• 제목/요약/키워드: Heating period

검색결과 539건 처리시간 0.026초

마이크로파 가열에 의한 토양 유기오염물질 탈착특성 (Desorption Characteristics of Volatile Organics Compounds in Soil by Microwave Heating)

  • 문경환;김덕찬
    • 환경위생공학
    • /
    • 제11권2호
    • /
    • pp.65-73
    • /
    • 1996
  • The objective of this study is to investigate the removal efficiency of volitile organic compounds in soil, and the mechanism of desorption by bench scale microwave heating, Silt soil used for experiment and was impregnated with toluene, tetrachloroethylene, o-xylene and p-dichlorobenzene and the microwave treatment was conducted in a modified domestic microwave oven : 2450MHz, 700W. According to the results of the research the removal efficiency was improved with increasing water contents and the soil temperature appeared to plateau period extending to 2-3minutes corresponds to the temperature a which steam distillation was expected. The value of removal rate constant (k) were calculated on dry and moisty silt soil, respectively, which showed linear with increasing microwave heating time. Therefore, addition of a certain amount of water to the contaminated soil can efficiently enhance the ability of the soil to absorb microwave energy and promote the evaporation of the volitile contaminants.

  • PDF

비모수 지역난방 수요예측모형 (A Nonparametric Prediction Model of District Heating Demand)

  • 박주헌
    • 자원ㆍ환경경제연구
    • /
    • 제11권3호
    • /
    • pp.447-463
    • /
    • 2002
  • The heat demand prediction is an essential issue in management of district heating system. Without an accurate prediction through the lead-time period, it might be impossible to make a rational decision on many issues such as heat production scheduling and heat exchange among the plants which are very critical for the district heating company. The heat demand varies with the temperature as well as the time nonlinearly. And the parametric specification of the heat demand model would cause a misspecification bias in prediction. A nonparametric model for the short-term heat demand prediction has been developed as an alternative to avoiding the misspecification error and tested with the actual data. The prediction errors are reasonably small enough to use the model to predict a few hour ahead heat demand.

  • PDF

Modeling of GN type III with MDD for a thermoelectric solid subjected to a moving heat source

  • Ezzat, Magdy A.
    • Geomechanics and Engineering
    • /
    • 제23권4호
    • /
    • pp.393-403
    • /
    • 2020
  • We design the Green-Naghdi model type III (GN-III) with widespread thermoelasticity for a thermoelectric half space using a memory-dependent derivative rule (MDD). Laplace transformations and state-space techniques are used in order to find the general solution for any set of limit conditions. A basic question of heat shock charging half space and a traction-free surface was added to the formulation in the present situation of a traveling heat source with consistent heating speed and ramp-type heating. The Laplace reverse transformations are numerically recorded. There are called the impacts of several calculations of the figure of the value, heat source spead, MDD parameters, magnetic number and the parameters of the ramping period.

MHD발전용 작동 플라즈마를 고온가열하기 위한 효율적 방안에 관한 연구 (Studies on a Effective Scheme to Obtain High Temperature Working Plasma for MHD Power Generation)

  • 김윤식;노창주;김영길;공영경;최춘성
    • 대한기계학회논문집
    • /
    • 제17권1호
    • /
    • pp.153-161
    • /
    • 1993
  • 본 연구에서는 각 운전모드별 열특성을 전체적으로 고려하여 양질의 MHD발전 용 작동플라즈마를 얻기 위하여 필요한 효과적인 방책에 관하여 집중적으로 고찰하고 자 한다.

가솔린엔진의 연료 미립화 향상을 위한 공급연료 가열에 대한 실험적 연구 (An Experimental Study on the Fuel Heating for Enhancing Fuel Atomization)

  • 윤팔주;박승범;선우명호;천동필
    • 한국자동차공학회논문집
    • /
    • 제9권4호
    • /
    • pp.112-120
    • /
    • 2001
  • Poor fuel vaporization in gasoline engines causes the problem of HC emission during the cold start and warm-up period. This paper presents a strategy to improve fuel atomization during the warm-up phase. In this experiment, the heated fuel-rail system is constructed to investigate the effects of fuel heating on the average size of fuel droplets. The fuel atomization effects are examined by measuring Sauter Mean Diameter (SMD) of the fuel droplets from the three different types (two-hole, pintle, and six-hole) of injectors based upon a returnless heated fuel-rail system. The results show that the six-hole type injector is the most sensitive to fuel heating in terms of SMD among three different types of injectors.

  • PDF

6kW급 태양열 온수급탕 시스템의 실증실험 및 분석(제1보 실증실험) (Verification Experiment and Analysis for 6 kW Solar Water Heating System(Part 1: Verification Experiment))

  • 김진홍;김성수;최봉수;홍희기
    • 설비공학논문집
    • /
    • 제16권2호
    • /
    • pp.128-134
    • /
    • 2004
  • In order to verify and take measures against a variety of troubles which cannot be predicted in a well-controlled laboratory, it is necessary that solar system should be experimented in an actual situation during a long period. Through this experiment it can be also understood how the load pattern and operational conditions expected in a design process become different to those in the actual running, which can be applied to a new system design. We installed 6 kW solar hot water heating system with a shower facility and operated during 7 months. As a result, average 8.3 persons took a shower a day; solar fraction is 71% and total collector efficiency is 40% during the periods from March to September. We confirmed several troubles encountered in the actual situation and considered practical center-measures.

혼합유중(混合油中) Tocopherol의 열산화(熱酸化)에 미치는 대두(大豆) Lecithin의 효과(效果) (Effect of Soybean Lecithin on the Thermal Oxidation of Tocopherol in Blended Oil)

  • 장현기
    • 한국응용과학기술학회지
    • /
    • 제10권2호
    • /
    • pp.1-6
    • /
    • 1993
  • The blended oil was prepared from cottonseed oil and palm olien. The oxidative stability of blended oil after the addition of natural tocopherol and soybean lecithin during heating was investigated and the effects of lecithin were evaluated. The result obtained were as follows: 1. When the concentration of palm olein in blended oil during heating was increased, the oxidative stability was improved. 2. By both addition of natural tocopherol and soybean lecithin during heating in blended oil, induction period was considerably increased and residual ratio of tocopherol was high. 3. The oxidative stability of potato chips prepared from blended oil was higher in the prsence of lecithin than in the absence of it.

ATES 열펌프 시스템 성능 및 경제성 분석에 관한 연구 (Study on the Performance of an ATES Geothermal Heat Pump System and Economic Analysis)

  • 오명석;최종민
    • 설비공학논문집
    • /
    • 제24권4호
    • /
    • pp.289-296
    • /
    • 2012
  • The aim of this study is to investigate the performance of a heating and cooling system with aquifer thermal energy storage(ATES heat pump system) known as one of the underground thermal energy storage application systems. The ATES system was composed of heat pump unit and ATES, which was installed in a factory building located in Anseoung. The system represented very high heating and cooling performance, and showed nearly constant COP at each heating and cooling season due to the stability of EWT. The economic analysis about an ATES system and a conventional system was also executed. The conventional system adopted an air-conditioner in the summer season and a LNG boiler in the winter season. The payback period of the ATES system was estimated by 6.62 years.

임대아파트 유형별 유지관리비와 거주자의 리모델링 의식비교 (The Comparison of Maintenance Cost and Residents′Consciousness of Remodeling by Rental Apartment Types)

  • 박민용;장승재
    • 한국주거학회논문집
    • /
    • 제14권4호
    • /
    • pp.69-76
    • /
    • 2003
  • Considering the present development situation of rental apartment since 1982, the supply of rental housing for low-income dwellers has contributed a amount of quantities, but has been deficient qualities in housing policy. To propose the device of remodeling for low-income dwellers in deteriorated apartment, this study investigated the characteristics of maintenance cost and the residents'consciousness of remodeling by rental apartment types. The results of this study were as follows; The annual maintenance cost of permanent rental apartment was 14,249 won/$\textrm{m}^2$$.$yr, that of fifty years period rental apartment was 13,372 won/$\textrm{m}^2$$.$yr. In the case of remodeling in deteriorated heating system, the principal decision factor of choice was showed “economics” as priority. Residents in rental apartment preferred remodeling to reconstruction, and unit heating system to central heating system.

Stress Corrosion Cracking of Heat Exchanger Tubes in District Heating System

  • Cho, Sangwon;Kim, Seon-Hong;Kim, Woo-Cheol;Kim, Jung-Gu
    • Corrosion Science and Technology
    • /
    • 제18권2호
    • /
    • pp.49-54
    • /
    • 2019
  • The purpose of this paper is to present failure analysis, of the heat exchanger tube in a district heating system. SS304 stainless steel is used, as material for the heat exchanger tube. The heat exchanger operates in a soft water environment containing a small amount of chloride ions, and regularly repeats operation and standstill period. This causes concentration of chloride ions on the outer surface of the tube, as well as repeat of thermal expansion, and shrinkage of the tube. As a result of microscopic examination, cracks showed transgranular as well as branched propagation, and many pits were present, at the initiation point of each crack. Energy disperstive spectroscopy analysis showed Fe and O peak, as well as Cl peak, meaning that cracks were affected by Cl ion. Failure of the tube was caused by chloride-induced stress corrosion cracking by thermal stress, high temperature, and localized enrichment of chloride ions.