conventional dialyzers. Solutes clearances by conventional dialyzers were uniform, but solutes clearances by modified dialyzers were found to be dependent on the simulated blood split into dialyzer central and peripheral regions. Maximal clearances using the modified dialyzer were improved by up to approximately 7.6% for urea and 7.3% for creatinine, as compared with those of conventional dialyzers. More optimizations are required for clinical applications, but the finding that blood flowrates through central and peripheral fiber bundles can be easily regulated is encouraging.

말기신부전 환자의 혈액투석 치료가 안면 색에 미치는 영향 (The Influence of Hemosialysis to the Face Color of Patients in End Stage Renal Disease)

  • 이세환;조동욱
    • 정보처리학회논문지B
    • /
    • 제17B권6호
    • /
    • pp.437-444
    • /
    • 2010
  • 본 논문에서는 한의학의 진단법인 사진법 중 망진(望診)이론을 기반으로 인체 오장 중 가장 중요한 장기의 하나인 신장의 질환 진단을 위해 영상처리기법을 적용하여 색과 신장 질환과의 상관성을 분석하는 방법을 제안하고자 한다. 이를 위해 안면 영상을 처리하고 분석하여 신장 질환에 따른 얼굴색의 색차를 시각화, 객관화하기 위한 방법을 제시하고자 한다. 특히 본 논문은 신장질환자 중 만성신부전으로 인해 혈액 투석 치료 중인 신장 기능 이상자 들을 대상으로 피 실험자 집단군을 구성하고 안면 영상 및 임상 자료를 수집하여 한의학적 망진 이론에서 신장과 관련된 얼굴 부위가 지각 이며 신장에 이상이 생길 경우 이 부위를 통해 흑색이 발현한다는 이론을 가설로 제시하고 안면 영상 중 지각 부위를 추출하는 알고리즘과 이 부위의 흑색의 변화를 측정 하는 방법에 대해 제안하고자 한다. 끝으로 임상 실험 및 자료 분석을 통해 제안한 방법의 유용성을 입증하고자 한다.