태양열주택의 난방성능에 관한 연구 (A Study on the Thermal Performance of a Solar House by a Computer Simulation)

  • 이상천
    • 대한설비공학회지:설비저널
    • /
    • 제7권2호
    • /
    • pp.64-72
    • /
    • 1978
  • The determination of solar collector area requires a thermal simulation to evaluate the performance of a solar house. This study comprises a simulation of system performance including a solar house, flat-plate collectors, a water type storage tank and an auxiliary heater. Developing the steady state performance equations of each equipment, and using the actual monthly average weather data for several recent years, this study evaluates the hourly performance of a solar house model. As a result, it is shown that the desirable collector area in Seoul is 1.4-1.6 times larger than the heating area in the case of non-selective surface, 0.8-1.0 times in the case of selective surface.

  • PDF

지열원 열펌프의 냉.난방 성능 평가 (Cooling and Heating Performance Evaluation of a Ground Source Heat Pump)

  • 손병후;조정식;신현준;안형준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2117-2122
    • /
    • 2004
  • The main objective of the present study is to investigate the performance characteristics of a ground source heat pump (GSHP) system with a 130 m vertical 60.5 mm nominal diameter U-bend ground heat exchanger. In order to evaluate the performance analysis, the GSHP system connected to a test room with 90 $m^2$ floor area in the Korea Institute of Construction Technology ($37^{\circ}39'$ N, $126^{\circ}48'$ E) was designed and constructed. This GSHP system mainly consisted of ground heat exchanger, indoor heat pump and measuring devices. The cooling and heating loads of the test room were 5.5 and 7.2 kW at design conditions, respectively. The experimental results were obtained from July to January in cooling and heating season of $2003{\sim}2004$. The cooling and heating performance coefficients of the system were determined from the experimental results. The average cooling and heating COPs for the system were obtained to be 4.82 and 3.02, respectively. The temperature variations in ground and the ground heat exchanger surface at different depths were also measured.

  • PDF

도시 하수 폐기물의 고주파 건조 (Drying by Microwave Irradiation of Sewage Waste)

  • 박수인;박광하
    • 분석과학
    • /
    • 제10권6호
    • /
    • pp.418-426
    • /
    • 1997
  • 고주파를 이용한 오니의 건조특성에 대하여 살펴보고 재래식 건조특성과 비교 분석하였다. 고주파 건조는 빠른 속도와 높은 효율을 보였다. 재래식 건조에서는 항율건조기간이 나타나지 않았고 수분은 모세관현상에 의하여 이동하였다. 오니의 수분 중 자유수와 결합수는 존재하지 않았다. 고주파 건조에서 감율건조기간이 두 부분으로 나타났으며, 수분의 이동은 확산에 의하여 일어났다. 증발 표면적이 커질수록 수분의 제거가 촉진되었고, 오니의 지름이 커질수록 넓은 범위의 항율건조 기간이 나타났으며, 모양에 따라서도 건조특성이 다르게 나타났다. 고주파 건조에서는 오니의 중심부에서 가장 먼저 온도가 상승하였으며, 항율건조기간에서 $80{\sim}100^{\circ}C$로 일정하게 유지되면서 가장 높았다.

  • PDF

클래드 판재를 사용한 3D 프린터 히팅 블록 개발 (Development of 3D printer heating block using clad plate material)

  • 원대희
    • 한국융합학회논문지
    • /
    • 제8권4호
    • /
    • pp.199-205
    • /
    • 2017
  • 이 연구에서는 3D 프린터 히팅 블록의 발열로 인해 가이드로 열이 전달되어 필라멘트가 녹는 문제점을 개선하기 위해 설계 해석과 폭발압접을 융합한 방법으로 클래드 판재를 만들었다. 클래드 판재에 대한 전단 강도시험을 하였으며, 히팅 블록으로 가공한 다음 열 해석, 열전도도, 열화상 측정 결과 다음과 같은 결론을 얻었다. 구리와 타이타늄 클래드 판재로 만든 히팅 블록에 대하여 3D 모델링 열 해석 한 결과 필라멘트 가이드 부위의 표면온도가 히팅 블록 표면온도 보다 낮은 온도가 예측되었다. 구리와 타이타늄 클래드 판재로 만든 다음 전단 강도를 측정한 결과 평균 195.6MPa 값을 얻었다. 구리와 타이타늄 클래드 판재로 만든 히팅 블록에 대하여 열전도도를 3회 측정한 결과 평균 $62.52W/m{\cdot}K$값을 나타내었다. 구리와 타이타늄 클래드 판재로 만든 히팅 블록에 대하여 열화상 카메라로 표면 온도를 측정한 결과 최대 $107.3^{\circ}C$ 측정되었으며, 필라멘트 가이드 부근에서는 $183.2^{\circ}C$ 측정되었다. 기존 필라멘트의 부위의 온도 보다 $89^{\circ}C$ 낮은 온도 분포를 보였다.

확장표면을 적용한 액체식 제습시스템의 성능특성에 관한 연구 (Performance characterization of liquid desiccant system with extended surface)

  • 장영수;송귀은;이대영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.639-644
    • /
    • 2009
  • This study presents the new idea of liquid desiccant system with extended surface to reduce the system size. The extended surface is inserted between vertical cooling/heating tubes to increase the mass transfer area, and the liquid desiccant flows through the tube wall and the extended surface. Mathematical models for heat and mass transfer between liquid desiccant and air stream at tube wall and extended surface are provided. Dimensionless design parameters governing heat and mass transfer phenomena around the tube and the extended surface are identifier, and dimensionless operating parameters depicting system operating condition including flow rate ratio between dehumidification/regeneration processes, and mass flow rate ratio between air stream and liquid desiccant are explained. The effects of the parameters on system performance are summarized.

  • PDF

고성능 상용튜브를 사용한 태양열 가열 해양온도차발전용 열교환기 설계 최적화 (Design Optimization of Heat Exchangers for Solar-Heating Ocean Thermal Energy Conversion (SH-OTEC) Using High-Performance Commercial Tubes)

  • 주천준;웬반합;이근식
    • 대한기계학회논문집B
    • /
    • 제40권9호
    • /
    • pp.557-567
    • /
    • 2016
  • 태양열 가열을 도입한 해양온도차발전용 열교환기(증발기와 응축기)설계 최적화가 수행되었다. 출력은 100kW이고 작동유체는 R134a이며 고성능 상용튜브를 사용하였다. 열전달면적과 압력강하는 관수의 증가와 관통로수의 감소에 따라 서로 상반되는 경향이 존재하므로 이를 해결하기 위하여, 설비투자비에 관련되는 열전달면적과 압력강하에 관련되는 운전비용 최소화를 고려한 두 목적함수를 갖는 유전자 알고리즘(GA)을 이용하여 다목적설계최적화를 수행하였다. 설계최적화 결과, 구현 가능한 최적의 열전달면적 및 압력강하의 조합들이 적정한 관수 및 관통로 수에 대하여 존재하였다. 도출된 증발기와 응축기의 Pareto 선들은 설계자들에게 재정적인 면을 고려하여 선택할 수 있도록 넓은 범위의 최적해를 제공하였다. 또한, 총열전달면적 중 응축기의 열전달면적이 증발기 쪽보다 크게 나타났다.

지열원 열펌프 시스템의 냉${\cdot}$난방 성능 평가 (Cooling and Heating Performance Evaluation of a GSHP System)

  • 손병후;조정식;신현준;안형준
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.71-81
    • /
    • 2005
  • The main objective of the present study is to investigate the performance characteristics of a ground-source heat pump(GSHP) system with a 130 m vertical and 62 mm nominal diameter U-tube ground heat exchanger. In order to evaluate the performance analysis, the ground-source heat pump connected to a test room with $90\;m^2$ floor area in the Korea Institute of Construction $Technology(37^{\circ}39'N,\;126^{\circ}48'E)$ was designed and constructed. This ground-source heat pump system mainly consisted of ground heat exchanger, indoor heat pumps and measuring devices. The cooling and heating loads of the test room were 5.5 and 7.2 kW at design conditions, respectively. The experimental results were obtained from July 2, 2003 to July 1, 2004. The cooling and heating performance coefficients of the system were determined from the measured data. The average cooling and heating COPs for the system were obtained to be 4.90 and 3.96, respectively. The temperature variations in ground and the ground heat exchanger pipe surface at different depths were also measured.

Influence of Heating Rate and Temperature on Carbon Structure and Porosity of Activated Carbon Spheres from Resole-type Phenolic Beads

  • Singh, Arjun;Lal, Darshan
    • Carbon letters
    • /
    • 제10권3호
    • /
    • pp.181-189
    • /
    • 2009
  • Activated carbon spheres (ACS) were prepared at different heating rates by carbonization of the resole-type phenolic beads (PB) at $950^{\circ}C$ in $N_2$ atmosphere followed by activation of the resultant char at different temperatures for 5 h in $CO_2$ atmosphere. Influence of heating rate on porosity and temperature on carbon structure and porosity of ACS were investigated. Effect of heating rate and temperature on porosity of ACS was also studied from adsorption isotherms of nitrogen at 77 K using BET method. The results revealed that ACS have exhibited a BET surface area and pore volume greater than $2260\;m^2/g$ and $1.63\;cm^3/g$ respectively. The structural characteristics variation of ACS with different temperature was studied using Raman spectroscopy. The results exhibited that amount of disorganized carbon affects both the pore structure and adsorption properties of ACS. ACS were also evaluated for structural information using Fourier Transform Infrared (FTIR) Spectroscopy. ACS were evaluated for chemical composition using CHNS analysis. The ACS prepared different temperatures became more carbonaceous material compared to carbonized material. ACS have possessed well-developed pores structure which were verified by Scanning Electron Microscopy (SEM). SEM micrographs also exhibited that ACS have possessed well-developed micro- and meso-pores structure and the pore size of ACS increased with increasing activation temperature.

접촉 면압에 따른 $Nb_{3}$Sn 도체의 Butt 접합부 특성 (Properties of Butt Joint in $Nb_{3}$Sn Conductors with change of Surface Pressure)

  • 이호진;김기백;김기만
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.253-255
    • /
    • 2002
  • Since a butt Joint is smaller than a lap type joint, it is expected to have smaller AC losses. The butt joint is produced by the diffusion bonding of the contacting surface under pressured and heated condition. It is important to find robust joining conditions, because butt joint has small contact area and has the shape by which the quality of bonding is hard to be checked. In this research, the loading pressure is considered as the joining parameter to find optimum joining condition. The DC resistance of the joint may be changed by the surface pressure during joining process, because the superconducting strands near the contact surface are failed by large plastic deformation. The range from 10 MPa to 18 MPa is expected optimum surface pressure in the conditions of 1 hour heating time and $750^{\circ}C$ temperature in the vacuum furnace.

  • PDF

국부 경화 열처리된 차체 부품의 기계적 성질과 미세조직에 관한 연구 (A Study on Mechanical Properties and Microstructure of Local-Hardening Heat-Treated Automotive Panel)

  • 이재호;정우창
    • 열처리공학회지
    • /
    • 제23권6호
    • /
    • pp.301-308
    • /
    • 2010
  • A steel with chemical composition, 0.22% C, 0.25% Si, 1.26% Mn, 0.22% Cr, 0.04% Ti, 0.0042% B, and a microstructure of ferrite and spheroidized cementite has been press-formed to automotive center pillar followed by local-hardening heat-treatment. Hardness, tensile properties, fractography, microstructure and surface roughness of local-hardening heat-treated automotive center pillar have been examined. The directly heated and quenched area had fully martensitic structure with Vickers hardenss in the range of 500 to 510. The heat affected area close to the directly heated area showed dual-phase structure of ferrite and martensite. The width of the heat-treated and heat-affected areas after the local-hardening heat treatment was ranging from 32 mm to 50 mm. The surface of the local-hardening heat-treated center pillar revealed some temper color as a consequence of the oxidation during the heat treatment, but the surface roughness was not affected by the local-hardening heat treatment.