• Title/Summary/Keyword: Heating speed

Search Result 449, Processing Time 0.026 seconds

Pressureless Sintering and Spark-Plasma Sintering of Fe-TiC Composite Powders (Fe-TiC 복합재료 분말의 상압소결과 방전플라즈마소결)

  • Lee, B.H.;Bae, S.W.;Bae, S.W.;Khoa, H.X.;Kim, Ji Soon
    • Journal of Powder Materials
    • /
    • v.22 no.4
    • /
    • pp.283-288
    • /
    • 2015
  • Two sintering methods of a pressureless sintering and a spark-plasma sintering are tested to densify the Fe-TiC composite powders which are fabricated by high-energy ball-milling. A powder mixture of Fe and TiC is prepared in a planetary ball mill at a rotation speed of 500 rpm for 1h. Pressureless sintering is performed at 1100, 1200 and $1300^{\circ}C$ for 1-3 hours in a tube furnace under flowing argon gas atmosphere. Spark-plasma sintering is carried out under the following condition: sintering temperature of $1050^{\circ}C$, soaking time of 10 min, sintering pressure of 50 MPa, heating rate of $50^{\circ}C$, and in a vacuum of 0.1 Pa. The curves of shrinkage and its derivative (shrinkage rate) are obtained from the data stored automatically during sintering process. The densification behaviors are investigated from the observation of fracture surface and cross-section of the sintered compacts. The pressureless-sintered powder compacts show incomplete densification with a relative denstiy of 86.1% after sintering at $1300^{\circ}C$ for 3h. Spark-plasma sintering at $1050^{\circ}C$ for 10 min exhibits nearly complete densification of 98.6% relative density under the sintering pressure of 50 MPa.

A Fundamental Study on Composting of Garbage (음식물쓰레기의 퇴비화에 관한 기초적 연구)

  • Jeon, Byung-Gwan;Hur, Dang
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.4 no.2
    • /
    • pp.19-25
    • /
    • 1996
  • A fundamental study on composting garbage was performed in a laboratory scale of a high-speed composting reactor. Major parameters were moisture content, temperature and C/N ratio. The results are as follows; pH of the compost was the highest at moisture 60% and anaerobic condition occurred at 70%. It was, also, found that C/N ratio, caused a nitrogen loss due to an occurrence of plentiful $NH_3$. Under controlling Temperature, pH was the highest at $60^{\circ}C$ and an inverse effect for Composting occurred under excessive Temperature as pH at $70^{\circ}C$ was lower than that of soil. The variation of pH and C/N ratio was the lowest when C/N ratio was 25. The results obtained from composting garbage revealed that the best condition of composting occurred under 50 to 60% of moisture content, $60^{\circ}C$ of temperature, and 25 of C/N ratio. It is believed that composting may be finished with in 56 hours if an optimal condition is setting up.

  • PDF

Development of a High-throughput Micronanopatterning System Based on the Plastic Deformation Driven by Continuous Rigid Mold Edge Inscribing on Flexible Substrates (마이크로나노그레이팅 경질 몰드 모서리의 연속적 각인 소성가공 기반 유연 마이크로나노패턴의 고속 연속 제작 공정시스템 개발)

  • Lee, Seungjo;Oh, Dong Kyo;Park, Jaekyu;Kim, Jeong Dae;Lee, Jae Hyuk;Ok, Jong G.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.5
    • /
    • pp.368-372
    • /
    • 2016
  • In this study, we develop a novel high-throughput micronanopatterning system that can implement continuous mechanical pattern inscribing on flexible substrates using a rigid grating mold edge. We perform a conceptual design of the process principle, specific modeling, and buildup of a real system prototype. This research also carefully addresses several important issues related to processing and controlling, including precision motion, alignment, heating, and sensing to enable a successful micronanopatterning in a continuous and high-speed fashion. Various micronanopatterns with the desired profiles can be created by tuning the mold shape, temperature, force, and substrate material toward many potential applications involving electronics, photonics, displays, light sources, and sensors, which typically require a large-area and flexible configurations.

Effect of Mixing Ratio of White and Germinated Brown Rice on the Physicochemical Properties of Extruded Rice Flours (백미와 발아현미의 혼합비율이 압출성형 멥쌀가루의 이화학적 특성에 미치는 효과)

  • Kim, Ji Myoung;Yu, Mengying;Shin, Malshick
    • Korean journal of food and cookery science
    • /
    • v.28 no.6
    • /
    • pp.813-820
    • /
    • 2012
  • To develop the high quality gluten-free rice products with health functionality and desirable texture with moistness, the physicochemical properties of extruded rice flours prepared from the mixture of germinated brown and white rices were investigated. The domestic organic Samgwangbyeo was used to make white and germinated brown rices. White rice (WR) was dried after soaked for 6 h at $15{\pm}3^{\circ}C$ and mixed with germinated brown rice (GBR) with different mixing ratios (100:0, 75:25, 50:50, 25:75, 0:100). The operating conditions of twin screw extruder were 250 rpm of screw speed, $120^{\circ}C$ of barrel temperature, and 25% moisture content of rice flour. The ash, crude protein and crude lipid contents were significantly different (p<0.05) and those of extruded GBR were the highest values, but those of extruded WR were the lowest. The color difference of extruded WR based on white plate showed the lowest among them. The water binding capacity (334.16%), swelling power (8.83 g/g), solubility (33.13%), and total starch (79.50%) were the lowest in extruded GBR. The viscosities of all extruded rice flours by RVA were maintained during heating. The peak and total setback viscosities of extruded rice flours ranged 127-352 and 58.0-85.5 cP, respectively. The novel food biomaterial from germinated brown rice as well as white rice was developed by twin screw extruder. The extruded rice flours control the moistness to improve the texture and also have functional materials, dietary fiber, GABA, and ferulic acid, etc to increase quality of gluten free rice products.

Analytical Study on the Fire Resistance of SC Composite Column (SC 합성기둥의 내화성능에 대한 해석연구)

  • Lim, Yoon Hee;Kang, Seong Deok;Oh, Myoung Ho;Kim, Myeong Han;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.3
    • /
    • pp.335-344
    • /
    • 2007
  • The steel-concrete composite column (i.e., the SC composite column) supports large-gravity loads and simplifies the installation and removal of the work in pouring the concrete. The column takes advantage of the in-plant prefabrication of steel, the speed of erection of a steel structure, and the fire resistance of steel. This paper presents the results of a parametric study using heat transfer analysis and a P-M interaction curve, and compares these results with the experimental results to check the accuracy of the proposed parametric studies. The parametric studies, such as the study of the concrete ratio of an area and the fire protection thickness, provide information on the fire resistance of SC composite columns.

Numerical Simulation of Effect on Atmospheric Flow Field by Development of Coastal Area (임해지역의 개발이 기상장에 미치는 영향예측)

  • Lee, Sang-Deug;Mun, Tae-Ryong
    • Journal of Environmental Science International
    • /
    • v.15 no.10
    • /
    • pp.919-928
    • /
    • 2006
  • The present study applied an atmospheric flow field model in Gwangyang-Bay which can predict local sea/land breezes formed in a complex terrain lot the development of a model that can predict short term concentration of air pollution. Estimated values from the conduct of the atmospheric flow field were used to evaluate and compare with observation data of the meteorological stations in Yeosu and the Yeosu airport, and the effect of micrometeorology of surround region by the coastal area reclamation was predicted by using the estimated values, Simulation results, a nighttime is appeared plainly land breezes of the Gwangyang-bay direction according to a mountain wind that formed in the Mt. of Baekwooun, Mt. of Youngchui. Land winds is formed clockwise circulation in the north, clockwise reverse direction in the south with Gangyang-bay as the center. Compared with model and observation value, Temperature is tend to appeared some highly simulation value in the night, observation value in the daytime in two sites all, but it is veil accorded generally, the pattern of one period can know very the similarity. And also, wind speed and wind direction is some appeared the error of observation value and calculation results in crossing time of the land wind and sea land, it can see that reproducibility is generally good, is very appeared the change land wind in the nighttime, the change of sea wind in the daytime. And also, according to change of the utilization coefficient of soil before and after development with Gwangyang-Bay area as the center. Temperature after development was high $0.55\sim0.67^{\circ}C$ in the 14 hoots, also was tend to appear lowly $0.10\sim0.22^{\circ}C$ in the 02 hours, the change of u, v component is comparatively tend to reduced sea wind and land wind, it is affected ascending air current and frictional power of the earth surface according to inequality heating of the generation of earth surface.

A New Dynamic VRF Heat Hump Simulation Including Frosting and Defrosting Models (착상 및 제상을 포함한 VRF 히트펌프의 동적 수치해석 모델)

  • Park, Noma;Shin, Jeong Seob;Chung, Baik Young;Kim, Byung Soon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.1
    • /
    • pp.1-13
    • /
    • 2015
  • In this study, a new dynamic VRF-type heat pump simulation model is proposed which incorporates frosting and defrosting models. Toward this end, a simple frosting model based on the perfect analogy, and lumped system based defrost model, are proposed. Then, frosting and defrosting models are incorporated into a dynamic heat pump model which adopts segment-by-segment local heat exchanger model and map-based variable speed compressor model. Thus, the model can naturally represent locally uneven frosting and defrosting on the heat exchanger surface. Developed simulation model is validated against available experimental data to show good agreement within 10% error for capacity and COP. Finally, developed dynamic heat pump model is applied to annual heating season simulation to show that seasonal COP of heat pump is degraded by 7% due to frosting and defrosting.

Development of the Inverter System with UPS Function for the Air-Conditioning Blower (UPS 기능을 갖는 A/C Blower용 인버터 시스템 개발)

  • Lim, Seung-Beom;Lee, Yun-Ha;Mok, Hyung-Soo;Ji, Jun-Keun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.302-308
    • /
    • 2011
  • The HVAC(Heating Ventilation and Air Conditioning) system is only controlled by turn on/turn off operations with AC 380V input. Therefore, the efficiency of the system is reduced and accoustic noise problem occurs. Also, the blower is shut down at the AC power failure. In this paper, the inverter system with UPS function for the A/C(Air Conditioning) blower is proposed. Proposed inverter system which is powered from the AC and DC voltage can control speed, operation mode, and soft-start time using CAN communication. In case of the CAN communication failure, RS-232 communication could be used to control the hardware directly by the engineer that can solve existing problems. To verify the validity of proposed inverter system, simulations and experiments are carried out.

Development of Grain Heater Using Engine Exhaust Gas (내연기관(內燃機關) 배기(排氣)가스를 이용(利用)한 곡물가열기(穀物加熱機) 개발(開發))

  • Suh, S.R.;Harris, F.D.
    • Journal of Biosystems Engineering
    • /
    • v.10 no.2
    • /
    • pp.1-11
    • /
    • 1985
  • A double pipe grain heater using engine exhaust gas as a heat source was developed. The performance of the grain heater was examined with soybeans as a test material experimentally and numerically using a mathematical model constructed. The following conclusions were drawn: 1. The modified screw conveyor used in the grain heater has a characteristic of decreasing capacity with increasing speed at speeds above 60 rpm. Operation with speeds below 60 rpm is recommended. 2. Heating soybeans by the heater at soybean flow rate up to 100 kg/hr, inlet temperature of the exhaust gas to the heater are recommended as above $400^{\circ}C$, $300^{\circ}C$, and $200^{\circ}C$ roughly for a 2, 5, and 10 kW engine, respectively. 3. Temperature increments of soybean by the heater at soybean flow rates ranged from 25 to 100 kg/hr are in the ranges of $6^{\circ}C-35^{\circ}C$, $15^{\circ}C-88^{\circ}C$, and $15^{\circ}C-140^{\circ}C$ with exhaust gas from a 2, 5, and 10 kW engine, respectively, at an exhaust temperature of $500^{\circ}C$. 4. Thermal efficiency of the heater at soybean flow rates ranged from 25 to 100 kg/hr are in the ranges of 35-37%, 28-34%, and 20-29% with exhaust gas from a 2, 5, and 10 kW engine, respectively. 5. The grain heater can be used to heat the other grain, also, without any bad effect from the exhaust gas used as a heat source.

  • PDF

An Analysis of Thermal Conductivity of Ceramic Fibrous Insulator by Modeling & Simulation Method I (모델링/시뮬레이션 기법을 이용한 세라믹 섬유 단열재의 열전도도 해석 I)

  • Kang, Hyung;Baek, Yong-Kee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.83-95
    • /
    • 2002
  • Thermal conductivity of ceramic fibrous insulator was analysed and predicted by using the modeling/simulation technique. Ceramic fibrous insulators are widely used as high temperature insulator on account of their lightweight mass and heat resisting properties. Especially it is suitable to protect the high speed aircraft and missiles from severe aero-thermodynamic heating. Thermal conductivity of ceramic fibrous insulator could be determined from the conductive heat transfer and the radiative heat transfer through the insulator. In order to estimate conductive thermal conductivity, homogenization technique was applied, while radiative thermal conductivity was computed by means of random number and radiation probability. Particularly radiation probability can make it possible to estimate the conductivity of fibrous insulator without any experimental constant. The calculated conductivity predicted in the present study have a reasonable accuracy with an average error of 7 percent to experimental data.