• Title/Summary/Keyword: Heavy electric apparatus

Search Result 9, Processing Time 0.031 seconds

A study on the performance improving of the dielectric test facilities for UHV heavy electric apparatus (초고압 중전기기 절연시험설비 성능개선 연구)

  • Lee, J.G.;Kim, M.K.;Jeong, J.Y.;Kim, I.S.;Kim, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2100-2102
    • /
    • 2005
  • In this Paper, there have been brief review about the important consideration in laboratory planning and designing the dielectric testing facilities for heavy electric apparatus up to 800kV-class in the high voltage testing fields. To improve and reinforce the existing dielectric test facilities in the way of econo-mical and optimal condition, wide investigation and an analysis for a solution, especially overshoot compensation method. have been suggested. With the brief description about those matters in constructing and improving the test facilities, the specification of each facility has been shown in the paper.

  • PDF

Experimental study on the lightning impulse breakdown characteristics of air for the development of air-insulated high voltage apparatuses (고전압 전력기기 개발을 위한 기중 임펄스절연파괴특성에 관한 연구)

  • Kang, Hyoun-Gku;Kim, Joon-Yeon;Seok, Bok-Yeol;Kim, Dong-Hae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1473_1474
    • /
    • 2009
  • To develop electrically reliable high voltage apparatuses, the experimental study on the electrical breakdown field strength is needed, as well as theoretical approach. In this paper, lightning impulse breakdown characteristics considering utilization factors are investigated for the establishment of insulation design criteria of an high voltage apparatus. The utilization factors are represented as the ratio of mean electric field to maximum electric field. Dielectric experiments are performed by using five kinds of sphere-plane electrode systems made of stainless steel. As a result, it is found that dielectric characteristics are affected by not only gap length but also utilization factor of electrode systems. The results are expected to be applicable to the design of high voltage apparatuses.

  • PDF

Performance Evaluation and Consideration of the UHV IVG (UHV IVG의 성능평가 및 고찰)

  • Lee, J.G.;Choi, I.S.;Moon, I.W.;Kang, Y.S.;Shin, Y.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.217-219
    • /
    • 2003
  • This paper, as a preliminary study, presents the important consideration in laboratory planning and designing 4.2MV impulse voltage generator(IVG), which enable to test and evaluate the UHV dielectric performance of power electric apparatus up to 765kV-class. To fix and confirm the kinds of loads and their capacities to be tested by KERI hereafter, wide investigation and an analysis of test objects, especially heavy electric apparatus of Korea, according to their ratings and test voltages have been conducted. With the special consideration concerning other matters in designing of 4.2MV IVG have been described with the practical examples and references.

  • PDF

A preliminary study on the construction of 4.2MV IVG for the UHV dielectric test (초고압 절연시험을 위한 4.2MV 충격전압발생장치의 구축방안 검토)

  • Lee, J.G.;Shin, Y.J.;Heo, J.C.;Moon, I.W.;Kim, M.H.;Kang, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1750-1752
    • /
    • 2003
  • This paper, as a preliminary study, presents the important consideration in laboratory planning and designing 4.2MV impulse voltage generator(IVG), which enable to test and evaluate the UHV dielectric performance of power electric apparatus up to 765kv-class. To fix and confirm the kinds of loads and their capacities to be tested by KERI hereafter, wide investigation and an analysis of test objects, especially heavy electric apparatus of Korea, according to their ratings and test voltages have been conducted. With the special consideration concerning other matters in designing of 4.2MV IVG have been described with the practical examples and references.

  • PDF

Health Status of Electric Utility Workers Exposed to Extremely Low Frequency Electromagnetic Field (ELF-EMF) (근로자들의 극저주파 전자파 노출 수준에 따른 인체 영향 평가)

  • Park, Kyoung-Ho;Ahn, Yong-Ho;Kim, Tai-Jeon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.3
    • /
    • pp.220-227
    • /
    • 2005
  • Recently, the use of an electrical apparatus has brought up concerns of health risks from exposure to electromagnetic fields. EMF is composed of electric fields and magnetic fields. Heavy exposure to EMF can occur only in the vicinity of high-voltage overhead transmission lines, close to transformers and underground cables, and also close to large electrical machinery. In this thesis I have investigated the hypothesis of the correlation between occupational exposure to ELF-EMF and the risks of leukemia, anemia, cancer. Therefore, the aim of this study is to investigate whether or not ELF-EMF emitted from electric power stations and transformer substations affect some hematological parameters and tumor markers of electric utility workers. The hematological test results and tumor markers under investigation were similar in the two groups but some of parameters such as RBC, AFP, LDH showed significant difference between the two groups from two sample t-test (p<0.05). The exposure group showed increased LDH level compared to the control group by two sample t-tests. In addition, the abnormal LDH level in the exposure group was observed to be clinically significant by ${\chi}^2$-test. However, the levels of RBC, AFP observed were not clinically significant by ${\chi}^2$-test (p>0.05). These results suggested that ELF-EMF does not affect most blood test parameters except LDH of electric utility workers.

  • PDF

The AC Insulation Breakdown Properties of Epoxy/Multi-Alumina Composites for Adding Surface Modified Nano Alumina (표면처리된 나노알루미나가 첨가된 에폭시/멀티-알루미나 콤포지트의 교류절연파괴 특성)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1511-1517
    • /
    • 2016
  • The aim of this study is to improve of properties for electrical AC insulation breakdown strength using epoxy/micro-nano alumina composites with adding glycerol diglycidyl ether (GDE:1,3,5g). This paper deals with the effects of GDE addition for epoxy/micro alumina contents (40,50,60wt%)+surface modified nano alumina(1_phr) composites. 14 kinds specimen were prepared with containing epoxy resins, epoxy micro composites and epoxy nano-micro alumina mixture composites. Average particle size of nano and micro alumina used were 30nm and $1{\sim}2{\mu}m$, respectively. The micro alumina used were alpha phase with Heterogeneous and nano alumina were gamma phase particles of spherical shape. The electrical AC insulation breakdown strength was evaluated by sphere to sphere electrode system and raising velocity 1kV/s. The AC breakdown strength decreased insulation properties of multi-composites according to increasing micro alumina and GDE addition contents.

The development for flooding prevention apparatus of electrical equipment using air pressure (공기압을 이용한 전기설비 침수 방지 장치 개발에 관한 연구)

  • Kim, Gi-Hyun;Jean, Hyun-Jae;Lee, Sang-Ick;Bae, Suk-Myong;Lee, Jae-Yong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.281-284
    • /
    • 2008
  • Inundation of substation and ground power equipment breaks out every summer season in low-lying downtown and low-lying shore by localized heavy rain, typhoon and tidal wave. In case inundation excluding the exchanging cost of equipment, it occurs a great economic and social loss owing to recovery time and events of electric shock occur by inundation electrical equipment(Pad-mounted Transformer and Switch). In case of installing the power equipment at flood danger territory, we are necessary to the product development, the product is that water does not come in the inside the power equipment. Product of pressure maintaining are established on the basic frame and sensor operates at the flooding occurrence and is maintained a shutting tightly structure and it is a method. The product which is produced the reliability of the product it confirmed a flooding yes or no from the condition which puts in the water tank and it verified. We estimate that loss cost which is caused by with flooding and the power failure will be diminished if it is addition to advances the reliability evaluation and a security of the flood protection product.

  • PDF

Effects of Operating Variables on Separation Rate and Separation Efficiency in Ash Separator for Solid Fuel Chemical Looping Combustor (고체연료 매체순환연소기를 위한 회재분리기에서 분리속도 및 분리효율에 미치는 조업변수들의 영향)

  • RYU, HOJUNG;LEE, DONGHO;YOON, JOOYOUNG;JANG, MYOUNGSOO;BAE, DALHEE;PARK, JAEHYEON;BAEK, JEOMIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.2
    • /
    • pp.211-219
    • /
    • 2016
  • To develop an ash separator for the solid fuel chemical looping combustion system, effects of operating variables such as solid injection nozzle velocity, diameter of solid injection nozzle, gap between solid injection line and vent line, vent line inside diameter, and solid intake height on solid separation rate and solid separation efficiency were measured and discussed using heavy and coarse particle and light and fine particles mixture as bed material in an acrylic fluidized bed apparatus. The solid separation rate increased as the solid injection nozzle velocity and the diameter of solid injection nozzle increased. However, the solid separation rate decreased as the gap between solid injection line and vent line, the vent line inside diameter, and the solid intake height increased. The solid separation efficiency was in inverse proportion to the solid separation rate. In this study, we could get high solid separation rate up to 2.39 kg/hr with 91.6% of solid separation efficiency.