• 제목/요약/키워드: Heating control

검색결과 1,589건 처리시간 0.037초

유도가열용 ZCS PWM SEPP 고주파 인버터 (Induction Heating ZCS PWM SEPP High Frequency Inverter)

  • 문상필;권순걸;이종걸;주석민;강신출
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.241-243
    • /
    • 2008
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Full)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

A Novel Auxiliary Edge-Resonant Snubber-Assisted Soft Switching PWM High Frequency Inverter with Series Capacitor Compensated Resonant Load for Consumer Induction Heating

  • Ahmed Nabil A.;Iwai Toshiaki;Omori Hideki;Lee Hyun-Woo;Nakaoka Mutsuo
    • Journal of Power Electronics
    • /
    • 제6권2호
    • /
    • pp.95-103
    • /
    • 2006
  • In this paper, a novel prototype of auxiliary switched capacitor assisted voltage source soft switching PWM Single-Ended Push Pull (SEPP) series capacitor compensated load resonant inverter with two auxiliary edge resonant lossless inductor snubbers is proposed and discussed for small scale consumer high-frequency induction heating (IH) appliances. The operation principle of this inverter is described by using switching mode equivalent circuits. The newly developed multi resonant high-frequency inverter using trench gate IGBTs can regulate its output AC power via constant frequency edge-resonant associated soft switching commutation by using an asymmetrical PWM control or duty cycle control scheme. The brand-new consumer IH products which use the newly proposed edge-resonant soft switching PWM-SEPP type series load resonant high-frequency inverters are evaluated using power regulation characteristics, actual efficiency vs. duty cycle and input power vs. actual efficiency characteristics. Their operating performance compared with some conventional soft switching high-frequency inverters for IH appliances is discussed on the basis of simulation and experimental results. The practical effectiveness of the newly proposed soft switching PWM SEPP series load resonant inverter is verified from an application point of view as being suitable for consumer high-frequency IH appliances.

Steady-State Analysis of ZVS and NON-ZVS Full-Bridge Inverters with Asymmetrical Control for Induction Heating Applications

  • Yachiangkam, Samart;Sangswang, Anawach;Naetiladdanon, Sumate;Koompai, Chayant;Chudjuarjeen, Saichol
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.544-554
    • /
    • 2015
  • This paper presents a steady-state operation analysis of full-bridge series-resonant inverters focusing on the distorted load current due to low-quality-factor resonant circuits in induction heating and other applications. The regions of operation based on the zero-voltage switching (ZVS) and non-zero-voltage switching (NON-ZVS) operations of the asymmetrical voltage-cancellation control technique are identified. The effects of a distorted load current under a wide range of output powers are also analyzed for achieving a precise ZVS operating region. An experimental study is performed with a 1kW prototype. Simulation and experimental studies have confirmed the validity of the proposed method. An efficiency comparison between the variable frequency method and the conventional fixed-frequency method is provided.

고온가스 및 액체 바이패스 적용 용량가변 히트펌프의 성능특성에 관한 실험적 연구 (An Experimental Study on the Performance Characteristics of Hot-gas and Liquid Bypass Heat Pump Systems for Capacity Modulation)

  • 안재환;주영주;윤원재;강훈;김용찬
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.137-142
    • /
    • 2013
  • A small air-conditioner or chiller for a constant temperature bath normally uses a constant speed compressor. The constant speed compressor is relatively inexpensive, but it uses on/off control for capacity modulation. The on/off control has several disadvantages, specifically energy loss and large temperature fluctuation. Continuous operation with a bypass system can be an alternative to on/off control, for capacity modulation. In this study, a heat pump system having a hot-gas bypass and a liquid bypass was adopted. The performance of the bypass-type heat pump was measured, by varying the bypass valve opening. The differences of the COP between the hot-gas bypass and the liquid bypass, in the cooling and heating operations, were within 2% and 1%, respectively. The liquid bypass showed a wider range of capacity control in the cooling operation but the hot-gas bypass showed a wider range of capacity control in the heating operation.

A Current-Fed Parallel Resonant Push-Pull Inverter with a New Cascaded Coil Flux Control for Induction Heating Applications

  • Namadmalan, Alireza;Moghani, Javad Shokrollahi;Milimonfare, Jafar
    • Journal of Power Electronics
    • /
    • 제11권5호
    • /
    • pp.632-638
    • /
    • 2011
  • This paper presents a cascaded coil flux control based on a Current Source Parallel Resonant Push-Pull Inverter (CSPRPI) for Induction Heating (IH) applications. The most important problems associated with current source parallel resonant inverters are start-up problems and the variable response of IH systems under load variations. This paper proposes a simple cascaded control method to increase an IH system's robustness to load variations. The proposed IH has been analyzed in both the steady state and the transient state. Based on this method, the resonant frequency is tracked using Phase Locked Loop (PLL) circuits using a Multiplier Phase Detector (MPD) to achieve ZVS under the transient condition. A laboratory prototype was built with an operating frequency of 57-59 kHz and a rated power of 300 W. Simulation and experimental results verify the validity of the proposed power control method and the PLL dynamics.

알루미늄 용해로의 열량변동대응 공연비제어기술 (Air-Fuel ratio Control Technology Corresponding to High Heating Value Variation for Aluminum Melting Furnace)

  • 이중성;유현석;한정옥
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2015년도 제51회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.131-134
    • /
    • 2015
  • 국내 천연가스 열량제도를 현행 표준 열량제 $10,400kcal/Nm^3(43.54MJ/Nm^3)$에서 중간 조정기간을 두고 2012.07.01부터는 최저 $10,100kcal/Nm^3(42.28MJ/Nm^3)$을 유지하고 2015년 이후 $9,800(41.1MJ/Nm^3){\sim}10,600kcal/Nm^3(44.4MJ/Nm^3)$ 열량범위제도로 변경 추진되고 있다. 산업현장에서 열량변동을 측정하여 공연비 제어기술을 개발하고자 60ton Al 용해로에 열량대응기술 개발을 위한 내용으로 열량측정시스템설치 및 열량 값과 연계하여 공연비 제어기술개발연구 내용으로 결과는 다음과 같다. 단순히 표준열량으로 에 맞춰 프로그램된 제어로직에 열량변동에서 검출된 신호를 이용하여 연료보정 값을 추가한 로직을 재구성할 필요가 있다. 이 혀장의 경우는 용탕의 온도가 목표온도 근처까지 올리기가 어려워진 상황으로 주로 공급열량 저열량화에 따른 과잉공기영향으로 온도상승이 어려워 보이며 적절한 공연비로 최적화 되면 이러한 문제가 개선되리라 생각된다.

  • PDF

Improved Modification of the Closed-Loop-Controlled AC-AC Resonant Converter for Induction Heating

  • Dhandapani, Kirubakaran;Sathi, Rama Reddy
    • ETRI Journal
    • /
    • 제31권3호
    • /
    • pp.298-303
    • /
    • 2009
  • A single-switch parallel resonant converter for induction heating is implemented. The circuit consists of an input LC-filter, a bridge rectifier, and a controlled power switch. The switch operates in soft commutation mode and serves as a high frequency generator. The output power is controlled via the switching frequency. A steady state analysis of the converter operation is presented. A closed-loop circuit model is also presented, and the experimental results are compared with the simulation results.

  • PDF

Development of Heat Pump System for the Greenhouse Heating

  • Song, Hyun-Kap;Ryou, Young-Sun;Park, Jong-Kil
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.1101-1116
    • /
    • 1996
  • It is desirable to use the renewable energy for the greenhouse heating in winter season, it makes possible not only to save fossil fuel and conserve green farm environment but also to promote the quality of agricultural products and reduce the agricultural production cost. In this study the heat pump system was developed to use the natural energy as thermal energy resource for the thermal environment control of the greenhouse.

  • PDF

인덕션 조리기기의 인버터 출력 최적제어 (Optimal Inverter Power Control for Induction Heating Appliance)

  • 이세민;박정욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.166-167
    • /
    • 2007
  • 본 논문은 고주파 IH(Induction Heating) 조리기기의 전원으로 사용되는 인버터를 PI 제어기를 사용하여 듀티비를 가변시켜 출력을 최적 제어하는 회로를 제시하였다. 분석에 사용된 기본 인버터 회로는 Single-Ended Push-Pull (SEPP) 영전류 스위칭 공진인버터이며 실제 IH 조리기기의 동작을 구현하기 위해 입력단의 전원으로 220V 60Hz 정현파와 브리지 정류기, 평활 콘덴서를 사용하였다. 회로의 해석과 시뮬레이션을 위해 범용 시뮬레이션 툴인 Pspice를 이용하여 분석하였다. 향후, 제안된 제어방법은 유사한 IH 기기, DC-DC 컨버터, 인덕션 모터등의 시스템에 활용되리라 기대된다.

  • PDF