• 제목/요약/키워드: Heating cooling load

검색결과 384건 처리시간 0.024초

저속치환 공조시스템의 특성에 대한 연구 (On the Characteristics of the Low Velocity Displacement Air-Conditioning System)

  • 이계철;김동규;김경구;권영필
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.493-498
    • /
    • 2001
  • In the low velocity displacement air-conditioning system, the conditioned air is supplied from the diffuser placed on the wall near the floor and vented near the ceiling. This system has some advantages upon the traditional mixing system; the air quality near the people is improved by the displacing action of the system and the energy may be saved by neglecting the cooling or heating load for the upper space of the space above the people. This study is to examine the temperature and velocity distributions in the room and near the diffuser. It is found that the temperature is stratified uniformly all over the room space to show the displacing function of the system.

  • PDF

충격하중에 의한 용접구조물의 강도 증가에 관한 연구 (A Study on the strength improvement in weldment by the impact loading)

  • 양영수
    • 한국생산제조학회지
    • /
    • 제9권3호
    • /
    • pp.76-82
    • /
    • 2000
  • It is well known that during the oxygen cutting process residual thermal stresses are produced in weldment. The local non-uniform heating and subsequent cooling which takes place during any welding process causes complex thermal strains and stresses to finally lead to residual stresses exceed to the yield stress. High tensile stresses combined with applied structural load in the region near the welded joint can given rise to distortion brittle fracture change of the fatigue strength and stress corrosion cracking. The appropriate treatment of the welded component which reduces the peak of he welding residual stresses is believed to lower risk of the fracture during the service of the structure. In this study the impact loading in oxygen cutting frame was applied to reduce the residual stress. After applying the impact loading redistribution of resid-ual stress was measured by cutting method and the effect of fatigue was tested.

  • PDF

공동주택 발코니 창호의 차음성능 평가에 관한 실험적 연구 (An Experimental Study on Evaluation of the Sound Insulation for Balcony Window in Apartment Houses)

  • 김하근
    • 한국소음진동공학회논문집
    • /
    • 제14권11호
    • /
    • pp.1137-1146
    • /
    • 2004
  • In an apartment house In Korea, the balcony is one of the important spaces as a buffer zone for controlling the outdoor environments such as noise, heating & cooling load, humidity etc. Because most areas of building facade in apartment building occupy the area of balcony window the sound Insulation design of It Is very Important to provide the quiet indoor environment. The aim of this research is to evaluate the sound insulation of balcony windows in apartment building by new and revised Korean Industrial Standards. We measured and studied the sound insulations of 18 balcony windows by the type of measuring methods, noise sources, correction of reverberation time in balcony and so on. The results show that the single-number quantities for sound insulation of windows are ranged from 24 dB to 30 dB.

건물일체형 반투명 태양광발전모듈의 후면 유리 종류에 따른 온도 및 발전 특성 분석 (Analysis of Temperature and Generation Characteristics of Semi-transparent Module)

  • 박경은;강기환;김현일;유권종;김준태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1106-1107
    • /
    • 2008
  • Building Integrated PV(BIPV) is one of the best fascinating PV application technologies. To apply PV module in building, various factors should be reflected such as installation position, shading, temperature, and so on. Especially a temperature should be considered, for it affects both electrical efficiency of a PV module and heating/cooling load in a building. It reports the effect of thermal characteristics of the PV module on generation performance. The study was performed by monitoring the temperature and experiment. The results showed that 1 degree temperature rise reduced about 0.48% of output power.

  • PDF

Thermo-Diode식 태양열 이용 모듈(Smart Module)개발 (Development of Energy Efficient Smart Module with Variable Direction of Heat Flow, Heat Capacity and Surface Absorptivity)

  • 이경진;천원기
    • 태양에너지
    • /
    • 제18권3호
    • /
    • pp.119-128
    • /
    • 1998
  • 본 연구에서는 열흐름의 방향, 태양 복사열의 집열 그리고 축열부의 열용량 등이 조절 가능한 Thermo-Diode식 태양열 이용 모듈(Smart Module)의 개발하였으며, 이를 통하여 액체식 열다이오드에 대한 작동 메카니즘과 이를 적용한 태양열 이용 시스템의 효율적 작동과 그 가능성을 확인하였다. 기존의 태양열 시스템은 일조시간 동안만 시스템이 운용되는 반면 본 Smart Module은 낮뿐만 아니라 밤에도 단열 및 냉방부하 감소 효과를 거둘 수 있다.

  • PDF

The Indoor Environmental Quality Improving and Energy Saving Potential of Phase-Change Material Integrated Facades for High-Rise Office Buildings in Shanghai

  • Jin, Qian
    • 국제초고층학회논문집
    • /
    • 제6권2호
    • /
    • pp.197-205
    • /
    • 2017
  • The conflict between indoor environmental quality and energy consumption has become an unneglectable problem for highrise office buildings, where occupants' productivity is highly affected by their working environment. An effective Façade, therefore, should play the role of an active building skin by adapting to the ever-changing external environment and internal requirements. This paper explores the energy-saving and indoor environment-improving potential of a phase-change material (PCM) integrated Façade. Building performance simulations, combined with parametric study and sensitivity analysis, are adopted in this research. The result quantifies the potential of a PCM-integrated Façade with different configurations and PCM properties, taking as an example a south-oriented typical office room in Shanghai. It is found that a melting temperature of around $22^{\circ}C$ for the PCM layer is optimal. Compared to a conventional Façade, a PCM-integrated Façade effectively reduces total energy use, peak heating/cooling load, and operative temperature fluctuation during the periods of May-July and November-December.

차열도료 적용을 통한 국내 건축물의 에너지 성능 변화에 관한 연구 (A Study on the Change in Energy Performance of the Domestic Building by the Isolation-heat Paint)

  • 최두성;전흥찬;조균형
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.33-40
    • /
    • 2011
  • In this study, it is quantitatively analyzed for thermal Characteristics of isolation-heat paint which has been supplied to a domestic market through experiments and simulations. In the case of experiment using the container box, it shows 8% decrease on cooling energy consumption in a summer season, but shows increase on heating energy consumption. As a result, the analysis has found increase of energy consumption. As a result of holding simulations with meteorological data of domestic major cities, it shows an increase of energy consumption in domestic condition, and it is hard to expect an energy saving from the isolation-heat paint unless greater air-conditioning load.

Liquid Based Solar Thermal Storage를 위한 열교환성능(熱交換性能)에 관한 연구(硏究) (A Study on the Heat Exchange Performance for the Liquid Based Solar Thermal Storage)

  • 김병철;정현채
    • 태양에너지
    • /
    • 제5권2호
    • /
    • pp.35-45
    • /
    • 1985
  • A solar hot water storage tank was designed and constructed to examine the heat exchange performances on load side for the solar thermal storage in a single loop solar water heating system. In the tank helically coiled tube was immersed. The hot water was circulated from either top or bottom. The circulation flow rate was varied from 500 ml/min to 20,000 ml/min. The effect of flow rate was observed. The thermal performances according to the flow rate and flow direction were examined. The temperature distributions in the tank and inside of the tubes were plotted along the process of cooling.

  • PDF

공기 지중간 직접열교환시스템의 연중 열성능 해석 (Analysis on the thermal performances of air-earth direct heat exchanger in one year)

  • 김원갑;안정수;최영돈
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.517-526
    • /
    • 1997
  • This study is focused on the development and selection of the optimal cool tube system to maximize its thermal performance. Cool tube is devised to reduce the heating and cooling load of building by preheating or refreshing of intake air with buried pipes. Finite volume method is adopted to solve the conduction problem between the cool tube and earth. We examine the cool tube system for two operating periods, a short term(12 hours) and a long term(3 months). The results of short term operations reveal that condensation significantly influences and raises the exit air temperature. For long term operations, optimum conditions of cool tube system are obtained with variations of flow-rate, depth, length and diameter of cool tube.

  • PDF

현장타설 중단열 RC벽체의 구조적 성능 (Structural Performance for Sandwich Insulation of Reinforced-Concrete)

  • 박준호;유정호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.19-20
    • /
    • 2015
  • Building exterior wall's energy loss is very high rate comparing to all part of a buildings. And it account for upper 40% of cooling and heating load. So many studies conducted improving insulation performance of building's exterior, appeared about sandwich insulation wall which could be gaining merit of traditional insulation method those are exterior insulation and interior insulation. In this study, we inform structural performance of sandwich insulation wall for RC wall. For this, first, we define each wall's role and design sandwich insulation wall. At last, analyze structural performance of sandwich insulation wall. This study can contribute to apply it safely where side wall which toilet, stair area, etc.

  • PDF