태양열집속집열기의 설계 방법에 관한 연구 (A New Approach to Design Method of the Solar Compound Parabolic Concentrator with Tubular Absorber)

  • 김석종;임상훈
    • KIEAE Journal
    • /
    • 제2권3호
    • /
    • pp.33-38
    • /
    • 2002
  • The intermediate range of temperatures($100{\sim}300^{\circ}C$) which can be achieved with CPCs(Compound Parabolic Concentrators) without tracking device provides both economic and thermal advantages for solar collector design. The present paper summarizes critical design considerations for CPC with cylindrical absorber and its optical performance using ray tracing program. Concentration ratios vary as acceptance half angle, ratio of reflector height to aperture width and ratio of reflector area to aperture area. This effects showed that the concentration ratio was increased as acceptance angle but optimum ratio of reflector height to aperture width existed at critical value. As a result of ray tracing, solar ray losses was maximized at acceptance half angle and this problem was solved by increasing absorber tube diameter. The concentrating flux distribution on the absorber surface was uniform but peak flux existed.

신경회로망기법을 사용한 엇갈린 딤플 유로의 최적설계 (Design Optimization of a Staggered Dimpled Channel Using Neural Network Techniques)

  • 신동윤;김광용
    • 한국유체기계학회 논문집
    • /
    • 제10권3호
    • /
    • pp.39-46
    • /
    • 2007
  • This study presents a numerical procedure to optimize the shape of staggered dimple surface to enhance turbulent heat transfer in a rectangular channel. The RBNN method is used as an optimization technique with Reynolds-averaged Navier-Stokes analysis of fluid flow and heat transfer with shear stress transport (SST) turbulence model. The dimple depth-to-dimple print diameter (d/D), channel height-to-dimple print diameter ratio (H/D), and dimple print diameter-to-pitch ratio (D/S) are chosen as design variables. The objective function is defined as a linear combination of heat transfer related term and friction loss related term with a weighting factor. Latin Hypercube Sampling (LHS) is used to determine the training points as a mean of the design of experiment. The optimum shape shows remarkable performance in comparison with a reference shape.

거칠기 형상이 마찰 계수와 열전달에 미치는 영향 (Effects of Rib Geometries on the Friction Factors and Heat Transfer in the Channel)

  • 안수환;손강필
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.241-247
    • /
    • 2001
  • A comparison of fully developed heat transfer and friction factor characteristics has been made in rectangular ducts with ones roughened by five different shapes. The effects of rib shape geometries and Reynolds number are examined. The rib height-to-duct hydraulic diameter, pitch-to-height ratio, and aspect ratio of channel width to height are fixed at e/De=0.0476, P/e=8, and W/H=2.33, respectively. To understand the mechanisms of the heat transfer enhancements, the measurements of the friction factors are also conducted in the smooth and rough channels. The data indicates that the triangular type rib has a substantially higher heat transfer performance than any other ones in the range we studied.

  • PDF

채널유동에서 거친벽면이 열전달에 미치는 효과 (Effects of Rough Surfaces on Heat Transfer in Channel Flow)

  • 안수환
    • 동력기계공학회지
    • /
    • 제5권2호
    • /
    • pp.30-35
    • /
    • 2001
  • A comparison of fully developed heat transfer and friction factor characteristics has been made in rectangular ducts with one wall roughened by five different shapes. The effects of rib shape geometries and Reynolds number are examined. The rib height-to-duct hydraulic diameter, pitch-to-height ratio, and aspect ratio of channel width to height are fixed at $e/D_e=0.0476$, P/e=8, and W/H=2.33, respectively. To understand the mechanisms of the heat transfer enhancements, the measurements of the friction factors are also conducted in the smooth and rough channels. The data indicate that the triangular type rib has a substantially higher efficiency index than any other ones in the range we studied.

  • PDF

An Investigation on Friction Factors and Heat Transfer Coefficients in a Rectangular Duct with Surface Roughness

  • Ahn, Soo-Whan;Son, Kang-Pil
    • Journal of Mechanical Science and Technology
    • /
    • 제16권4호
    • /
    • pp.549-556
    • /
    • 2002
  • An investigation on the fully developed heat transfer and friction factor characteristics has been made in rectangular ducts with one-side roughened by five different shapes. The effects of rib shape geometries as well as Reynolds numbers are examined. The rib height-to-duct hydraulic diameter, pitch-to-height ratio, and aspect ratio of channel width to height are fixed at e/De=0.0476, P/e=8, and W/H=2.33, respectively. To understand the characteristics of heat transfer enhancements, the friction factors are also measured. The data indicates that the triangular type rib has a substantially higher heat transfer performance than any other ones.

사각 덕트에서 거칠기 형상이 마찰계수와 열전달에 미치는 효과 (Effects of Rib Shapes on the Friction Factors and Heat Transfer in a Rectangular Duct)

  • 안수환;손강필
    • 설비공학논문집
    • /
    • 제13권5호
    • /
    • pp.341-347
    • /
    • 2001
  • A comparison of fully developed heat transfer and friction factor characteristics has been made in rectangular ducts with ones roughened by five different shapes. The effects of rib shape geometries and Reynolds number are examined. The rib height-to-duct hydraulic diameter, pitch-to height ratio, and aspect ratio of channel width to height are fixed at $e$/De=0.0476, P/$e$=8, and W/H=2.33, respectively. To understand the mechanisms of the heat transfer enhancements, the measurements of the friction factors are also conducted in the smooth and rough channels. The data indicates that the triangular type rib has a substantially higher heat transfer performance than any other ones in the range we studied.

  • PDF

확산형 흡수식 냉동기용 기포펌프의 운전특성에 관한 연구 (Operating Characteristics of a Bubble Pump for Diffusion-Absorption Refrigerator)

  • 이현경;김선창;이재헌
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.878-887
    • /
    • 2001
  • Experimental investigation has been carried out to examine the operating characteristics of a bubble pump for diffusion absorption refrigerator. The effects of heat input and delivery height on generation rate of refrigerant vapor and circulation rate of solution have been investigated. as a result heat input and delivery height increase, circulation rate of solution increases. And the smaller the tube diameter, the larger the circulation rate of solution. Pumping ratio increases to a critical point and then decrease with the increase of heat input, and it increases with the increase in delivery height. In this paper, Marcus's analytical theory was also examined. It was found that the Marcus\`s analytical theory of a bubble pump was not appropriate for a bubble pump using ammonia aqueous solution as a working fluid.

  • PDF

콘크리트 코어 압축강도의 각종 영향인자 보정 (Correction of Various Testing Factors Affecting Measured Compressive Strength of Concrete Core)

  • 박석균;최욱;오광진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.973-978
    • /
    • 2002
  • This study was performed to verify the effect of various testing conditions affecting measured compressive strength of concrete core and to compute the correction coefficients for it. Conditions of specimens affecting test results include size(diameter), height-diameter ratio, humidity of specimen, amount and arrangement of bar, core direction from structure and method of end preparation. In testing core strength of concrete, special cares should be taken on various testing conditions whose effects have been latent in conventional concrete.

  • PDF

Effect of cylinder diameter and boat tail angle on the free vibration characteristics of a typical payload fairing

  • Ramamurti, V.;Rajarajan, S.;Rao, G. Venkateswara
    • Structural Engineering and Mechanics
    • /
    • 제13권3호
    • /
    • pp.345-353
    • /
    • 2002
  • Three noded plate and shell finite element and 3D beam element in conjunction with Lanczos method are used for studying the effect of boat tail angle on the free vibration characteristics of a typical payload fairing for three different cylinder diameters with height to diameter ratio 1.5. Configurations without boat tail structural member are also studied. One half of the one side fairing structure is considered for the analysis and symmetric boundary conditions are used.

진공 예압형 공기베어링의 특성 해석 (Analysis on characteristics of vacuum preloaded air bearing)

  • 김경호;박천홍;이후상;김승우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.355-358
    • /
    • 2003
  • This paper presents characteristics of vacuum preloaded porous air bearing. Pressure distribution of a porous pad and vacuum pocket are calculated. And load capacity and stiffness of the bearing are analyzed with various vacuum parameters, that is. clearance height. tube diameter, tube length. pumping speed of vacuum pump, vacuum pocket to porous pad area ratio. From the simulation results, optimum clearance for best performance can be selected adjusting these parameters, especially tube diameter which is the most dominant source.

  • PDF