• Title/Summary/Keyword: Heating Pressure

Search Result 918, Processing Time 0.027 seconds

Large Area Bernal Stacked Bilayer Graphene Grown by Multi Heating Zone Low Pressure Chemical Vapor Deposition

  • Han, Jaehyun;Yeo, Jong-Souk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.239.2-239.2
    • /
    • 2015
  • Graphene is a most interesting material due to its unique and outstanding properties. However, semi-metallic properties of graphene along with zero bandgap energy structure limit further application to optoelectronic devices. Recently, many researchers have shown that band gap can be induced in the Bernal stacked bilayer graphene. Several methods have been used for the controlled growth of the Bernal staked bilayer graphene, but it is still challenging to control the growth process. In this paper, we synthesize the large area Bernal stacked bilayer graphene using multi heating zone low pressure chemical vapor deposition (LPCVD). The synthesized bilayer graphenes are characterized by Raman spectroscopy, optical microscope (OM), scanning electron microscopy (SEM). High resolution transmission electron microscopy (HRTEM) is used for the observation of atomic resolution image of the graphene layers.

  • PDF

Development of Y Strainer Type Automatic Flow Rate Regulating Valve (Y 스트레이너형 자동 정유량 조절 밸브의 개발)

  • Yoon, Joon-Yong;Kwon, Woo-Chul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.1 s.40
    • /
    • pp.49-55
    • /
    • 2007
  • An 'Y' strainer type automatic flow rate regulating valve, which functions are to remove impurities from hot water inside the pipe and to maintain a constant flow rate regardless of variations of the differential pressure between valve inlet and outlet at the same time, is developed for distributing hot water equally to several pipes with district heating or central heating system. Numerical analysis of the three dimensional turbulent flow field in a valve shape is carried out to confirm the flow field whether the designed regulator shape is acceptable or not. The final developed valve improves installation time and cost and maintenance ability comparing with set-up 'Y' strainer and regulator separately. Tolerance for the nominal flow rate is also satisfied within ${\pm}5%$.

Effect of Excess Air and Superficial Air Velocity on Operation Characteristics in a Fluidized Bed Coal Combustor (공탑속도 및 과잉공기비에 따른 석탄유동층연소로의 조업특성)

  • 장현태;차왕석;태범석
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.84-92
    • /
    • 1999
  • The effects of air velocity and excess air on combustion characteristics were studied in a fluidized bed combustor. The domestic low-grade anthracite coal with heating value of 2010 kcal/kg and the imported bituminous coal from Australia with heating value of 6520 kcal/kg were used as coal samples. The combustion characteristics of mixed fuels in a fluidized bed combustor could be interpreted by pressure fluctuation properties, ash distribution and gas emission. The properties of the pressure fluctuations, such as the standard deviation, cross-correlation function, dominant frequency and the power spectral density function, were obtained from the statistical analysis. From this study, the combustion region increased with increasing air velocity but decreased with excess air due to combustion characteristics of anthracite and bituminous coal.

  • PDF

A Study on Characteristics of Emulsified Fuel (유화연료의 특성에 관한 연구)

  • Jung, J.S.;Kim, J.J.;Lee, K.B.
    • 한국연소학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.105-110
    • /
    • 1999
  • The elementary experiment was performed to develop the emulsified fuel production system using pressure injection nozzle in this study. The stabilities and characteristics of emulsified fuel which is produced through direct spray of water via pressure injection nozzle into oil are examined. To understand performance of emulsion production, stabilities of emulsified fuel which is made by adding water to the mixed fuel of Bunker-C and 10 $^{\sim}$ 50 vol% of heating oil were investigated. According to volume ratios of surfactant in heating oil the stability and SMDs were measured

  • PDF

Eating Qualities of Frozen Cooked Rice on the Thawing Condition (해동조건에 따른 냉동밥의 밥맛 비교)

  • 오명숙
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.2
    • /
    • pp.147-157
    • /
    • 1997
  • It attempted to determine the effect of various thawing methods, such as pressure cooking, conventional cooking, microwave heating and thawing at room temperature, on the quality of frozen cooked rice using Nongan variety of rice. These effects were analysed at three different periods-after 10 days, 30 days and 90 days. It conducted a physico-chemical analysis(moisture content, dehydration rates, color value and texture) and sensory evaluation o the frozen-thawed cooked rice. The study showed that there were no significant differences on the frozen-thawed cooked rice. The study showed that there were no significant differences on the quality characteristics of frozen-thawed cooked rice during the storage of 90 days. However, the thawing method of pressure cooking caused high moisture content and decrease in hardness on the cooked rice, the desirability for the rice didn't diminish compared with the cooked rice just after cooking. the quality characteristics of the cooked rice after frozen-thawing by conventional cooking and microwave heating were similar with that of the cooked rice just after cooking. thawing at room temperature caused a significant decrease in quality characteristics.

  • PDF

A Study on Performance Characteristics of Heat Exchanger for Heat Pump with R410A Refrigerant (R410A 냉매를 사용한 열펌프용 열교환기의 형상에 따른 성능특성 연구)

  • 정규하;박윤철;오상경
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.340-348
    • /
    • 2004
  • The air and refrigerant side heat transfer performances are key parameters to improve heat transfer efficiency of the heat exchanger including the fan performance. Design of the fins, treatment of the tube inside, tube diameter and tube array effect heat transfer performance of the heat exchanger. The heat exchanger is used as a condenser at cooling mode and used as an evaporator at heating mode in the heat pump system. The heat pump system uses R410A as the refrigerant. The heat exchangers are consisted with 7 mm diameter tubes with slit-type fins. The study was conducted with variation of arrangement of the refrigerant path and air flow rate and refrigerant pressure drop and heat transfer rate were measured with a code tester. The capacity of the 3 path heat exchanger is more efficient than 2 or 4 path heat exchangers in heating or cooling modes.

Crystallinity and Mechanical Properties of Glass Fiber Reinforced Thermoplastic Composites by Rapid Press Consolidation Technique (Consolidation 방법에 의해 제작된 유리섬유강화 복합재료의 결정성과 기계적성질에 관한 연구)

  • Shin, Ick-Jae;Kim, Dong-Young;Lee, Dong-Joo
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.91-96
    • /
    • 2000
  • Glass fiber reinforced thermoplastic composites were manufactured by Rapid Press Consolidation Technique(RPCT) as functions of temperature, pressure and time in pre-heating, consolidation and solidification sections during the manufacturing processing. It was found that the material property is greatly affected by pre-heating temperature under vacuum, mold temperature and molding pressure. Among them, the temperature In the mold was the most critical factor in determining the mechanical properties and the molded conditions of specimen. The crystallinity of PET matrix was also investigated by differential scanning calorimetry(DSC) measurements for various processing conditions. The level of crystallinity($X_c$) depended strongly on the mold temperature, cooling rate and the type of composite. The difference in $X_c$ is believed to be one of important factors in characterizing the mechanical properties.

  • PDF

A Study on Fatigue Characteristics of Dissimilar Spring Steel(SUP9A)-SM25C by Friction Welding (스프링강(SUP9A)-SM25C의 이종재 마찰용접 피로특성에 관한 연구)

  • 정석주;이기중
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.3
    • /
    • pp.19-25
    • /
    • 2001
  • The friction-welding SM25C is a substitute for the suing steel that is utilized in the machinery, airplane, and automobile, ok. This substitution would provide reduction of material and weight of welding parts. From the result we found that the strength of the friction welded joint was 529-617MPa and the toughness 1.2 times higher than that of the base metal. The optimal condition of friction welding was found as follows : n=2000rpm, $P_1$=68㎫, $P_2$=137MPa, $t_2$=2sec, $t_1$=2-4sec, Considering the strength, the hardness, and the reduction of area in the friction welding, the fiction welding using SUP9A and SM25C was found to cause no problem in on-the-job application.

  • PDF

Design and Manufacture of Direct Solar Hot Water Heating System Using Pressure Relief Tube and Expandable Header (감압 튜브 및 팽창헤더를 이용한 직접식 태양열 온수기의 설계 및 제작에 관한 연구)

  • Chun, Won-Gee;Kim, Hyung-Taek
    • Solar Energy
    • /
    • v.20 no.3
    • /
    • pp.51-60
    • /
    • 2000
  • This paper deals with the design, construction and operation of a direct solar hot water heating system developed to harness the solar energy more effectively. The system introduced here uses a unique network of riser tubes and header pipes apart from the existing concept to exploit the physical properties of water which expands when it freezes. It also employs a special pressure relief mechanism for the header to prevent its breakage due to freezing. A number of tests are made to assure its functional reliability during frigid weather conditions and its superior performance over indirect systems.

  • PDF

Performance Characteristics of R134a Supercritical Heat Pump (R134a 냉매용 초임계 히트펌프의 성능 특성)

  • Choi, In-Soo
    • Journal of Power System Engineering
    • /
    • v.18 no.4
    • /
    • pp.60-65
    • /
    • 2014
  • In this paper, cycle performance analysis for heating capacity, compression work and COP of R134a supercritical heat pump is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include superheating degree, pressure and outlet temperature of gas cooler, compressor efficiency and evaporating temperature in the R134a supercritical heat pump system. The main results were summarized as follows : Superheating degree, pressure and outlet temperature of gas cooler, compressor efficiency and evaporating temperature of R134a heat pump system have an effect on the heating capacity, compression work and COP of this system. With a thorough grasp of these effect, it is necessary to design the supercritical heat pump using R134a. The prediction for COP of R134a supercritical heat pump have been proposed through multiple regression analysis.