• Title/Summary/Keyword: Heating source

Search Result 901, Processing Time 0.03 seconds

Experimental Study on $CO_2$ Level Fluctuation by Door-opening of Subway (전동차 출입문 개폐에 따른 객실 이산화탄소 농도변화의 실험적 연구)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Park, Eun-Young;Kim, Se-Young;Jung, Mi-Young;Ham, Dae-Joo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1652-1655
    • /
    • 2008
  • Indoor air quality (IAQ) of subway becomes a key issue as the IAQ guidelines for public transportation published. There are two major sources regarding IAQ of subway; One is the sources coming from outdoor air and the other is sources of inside. Particulate matters smaller than 10 micrometer (PM10) and carbon dioxide ($CO_2$) are recognized as the one of the most severe pollutants in Korea. The source of PM10 is mainly coming from outdoor air, however, the source of $CO_2$ is coming from passengers exhaust. According to the guidelines, the level of $CO_2$ should be lower than 2500ppm for normal operating time and lower than 3500ppm for rush hour. In order to satisfy these guidelines, the volume of mechanical ventilation should be increase which consumes extra energy for heating or cooling. Therefore, the optimum volume of mechanical ventilation should be calculated for energy saving. In this study, we measured the natural ventilation rate by door-opening which can reduce the load of mechanical ventilation. The $CO_2$ generator and sensors were used to measure the change of $CO_2$ by periodic door-opening of subway.

  • PDF

Cooling Water Utility of Future Clean Energy Source KSTAR (미래 청정에너지원 KSTAR의 냉각수설비)

  • Lee, J.M.;Kim, Y.J.;Park, D.S.;Lim, D.S.
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.596-601
    • /
    • 2006
  • Because of insufficiency of energy resources and pollution of environment, it is necessary to develop alternative energy sources. Nuclear fission energy is used widely for source of electric Power but being restricted due to radioactivity problem. Nuclear fission is highlighted as the new generation of nuclear energy and researched worldwide because of low risk of radiation effect. The representatives of fusion research is China's EAST, KSTAR of Korea and ITER of world. Korea Superconducting Tokamak Advanced Research(KSTAR) project is on progress for the completion in August, 2007. In this study, the research of utility system for KSTAR be carried out. The utility system of KSTAR is consist of water cooling & heating system, $N_2$ gas system, DI water system, service water system and instrument air & auto control system. The progress of KSTAR utility system is under commissioning state after construction completion. The optimal operation scenario will be verified during commissioning and adopted to the KSTAR operation.

  • PDF

A Study on Design for Energy-saving Based on Analysis of Current Situation in School Facilities (학교시설 현황분석을 통한 에너지절약설계 개선방향 연구)

  • Meang, Joon-Ho;Kim, Sung-Joong;Lee, Seung-Min;Ko, Hyun-Su
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.17 no.3
    • /
    • pp.1-8
    • /
    • 2018
  • We suggest improvement direction of energy-saving design based on analysis of current situation in school facilities. School facilities have large area among public buildings. While the number of students is decreasing, the number of school and energy consumption is increasing year after year. School facilities have excellent heat insulation property, but it requires further examination about excessive heat insulation plan. School facilities are using gas heat pump actively for cooling and heating, but has difference in use ratio of ground source heat pump by region. Thus School facilities requires active using of ground source heat pump and BIPV(Building Integrated Photovoltaic System).

Simulation Analysis of Bio-Methane Decomposition Using Solar Thermal Energy (태양열 이용 바이오메탄 분해 해석연구)

  • Kim, Haneol;Lee, Sangnam;Lee, Sang Jik;Kim, Jongkyu
    • New & Renewable Energy
    • /
    • v.17 no.1
    • /
    • pp.40-49
    • /
    • 2021
  • In this study, the optical properties, heat transfer capabilities and chemical reaction performance of a methane thermal decomposition reactor using solar heat as a heat source were numerically analyzed on the basis of the cavity shape. The optical properties were analyzed using TracePro, a Monte Carlo ray tracing-based program, and the heat transfer analysis was performed using Fluent, a CFD program. An indirect heating tubular reactor was rotated at a constant speed to prevent damage by the heat source in the solar furnace. The inside of the reactor was filled with a porous catalyst for methane decomposition, and the outside was insulated to reduce heat loss. The performance of the reactor, based on cavity shape, was calculated when solar heat was concentrated on the reactor surface and methane was supplied into the reactor in an environment with a solar irradiance of 700 W/㎡, a wind speed of 1 m/s, and an outdoor temperature of 25℃. Thus, it was confirmed that the heat loss of the full-cavity model decreased to 13% and the methane conversion rate increased by 33.5% when compared to the semi-cavity model.

Thermal load analysis of tank culture system for applying seawater source heat pump (육상 수조식 양식장의 해수 열원 히트펌프 시스템 적용을 위한 열부하 분석)

  • Min-Gi YOON;Tae-Hoon KIM;Seok-Kwon JEONG
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.59 no.2
    • /
    • pp.155-163
    • /
    • 2023
  • This study deals with the maximum thermal load analysis and optimal capacity determination method of tank culture system for applying seawater source heat pump to save energy and realize zero energy. The location of the fish farm was divided into four sea areas, and the heat load in summer and winter was analyzed, respectively. In addition, two representative methods, the flow-through aquaculture system and the recirculation aquaculture system were reviewed as water treatment methods for fish farms. In addition, the concept of the exchange rate was introduced to obtain the maximum heat load of the fish farms. Finally, power consumption for heat pumps was analyzed in the view point of sea areas, tank capacity, and exchange rate based on the calculated maximum thermal load.

A Study on An Integrated GEO/TES with Geothermal Heat Exchanger and Thermal Ice Storage (지중열 교환기와 빙축열조(Thermal Ice Storage)를 연계시킨 통합 지중열-빙축열조 시스템(Integrated GEO/TES))

  • Lohrenz ED.;Hahn Jeongsang;Han Hyuk Sang;Hahn Chan;Kim Hyoung Soo
    • Economic and Environmental Geology
    • /
    • v.38 no.6 s.175
    • /
    • pp.717-729
    • /
    • 2005
  • Peak cooling load of large buildings is generally greater than their peak heating load. Internal and solar heat gains are used fur selection of adquate equipment in large building in cold winter climate like Canada and even Korea. The cost of geothermal heat exchanger to meet the cooling loads can increase the initial cost of ground source heat pump system to the extend less costly conventional system often chosen. Thermal ice storage system has been used for many years in Korea to reduce chiller capacity and shift Peak electrical time and demand. A distribution system designed to take advantage of heat extracted from the ice, and use of geothermal loop (geothermal heat exchanger) to heat as an alternate heat source and sink is well known to provide many benifits. The use of thermal energy storage (TES) reduces the heat pump capacity and peak cooling load needed in large building by as much as 40 to $60\%$ with less mechanical equipment and less space for mechanical room. Additionally TES can reduce the size and cost of the geothermal loop by 1/3 to 1/4 compared to ground coupled heat pump system that is designed to meet the peak heating and cooling load and also can eliminate difficuties of geothermal loop installation such as space requirements and thermal conditions of soil and rock at the urban area.

An Experimental Study of Synthesis and Characterization of Vanadium Oxide Thin Films Coated on Metallic Bipolar Plates for Cold-Start Enhancement of Fuel Cell Vehicles (연료전지 차량의 냉시동성 개선을 위한 금속 분리판 표면의 바나듐 산화물 박막 제조 및 특성 분석에 관한 연구)

  • Jung, Hye-Mi;Noh, Jung-Hun;Im, Se-Joon;Lee, Jong-Hyun;Ahn, Byung-Ki;Um, Suk-Kee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.6
    • /
    • pp.585-592
    • /
    • 2011
  • The enhancement of the cold-start capability of polymer electrolyte fuel cells is of great importance in terms of the durability and reliability of fuel-cell vehicles. In this study, vanadium oxide films deposited onto the flat surface of metallic bipolar plates were synthesized to investigate the feasibility of their use as an efficient self-heating source to expedite the temperature rise during startup at subzero temperatures. Samples were prepared through the dip-coating technique using the hydrolytic sol-gel route, and the chemical compositions and microstructures of the films were characterized by X-ray diffraction, X-ray photoelectron spectroscopy, and field-emission scanning electron microscopy. In addition, the electrical resistance hysteresis loop of the films was measured over a temperature range from -20 to $80^{\circ}C$ using a four-terminal technique. Experimentally, it was found that the thermal energy (Joule heating) resulting from self-heating of the films was sufficient to provide the substantial amount of energy required for thawing at subzero temperatures.

Studies on the Amylase Produced by Candida muscorum (Candida muscorum의 Amylase에 관(關)한 연구(硏究))

  • Park, Yoon-Joong;Yoon, Han-Kyo;Son, Cheon-Bae
    • Korean Journal of Food Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.243-249
    • /
    • 1975
  • This experiment were carried out to investigate the conditions of amylase produced by Candida muscorum in wheat bran cultures and the properties of its amylase (crude enzyme). The results obtained were as follows. 1. The optimum conditions for amylase production in wheat bran cultures were; water content 75 percent, temperature $25^{\circ}C$ and incubation time 4-7 days. 2. The production of amylase was increased about 20 percent in the medium added 0.5 percent of ammonium sulfate or ammonium chloride to wheat bran, but the production of those was decreased in the case of addition of nitrates. 3. No significant effect was found in the case of the addition of carbon source on the production of amylase. 4. The properties of liquefying amylase of the selected strain were; the optimum pH 4.2, the optimum temperature $60-65^{\circ}C$, the stable pH 3.2-6.8 and the stable heating (for 15 minutes heating) below $65^{\circ}C$. 5. The properties of saccharifying amylase of the selected strain were; the optimum pH 4.5, the optimum temperature $55^{\circ}C$, the stable pH 3.8-6.2 and the stable heating (for 15 minutes heating) below $45^{\circ}C$.

  • PDF

Inventory of Carbon Dioxide Emission in Carbon Cycle Community (The case study on Gyeongbuk Bonghwa-gun Chunyang-myeon Seobyeok-ri) (탄소순환마을의 이산화탄소배출량 조사연구 (경상북도 봉화군 춘양면 서벽리를 중심으로))

  • Kim, Hyo-Jin;Byun, Woo-Hyuk;Lim, Min-Woo;Park, Won-Kyoung;Kim, Min-Su
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.4
    • /
    • pp.597-602
    • /
    • 2010
  • The most basic matter to establish forest carbon circulation village is statistic on greenhouse gas emissions. But currently, although there is statistic on greenhouse gas emissions in the level of city or province, there is not statistic on greenhouse gas emission in village unit. According to the results, The model area is located in Seobyeok-ri, Chunyang-myeon, Bonghwa-gun, Gyeongsangbuk-do, the total $CO_2$emissions caused by energy used in the model area was $1,755tCO_2$. Heating accounts for 55% of total emissions followed by 23% for power and 22% for vehicles. The model area emitted $572tCO_2$ due to rice growing and livestock raising, accounting for approximately 24.5% of total $CO_2$ emissions. It is expected that a reduction of as much as $884tCO_2$ emissions will be made from the current $964tCO_2$ to a level of 1/12th that amount, or $80tCO_2$ by replacing heating energy currently used in the model area with wood bioenergy such as wood chips or pellets. In addition, carbon emission reduction is expected for both heating and power by replacing the power consumption in houses, buildings, and street lights with solar power.

Development of Semi-basement Type Greenhouse Model for Energy Saving

  • Kim, Seoung Hee;Joen, Jong Gil;Kwon, Jin Kyeong;Kim, Hyung Kweon
    • Journal of Biosystems Engineering
    • /
    • v.41 no.4
    • /
    • pp.328-336
    • /
    • 2016
  • Purpose: The heat culture areas of greenhouses have been continuously increasing. In the face of international oil price fluctuations, development of energy saving technologies is becoming essential. To save energy, auxiliary heat source and thermal insulation technologies are being developed, but they lack cost-efficiency. The present study was conducted to save energy by developing a conceptually new semi-basement type greenhouse. Methods: A semi-basement type greenhouse, was designed and constructed in the form of a three quarter greenhouse as a basic structure, which is an advantageous structure to inflow sunlight. To evaluate the performance of the developed greenhouse, a similar structured general greenhouse was installed as a control plot, and heating tests were conducted under the same crop growth conditions. Results: Although shadows appeared during the winter in the semi-basement type greenhouse due to the underground drop, the results of crop growth tests indicated that there were no differences in crop growth and development between the semi-basement type greenhouse and the control greenhouse, indicating that the shadows did not affect the crop up to the height of the crop growing point. The amount of fuel used for heating from January to March was almost the same between the two greenhouses for tests. The heating load coefficients of the experimental greenhouses were calculated as $3.1kcal/m^2{\cdot}^{\circ}C{\cdot}h$ for the semi-basement type greenhouse and $2.9kcal/m^2{\cdot}^{\circ}C{\cdot}h$ for the control greenhouse. Since the value is lower than the double layer PE (polyethylene) film greenhouse value of $3.5kcal/m^2{\cdot}^{\circ}C{\cdot}h$ from a previous study, Tthe semi-basement type greenhouse seemed to have energy saving effects. Conclusions: The semi-basement type greenhouse could be operated with the same fuel consumption as general greenhouses, even though its underground portion resulted in a larger volume, indicating positive effects on energy saving and space utilization. It was identified that the heat losses could be reduced by installing a thermal curtain of multi-layered materials for heat insulation inside the greenhouse for the cultivation of horticultural products by installing thermal curtain of multi-layered materials for heat insulation inside the greenhouse, it was identified that the heat losses could be reduced.