• 제목/요약/키워드: Heating load

검색결과 892건 처리시간 0.036초

표준기상 데이터와 열해석을 이용한 태양광열 모듈의 필요 냉각수량 산출 (Calculation of Required Coolant Flow Rate for Photovoltaic-thermal Module Using Standard Meteorological Data and Thermal Analysis)

  • 이천규;정효재
    • 반도체디스플레이기술학회지
    • /
    • 제21권4호
    • /
    • pp.18-22
    • /
    • 2022
  • Photovoltaics (PV) power generation efficiency is affected by meteorological factors such as temperature and wind speed. In general, it is known that the power generation amount decreases because photovoltaics panel temperature rises and the power generation efficiency decreases in summer. Photovoltaics Thermal (PVT) power generation has the ad-vantage of being able to produce heat together with power, as well as preventing the reduction in power generation efficien-cy and output due to the temperature rise of the panel. In this study, the amount of heat collected by season and time was calculated for photovoltaics thermal modules using the International Weather for Energy Calculations (IWEC) data provided by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). Based on this, we propose a method of predicting the temperature of the photovoltaics panel using thermal analysis and then calculating the flow rate of coolant to improve power generation efficiency. As the results, the photovoltaics efficiencies versus time on January, April, July, and October in Jeju of the Republic of Korea were calculated to the range of 15.06% to 17.83%, and the maxi-mum cooling load and flow rate for the photovoltaics thermal module were calculated to 121.16 W and 45 cc/min, respec-tively. Though this study, it could be concluded that the photovoltaics thermal system can be composed of up to 53 modules with targeting the Jeju, since the maximum capacity of the coolant circulation pump of the photovoltaics thermal system applied in this study is 2,400 cc/min.

건물일체형 패널형 벽면녹화 식재기반 유형별 건물에너지 성능 분석 (Analysis of Building Energy Reduction Effect based on the Green Wall Planting Foundation Type Using a Simulation Program)

  • 김정호;권기욱;윤용한
    • 한국환경생태학회지
    • /
    • 제29권6호
    • /
    • pp.936-946
    • /
    • 2015
  • 본 연구는 도심의 열환경 개선 및 건물에너지저감 효과가 입증된 벽면녹화 중 기존 건물에 적용 가능한 패널형 벽면녹화 식재기반 유형에 따른 건물에너지 저감 성능을 분석하고자 하였다. 식재기반 유형은 총 4가지 유형으로 하였으며, Case A는 벽면녹화가 미적용된 유형으로 콘크리트 + 단열재로 구성하였다. Case B는 식재층 + 무기다공성블록 + 콘크리트 + 단열재로 구성하였으며, Case C는 식재층 + 코코피트블록 + 콘크리트 + 단열재로 구성하였다. Case D는 식재층 + 마사토블록 + 콘크리트 + 단열재로 구성하였다. 분석항목으로는 열전도율, 열관류율, 건물에너지시뮬레이션을 실시하였다. 식재기반 유형별 열전도율은 Case C(0.053W/mK) > Case B(0.1W/mK) > Case D(0.17W/mK)의 순이었다. 에너지시뮬레이션 결과 중 단위면적당 냉방피크부하저감은 미적용인 Case A 대비 Case C(1.19%) > Case B(1.14%) > Case D(1.01%)이며, 난방피크부하저감은 Case A 대비 Case C(2.38%) > Case B(1.82%) > case D(1.50%)로 산정되었다. 연간 냉 난방부하저감은 미적용 Case A대비 벽면녹화 유형에서 0.92~1.28% 저감률을 나타내었다. 연간 냉난방에너지사용량은 3.04~3.22%의 저감률을 보였으며, 1차에너지사용량은 Case A대비 나머지 유형에서 평균 5,844 kWh/yr의 저감량을 보였다. 연간 이산화탄소발생량은 벽면녹화 미적용 Case A대비 평균 996kg 저감량을 보였다. 식재위치별 에너지성능평가 결과 동향 > 서향 > 남향 > 북향 순이었다. 벽면녹화비율에 따른 에너지성능평가 결과 녹화 비율이 높아짐에 따라 양호한 결과를 나타내었으며, 20~80%의 비율보다 100% 녹화시 약 2배의 저감률을 보였다.

설비공학 분야의 최근 연구 동향: 2008년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2008)

  • 한화택;최창호;이대영;김서영;권용일;최종민
    • 설비공학논문집
    • /
    • 제21권12호
    • /
    • pp.715-732
    • /
    • 2009
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2008. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends in thermal and fluid engineering have been surveyed in the categories of general fluid flow, fluid machinery and piping, new and renewable energy, and fire. Well-developed CFD technologies were widely applied in developing facilities and their systems. New research topics include fire, fuel cell, and solar energy. Research was mainly focused on flow distribution and optimization in the fields of fluid machinery and piping. Topics related to the development of fans and compressors had been popular, but were no longer investigated widely. Research papers on micro heat exchangers using nanofluids and micro pumps were also not presented during this period. There were some studies on thermal reliability and performance in the fields of new and renewable energy. Numerical simulations of smoke ventilation and the spread of fire were the main topics in the field of fire. (2) Research works on heat transfer presented in 2008 have been reviewed in the categories of heat transfer characteristics, industrial heat exchangers, and ground heat exchangers. Research on heat transfer characteristics included thermal transport in cryogenic vessels, dish solar collectors, radiative thermal reflectors, variable conductance heat pipes, and flow condensation and evaporation of refrigerants. In the area of industrial heat exchangers, examined are research on micro-channel plate heat exchangers, liquid cooled cold plates, fin-tube heat exchangers, and frost behavior of heat exchanger fins. Measurements on ground thermal conductivity and on the thermal diffusion characteristics of ground heat exchangers were reported. (3) In the field of refrigeration, many studies were presented on simultaneous heating and cooling heat pump systems. Switching between various operation modes and optimizing the refrigerant charge were considered in this research. Studies of heat pump systems using unutilized energy sources such as sewage water and river water were reported. Evaporative cooling was studied both theoretically and experimentally as a potential alternative to the conventional methods. (4) Research papers on building facilities have been reviewed and divided into studies on heat and cold sources, air conditioning and air cleaning, ventilation, automatic control of heat sources with piping systems, and sound reduction in hydraulic turbine dynamo rooms. In particular, considered were efficient and effective uses of energy resulting in reduced environmental pollution and operating costs. (5) In the field of building environments, many studies focused on health and comfort. Ventilation. system performance was considered to be important in improving indoor air conditions. Due to high oil prices, various tests were planned to examine building energy consumption and to cut life cycle costs.

설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012)

  • 한화택;이대영;김사량;김현정;최종민;박준석;김수민
    • 설비공학논문집
    • /
    • 제25권6호
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.

옥상온실에서의 여름철 엽채류 작물에너지 교환 모델 개발 (Development of Summer Leaf Vegetable Crop Energy Model for Rooftop Greenhouse)

  • 조정화;이인복;이상연;김준규;크리스티나;최영배;이민형;정효혁;정득영
    • 생물환경조절학회지
    • /
    • 제31권3호
    • /
    • pp.246-254
    • /
    • 2022
  • 본 연구는 급속하게 성장하는 시설농업과 동시에 증가하는 에너지 사용량 및 탄소배출량을 저감하기 위해, 온실의 에너지 부하를 동적으로 분석하기 위한 작물에너지의 다중 회귀모델 개발을 수행하였다. 온실은 연중 안정적인 대량 생산을 위한 적절한 환경을 조성하기 위해 에너지 투입이 필요하다. 도시농업의 일종인 옥상온실 플랫폼을 통해 건물에서 버려지거나 활용되지 않는 에너지를 옥상온실에서 사용할 수 있다. 옥상온실의 효율적인 운영을 위해서는 다양한 환경 조건에 대한 동적 에너지 분석이 선행되어야 하며, 온실에 도입되는 태양 에너지의 40-75%가 작물을 위한 에너지 교환이므로 필수적으로 고려되어야 한다. 한국기계연구원 내 옥상온실에서 여름철에 청경채를 재배하며 생장단계에 따른 에너지 교환을 분석하였다. 작물을 중심으로 미기상 및 양액 환경 분석과 생장 특성 조사를 수행하였다. 정식일수에 따른 엽면적지수를 추정하였으며, 개발된 수식은 결정계수 0.99로 분석되었다. 또한 작물에너지 흐름에 지배적인 잎 표면온도로부터의 현열부하와 증발산에 의한 잠열부하로 나누어 모델을 개발하였다. 엽온과 증발산량을 각각 다중 회귀모델을 이용하여 추정하고 실측한 값을 비교해 보았을 때, 평균 결정계수 0.95, 0.71로 분석되었으며, 이 모델을 이용하여 옥상온실의 에너지 부하를 동적으로 산정하기 위한 모델에 입력값으로 사용할 수 있을 것으로 판단된다.

설비공학 분야의 최근 연구 동향 : 2007년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2007)

  • 한화택;신동신;최창호;이대영;김서영;권용일
    • 설비공학논문집
    • /
    • 제20권12호
    • /
    • pp.844-861
    • /
    • 2008
  • The papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during the year of 2007 have been reviewed. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro nano fluid, micropump and fuel cell. Traditional CFD was still popular and widely used in research and development. Studies about fans and pumps were performed in the field of fluid machinery. Characteristics of flow and fin shape optimization are studied in the field of piping system. (2) The research works on heat transfer have been reviewed in the field of heat transfer characteristics, heat exchangers, and desiccant cooling systems. The research on heat transfer characteristics includes thermal transport in pulse tubes, high temperature superconductors, ground heat exchangers, fuel cell stacks and ice slurry systems. For the heat 'exchangers, the research on pin-tube heat exchanger, plate heat exchanger, condensers and gas coolers has been cordially implemented. The research works on heat transfer augmenting tubes have been also reported. For the desiccant cooling systems, the studies on the design and operating conditions for desiccant rotors as well as performance index are noticeable. (3) In the field of refrigeration, many papers were presented on the air conditioning system using CO2 as a refrigerant. The issues on the two-stage compression, the oil selection, and the appropriate oil charge were treated. The subjects of alternative refrigerants were also studied steadily. Hydrocarbons, DME and their mixtures were considered and various heat transfer correlations were proposed. (4) Research papers have been reviewed in the field of building facilities by grouping into the researches on heat and cold sources, air conditioning and air cleaning, ventilation and fire research including tunnel ventilation, flow control of piping system, and sound research with drain system. Main focuses have been addressed to the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies were mostly focused on analyzing the indoor environment in various spaces like cars, old tombs, machine rooms, and etc. in an architectural environmental field. Moreover, subjects of various fields such as the evaluation of noise, thermal environment, indoor air quality and development of energy analysis program were researched by various methods of survey, simulation, and field experiment.

마찰용접된 국산내열 강 (SUH3-SUS303 )의 시효열처리가 고온피로강도 및 파괴거동에 미치는 영향에 관한 연구 (The Effect of Aging Treatment on the High Temperature Fatigue Fracture Behavior of Friction Welded Domestic Heat Resisting Steels (SUH3-SUS 303))

  • 이규용;오세규
    • 수산해양기술연구
    • /
    • 제17권2호
    • /
    • pp.93-103
    • /
    • 1981
  • Si-Cr계 내열강 SUH3와 Cr-Ni계 stainless강 SUS 303 및 이들이 마찰용접재 SUH3-SUS303을 $1,060^{\circ}C$에서 용체화처리하고 다시 $700^{\circ}C$에서 10, 100시간 시효열처리한 각 시험편의 고온 피로강도에 대한 시효열처리의 효과를 알기 위하여 $700^{\circ}C$에서 고온 회전굽힘 피로시험을 하고 파약거동을 미시적으로 관찰하여 다음과 같은 결과를 얻었다. 1) SUH3재와 SUS303재의 최적마찰용접조건은 회전수 2420rpm, 마찰가압력 $8kg/mm^2$, 전 upset량 7mm(마찰가압시간 3sec, upset시간 2sec)이었다. 2) $700^{\circ}C$ 고온에서 장시간 이루어지는 고온피로시험에 있어, 용체화처리재의 S-N 곡선 경사부의 기울기가 가장 급하게 나타났다. 3) SUH3-SUS303 마찰용접재는 $1,060^{\circ}C$에서 1시간용체화 처리하고, $700^{\circ}C$에서 시효처리하는 경우 최적시효시간은 10시간이었다. 4) 10시간 시료재의 고온피로한도는 모재보다 SUH3은 75.4%, SUS303은 28.5% 높았으며, 용접재 SUH3-SUS303은 44.2% 정도 높았다. 100시간 시효재는 모재보다 SUH3은 64.91% SUS303은 30.4% 높았으며, SUH3-SUS303은 30.4% 높았으며, SUH3-SUS303은 36.6% 높았다. 5) 마찰용접재의 상온 및 고온의 피로파단은 모두 SUS303의 모재측에 발생하였으며, 용접면에서의 파단은 전혀 없었다. 6) SUS303재와 마찰용접재 SUH3-SUS303재의 크랙은 입내파양형이었으나 SUH3은 입계크랙의 전파로 파양한다.

  • PDF

선박 에너지 절감을 위한 기관실 팬 제어 시스템 구축 및 알고리즘에 관한 연구 (A Study on the Development of the Engine Room Fan Control System and ERFCS Algorithm for Ships Energy Saving)

  • 강영민;오진석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권6호
    • /
    • pp.642-648
    • /
    • 2015
  • 최근 선박에서 에너지 절감에 대한 많은 연구가 수행되고 있다. 그러한 연구의 일환으로 선박의 고정적인 부하를 제외한 변동 부하를 파악하고 제어함으로써 선박의 에너지를 절감할 수 있다. 기관실 팬 시스템은 대표적인 변동부하 중 하나이다. 기존 선박에서는 기관실 팬을 특별한 지침 없이 실 경험에 의해 정격운전으로 운용하고 있다. 이에 본 논문에서는 기관실 팬의 특성을 파악하고, 에너지 관리 시스템 중 하나로 ERFCS(Engine Room Fan Control System) 및 ERFCS 알고리즘을 제안하였다. ERFCS는 온도 및 압력에 따라 팬의 속도를 제어하며 부하 변화에 따라 팬의 운전 대수를 1대에서 4대 사이로 조절한다. 또한 기관실 팬의 최소 회전속도를 50%로 제한하여 낮은 RPM(Revolution Per Minute)에서 기계적 마찰, 발열 등의 이유로 팬이 손상을 입거나 낮은 압력으로 팬에 서징(surging) 현상이 발생하지 않도록 한다. 제안된 알고리즘과 ISO 8861을 바탕으로 LabVIEW를 사용한 팬 제어 시스템 시뮬레이션을 개발하였다. 결론적으로, 구현된 시뮬레이션을 통해 제안된 팬 제어 시스템이 기존 사용 방식에 비해 46.4%만의 동력만으로도 운전이 가능함을 확인하였다.

20년 이상 경과된 노후건축물의 단열재 성능평가에 관한 실험적 연구 (An Experimental Study on a Performance Evaluation of Internal Insulation of Buildings Over 20 Years Old)

  • 김현진;최세진
    • 한국건축시공학회지
    • /
    • 제19권6호
    • /
    • pp.539-547
    • /
    • 2019
  • 최근 국제사회는 지구온난화 방지를 위한 기후변화협약을 체결하고 건축물의 냉방 및 난방 에너지로 공급하는 화석연료 사용을 줄이고자 신축 또는 기존건물에 대한 녹색건축인증(G-SEED) 및 에너지효율등급, 건축물 에너지절약 설계기준 등을 일정조건 이상인 건축물에 의무적으로 적용하고 있다. 건물에 공급하는 에너지 공급을 줄이고 보온성을 향상시키는 건축자재로 단열재가 사용되고 있으며 신축건축물의 에너지절약 설계기준을 만족하는 건물외피 구성 재료 중 총 열 저항성의 90% 이상을 차지하고 있다. 그러나 기존건축물에 시공된 단열재의 경시변화에 대한 명확한 자료가 부족하여 건축물의 에너지성능 판단기준인 단위면적당 1차에너지 소요량 산정에 대한 의문점을 갖게 되었다, 이에 20년 이상 된 노후 건축물의 리모델링 현장에서 단열재(압출법,비드법)를 직접 채취하여 단열재성능을 비교·평가하였다. 실험결과, 압출법(XPS)은 생산초기 품질기준인 KS M 3808보다 열전도율은 48%, 압축강도는 36%가 저하되어 본래의 성능을 발휘하지 못함을 알 수 있었고, 비드법(EPS)의 경우 단열재 두께가 50mm인 경우 열전도율과 압축강도, 굴곡파괴하중 등이 생산초기 품질기준을 유지함을 알 수 있었다. 따라서 비드법의 경우 단열재 두께를 고려하여 현재의 단위면적당 1차 에너지소 요량을 기존대로 산정하고, 압출법의 경우는 단위면적당 1차 에너지소요량 산정시 보정계수를 적용해야 할 것으로 판단된다.

플라스틱온실 피복재의 관류열전달계수 변화 (Variation of the Overall Heat Transfer Coefficient of Plastic Greenhouse Covering Material)

  • 이현우;소레이멘디옵;김영식
    • 생물환경조절학회지
    • /
    • 제20권2호
    • /
    • pp.72-77
    • /
    • 2011
  • 본 연구는 국내 상업용 온실 피복재의 관류열전달계수를 산정히는데 필요한 기초자료를 제공하기 위하여 최근 국내에 많이 보급되어 사용되고 있는 플라스틱필름으로 피복된 온실에 대해 관류열량을 측정하고 관류열전달계수의 변화를 분석하였으며 그 결과를 요약하면 다음과 같다. 온실 내외부 온도차에 따른 관류열전달계수의 변화를 분석한 결과 피복의 층수에 따라 안정된 관류열전달계수를 나타내게 되는 온실 내외부 온도차의 값이 다르게 나타났기 때문에 온실 피복재에 대한 관류열전달계수를 결정할 때에는 피복층수별로 안정된 값을 나타내는 온실 내외부 온도차 범위에서의 관류열전달계수를 채택하여야할 것이다. 온도차이에 따른 관류열전달계수의 변화 경향은 기존의 연구결과와 잘 일치하였으나 안정된 값을 나타내는 온도차이의 구체적인 값은 다르게 나타났기 때문에 이에 대한 추가적인 연구가 필요할 것으로 판단된다. 풍속에 따른 관류열전달계수의 증가율은 연구자에 따라 많은 차이가 있음을 알 수 있었으며, 이중피복온실이나 커튼을 설치한 온실과 같이 보온성을 높인 온실은 일중피복온실에 비해 풍속에 따른 관류열 손실이 더 작다는 사실을 확인할 수 있었다. 관류열전달계수의 기존 연구결과들을 분석한 결과 연구자에 따라 값이 차이가 있었기 때문에 국내 온실의 정확한 난방부하량을 산정하는데 필요한 적절한 관류열전달계수를 제시하기 위해서는 우선 측정을 위한 표준화된 환경기준이 마련될 필요가 있으며, 또한 국내에서 실제로 사용되고 있는 주요 피복재별로 구체적인 관류열전달계수가 구해져야 할 것이다.