• 제목/요약/키워드: Heavy-Weight Impact Sound

검색결과 113건 처리시간 0.025초

슬래브 상부 몰탈층에 사용된 작은시편의 유효성 검토(중량충격음을 중심으로) (Small-size Specimen's Effectiveness That is Used to Mortar Layer of Slab (Heavy-weight Floor Impact Sound))

  • 정진연
    • 한국소음진동공학회논문집
    • /
    • 제19권2호
    • /
    • pp.184-191
    • /
    • 2009
  • This study examined small-size specimen's effectiveness that is used to evaluate floor impact sound performance. Floor impact sound level of small-size specimen is higher than full-size. This is due to excessive impact power of Bang machine. Impact hammer that has small impact power relatively can solve this problem. But, according to the size of specimen, mode shape and frequency that influence to structural borne sound is changed. Slab mode of full-size specimen was changed to frequency design of resilient materials. But in case of small-size specimen, there is no change of vibration mode by resilient materials change, Vibration mode of small-size specimen is the same. Therefore, it is not proper that use small-size specimen in floor impact sound estimation.

바닥충격에 의한 공동주택의 바닥, 벽, 천장의 진동 및 소음방사특성 연구 (Evaluating the Vibrational Characteristics of Floor Impact Noise in Different Structural Elements of an Apartment House)

  • 이병권;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.480-485
    • /
    • 2002
  • The overall noise reduction was compared in regard to the vibrational characteristics of floor impact noise in a multi story residential building which has several noise reduction treatments. The vibration through its structural elements such as wall, floor and ceiling and sound emitting were investigated for each insulation treatment. It was found that, in case of heavy-weight impact noise, the vibration energy is emitted mostly from ceiling, but for the light-weight impact noise, most of the energy comes through ceiling and walls. That is, the vibration of a ceiling is the main factor that determines the frequency characteristics of the transmitting noise to lower floors.

  • PDF

EVA 완충재의 형상변환을 통한 복합구조의 바닥충격음 변이 조사 (Investigation of the level difference of floor impact noises through the shape variation of EVA resilient materials with composite floor structure)

  • 이야긴;이승민;한찬훈
    • 한국음향학회지
    • /
    • 제43권1호
    • /
    • pp.60-71
    • /
    • 2024
  • 본 연구는 일반적인 평평한 에틸렌 비닐 아세테이트(Ethylen Vinyl Acetate, EVA) 완충재의 형상을 변화시켜 다양한 차음소재와 조합하여 복합구조의 바닥충격음 변화를 조사하는 데에 목적이 있다. 바닥충격음 저감에 효과적인 완충재를 선정하기 위해 Flat, Deck, Cavity type의 EVA, EPS, PET 흡음재, PP판넬, 고무발판 등 다양한 완충재를 조합하여 뱅머신을 이용한 1차 실험을 진행하였다. 1차 실험 데이터에 대해 통계분석한 결과 완충재 두께가 40 mm에 가까울수록 바닥충격음 저감효과가 증가하였으며 PET 흡음재, PP시트, 고무발판 등을 조합한 복합완충재에서 바닥충격음 효과가 증가하는 것을 알 수 있었다. 이에따라 2차 실험에서 모든 복합완충재의 두께는 40 mm로 통일하였으며, 1차 실험에 사용된 Flat, Deck, Cavity type 및 EVA를 발판형태로 가공한 Mount type 등 4가지 형태의 복합완충재를 설계하였다. 또한, Mount type을 제외한 3가지 기본 형태에서 각각 PET 흡음재(7 mm)를 추가했을 시 바닥충격음 변화를 살펴보았으며, Mount type의 경우 EVA발판 개수에 따른 바닥충격음 변화에 대해 고무공 충격원을 이용한 2차 실험을 진행하였다. 모든 실험은 공인인증시험기관의 목업실험실에서 진행하였다. 실험 결과, 기본형태의 Flat, Deck, Cavity type에서 PET를 추가할 경우 통계적으로 경량 5 dB ~ 9 dB, 중량 1 dB ~ 5 dB의 저감효과가 나타난 것을 알 수 있었다. 특히, Mount type의 경우 발판 수가 36개 이상일 때 경량 및 중량충격음에서 우수한 것으로 나타났다. 또한, 4가지 기본형태에 따라 동탄성계수가 높아질수록 바닥충격음의 저감이 증가하는 것으로 나타났다.

측정 불확도에 따른 중량충격음 측정편차에 관한 연구 (Measurement uncertainty in heavy-weight floor impact sounds)

  • 유승엽;김용희;심명희;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.826-829
    • /
    • 2008
  • In a field measurement, measurement errors are produced by measuring environments and systematic errors in the measurement procedure. Measurement errors can be expressed as a measurement uncertainty. In this study, the measurement uncertainty and various measuring factors are investigated in heavy-weight impact sounds. According to KS 2810-2, the model functions, which is the estimation of the maximum SPL measurement in each octave band frequency, are determined. From this estimation model, 3.53dB is shown in 63Hz. This level is caused by the sound field of the receiving room, which does not meet the diffusing field.

  • PDF

공동주택 음원실 바닥의 하중 설치에 따른 중량충격음 특성에 관한 연구 (The Research of the Heavy-Weight Impact Sound Characteristic by Live load Installation on the Source Room)

  • 김경우;양관섭;손장열
    • 한국음향학회지
    • /
    • 제26권6호
    • /
    • pp.235-242
    • /
    • 2007
  • 공동주택의 바닥충격음 측정 및 평가는 주로 입주 전에 이루어지고 있으나 실제 충격음 발생은 입주 후 커튼과 가구와 같은 중량물이 설치되어 있는 조건이므로 입주 전 후 음원세대(음원실)와 수음세대(수음실)의 상황은 다르다고 할 수 있다. 본 연구에서는 음원실에 가구 등과 같은 하중 설치에 따른 중량충격음 변화정도를 파악하기 위하여 바닥충격음 시험동과 현장에서 활하중($200kg/m^2$) 설치 전 후의 음원실 바닥슬래브 하부 진동가속도레벨 및 수음실 충격음레벨 변화를 측정하였다. 측정결과 하중설치를 통하여 진동가속도레벨 및 충격음레벨이 다소 저감되었으나 큰 영향은 받지 않는 것으로 나타났으며, 슬래브의 공진주파수도 변화하지 않았다.

콘크리트 슬래브와 바닥 상부구조가 일체된 바닥구조의 바닥충격음 (Floor Impact Noise Level for Concrete Slab Integrated with Floor Finishing Layers)

  • 문대호;오양기;정갑철;박홍근
    • 한국소음진동공학회논문집
    • /
    • 제26권2호
    • /
    • pp.130-140
    • /
    • 2016
  • Floating floor is most commonly used at apartment houses in Korea for thermal insulation and reducing impact noise. But it in proven that the floating floor is not effective for reducing the floor impact noise in low frequency range. In most cases, impact sound pressure level under 63 Hz frequency band were actually increased by the resonance of resilient material, lightweight concrete and the finishing mortar installed on it. In this paper, an integrated floor system consist of 70 mm light weight concrete and 40 mm finishing mortar successively installed on the concrete slab was suggested to avoid the resonance. Integrated floor system increases total flexural stiffness and mass per unit area. The natural frequencies of first and second vibration mode were increased and acceleration response and floor impact sound level was decreased in all measurement range.

감성평가 기반 바닥충격음 등급화 및 수인한도 설정 (Floor impact sound classification and setting Acceptable limit based on psychoacoustical evaluation)

  • 김성민;홍주영;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.7-9
    • /
    • 2014
  • An auditory experiment was conducted to establish annoyance criteria for floor impact noise in apartment buildings. Heavyweight floor impact sounds were recorded using an impact ball; the impact sound pressure level (SPL) together with the temporal decay rate (DR), which is quantified by the dB drop per second, was analyzed. For the experiment, A-weighted exposure levels of the heavy-weight floor impact sounds ranging 34~73 dB were evaluated at 3 dB intervals. Participants used a 7-point verbal scale to evaluate the level of annoyance from floor impact noise. The results show that the annoyance increases with increasing impact SPL and decreasing DR. Consequently, a classification and an acceptable level of floor impact sounds were proposed.

  • PDF

바닥충격음 완충재의 동적특성과 소음저감 성능 비교 (Comparison Between the Dynamic Properties and Noise Isolation Performances for a Floor Impact Isolation Pad)

  • 양수영;이동훈;홍병국;송화영;이주원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.275-278
    • /
    • 2005
  • In this study, the dynamic properties of a floor impact sound isolation pad expressed in terms of the natural frequency, the dynamic stiffness per unit area and the loss factor are measured by the resonant method. By using the measured dynamic properties, the vibration transmissibility diagram is obtained for each isolation pad, which is compared with the values tested by the impact sound sources at the room in an apartment. From the comparative results, it is found that the noise reduction Performances. of isolation pads are closely connected with the natural frequency and the dynamic stiffness per unit area.

  • PDF

유한 요소법을 이용한 나 슬래브의 2차원 바닥 충격진동 해석 (2-Dimensional Floor Impact Vibration Analysis in Bare Reinforced Concrete Slab Using Finite Element Method)

  • 서상호;전진용
    • 한국소음진동공학회논문집
    • /
    • 제15권5호
    • /
    • pp.604-611
    • /
    • 2005
  • The relationship between floor impact sound and vibration has been studied by field measurements, and the vibration modal characteristics have been analyzed. Vibration levels impacted by a standard heavy-weight impact source have been predicted according to the main design parameters using finite element method. Experimental results show that the dominant frequencies of the heavy impact sounds range below 100 Hz and that they are coincident with natural frequencies of the concrete slab. In addition, simple 2-dimensional finite element models are proposed to substitute 2 types of 3-dimensional models of complicated floor structural slabs those by The analytical result shows that the natural frequencies from first to fifth mode well correspond to those by experiments with an error of less than $12\%$, and acceleration peak value iscoincident with an error of less than $2\%$. Using the finite element model. vibration levels areestimated according to the design Parameters, slab thickness, compressive strength, and as a result, the thickness is revealed as effective to increase natural frequencies by $20\~30\%$ and to reduce the vibration level by 3$\~$4 dB per 30 mm of extra thickness.