• Title/Summary/Keyword: Heavy floor impact sound

Search Result 123, Processing Time 0.023 seconds

Study on the Design of Butyl Rubber Compound and Noise Reduction System for Sound Insulation (소음 차단 성능 향상을 위한 부틸 탄성체 배합 및 진동제어 시스템 디자인 연구)

  • Kim, Won-Taek;Chung, Kyung-Ho
    • Elastomers and Composites
    • /
    • v.49 no.2
    • /
    • pp.95-102
    • /
    • 2014
  • The noise between floors of apartment has been hot issue nowadays. In order to improve the noise insulation performance, we proposed the antivibration rubber system which can be applied to the floor system for sound insulation. Among various types of elastomer, butyl rubber showed the good aging characteristic, low rebound resilience and high damping factor. Thus, the butyl rubber was selected as a basic rubber for antivibration rubber system. The effects of type and loading amounts of carbon black on antivibration properties of butyl rubber were studied. The increase of surface area and the content of carbon black resulted in high bound rubber fraction, high mechanical property, low rebound resilience, and high damping factor of butyl rubber. Based on the results of this study, the new antivibration rubber was prepared and applied to the floor system for sound insulation. The impact sounds of floor system proposed in this study were 40 dB and 43 dB in cases of light weight and heavy weight impact sound, respectively.

Evaluation of floor impact sound and airborne sound insulation performance of cross laminated timber slabs and their toppings (구조용 직교 집성판 슬래브와 상부 토핑 조건에 따른 바닥충격음 및 공기전달음 평가)

  • Hyo-Jin Lee;Yeon-Su Ha;Sang-Joon Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.572-583
    • /
    • 2023
  • Demand for wood in construction is increasing worldwide. In Korea, technical reviews of high-rise Cross Laminated Timber (CLT) buildings are under way. In this paper, Floor Impact Sound Insulation Performance (FISIP) and Transmission Loss (TL) of 150 mm thick CLT floor panels made of two domestic species, Larix kaempferi and Pinus densiflora, are investigated. The CLT slabs were tested in reverberation chambers connected vertically. When comparing Single Number Quantity (SNQ) of FISIP of the bare panels, the Larix CLT is 3 dB lower in heavy-weight and 1 dB in light-weight than the Pinus CLT. However, there was no difference when concrete toppings were added to improve the performance. As the concrete toppings became thicker, the heavy-weight was reduced by 9 dB ~ 20 dB, and the light-weight by 20 dB ~ 30 dB. And the analysis of these results with area density has confirmed that the area densities are highly correlated (R2 = 0.94 ~ 0.99) to the FISIP of the CLT. The types of CLT didn't affect the TL. Comparison of theoretical TL values with measured TL values has shown that the frequency characteristics are similar but 8 dB ~ 12 dB lower in measured values. The relationship between the TL and frequency characteristics of the tested CLT slabs was derived by using the correction value.

A Study on the Acoustic Performance Indication Standards of Apartment Housing Performance Grade Indication System (공동주택 성능등급 표시제도 상의 음성능 표시기준 고찰)

  • Yang, Kwan-Seop;Kim, Kyoung-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1252-1255
    • /
    • 2006
  • The government has enforced Housing Performance Grade Indication System (Article 21, Paragraph 2 of Housing Act) starting January 2006 for the purpose of giving users in hope of toying an apartment opportunities to select housing based on personal preferences by providing information on housing performance at the time of tenant recruitment announcement as well as securing desirable environment (comfort) by encouraging construction companies to build housing of the indicated performance level. The acoustic performance indication items include three items such as floor impact isolation performance(light weight impact sound, heavy weight impact sound), bathroom noise and insulation performance of boundary walls between households. This paper explains the background, the basis of creation and evaluation method focused on the acoustic environment performance helping for the developer of technique and a staff in charge of construction business who cope with this system.

  • PDF

Comparison of Impact Sound Insulation Performances of Apartment Floors Against Heavy-weight Impact Sources via Field Measurement Data (공동주택 현장 측정자료를 활용한 중량충격원의 바닥충격음 차단성능 비교)

  • Yun, Chang-Yeon;Yeon, Jun-Oh;Kim, Myung-Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.8
    • /
    • pp.651-658
    • /
    • 2014
  • Notification 2013-611 of MOLIT has come into effect. It relates primarily to new standard impact source. In this study, an in-depth experimental analysis of the difference between a bang machine and an impact ball was performed via field testing of shear wall and flat plate structure at 51 sites. This paper focuses on the difference in single number quantities between a bang machine and an impact ball. At wall thicknesses of 180 and 210 mm in shear wall structure, the single number quantities exhibited differences of 3.1 and 4.5 dB, respectively, and at thicknesses exceeding 250 mm in flat plate structure, the difference was constant at 4.6 dB. With regard to flat plate structures, the single-index difference increased up to 11 dB as the thickness of the floor slab increased. In general, the highest level of contribution for the bang machine was 63 Hz, irrespective of thickness determining bandwidth. The highest level for the impact ball were 63 Hz and 125 Hz. In future research, when reviewing additional field performance measurement data, it will be necessary to consider a detailed examination instead of the current method of uniformly adding 3 dB for all thicknesses and types of structures.

Deviation of Heavy-Weight Floor Impact Sound Levels According to Measurement Positions (마이크로폰의 위치에 따른 중량 바닥충격음레벨의 편차)

  • Oh Yang-Ki;Joo Moon-Ki;Park Jong-Young;Kim Ha-Geun;Yang Kwan-Seop
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.2
    • /
    • pp.49-55
    • /
    • 2006
  • Measurement of impact sound insulation of floor, by current Korean Standard KS F 2810-2. is to be made with peak levels over 4 point in a receiving room. But it is often the case that there is inconsistency in results at various receiving points in the receiving room. Such variations obviously have effects on the repeatability and reproducibility of measured data. The result shows that there are even 10 dB deviations in 63Hz octave band frequency range and relatively less variations are occurred in other low frequency ranges. Such variations seems to be coming from modal overlaps of the receiving room. According to current rating method of floor impact sound. KS F 2863-2, that may affect on the single number latins scheme. From the result of tests in this study, there are 2dB to 6dB differences in the sin91e number with the combination of measurement points. This means that the reduction of measurement variations from the microphone positions is needed for a better credibility of measurement results.

Case study on frequency bands contributing the single number quantity for heavy-weight impact sound based on assessment method changes (중량충격음 평가방법 변화에 따른 단일수치평가량 기여 주파수 대역 사례 분석)

  • Hye-kyung Shin;Sang Hee Park;Kyoung-woo Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.565-571
    • /
    • 2023
  • With the introduction of the post-verification system, the measurement of floor impact noise performance on-site has become mandatory, and the evaluation method has changed. To track the performance changes since the policy implementation, research is needed on how the characteristics of heavyweight impact sound change according to the varied evaluation method. In this study, we analyzed the contribution rate of the frequency band-specific sound pressure level on the single-number quantity for a multi-family housing unit with the same floor plan and floor structure, comprising 59 households, based on the changed impact sources and evaluation indicators. It is difficult to compare simply because the method of calculating contributions by frequency band according to the single-day evaluation is different, but the average contribution rate of 63 Hz was 80.8 % in the evaluation method before the introduction of the post-confirmation system (Tire measurement and evaluated as L'i,Fmax,AW), and the average contribution rate of 125 Hz was 19.2 %. The current evaluation method (rubber ball measurement and evaluation as L'iA,Fmax) shows that the contribution rate has decreased to 33.1 % on average at 50 Hz ~ 80 Hz, 58.7 % on average at 100 Hz ~ 160 Hz, 6.9 % on average at 200 Hz ~ 315 Hz, and 1.3 % on average at 400 Hz ~ 630 Hz. This result is a case analysis for the target apartment house, and it is necessary to analyze measurement data for more diverse apartment houses.

Analysis on Results evaluated by "Housing Performance Grading System" in Korea (주택성능등급 인정 사례의 부문별 평가 결과 분석)

  • Lee, Sung Ok
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.55-66
    • /
    • 2010
  • The government is enacted "Housing Performance Grading Indication System" from qualitative housing supply policy and performance of housing under the background of looking for new plan to secure good housing stock and housing performance. This system consists of 5 main performance section, 14 performance categories and 20 detailed performance items. 5 main performance parts are sound insulation related grading(Light-weight impact sound insulation, heavy-weight floor impact sound insulation, noise emission in bathroom, airborne sound insulation for wall between units), Long-life housing related grading(flexibility, remodeling & maintenance, durability), environment related grading(landscape, indoor air quality and ventilation, energy performance), Living environment related grading(common resident facilities such as playground and consideration for the socially underprivileged such as the aged), Fire fire prevention grading(fire fire prevention). The purpose of this research is to analyze characteristics and assessment results of 20 detailed performance items on "Housing Performance Grading Indication System" which was enforced 240 cases from Jan 9th, 2006 to Sep 30th, 2010. The analysis of approval condition of detailed performance items will be important comments for understanding the current domestic level and development of technology.

A study on the capability of inverse A weighting through the auditory perception test (청감실험을 통한 역A특성 평가방법의 타당성 검토)

  • 이성찬;전진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.586-591
    • /
    • 2002
  • Recently, the research and discussion to set up the evaluation standard for nor impact noises in multistory residential buildings has been vividly carried out In Korea. Therefore, the correlation between the methods and auditory responses was investigated through this research to investigate the applicability of the L index evaluation method and the reverse A characteristics evaluation method that are listed in JIS A 1419 since Japanese circumstance are similar to Korean after evaluating the duality of Korean multistory residential buildings. As a result, it was found that the correlation between the value resulted from L index evaluation and the value from reverse A characteristics evaluation is high. In addition, it was also revealed that human responses to each Impacter was similar. Consequently, it is considered th:31 the tendency about the two methods would be similar.

  • PDF

A Study on the Measurement Method for Improvement of Reliability for Heavy-Weight Floor Impact Sound Measurement (중량 바닥충격음 측정의 신뢰성 향상을 위한 측정방법 검토)

  • Joo, Moon-Ki;Park, Jong-Young;Yang, Kwan-Seop;Oh, Yang-Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.163-170
    • /
    • 2008
  • Most of receiving rooms for the measurement of floor impact sound have rectangular shapes with couple of meters of dimension, with reflective finishing, no furniture, no curtains. Modal overlaps in those condition are the major reason for the low reproducibility, and as a matter of course, the low credibility. It is the major purpose of this study that searching for a better measurement method which mitigate the effect of modal overlap on measurement. Two ways of methods are tested. One is the way described in ISO standards which enables controlling the room modes of receiving rooms, the other is the way which enables to get more precise spatial averages in receiving rooms with room modes. It is not easy maintaining the reverberation time of low frequency bands in the range between 1s and 2s, though it is proven to be effective controlling the room modes with base traps. Space-time average SPL's through combinations of rotating microphones are easy to measure, and have good consistencies with average SPL of entire receiving room.

Utilization of Charcoal as an Environmentally Friendly Building Materials (II) - A Study on the Energy Saving and Sound Insulation Characteristics of Building Materials Prepared with Charcoal - (목탄을 이용한 친환경 건축자재 이용기술(II) - 목탄 함유 건축자재의 에너지 절감 및 차음 특성에 관한 연구)

  • Ahn, Byoung-Jun;Paik, Ki-Hyon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.39 no.1
    • /
    • pp.41-52
    • /
    • 2011
  • This study was carried out to investigate the effect of energy saving and sound insulation of building materials mixed with charcoal. To investigate the functionality of building based on the difference of construction materials, three different experimental buildings were constructed. They were buildings built with the conventional construction materials (A), the charcoal construction materials (B), and the charcoal-sericite construction materials (C). The study showed that energy consumption could be reduced approximately 9.5% and 14.5% by replacing A with B and C, respectively. Especially, it is revealed that the lower outdoor temperature was, the higher energy saving effect was. Also, after shutoff the boiler switch the decrease rate of room temperature of the one using B was lower than those of others using A and C so that the room temperature at the building using B was higher by $3.5{\sim}4.2^{\circ}C$ in the 1 meter air above the ground and by $4.4{\sim}5.4^{\circ}C$ on the floor surface after 12 hours passed. In the building noise test the heavy-and light-weight impact sound of the plate, represented by criterion of noise between floors in multi-story building, tended to decrease in the test sample containing charcoal.